• Title/Summary/Keyword: Protein-A gold

검색결과 142건 처리시간 0.026초

Detection of Escherichia coli O157:H7 Using Immunosensor Based on Surface Plasmon Resonance

  • Oh, Byung-Keun;Kim, Young-Kee;Bae, Young-Min;Lee, Won-Hong;Choi, Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제12권5호
    • /
    • pp.780-786
    • /
    • 2002
  • An immunosensor based on surface plasmon resonance (SPR) with a self-assembled protein G layer was developed for the detection of Escherichia coli O157:H7. A self-assembled protein C layer on a gold (Au) surface was fabricated by adsorbing the mixture of 11-mercaptoundecanoic acid (MUA) and hexanethiol at various molar ratios and by activating chemical binding between free amine (-$NH_2$) of protein G and 11-(MUA) using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDAC) in series. The formation of a self-assembled protein G layer on an Au substrate and the binding of the antibody and antigen in series were confirmed by SPR spectroscopy. The surface morphology analyses of the self-assembled protein G layer on the Au substrate, monoclonal antibody (Mab) against E. coli O157:H7 which was immobilized on protein G, and bound E. coli O157:H7 extracts on Immobilized Mab against E. coii O157:H7 were performed by atomic force microscopy (AFM). The detection limit of the SPR-based immunosensor for E. coli O157:H7 was found to be about $10^4$ cells/ml.

Double-Enhancement Strategy: A Practical Approach to a Femto-Molar Level Detection of Prostate Specific $Antigen-{\alpha}_1-Antichymotrypsin$ (PSA/ACT Complex) for SPR Immunosensing

  • Cao, Cuong;Sim, Sang-Jun
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권6호
    • /
    • pp.1031-1035
    • /
    • 2007
  • Prostate specific $antigen-{\alpha}_1-antichymotrypsin$ was detected by a double-enhancement strategy involving the exploitation of both colloidal gold nanoparticles (AuNPs) and precipitation of an insoluble product formed by HRP-biocatalyzed oxidation. The AuNPs were synthesized and conjugated with horse-radish peroxidase-PSA polyclonal antibody by physisorption. Using the protein-colloid for SPR-based detection of the PSPJACT complex showed their enhancement as being consistent with other previous studies with regard to AuNPs enhancement, while the enzyme precipitation using DAB substrate was applied for the first time and greatly amplified the signal. The limit of detection was found at as low as 0.027 ng/ml of the PSA/ACT complex (or 300 fM), which is much higher than that of previous reports. This study indicates another way to enhance SPR measurement, and it is generally applicable to other SPR-based immunoassays.

QCM Study of β-Casein Adsorption on the Hydrophobic Surface: Effect of Ionic Strength and Cations

  • Lee, Myung-Hee;Park, Su-Kyung;Chung, Chin-Kap;Kim, Hack-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권7호
    • /
    • pp.1031-1035
    • /
    • 2004
  • The adsorption kinetics of ${\beta}$-casein on a hydrophobic surface has been studied by means of the quartz crystal microbalance (QCM). The self assembled monolayer of 1-octadecanethiol on a gold coated quartz crystal was used as a hydrophobic surface for adsorption. The adsorption kinetics was monitored in different solution conditions. Formation of monolayer is observed in most cases. At high concentration of protein, micelle formation which is interrupted by high ionic strength of solution is observed. Casein binding cations such as $Ca^{2+},\;Ba^{2+}\;and\;Al^{3+}$ increase the hydrophobicity of the protein and the multiple layer adsorption occurs. The strong and weak points of the QCM method in the study of protein adsorption are discussed.

