• 제목/요약/키워드: Protective Structures

검색결과 181건 처리시간 0.023초

콘크리트 구조물의 열화방지를 위한 보호마감 복합화 신기술의 개발 (Development of New Hybrid Technique of Protective Finishing for the Prevention of Deterioration in Concrete Structures)

  • 하기주;최민권;신종학;김기태;홍호용;이영범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.739-744
    • /
    • 2001
  • In this study, experimental research was carried out to develop protective finishing, coating materials and new hybrid technique for deteriorating prevention and high durability in concrete structures. It had sufficiently recommended performance for the protective finishing method of concrete structures through testings. This is more progressive double membrane method than single membrane type designed by conventional method. It was found that this hybrid construction method had very excellent performance to improve the durability of existing concrete structures and attain the beauty of concrete structures.

  • PDF

뉴스초점: 폭발하중을 받는 방호구조물의 계획과 설계 (Planning and Design of Protective Structures under Blast Loading)

  • 변근주;남진원;변재한;김호전
    • 기술사
    • /
    • 제44권5호
    • /
    • pp.36-41
    • /
    • 2011
  • Design of blast resistant structures (protective structures) require the adequate design and construction practices as well as the knowledge of characteristics of the blast loads, behavior of structures and their components under these loads. This paper focuses on how to design and evaluate the structures for blast resistance, and provides principles and discussion on analysis and design capability in protective technology and recommendations.

  • PDF

Effects of unconfined blast on strategic structures and its protective measures

  • Choubey, Bishwajeet;Dutta, Sekhar C.;Hussain, Md. Ahsaan
    • Structural Engineering and Mechanics
    • /
    • 제84권2호
    • /
    • pp.167-180
    • /
    • 2022
  • A strategic structure when exposed to direct hit of conventional bomb/projectile are severely damaged because of large amounts of energy released by the impact and penetration of bomb. When massive concrete slabs suffer a direct hit, the energy released during impact and penetration process are able to easily break up large mass of concrete. When over stressed under such impact of bombs, the concrete structure fails showing brittle behavioural nature. This paper is intended to study and suggest the protective measures for structures used for strategic application by adopting a means to dissipate the large quantum of energy released. To quantitatively evaluate the force, displacement and energy in such scenario, a fine numerical model of the proposed layered structure of different combinations was built in ANSYS programme in which tri-nitrotoluene (TNT) explosive was detonated at penetration depth calculated for GP1000 Lbs bomb. The distinct blast mitigation effect of the proposed structure was demonstrated by adopting various layers/barriers created as protective measures for the strategic structure. The calculated result shows that the blast effect on the structure is potentially reduced due to provision of buster slab with sand cushioning provided as protective measure to the main structure. This concept of layered protective measures may be adopted for safeguarding strategic structures such as Domes, Tunnels and Underground Structures.

확장챔버를 적용한 방호터널 내부의 CFD 해석 기반 폭발압력 평가 (CFD-Based Overpressure Evaluation Inside Expansion Chamber-Applied Protective Tunnels Subjected to Detonation of High Explosives)

  • 신진원;방승기
    • 한국공간구조학회논문집
    • /
    • 제23권1호
    • /
    • pp.25-34
    • /
    • 2023
  • This paper presents a computational fluid dynamics (CFD) analysis to investiagate the effect of expansion chamber on overpressure reduction in protective tunnels subjected to detonation of high explosives. A commercial CFD code, Viper::Blast, was used to model the blast waves in a protective tunnel with a length of 160 m, width of 8.9 m and height of 7.2 m. Blast scenarios and simulation matrix were establihsed in consideration of the design parameters of expansion chamber, including the chamber lengths of 6.1 m to 12.1 m, widths of 10.7 m to 97 m, length to width ratios of 0.0 to 5.0, heights of 8.0 m and 14.9 m, and ratios of chamber to tunnel width of 1.2 to 10.9 m. A charge weight of TNT of 1000 kg was used. The mesh sizes of the numerical model of the protective tunnel were determined based on a mesh convergence study. A parametric study based on the simulation matrix was performed using the proposed CFD tunnel model and the optimized shape of expansion chamber of the considered tunnel was then proposed based on the numerical results. Design recommendations for the use of expansion chamber in protective tunnel under blast loads to reduce the internal overpressures were finally provided.

간이충돌모델을 이용한 파일형 선박충돌방호공의 충돌거동 연구 (A Study on Behaviors of Pile Protective Structures by Simplified Collision Model)

  • 이계희
    • 대한토목학회논문집
    • /
    • 제36권1호
    • /
    • pp.31-38
    • /
    • 2016
  • 논문에서는 파일형 선박충돌방호공의 주요 에너지 소산기구인 파일의 소성힌지와 선수변형에 대한 변형-에너지곡선을 산정하고 이를 이전 연구에서 개발된 간이 충돌모델에 적용하여 매개변수해석을 수행하였다. 고려된 매개변수는 슬래브의 질량, 파일의 수, 선박의 질량 및 충돌속도였으며 이들 매개변수를 변화시키면서 충돌거동을 분석하였다. 연구결과, 충진강관과 비충진강관의 에너지 소산거동이 차이를 파악했고, 슬래브의 관성질량을 조절하여 방호공의 충돌거동을 변화 시킬 수 있는 것으로 나타났다. 따라서 개발된 간이모델은 기본설계나 최적설계에 이용될 수 있을 것이다.

