• 제목/요약/키워드: Protection range

검색결과 990건 처리시간 0.022초

송전선로 보호용 디지털 지능형 거리계전기 (Digital Adaptive Distance Relay for Transmission Line Protection)

  • 정창호;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권9호
    • /
    • pp.411-416
    • /
    • 2001
  • Distance relay is the most widely used in transmission line protection because it is applicable not only as main protection but also as back-up protection. However, the protection range of the distance relay is always fixed in the unchangeable operating range while the power system varies, and therefore the distance relay is the device that is the highly influenced by the power system changes. In this regard, this paper describes an approach to minimize the mal-operation of the distance relay due to the power system changes through changing protection range of the distance relay into optimal condition in response to the load variation and power system condition. Also mal-function of the distance repay in case of high resistance ground faults could be minimized through modeling the protection range into quadratic function.

  • PDF

A Privacy-protection Device Using a Directional Backlight and Facial Recognition

  • Lee, Hyeontaek;Kim, Hyunsoo;Choi, Hee-Jin
    • Current Optics and Photonics
    • /
    • 제4권5호
    • /
    • pp.421-427
    • /
    • 2020
  • A novel privacy-protection device to prevent visual hacking is realized by using a directional backlight and facial recognition. The proposed method is able to overcome the limitations of previous privacy-protection methods that simply restrict the viewing angle to a narrow range. The accuracy of user tracking is accomplished by the combination of a time-of-flight sensor and facial recognition with no restriction of detection range. In addition, an experimental demonstration is provided to verify the proposed scheme.

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

정전위법에 의한 해상풍력 타워 구조물용 강재의 음극방식을 위한 최적방식전위 결정 (Determination of optimum protection potential for cathodic protection of offshore wind-turbine-tower steel substructure by using potentiostatic method)

  • 이정형;정광후;박재철;김성종
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권3호
    • /
    • pp.230-237
    • /
    • 2017
  • 본 연구에서는 해상풍력 타워 지지구조물용 강재인 S355ML 강에 대하여 전기화학적 기법으로 전기방식 설계에 필요한 최적 방식전위를 규명하고자 하였다. 동전위분극 실험 결과, 양극분극 곡선 상에서는 부동태 구간은 존재하지 않으며, 음극분극 곡선 상에는 용존산소환원반응에 의한 농도분극 구간과 수소가스 발생에 의한 활성화분극 구간이 관찰되었다. 음극방식 시 방식전위에 해당하는 농도분극 구간은 약 - 0.72 V ~ - 1.0 V의 전위 구간인 것으로 확인되었다. 다양한 전위에서 정전위 실험을 실시한 결과 전류밀도 변화는 시간에 따라 안정화되는 경향을 나타냈다. 1200초 동안 정전위 실험 후 주사전자현미경과 3D 분석 현미경을 이용한 시험편 표면 분석 결과, 양극분극 전위에 해당하는 0 V ~ - 0.50 V의 전위구간에서는 양극용해반응에 의한 부식손상이 관찰되었다. 이에 반해 음극분극 전위 영역에서는 대체적으로 손상이 없는 양호한 표면을 유지하였으며 석회질 피막 형성을 확인할 수 있었다. 연구결과, 농도분극 영역에 해당하는 - 0.8 V ~ - 1.0 V의 전위영역이 S355ML 강의 외부전원법에 의한 음극방식 적용 시 최적 방식 전위 구간으로 사료된다.

선박용 고강도 Al합금(5456-H116)의 최적 방식 전위결정에 관한 연구 (Investigation on optimum protection potential of high-strength Al alloy(5456-H116) for application in ships)

  • 김성종;고재용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.157-168
    • /
    • 2006
  • Recently, interest in using Al alloys in ship construction instead of fiber-reinforced plastic (FRP) has increased because of the advantages of A) alloy ships over FRP ships, including high speed, increased load capacity. and ease of recycling. This paper investigated the mechanical and electrochemical properties of Al alloys in a slow strain rate test under various potential conditions. These results will provide reference data for ship design by determining the optimum protection potential regarding hydrogen embrittlement and stress corrosion cracking. In general, Al and Al alloys do not corrode on formation of a film that has resistance to corrosion in neutral solutions. In seawater, however, $Cl^-$ ions lead to the formation and destruction of a Passive film. In a potentiostatic experiment. the current density after 1200 sec in the Potential range of $-0.68\~-1.5\;V$ was low. This low current density indicates the protection potential range. Elongation at an applied potential of 0 V was high in this SSRT. However, corrosion protection under these conditions is impossible because the mechanical properties are worse owing to decreased strength resulting from the active dissolution reaction in parallel parts of the specimen. A film composed of $CaCO_3\;and\;Mg(OH)_2$ confers corrosion resistance. However, at potentials below -1.6 V forms non-uniform electrodeposition coating, since there is too little time to form a coating. Therefore, we concluded that the mechanical properties are poor because the effect of hydrogen gas generation exceeds that of electrodeposition. Comparison of the maximum tensile strength, elongation, and time to fracture indicated that the optimum protection potential range was from -1.45 to -0.9 V (SSCE).