Development of piezoelectric immunosensor for the rapid detection of marine derived pathogenic bacteria, Vibrio vulnificus

  • Hong, Suhee;Jeong, Hyun-Do
    • 한국어병학회지
    • /
    • 제27권2호
    • /
    • pp.99-105
    • /
    • 2014
  • Biosensors consist of biochemical recognition agents like antibodies immobilized on the surfaces of transducers that change the recognition into a measurable electronic signal. Here we report a piezoelectric immunosensor made to detect Vibrio vulnificus. A 9MHz AT-cut piezoelectric wafer attached with two gold electrodes of 5mm diameter was used as the transducer of the QCM biosensor with a reproducibility of ${\pm}0.1Hz$ in frequency response. We have tried different approaches to immobilize antibody on the sensor chip. Concerning the orientation of antibody for the best antigen binding capacity, the antibody was immobilized by specific binding to protein G or by cross-linking through hydrazine. In addition, protein G was cross-linked on glutaraldehyde activated immine layer (PEI) or EDC/NHS activated sulfide monolayer (MPA). PEI was found to be more effective to immobilize protein G following glutaraldehyde activation than MPA. However, hydrazine chip showed a better capability to immobilize more IgG than protein G chip and a higher sensitivity. The sensor system was able to detect V. vulnificus in dose dependent manner and was able to detect bacterial cells within 5 minutes by monitoring frequency shifts in real time. The detection limit can be improved by preincubation to enrich the bacterial cell number.

수정진동자를 이용한 Au 표면에서 avidin-biotin 결합 리포좀 막의 구조 분석

  • 박종원;한성웅;권정훈;박진영;조홍식;이행자;장상목
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.546-549
    • /
    • 2000
  • Avidin-biotin의 강한 결합력을 이용하여 금속 표면 위에 리포좀과 같은 유기 분자막의 다층 형성 과정을 QCA의 공진주파수와 공진저항의 변화를 측정하므로서 실시간 모니터링의 가능성을 검토하고, 유기 분자막이 금속 표면 위에 적층 됨에 따라 형성되는 적층 막에 대한 정보를 수집함으로서 바이오센서 시스템으로 QCA를 적용 가능함의 기초 데이터를 제공하고자 한다.

  • PDF

Surface Plasmon Resonance Immunosensor for Detection of Legionella pneumophila

  • Oh, Byung-Keun;Lee, Woochang;Bae, Young-Min;Lee, Won-Hong;Park, Jeong-Woo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제8권2호
    • /
    • pp.112-116
    • /
    • 2003
  • An immunosensor based on surface plasmon resonance (SPR) onto a protein G layer by Self-assembly technique was developed for detection of Legionella pneumophila. The protein G layer by self-assembly technique was fabricated on a gold (Au) surface by adsorbing the 11-mercaptoundecanoic acid (MUA) and an activation process for the chemical binding of the free amino (-NH$_2$) of protein G and 11-(MUA) using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDAC) in series. The formation of the protein G layer by self-assembly technique on the Au Substrate and the binding of the antibody and antigen in series were confirmed by SPR spectroscopy. The Surface topographies of the fabricated thin films on an Au substrate were also analyzed by using an atomic force microscope (AFM). Consequently, an immunosensor for the detection of L. pneumophila using SPR was developed with a detection limit of up to 10$^2$CFU per mL.

Extended Gate를 이용한 MOSFET형 단백질 센서 제작 및 특성 (Fabrication and chracteristics of MOSFET type protein sensor using extended gate)

  • 이상권;손영수;최시영
    • 센서학회지
    • /
    • 제16권2호
    • /
    • pp.104-109
    • /
    • 2007
  • In this paper, we have fabricated on extended-gate field effect transistor (EGFET)-type protein sensor for the application to a CRP detection. We used the self-assembled monolayer (SAM) to adhere or entrap biomolecules, namely CRP antibodies. The experimental result shows that the proposed SAM is well immobilized on the gold gate surface. So the drain current was varied by antigen-antibody interactions on the gate surface because of the CRP charge. Experimental results related to the formation of SAM, antibody, antigen were obtained by measuring the electrical characteristics of the EGFET device.

Expression of Polyhistidine-Containing Fusion Human HepG2 Type Glucose Transport Protein in Spodoptera Cells and Its Purification Using a Metal Affinity Chromatography

