The analysis of arc dispersion and contacts characteristics according to switching of RCD for low voltage (저압용 누전차단기의 스위칭에 따른 아크 비산 및 접점의 특성분석)

  • Kim, Dong-Woo;Kim, Hyang-Kon;Gil, Hyung-Jun;Han, Woon-Ki;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.69-73
    • /
    • 2005
  • The arc dispersion and contacts characteristics were analyzed according to switching off Residual Current Protective Device(RCD) switch. Arc dispersion process was taken by high speed imaging system at a rate of 10,000 frames per second. When RCD was switched from on to off, art was observed and it took about 2.3[ms] from the generation of arc to the extinction of arc. When RCD was switched from off to on, arc was not observed. We repeated switching on and off 1000, 3000 and 6000 times. After repetition, the surface characteristics of contacts were taken by stereo microscope and Scanning Electron Microscope(SEM). From the scattering patterns analysis of arc and the analysis of deteriorated contacts, it could be applicable to the research of electric fire and arc suppression.

  • PDF

A Study on the Shock Absorption Performance of the Safety Helmet using Coefficient of Restitution (반발계수를 이용한 안전모의 충격 흡수 성능에 관한 연구)

  • Shin, Woon-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.30-34
    • /
    • 2012
  • A safety helmet is a personal protective equipment to protect the head from falling and flying objects. A safety helmet has the maximum delivered impact force as shock absorption performance, the lower delivered impact force the better performance, which was not a controlled variety during manufacturing safety helmet. Accordingly there were some difficulties in establishing the standard for improved performance as there was not a clear controllable impact force for improved performance. In this study the shock absorption performance was intended to be found as coefficient of restitution related to impulse. As a research method, a coefficient of restitution during the absorption of shock was calculated using the impulse transferred to pharynx utilizing the safety helmet shock absorption performance testing device based on the theory of momentum and impulse. The estimated impulsive force curve was derived assuming that shock was not absorbed using the measured data. The sample was selected as tested goods of ABS material for safety certification available mainly in the market. As a result of study, the maximum delivered impact force of safety helmet made by a domestic safety certified a company was 735 N, and its coefficient of restitution proved to be 0.64. The smaller coefficient of restitution is, the lower maximum delivered impact force and the higher shock absorption performance. The coefficient of restitution can be used as a performance index of safety helmet.

A Study on the Life Time of RCD in Coastal Area (해안지역에서의 저압용 누전차단기 교체주기 연구)

  • Kim, Chong-Min;Choi, Myeong-Il;Shong, Kil-Mok;Seo, Jung-Youl;Shin, Jin-Yong;Kim, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.85-92
    • /
    • 2011
  • The role of RCDs(Residual Current Protective Device) that are installed before the load is very important for preventing electric shock and electrical fire. However, although fault rate of RCD is increasing due to deterioration and long period usage, the RCD is permanently used without a checking of performance evaluation and it causes the electrical accident. In this paper, the amount of airborne chloride is researched in domestic costal area and the accelerated life test is conducted using a salt water spray tester in order to decide the life time of RCD. Aa a result of an accelerated life test, the MTTF(Mean Time To Failure) of RCD is 110.81 hours and B10 life time of RCD is 45.81 hours for the all samples. when an accelerated life test result is applied to within 2 km costal area, the life time of RCD is predicted about 5 years.

Measurement of Secondary Electron Emission Coefficient on Deposition Time of the Silicon Thin Films (실리콘박막의 증착시간에 따른 감마계수 측정법 개발)

  • Lee, Jung-Hui;Choi, Byoung-Jung;Yang, Sung-Chae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.330-331
    • /
    • 2006
  • Recently, plasma display panels (PDPs) are highlighted for the flat type display device. Therefore, much attention has been paid to secondary electron emission coefficient of the electrode protective material of PDPs. As PDPs is developing, the concern about secondary electron emission coefficient ($\gamma$) which is related with PDPs electrode protection material is increasing continually. So the concern about the way to how to measure secondary electron emission coefficient is on the rise. At present, the way to how to measure secondary electron emission coefficient is developed by some research groups, which is giving some research part's advance help. In this research, we have studied how to measure secondary electron emission coefficient which is related with various thin films more conveniently than previous measurement method. We studied the method of measurement of secondary electron emission coefficient (${\gamma}$) of amorphous silicon films by using Paschen's curve.

