• Title/Summary/Keyword: Protection time

Search Result 2,887, Processing Time 0.028 seconds

Optimal Operation Algorithm of Protection Devices in Distribution Systems With PV System (대용량 태양광전원이 연계된 배전선로에 있어서 보호협조기기의 최적 운용알고리즘)

  • Kwon, Soon-hwan;Lee, Hu-dong;Nam, Yang-hyun;Rho, Dae-seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.17-26
    • /
    • 2018
  • If a photovoltaic (PV) system is installed in a primary feeder interconnected with the PV system, bi-directional power flow can occur, and then, the magnitude and direction of the fault current can change, depending on the fault location and point of common coupling (PCC) of the PV system, and the time current curve (TCC) cannot be properly coordinated between protection devices. Also, it is difficult to obtain a proper time interval for protection devices because the conventional setting approach is applied, even though the PV system is installed and operating. Therefore, this paper presents three operation modes considering the operational conditions of the PV system to obtain setting values for protection devices. Based on the mode, this paper proposes an algorithm to calculate the optimal protection coordination time interval according to the introduction capacity of the PV system. In addition, this paper performs modelling of a distribution system with the PV system and protection devices by using Off-DAS S/W, and analyzes the characteristics of the time interval between the protection devices, such as substation relays, reclosers, customer relays, and PV customer relays. The simulation results confirmed that the proposed operational modes and setting-value algorithms are useful and effective for protection coordination in a distribution system for a PV system.

Hierarchical Channel Coding Scheme Using UEP Method for Rain-Attenuation Compensation in Satellite Communication (위성통신에서 강우 감쇠 보상을 위한 UEP 방식의 계층적 부호화 방식)

  • Jung Ji-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.9 s.112
    • /
    • pp.795-803
    • /
    • 2006
  • In this paper, we studied hierarchical channel coding scheme using unequal error protection method fur consecutively broadcastingservice under the rain attenuation of Ka band satellite broadcasting. Unlike time-sharing methods, which are design for different channel coding scheme in according to different modulation, unequal error protection method is made in such way that minimum distance between signals are different for importance of signals with same modulation. Consequently we proposed optimal method according to performance analysis.

A Study on GCNMOS-based ESD Protection Circuit Using Floating-Body Technique With Low Trigger Voltage (Floating-Body기술을 이용한 낮은 트리거 전압을 갖는 GCNMOS 기반의 ESD 보호회로에 관한 연구)

  • Jeong, Jun-Mo
    • Journal of IKEEE
    • /
    • v.21 no.2
    • /
    • pp.150-153
    • /
    • 2017
  • In this paper, a structure of GCNMOS based ESD protection circuit using floating-body technique is proposed. TCAD simulation of Synopsys was used to compare with the conventional GGNMOS and GCNMOS. Compared with the conventional GCNMOS, the proposed ESD protection circuit has lower trigger voltage and faster turn-on-time than conventional circuit because of the added NMOSFET. In the simulation result, the triggering voltage of the proposed ESD protection circuit is 4.86V and the turn-on-time is 1.47ns.

Real-Time HD Watermarking System in DTV environment

  • Hahm Sangjin;Lee Keunsik;Park Keunsoo
    • Journal of Broadcast Engineering
    • /
    • v.10 no.2
    • /
    • pp.131-138
    • /
    • 2005
  • High-quality digital broadcasting contents are susceptible to illegal copy and unauthorized redistribution, which makes broadcasters difficult to protect valuable media assets. So, broadcasters and content providers need the technology for copyright protection of professional digital content. Digital watermarking technology is one of the most actively developed solutions for the copyright protection. This paper suggests the requirements of watermarking technology in DTV(Digital TV) environment for copyright protection and shows the developed real-time watermark embedding/detecting system for HD(High Definition)/SD(Standard Definition) video and experimental results of the system against watermark attack tests. Our watermarking system meets the watermarking requirements of invisibility, robustness and security of DTV environment.

SEQUENTIAL ESTIMATION OF THE MEAN VECTOR WITH BETA-PROTECTION IN THE MULTIVARIATE DISTRIBUTION

  • Kim, Sung Lai;Song, Hae In;Kim, Min Soo;Jang, Yu Seon
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.26 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • In the treatment of the sequential beta-protection procedure, we define the reasonable stopping time and investigate that for the stopping time Wijsman's requirements, coverage probability and beta-protection conditions, are satisfied in the estimation for the mean vector ${\mu}$ by the sample from the multivariate normal distributed population with unknown mean vector ${\mu}$ and a positive definite variance-covariance matrix ${\Sigma}$.