  • 이종기
    • 대한의생명과학회지
    • /
    • 제16권3호
    • /
    • pp.201-206
    • /
    • 2010
  • In order to develop procedures for the rapid isolation of recombinant sugar transporter in functional form from away from the endogenous insect cell transporter, gene fusion techniques were exploited. Briefly, BamH1-digested human HepG2 type glucose transport protein cDNA was first cloned into a transfer vector pBlueBacHis, containing a tract of six histidine residues. Recombinant baculoviruses including the human cDNA were then generated by allelic exchange following transfection of insect cells with wild-type BaculoGold virus DNA and the recombinant transfer vector. Plaque assay was then performed to obtain and purify recombinant viruses expressing the human transport protein. All the cell samples that had been infected with viruses from the several blue plaques exhibited a positive reaction in the immnuassay, demonstrating expression of the glucose transport protein. In contrast, no color development in the immunoassay was observed for cells infected with the wild-type virus or no virus. Immunoblot analysis showed that a major immunoreactive band of apparent Mr 43,000~44,000 was evident in the lysate from cells infected with the recombinant baculovirus. Following expression of the recombinant fusion protein with the metal-binding domain and enterokinase cleavage site, the fusion protein was recovered by competition with imidizole using immobilized metal charged resin. The leader peptide was then removed from the fusion protein by cleavage with porcine enterokinase. Final separation of the recombinant protein of the interest was achieved by passage over $Ni^{2+}$-charged resin under binding conditions. The expressed transport protein bound cytochalasin B and demonstrated a functional similarity to its human counterpart.

Antibody Layer Fabrication for Protein Chip to Detect E. coli O157:H7, Using Microcontact Printing Technique

  • KIM HUN-SOO;BAE YOUNG-MIN;KIM YOUNG-KEE;OH BYUNG-KEUN;CHOI JEONG-WOO
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권1호
    • /
    • pp.141-144
    • /
    • 2006
  • An antibody layer was fabricated to detect Escherichia coli O157:H7. The micropattern of 16-mercaptohexadecanoic acid (16-MHDA) as alkylthiolate was formed on the gold surface by using the PDMS stamp with microcontact printing $({\mu}CP)$ techniques. In order to form antibody patterns on the template, protein G was chemically bound to the 16-MHDA patterns, and antibody was adsorbed on a self-assembled protein G layer. The formation of the 16-MHDA micropattern, self-assembled protein G layer and antibody pattern on Au substrate was confirmed by surface plasmon resonance (SPR) spectroscopy. Finally, the micropatterning method was applied to fabricate the antibody probe for detection of E. coli O157:H7, and monitoring of antigen by using this probe was successfully achieved.

연 X-선 현미경을 이용한 금 나노입자 세포영상 (Cellular Imaging of Gold Nanoparticles Using a Compact Soft X-Ray Microscope)

  • 권영만;김한경;김경우;김선희;윤홍화;천권수;강성훈;박성훈;정선관;윤권하
    • Applied Microscopy
    • /
    • 제38권3호
    • /
    • pp.235-243
    • /
    • 2008
  • 연 x-선 현미경은 '물의 창' 영역 ($2.3{\sim}4.4nm$)의 파장을 이용하여, 수십 nm의 분해능으로 세포를 파괴하지 않고 살아있는 상태에서 세포의 내부구조를 관찰할 수 있어 가시광선현미경과 전자현미경을 단점을 보완하는 특징을 갖는 세포 생물학 연구에 적합한 현미경이다. 그러나 기존 연 x-선 현미경은 광원으로 방사선 가속기를 이용하기 때문에 사용이 제한적이었다. 이에, 본 연구에서는 2.88nm의 연 x-선을 광원으로 사용하는 소형 연 x-선 현미경을 이용하여, 내포작용에 의해 금 나노입자를 포획한 HT1080과 MDA-MB 231 세포의 영상을 약 60nm 분해능으로 획득하였다. 금 나노입자의 세포에 대한 독성을 제거하기 위하여 폴리에틸렌 글리콜을 캡핑하였고, 2.88nm 파장의 연 x-선에 대하여 충분한 조영효과로 인하여 세포영상에서 뚜렷한 대조도를 나타내었다. 내포작용에 의해 액포에 포함되어 있는 다양한 크기의 금 나노입자 군집을 확인하였으며, 세포내부의 액포의 분포상태도 관찰할 수 있었다. 따라서 고분해능을 가진 소형 연 x-선 현미경을 이용하여 금 나노입자를 세포내의 미세기관이나 특정 단백질에 표지하면 연 x-선에 대한 조영효과의 증가에 의하여 더욱 유용한 정보를 획득할 수 있을 것으로 생각한다.