• 제목/요약/키워드: Protective Performance

검색결과 510건 처리시간 0.024초

Prospect on IMO's Performance Standards for Protective Coatings (PSPC) Regulation for Ship's Water Ballast Tanks

  • Baek, Kwang Ki
    • Corrosion Science and Technology
    • /
    • 제7권4호
    • /
    • pp.219-223
    • /
    • 2008
  • In 2006, as a means to minimize early corrosion failure of ships, thus to enhance marine safety, International Maritime Organization (IMO), proposed a mandatory regulation for Performance Standards for the Protective Coatings (PSPC) for ballast tanks of newly built ships to satisfy 15 years of target useful life. In this regulation, several unprecedented strict rules are adopted as minimum, mandatory requirements for protective coatings of ship's water ballast tanks, and all type of ships sailing international sea are subjected to this regulation which is to be effective as early as June of 2008. The PSPC addresses many technical issues in the areas of surface pretreatment (primary and secondary), coating materials, coating application procedure and inspection as well as necessary documentation. The PSPC rules are new and unproven concepts, which calls for rigorous incorporation of reality-based evidences currently available, since there are no practical experiences in terms of the validity of the PSPC rules. There has been much controversy surrounding these regulations and considerable effort has been made by both shipyards and ship owners alike to achieve a performance standard for ballast tank coatings, which is acceptable to all. In this paper, the background and overview of the PSPC rules are given, and several issues in the PSPC are reviewed as a base to achieve robustness of the proposed PSPC, which will serve as a means to minimize early corrosion and to ensure 15 year target useful life of ships.

Effect of Retaining Preconsruction Primer (PCP) on the Quality of High Performance Protective Coatings Systems

  • Chung, M.K.;Baek, K.K.;Lee, H.I.;Lee, C.H.;Shin, C.S.
    • Corrosion Science and Technology
    • /
    • 제3권2호
    • /
    • pp.59-66
    • /
    • 2004
  • In construction of new ships and large steel bridges in Korea, pre-construction primers (PCP), also known as shop primer, are routinely used and retained as an integral part of the protective coating system. Retention of PCP's can significantly reduce building schedule and cost. Retaining PCP through the so-called "sweep blasting" procedure eliminates or minimizes the necessity of a second blast operation, thus shortening overall schedule as well as reducing labor cost and hazardous waste disposal cost. This study evaluates the feasibility of retaining PCP as the part of primer for high performance protective coating systems applied to ships' hull, bottom and ballast tanks. Upon proving that the retention of the PCP is a viable option, the process of coating application can he improved significantly in terms of cost and working schedule of new ships and large steel bridges. Results indicate that use of the PCP via sweeping blasting in conjunction with standard high performance protective coating systems does not degrade the overall performance of the coating systems. At the same time, it is also highly recommended that the secondary surface preparation should consist of grit blasting of weld burnt and other damaged areas to SSPC SP-IO grade (Sa 2.5 Gr.), Near White Blast Cleaning with proper application and attention to detail.

수포작용제 방호성능이 향상된 선택투과막 제조 (Preparation of Selectively Permeable Membrane Materials with Enhanced Protective Capability against Blister Agents)

  • 권태근;김진원;강재성;박현배;이해완;서현관
    • 멤브레인
    • /
    • 제24권2호
    • /
    • pp.167-175
    • /
    • 2014
  • 수증기 투과성과 DMMP 방호성능을 가지는 cellulose acetate butyrate (CAB)/polyethyleneimine (PEI) 기반의 선택투과막에 대해 여러가지 첨가제를 적용하여 CEES에 대한 방호성능 개선을 시도하였다. 시험결과, CAB/PEI 기반의 선택투과막은 수증기 투과성은 그대로 유지하면서(${\geq}1,800g/m^2/day$), CEES에 대한 방호성능의 개선을 보여주었다($7.1{\sim}11.5{\mu}g/cm^2{\cdot}24hr$). 이 중, $Ag^+$ 이온과 이온교환수지 혼합물을 포함한 CAB/PEI 선택투과막에서 가장 우수한 방호성능을 확보하였다. 그리고 시험한 모든 선택투과막은 생물학작용제를 모사할 수 있는 다양한 크기의 에어로졸 입자($0.005{\sim}3{\mu}m$)에 대해서도 방호성능을 가짐을 확인하였다.