  • PDF

Analysis on Metal Contact Resistance and Grain Boundary Barrier Height of Ceramic PTC Thermistor (Ceramic PTC thermistor의 금속접촉저항과 입계전위장벽)

  • Jeon, Yong-Woo;Lim, Byung-Jae;Hong, Sang-Jin;Soh, Dea-Wha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.235-236
    • /
    • 2006
  • The contact resistance and grain boundary potential barrier of ceramic $BaTiO_3$ PTCR were investigated. The electroless plated Ni, evaporated Al, and Ag paste were chosen as electrode materials of PTCR device for comparison analysis before and after heat treatment. The contact resistance of electrode were measured by electrometer (dc), digital multimeter (dc), and LCR meter (ac). In the case of Al electroded samples, the heat treatment and protective oxide layer had high resistance and effect on the stability of PTCR effect against contact resistance degradation, but the Ag-paste had comparably high contact resistance before heat treatment and decreased after heat treatment with safe. On the other hand, the samples with electroless plated Ni electrode had good properties of contact resistance against aging.

  • PDF

LASER WELDING APPLICATION IN CAR BODY MANUFACTURING

  • Shin, Hyun-Oh;Chang, In-Sung;Jung, Chang-Ho
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.181-186
    • /
    • 2002
  • Laser welding application for car body manufacturing has many advantages in the stiffness and the lightness of vehicle, the productivity of assembly line, and the degree of freedom in design. This presentation will express the innovation of car body manufacturing including parameter optimization, process modeling, and system integration. In this application the investment for systems was cut down dramatically by real time switching over the laser path between two welding stations. Points of technical discussion are as follows: optimization of parameters such as laser power, robot speed and trajectory, compact and useful design of jig & fixture to assure welding quality for 3 sheet-layer zinc-coated steel, system integration between 4kW Nd:YAG laser device and the other systems, on-line real time welding quality monitoring system, perfect safety standards for high power laser, minimization of consumption costs such as arc lamp, protective glass for optic, etc. Laser welding has found a place on Hyundai's production plant in conjunction with the startup of mass production of new sports car, and this production system is the result of a collaboration of its engineers. Outer side sheets are joined to inner side sheets by 122 stitch welds totally. And the length is about 2.4meter.

  • PDF

Knowledge of and Compliance with Standard Precautions by Nurses in Intensive Care Unit (중환자실 간호사의 표준주의에 대한 지식과 이행도)

  • Cho, Gwi-Lae;Choi, Jeong-Sil
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.17 no.1
    • /
    • pp.73-81
    • /
    • 2010
  • Purpose: This study was done to identify the intensive care unit nurses' knowledge of and compliance with the standard precautions (universal precaution) as stated in infection control guidelines. Method: From September 14 to September 28, 2006, data were collected via a questionnaire survey from 189 Intensive Care Unit nurses working at three university branch hospitals and one general hospital in Gyeonggi province. Results: The mean knowledge score was 18.8/20.0 (93.9%). The mean compliance score was 3.4/4.0 (85.8%). Two factors influencing compliance were perception of the standard precautions and experience of needle stick injuries over the past year (p<.05). Two factors influencing knowledge were support of co-workers in the use of protective devices and the availability of hand-washing device or waterless alcohol gel (p<.05). Conclusion: In order to improve knowledge and compliance with standard precautions, all factors of importance for knowledge and compliance must be taken into consideration in the clinical work place and in education.