Analysis on Durability Performance Enhancement and Economical Efficiency through Chloride Protection for Concrete Structures (콘크리트 구조물의 염해도장을 통한 내구성능 향상 및 경제적 효과분석)

  • Chai, Won-Kyu;Kim, Seong-Heon;Son, Young-Hyun;Park, Ju-Won;Lee, Cheung-Bin
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.155-160
    • /
    • 2010
  • In this study, detailed assessment for durability performance were performed on the chloride protected concrete structures to investigate the effectiveness of chloride protection. And economical efficiency for the chloride protected concrete structures were studied by LCC(Life Cycle Cost) analysis. In the comparison result of the first section repair time, it was found that the chloride protected concrete structures was economical better than the non-protected concrete structures in the long term. According to the analysis result of the accumulated chloride concentration by used time and chloride ion concentration by depth, it can be seen that the permeation through time from chloride has increased two times in the chloride protected concrete structures.

Advanced Cathodic Protection Modeling Associated with Coating Degradation Conditions

  • Im, Gwan-Jin;Kim, Ki-Joon;Lee, Myung-Hoon
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.177-183
    • /
    • 2009
  • There are two effective methods in use to protect ship ballast tank against corrosion. One is paint coating and the other cathodic protection(CP). The conventional cathodic protection design has mainly relied on the expert's experience. During the last two decades computer modeling has been significantly developed as an advanced design technology for cathoidic protection systems not only for ships, but also for offshore structures. However the present computer modeling of cathodic protection systems have some limitations simulating corrosion in the ballast tank with a deteriorated coating. In this study, "coating breakdown factor" considering coating degradation states with time has been attempted to improve the cathodic protection modeling using the data from literatures.

A New Protection Strategy of Impressed Current Cathodic Protection for Ship

  • Oh, Jin-Seok;Kim, Jong-Do
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.592-596
    • /
    • 2004
  • Corrosion is never avoided in the use of materials with various environments. The underwater hull is normally protected against rusting by several coatings of anti-corrosive paint. The purpose of ICCP(Impressed Current Cathodic protection) system is to eliminate the rusting or corrosion, which occurs on metal immersed in seawater. The anode of ICCP system is controlled by an external DC source with converter. The function of anode is to conduct the protective current into seawater. The proposed algorithm includes the harmonic suppression control strategy and the optimum protection strategy and has tried to test the requirement current density for protection, the influence of voltage, the protection potential. This paper was studied the variation of potential and current density with environment factors, time and velocity, and the experimental results will be explained.

The Performance of Cathodic Protection with ICCP

  • Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1286-1290
    • /
    • 2004
  • This paper describes the anti-corrosion system on underwater structures of ships. Metals and alloys have several positions in the series such as immunity, corrosion and passivity. The iron potential has to change from the corrosion position to the anodic protection or cathodic protection for preventing corrosion by providing corrosion protection system such as ICCP(Impressed Current Cathodic Protection). The purpose of ICCP system is to eliminate the rusting or corrosion, which occurs on metal immersed in water. The system includes a power supply unit, which consists of a transformer, a converter. a controller, etc. This paper presents the protection performance of ICCP under dynamic condition such as velocity. The variation of potential and current density with time and environment factors are also described Finally, the experimental results will be explained and analysed.

Improving Motor Protection Using Thermal Model (열 모델을 이용한 전동기 보호성능 개선)

  • Chang, Choong-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.473-479
    • /
    • 2015
  • Thermal relays are sometimes used instead of long time overcurrent relays for motor protection. But, it is difficult for any relay design engineer to adequately approximate motor heating curves which represent the average of a difficult-to-define thermal zone. Thermal relays frequently may not provide sufficient protection on heavy overloads. Digital multifunction relays are microprocessor-based devices. These relays offer highly reliable and advanced protection of motors. If a situation can be mathematically described, the microprocessor in a digital relay can be programmed to tackle that problem. Today's motor protection is accomplished with digital protective relays. Digital relays offer additional, highly important features to complement protection. The best way to prevent short in motor is to not overheat and degrade the insulation.