다목적 기능을 가진 수목보호패드의 성능 연구 (Performance Research of a Multi Functional Tree Protection Pad)

  • 정용조;이경연
    • 한국환경복원기술학회지
    • /
    • 제21권1호
    • /
    • pp.133-143
    • /
    • 2018
  • In spite of the growing importance of landscaping trees, the rate of flawed and withered trees damaged by pest, disease, drought or frost is increasing. In order to evaluate the performance of the Tree Protective Pad, which are developed to reduce the failure ratio in landscape planting, the tree protective pad for 'digging', 'pest controlling', and 'insulating' are tested based on the five functional criteria; moisturizing effect, wither preventive effect, pest and disease control, thermal effect, tensile strength, and environmental performance. The result of this study is as follows. The moisturizing effect of the tree protective pad for digging is found to be outstanding. According to the result of testing the pad on trees, in particular, it is better than jute tape in wither preventive effect, which means it is expected to prevent flaw and wilt from planting during the improper seasons like summertime. The experiment of installing the protective tree pad for pest controlling to the trunk of Quercus mongolica shows that preventive effect of the pad from diseases and insects is superior, and it also has economical effect by reducing the use of agricultural chemicals. The comparative test of the pad for insulating and jute tape proves that the temperature of the pad is about $2^{\circ}C$ higher than outside. The rate of tensile strength and biodegradation of the pad exceeds the optimal level, so it is revealed that the pad may be the work efficient and environment-friendly product. Likewise, by timely irrigating trees, the tree protective pad economically prevents trees from pest, disease,drought or frost, which may be caused by improper seasonal or delayed planting. As a means of reducing the flaw and facilitating the growth of trees, the exceptional performance of the pad is expected to effectively used in landscape planting and management.

섬유보강 콘크리트 방호벽의 방호성능 향상 검토 (Evaluation of Protective Performance of Fiber Reinforced Concrete T-Wall)

  • 이인철;김홍섭;남정수;김석봉;김규용
    • 한국건축시공학회지
    • /
    • 제13권5호
    • /
    • pp.465-473
    • /
    • 2013
  • 콘크리트는 충격 및 폭발에 대한 저항능력이 우수한 재료이지만, 국부적인 파괴가 발생하는 한계가 있다. 콘크리트의 방호성능 향상기법은 기존에는 부재의 두께를 증가시키는 것이었으나, 이는 공간의 활용에 있어 비효율 적이다. 최근에는 섬유보강 콘크리트는 콘크리트 자체의 휨인성을 증가시켜, 충격 및 폭발에 대한 저항능력을 향상시킨 방호재료의 개발 및 적용이 고려되고 있다. 본 연구에서는 섬유보강 콘크리트 및 모르타르에 대하여 고속 비상체의 충돌에 의한 내충격 성능을 평가하였으며, 그 결과를 바탕으로 방호벽으로 활용할 수 있는 콘크리트 T-wall을 제작하여 155 mm 포탄의 파편에 대한 방호성능을 검토하였다. 그 결과, 섬유보강으로 인한 휨 인성의 향상은 고속 비상체의 충돌에 의한 배면박리를 억제하는 것으로 나타났으며 155 mm 포탄의 파편 충돌에 있어 배면균열 및 표면의 콘크리트의 박락 등이 억제되어 섬유보강으로 인하여 방호벽의 성능 향상 및 부재두께를 감소할 수 있을 것으로 판단된다.

보호복 관련 국내·외 표준에 대한 탐색적 조사 - ISO, ASTM, CEN, KS를 중심으로 - (An Exploratory Study on Domestic and International Protective Clothing Standard - Focused on ISO, ASTM, CEN, KS -)

  • 한설아;남윤자
    • 한국의류산업학회지
    • /
    • 제10권1호
    • /
    • pp.92-100
    • /
    • 2008
  • When designing protective clothing, there are something to be considered such as physiological feature of human body, acting range not to restrict physical activity, and effectiveness of material. Because the primary objective of protective clothing is to protect human body from danger and it is designed through complex designing process not likely general clothing design. However, current evaluation techniques-such as the ISO, the ASTM and the CEN, and KS-provide only the standard to evaluate the primary feature of material (testing, performance requirements, material specification, selection and application, test and care, and so on). There are no standard to evaluate influence for the human body while protective clothing put on. Especially, in Korea, there is KS to evaluate protective clothing, but it is partially translated version from ISO because of lack of core technology about this field. However, developed countries recognize it is new competitive means in the time of Global Standards and they are competing to make their own standard to global standard for the protective clothing. Therefore, it can be great opportunity for Korean clothing and textile industry to revitalize if focusing on research and development for protective clothing design based on physical activity of human body, fit evaluation technique and sizing which is currently no global standard for it and developing our standard to global standard.