Use of copper shape memory alloys in retrofitting historical monuments

  • El-Borgi, S.;Neifar, M.;Jabeur, M. Ben;Cherif, D.;Smaoui, H.
    • Smart Structures and Systems
    • /
    • v.4 no.2
    • /
    • pp.247-259
    • /
    • 2008
  • The potential use of Cu-based shape memory alloys (SMA) in retrofitting historical monuments is investigated in this paper. This study is part of the ongoing work conducted in Tunisia within the framework of the FP6 European Union project (WIND-CHIME) on the use of appropriate modern seismic protective systems in the conservation of Mediterranean historical buildings in earthquake-prone areas. The present investigation consists of a finite element simulation, as a preliminary to an experimental study where a cantilever masonry wall, representing a part of a historical monument, is subjected to monotonic and quasi-static cyclic loadings around a horizontal axis at the base level. The wall was retrofitted with an array of copper SMA wires with different cross-sectional areas. A new model is proposed for heat-treated copper SMAs and is validated based on published experimental results. A series of nonlinear finite element analyses are then performed on the wall for the purpose of assessing the SMA device retrofitting capabilities. Simulation results show an improvement of the wall response for the case of monotonic and quasi-static cyclic loadings.

The Effect of Protective Socks Combined with Functional Insole on Plantar Foot Pressure in Healthy Adults: A Pilot Study (정상인 대상으로 기능성 인솔과 결합한 보호형 양말이 발바닥 압력에 미치는 영향: 예비 실험 연구)

  • Jung, Do-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.1
    • /
    • pp.147-154
    • /
    • 2018
  • PURPOSE: This study examined the ability of experimental socks combined with a functional insole to reduce plantar foot pressure in healthy subjects. METHODS: The study enrolled 15 subjects. An in-shoe measurement device was used to measure the peak plantar pressure while walking. The peak forefoot, midfoot, and hindfoot plantar pressure data were collected under two conditions: the subjects were wearing their own socks and while they were wearing the experimental socks. The paired t-test was used to determine the differences in peak plantar pressure between the two conditions at all three positions. RESULTS: Wearing the experimental socks resulted in a significantly higher peak plantar pressure in the medial forefoot and midfoot areas than wearing one's own socks (p<.05), and also in significantly lower peak plantar pressure in the medial and lateral hindfoot (p<.05). However, there were no significant differences of peak plantar pressure between experimental and own socks in middle and lateral forefoot (p>.05). CONCLUSION: The experimental socks combined with a functional insole decreased plantar pressure in the hindfoot and supported the medial longitudinal arch. However, it is necessary to change the design and material of the forefoot area in the functional insole to prevent foot ulcer at that location in people with diabetes mellitus.

Comparison of the Operational Speed of Hard-wired and IEC 61850 Standard-based Implementations of a Reverse Blocking Protection Scheme

  • Mnguni, Mkhululi Elvis Siyanda;Tzoneva, Raynitchka
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.740-754
    • /
    • 2015
  • This paper focuses on the reverse blocking busbar protection scheme with aim to improve the speed of its operation and at the same time to increase operational reliability, flexibility and stability of the protection during external and internal faults by implementation of the extended functionality provided by the IEC61850 standard-based protective Intelligent Electronic Devices (IEDs). The practical implementation of the scheme by the use of IEC 61850 standard communication protocol is investigated. The proposed scheme is designed for a radial type of a distribution network and is modeled and simulated in the DigSILENT software environment for various faults on the busbar and its outgoing feeders. A laboratory test bench is built using three ABB IEDs 670 series that are compliant with the IEC 61850 standard, CMC 356 Omicron test injection device, PC, MOXA switch, and a DC power supplier. Two types of the reverse blocking signals between the IEDs in the test bench are considered: hard wired and Ethernet communication by using IEC 61850 standard GOOSE messages. Comparative experimental study of the operational trip response speeds of the two implementations for various traffic conditions of the communication network shows that the performance of the protection scheme for the case of Ethernet IEC 61850 standard-based communication is better.