• Title/Summary/Keyword: Protection of trace

Search Result 61, Processing Time 0.024 seconds

The protective effects of trace elements against side effects induced by ionizing radiation

  • Hosseinimehr, Seyed Jalal
    • Radiation Oncology Journal
    • /
    • v.33 no.2
    • /
    • pp.66-74
    • /
    • 2015
  • Trace elements play crucial role in the maintenance of genome stability in the cells. Many endogenous defense enzymes are containing trace elements such as superoxide dismutase and metalloproteins. These enzymes are contributing in the detoxification of reactive oxidative species (ROS) induced by ionizing radiation in the cells. Zinc, copper, manganese, and selenium are main trace elements that have protective roles against radiation-induced DNA damages. Trace elements in the free salt forms have protective effect against cell toxicity induced by oxidative stress, metal-complex are more active in the attenuation of ROS particularly through superoxide dismutase mimetic activity. Manganese-complexes in protection of normal cell against radiation without any protective effect on cancer cells are more interesting compounds in this topic. The aim of this paper to review the role of trace elements in protection cells against genotoxicity and side effects induced by ionizing radiation.

Trace Mineral Nutrition in Poultry and Swine

  • Richards, James D.;Zhao, Junmei;Harrell, Robert J.;Atwell, Cindy A.;Dibner, Julia J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.11
    • /
    • pp.1527-1534
    • /
    • 2010
  • Trace minerals such as zinc, copper, and manganese are essential cofactors for hundreds of cellular enzymes and transcription factors in all animal species, and thus participate in a wide variety of biochemical processes. Immune development and response, tissue and bone development and integrity, protection against oxidative stress, and cellular growth and division are just a few examples. Deficiencies in trace minerals can lead to deficits in any of these processes, as well as reductions in growth performance. As such, most animal diets are supplemented with inorganic and/or organic forms of trace minerals. Inorganic trace minerals (ITM) such as sulfates and oxides form the bulk of trace mineral supplementation, but these forms of minerals are well known to be prone to dietary antagonisms. Feeding high-quality chelated trace minerals or other classes of organic trace minerals (OTM) can provide the animal with more bioavailable forms of the minerals. Interestingly, many, if not most, published experiments show little or no difference in the bioavailability of OTMs versus ITMs. In some cases, it appears that there truly is no difference. However, real differences in bioavailability can be masked if source comparisons are not made on the linear portion of the dose-response curve. When highly bioavailable chelated minerals are fed, they will better supply the biochemical systems of the cells of the animal, leading to a wide variety of benefits in both poultry and swine. Indeed, the use of certain chelated trace minerals has been shown to enhance mineral uptake, and improve the immune response, oxidative stress management, and tissue and bone development and strength. Furthermore, the higher bioavailability of these trace minerals allows the producer to achieve similar or improved performance, at reduced levels of trace mineral inclusion.

The effect of cathodic protection system by means of zinc sacrificial anode on pier in Korea

  • Jeong, Jin-A;Jin, Chung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1206-1211
    • /
    • 2014
  • This study has been conducted to confirm the effect of sacrificial anode cathodic protection system for 90 days to protect corrosion on pier that is located in Korea. The cathodically protected structure was a slab and a pile cap. Before the construction of cathodic protection system, the macrography was carried out. As a result of the macrography, many corrosion traces were confirmed in this structure. The trace was mainly focused on joint and zones that concrete cover was eliminated. To apply the cathodic protection system, many onsite techniques have been adopted. In addition, to confirm the inner state of steel in concrete properly, a corrosion monitoring sensor (DMS-100, Conclinic Co. Ltd) has been applied. Test factors were corrosion & cathodic protection potential, 4 hour depolarization potential, resistivity and current density. After 90 days from the installation of cathodic protection system, it could confirm that proper corrosion protection effect was obtained by considering the result of tests.