Measuring Thermo-luminescence Efficiency of TLD-2000 Detectors to Different Energy Photons

  • Xie, Wei-min;Chen, Bao-wei;Han, Yi;Yang, Zhong-Jian
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.179-183
    • /
    • 2016
  • Background: As an important detecting device, TLD is a widely used in the radiation monitoring. It is essential for us to study the property of detecting element. The aim of this study is to calculate the thermo-luminescence efficiency of TL elements. Materials and Methods: A batch of thermo-luminescence elements were irradiated by the filtered X-ray beams of average energies in the range 40-200 kVp, 662 keV $^{137}Cs$ gamma rays and then the amounts of lights were measured by the TL reader. The deposition energies in elements were calculated by theory formula and Monte Carlo simulation. The unit absorbed dose in elements by photons with different energies corresponding to the amounts of lights was calculated, which is called the thermo luminescent efficiency (${\eta}^{(E)}$). Because of the amounts of lights can be calculated by the absorbed dose in elements multiply ${\eta}^{(E)}$, the ${\eta}^{(E)}$ can be calculated by the experimental data (the amounts of lights) divided by absorbed dose. Results and Discussion: The deviation of simulation results compared with theoretical calculation results were less than 5%, so the absorbed dose in elements was calculated by simulation results in here. The change range of ${\eta}^{(E)}$ value, relative to 662 keV $^{137}Cs$ gamma rays, is about 30% in the energy range of 33 keV to 662 keV, is in accordance by the comparison with relevant foreign literatures. Conclusion: The ${\eta}^{(E)}$ values can be used for updating the amounts of lights that are got by the direct ratio assumed relations with deposition energy in TL elements, which can largely reduce the error of calculation results of the amounts of lights. These data can be used for the design of individual dosimeter which used TLD-2000 thermo-luminescence elements, also have a certain reference value for manufacturer to improve the energy-response performance of TL elements by formulation adjustment.

A Room-Corner Fire Model을 적용한 건축내장재의 화재확산 특성 평가(1)

  • 김운형
    • 방재기술
    • /
    • 통권24호
    • /
    • pp.32-39
    • /
    • 1998
  • A room-corner fire scenario of ISO 9705 with flame spread model developed by Quintiere is applied to the interior finish materials to show the sensitivity of properties derived from AST, E-1321 and ASTM E-1354 is investigated and various range of thermal properties by the author were analyzed in the model. There are including flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The time for total energy release rate to reach 1MW is examined. Though some areas are neede for improvements, The model appears to predict good results with all the range of input properties and could be

  • PDF

발전기보호반을 위한 IED의 설계에 관한 연구 (A Study on Design of IED for Generator Protection Panel)

  • 박철원;박성완
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.133-138
    • /
    • 2013
  • A large generator is an important role in transferring an electric power to power system. The IEDs of large generator often use microprocessor technology to obtain a digital relay system with a wide range of measuring, protection, control, monitoring, and communication functions. However, all generator protection and control systems in Korea imported from abroad and are being operated. In order to reduce the large expense and improve the reliable operation, development of generator protection and control system by domestic technology is required. This paper deals with the design of the IED of generator protection panel for development of generator protection and control system. The major emphasis of the paper will be on the description of hardware and signal processing test results and measurement accuracy of the prototype IED. By developing of generator IED based on DSP and microprocessor, replacement of the generator protection panel imports are expected to be effective.

일부 반면형 호흡기 보호구에 대한 용접작업장에서의 Workplace Protection Factors(WPF) 평가 (Evaluation of Workplace Protection Factors for Some Half-Facepiece Respirators in Welding Workplace)

  • 변상훈;나명채;김현욱;임호섭
    • 한국산업보건학회지
    • /
    • 제9권1호
    • /
    • pp.14-22
    • /
    • 1999
  • This study was conducted to evaluate workplace protection factors(WPF) for two half-facepiece respirators (HR-1, HR-2) in welding workplace and to provide data on the workplace performance of negative-pressure, half-facepiece respirators against airborne particulate contaminants. The outside iron oxide(Fe2O3) concentration of welding fume for the respirator HR-1 ranged from 0.177 to $12.508mg/m^3$ with a geometric mean of $1.118mg/m^3$ and the HR-2 respirator showed a iron oxide range of 0.500 to $3.494mg/m^3$ with a geometric mean of $1.082mg/m^3$. But the inside oxide concentration of welding fume for the respirator HR-1 ranged from 0.002 to $0.364mg/m^3$ with a geometric mean of $0.019mg/m^3$ and the HR-2 respirator showed a iron oxide range of 0.012 to $0.639mg/m^3$ with a geometric mean of $0.041mg/m^3$. The iron oxide inside concentrations were significantly less than $5mg/m^3$(TLV) for both of respirators. The WPF were ranged from 3 to 3744 with a geometric mean of 60 for HR-1 and range from 2 to 129 a geometric mean of 26 for HR-2. And, in this study, the 5th percentile of the workplace protection factors for half-facepiece aspirators (HR-1, HR-2) were 11.2 and 7.1, respectively. The correlation relationship between the Quantative Fit Factors(QNFT) and the WPF for half-mask negative pressure respirators were 0.099 and 0.460.

  • PDF

소형선박용 Al-Mg 합금의 해양환경 중 최적 방식 전위결정에 관한 연구 (Investigation on optimum protection potential of Al-Mg alloy for small ship application in sea water solution)

  • 김성종;장석기;김정일;고재용
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.23-24
    • /
    • 2005
  • This paper investigated the mechanical and electrochemical properties of Al alloys in a slow strain rate test under various potential conditions. In general, Al and Al alloys do not corrode on formation of a film that has resistance to corrosion in neutral solutions. In seawater, however, $Cl^-$ ions lead to the formation and destruction of a passive film. In a potentiostatic experiment, the current density after 1200 sec in the potential range of $-0.68{\sim}-1.5 V$ was low. Comparison of the maximum tensile strength, elongation, and time to fracture indicated that the optimum protection potential range was from -1.5 to -0.7 V(SSCE).

  • PDF