Comparison of classical and reliable controller performances for seismic response mitigation

  • Kavyashree, B.G.;Patil, Shantharama;Rao, Vidya S.
    • Earthquakes and Structures
    • /
    • 제20권3호
    • /
    • pp.353-364
    • /
    • 2021
  • Natural hazards like earthquakes, high winds, and tsunami are a threat all the time for multi-story structures. The environmental forces cannot be clogged but the structures can be prevented from these natural hazards by using protective systems. The structural control can be achieved by using protective systems like the passive, active, semi-active, and hybrid protective systems; but the semi-active protective system has gained importance because of its adaptability to the active systems and reliability of the passive systems. Therefore, a semi-active protective system for the earthquake forces has been adopted in this work. Magneto-Rheological (MR) damper is used in the structure as a semi-active protective system; which is connected to the current driver and proposed controller. The Proportional Integral Derivative (PID) controller and reliable PID controller are two proposed controllers, which will actuate the MR damper and the desired force is generated to mitigate the vibration of the structural response subjected to the earthquake. PID controller and reliable PID controller are designed and tuned using Ziegler-Nichols tuning technique along with the MR damper simulated in Simulink toolbox and MATLAB to obtain the reduced vibration in a three-story benchmark structure. The earthquake is considered to be uncertain; where the proposed control algorithm works well during the presence of earthquake; this paper considers robustness to provide satisfactory resilience against this uncertainty. In this work, two different earthquakes are considered like El-Centro and Northridge earthquakes for simulation with different controllers. In this paper performances of the structure with and without two controllers are compared and results are discussed.

Evaluation of Performance of Protective Surface Coating for Concrete

  • Ahn, Tae Song;Cheong, Hai Moon
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.1061-1066
    • /
    • 2003
  • Chloride penetration into concrete is the main cause of the steel corrosion in concrete structures exposed to chloride-rich environments. Protective surface coatings are increasingly being applied to concrete structures to reduce chloride penetration. In this study, the performance of various surface coatings was evaluated. Most coatings showed good results for the various tests of the performance evaluation. Surface coatings can delay deterioration such as chloride-induced reinforcing bar corrosion effectively.

  • PDF

파일형 선박충돌방호공에 대한 간이충돌모델의 개발과 검증 (Development and Verification of Simplified Collision Model for Pile Protective Structures)

  • 이계희
    • 한국해안·해양공학회논문집
    • /
    • 제28권1호
    • /
    • pp.7-12
    • /
    • 2016
  • 본 연구에서는 선박충돌로부터 교량을 방호하는 파일형 선박충돌방호공과 충돌선박의 간이충돌모델을 개발하고 이를 검증하였다. 선박은 선수의 비선형반력을 고려하여 모델링하였다. 충돌방호공의 모델은 파일에서 상부슬래브의 하단과 지중에 2개의 소성힌지가 발생하는 것으로 구성하였다. 충돌중 발생하는 운동에너지와 위치에너지 및 변형에너지를 고려하여 운동방정식을 유도하고 이를 해석하는 시스템을 개발하였다. 선박과 구조물에 대한 정밀 충돌해석을 수행하여 개발된 간이모델이 충돌거동을 정확히 모사할 수 있음을 보였다.

구리 보호층을 이용한 전해에칭에서의 다층구조 제작 (Fabrication of Multilayered Structures in Electrochemical Etching using a Copper Protective Layer)

  • 신홍식
    • 한국기계가공학회지
    • /
    • 제18권2호
    • /
    • pp.38-43
    • /
    • 2019
  • Electrochemical etching is a popular process to apply metal patterning in various industries. In this study, the electrochemical etching using a patterned copper layer was proposed to fabricate multilayered structures. The process consists of electrodeposition, laser patterning, and electrochemical etching, and a repetition of this process enables the production of multilayered structures. In the fabrication of a multilayered structure, an etch factor that reflects the etched depth and pattern size should be considered. Hence, the etch factor in the electrochemical etching process using the copper layer was calculated. After the repetition process of electrochemical etching using copper layers, the surface characteristics of the workpiece were analyzed by EDS analysis and surface profilometer. As a result, multilayered structures with various shapes were successfully fabricated via electrochemical etching using copper layers.

Protective System from Medical Needle-sticks. Part II: Evaluation of Woven Structures and Bifid Needles

  • Seyam, Abdelfattah M.;Turner, LaDawnya C.;Banks-Lee, Pamela
    • Fibers and Polymers
    • /
    • 제4권3호
    • /
    • pp.129-134
    • /
    • 2003
  • We have shown in Part I [1] of this study that medical needle-stick injuries are causing serious health problems to healthcare personnel and other professionals that require the attention of healthcare and textile researchers to develop new protective systems. Responding to such need, a needle force measurement device that is capable of measuring dynamic forces experienced by medical needles during needle penetration through protective articles was developed and described in part I. This paper reports the results of evaluation of protective woven fabrics from high performance fibers and standard and bifid medical needles using the force measurement system. The woven fabrics varied in cover factor, number of layers, and orientation angle. Standard and bifid needles with different gap widths were used to evaluate the resistance of the fabric to needle penetration.