바리스터와 LC필터를 조합한 교류 전원용 서지보호장치 (Surge Protective Device Combined with Varistor and LC Filter on AC Power Circuits)

  • 이복희;이경옥;안창환;이승칠;박정웅
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권4호
    • /
    • pp.109-116
    • /
    • 1997
  • I본 논문은 교류 전원용 바리스터와 LC필터를 조합한 서지 보호장치에 대해서 기술하였다. 지금까지 교류 전류용 서지 보호장치로써 바리스터만이 주로 사용되어 왔으나, 이것은 급상승하고 높은 잔류전압 때문에 보호되어야 할 장비에 해로운 결과를 초래하는 경우도 있다. 따라서 본 연구에서는 교류 전원용 서지 보호장치의 차단 성능을 향상시키기 위하여 바리스터와 LC필터로 구성된 조합형 서지 보호장치를 설계.제작하였다. 그리고 서지 보호장치의 동작특성과 차단 성능의 분석에 대한 실험을 1.2/50[$\mu\textrm{s}$] 임펄스 발생기를 적용하여 수행하였다. 결론적으로 본 연구에서 제시한 조합형 서지보호장치는 서지 전압을 더욱 낮게 제한할 수 있고, dV/dt의 값을 매우 낮은 값으로 감소시키며, LC필터에 의한 출력단의 고주파 전압을 효과적으로 감쇠시킬수 있기 때문에 전자시스템의 손상과 전도를 더욱 더 효과적으로 방지할 수 있다.

  • PDF

수소제트화재에 대한 특수 방화복의 열 방호 성능시험 평가 (Assessment of Thermal Protection Performance of Firefighting Garments for Hydrogen Jet Fire)

  • 윤웅기;박병직;김양균;강성욱;임옥근
    • 한국수소및신에너지학회논문집
    • /
    • 제35권3호
    • /
    • pp.310-317
    • /
    • 2024
  • In this study, Aimed to develop technology to ensure the safety of firefighters responding to hydrogen incidents and to review the performance of protective super absorbent polymer (SAP) that could help maintain the thermal protection performance of equipment with protective properties. Tests were conducted, including bench-scale and full-scale thermal exposure tests, to review the protective performance of SAP using firefighting garments commonly used by firefighters. The results showed that without SAP application, 2nd degree burn areas were measured at 9.4%, and 3rd degree burn areas at 7.7%. In contrast, when SAP was applied, the percentage of 2nd degree burn areas decreased to 7% on the lower body, and there was no temperature rise causing 3rd degree burns. Therefore, it is expected that by applying SAP to the outer surface of firefighter garments, even under temporarily high temperature conditions such as hydrogen jet flames, thermal damage to firefighters could be protected for a certain period.

Protective System from Medical Needle-sticks. Part II: Evaluation of Woven Structures and Bifid Needles

  • Seyam, Abdelfattah M.;Turner, LaDawnya C.;Banks-Lee, Pamela
    • Fibers and Polymers
    • /
    • 제4권3호
    • /
    • pp.129-134
    • /
    • 2003
  • We have shown in Part I [1] of this study that medical needle-stick injuries are causing serious health problems to healthcare personnel and other professionals that require the attention of healthcare and textile researchers to develop new protective systems. Responding to such need, a needle force measurement device that is capable of measuring dynamic forces experienced by medical needles during needle penetration through protective articles was developed and described in part I. This paper reports the results of evaluation of protective woven fabrics from high performance fibers and standard and bifid medical needles using the force measurement system. The woven fabrics varied in cover factor, number of layers, and orientation angle. Standard and bifid needles with different gap widths were used to evaluate the resistance of the fabric to needle penetration.

여성 노인을 위한 낙상충격 보호팬츠 개발 및 평가 (Development and Evaluation of Fall Impact Protective Clothing for the Elderly Women)

  • 박정현;이진숙;이정란
    • 한국의류산업학회지
    • /
    • 제20권5호
    • /
    • pp.569-582
    • /
    • 2018
  • The purpose of this study is to verify the impact protection performance and to evaluate the activity, design, fit, and pad characteristics of the fall impact protection clothing for elderly women. The protective clothing was designed as pants type and underwear type, and an impact protection pad in the form of a tightly connected regular hexagon piece was inserted in the hip and hip joints. The pad was made of two kinds of foam single pad and foam and gel combination pad so that they could be inserted into pants type and underwear type, respectively. The results of the shock absorption performance of the fall impact protective clothing showed that when the impact force of 4601N was applied to the pants type protective clothing, the impact force was reduced by 29% in the foam pad type and 26% in the gel and foam pad type. When the force of 5113N was applied to the underwear type, it decreased by 40% in the foam pad type and by 34% in the gel and foam pad type. As a result of wearing evaluation of subject group, it was found that fit and activity of underwear type was better than that of pants type. Foam pad type was evaluated to be lighter than gel and foam pad type in both the subject and the expert group and the gel and foam pad was evaluated to be more flexible in the expert group.