Fully Collusion-Resistant Trace-and-Revoke Scheme in Prime-Order Groups

  • Park, Jong-Hwan;Rhee, Hyun-Sook;Lee, Dong-Hoon
    • Journal of Communications and Networks
    • /
    • v.13 no.5
    • /
    • pp.428-441
    • /
    • 2011
  • A trace-and-revoke scheme is a type of broadcast encryption scheme for content protection on various platforms such as pay-per-view TV and DVD players. In 2006, Boneh and Waters (BW) presented a fully collusion-resistant trace-and-revoke scheme. However, a decisive drawback of their scheme is to require composite-order groups. In this paper, we present a new trace-and-revoke scheme that works in prime-order groups. Our scheme is fully collusion-resistant and achieves ciphertexts and private keys of size O($\sqrt{N}$) for N users. For the same level of security, our scheme is better than the BW scheme in all aspects of efficiency. Some superior features include 8.5 times faster encryption, 12 times faster decryption, and 3.4 times shorter ciphertexts. To achieve our goal, we introduce a novel technique where, by using asymmetric bilinear maps in prime-order groups, the cancellation effect same as in composite-order groups can be obtained.

Thermal Characteristics of Fire-Protection Foams Exposed to Radiant Heating (복사열에 노출된 소방용 폼 약제의 열적 특성 연구)

  • Kim, H.S.;Hwang, I.J.;Kim, Youn-J.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1570-1575
    • /
    • 2004
  • In order to evaluate the performance of fire-fighting agents used to protect structures from heat and fire damages, the thermal characteristics of fire-protection foams are experimentally investigated. The current research focuses on the destruction of a fire-fighting foam subjected to heat radiation. A simple repeatable test for fire-protection foams subjected to fire radiation is developed. This test involves foam generation equipment, a fire source for heat generation, repeatable test procedures, and data acquisition techniques. Results of the experimental procedure indicated that each thermocouple within the foam responded in a similar manner and gradually to a temperature of $15^{\circ}C{\sim}20^{\circ}C$. At this point, each trace generally rises to a temperature of approximately $90^{\circ}C$. The temperature gradient in the foam as time passes increases with increased foam expansion ratio. In addition, it is determined that the temperature gradient along the foam for depth decreases with increased foam expansion ratio.

  • PDF

Numerical Analysis of Unsteady Heat Transfer for the Location Selection of Anti-freeze for the Fire Protection Piping with Electrical Heat Trace (소방 배관 동파방지용 열선의 위치 선정을 위한 비정상 열전달 수치해석)

  • Choi, Myoung-Young;Lee, Dong-Wook;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.52-57
    • /
    • 2014
  • In this paper, the unsteady incompressible Navier-Stokes equations coupled with energy equation were solved to find out the optimal location of electrical heat trace for anti-freeze of water inside the pipe for fire protection. Since the conduction equation of pipe was coupled with the natural convection of water, the analysis of conjugate heat transfer was conducted. A commercial code (ANSYS-FLUENT) based on SIMPLE-type algorithm was used for investigating the unsteady flows and temperature distributions in water region. From the numerical experiments, the isotherms and the vector fields in water region were obtained. Furthermore, it was found that the lowest part of the pipe cross-section was an optimal position of electrical heat trace assuming the constant thermal expansion coefficient of water since the minimum temperature of the water with the position is higher than those with the other positions.

Graphite Furnace Atomic Absorption Spectrophotometric Determination of Trace Horseradish Peroxidase Using Nanosilver

  • Jiang, Zhi-Liang;Tang, Ya-Fang;Wei, Lin;Liang, Ai-Hui
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2732-2736
    • /
    • 2011
  • In pH 4.2 HAc-NaAc buffer solution, horseradish peroxidase (HRP) catalyzed $H_2O_2$ oxidation of nanosilver to form $Ag^+$. After centrifugation, $Ag^+$ in the supernatant can be measured by graphite furnace atomic absorption spectrophotometry (GFAAS) at the silver absorption wavelength of 328.1 nm. When HRP concentration increased, the $Ag^+$ concentration in the supernatant increased, and the absorption value enhanced. The HRP concentration in the range of 0.84-50 $ng{\cdot}mL^{-1}$ was linear to the enhanced absorption value (${\Delta}A$), with a regression equation of ${\Delta}A$=0.012C+0.11, correlation coefficient of 0.9988, and detection limit of 0.41 $ng{\cdot}mL^{-1}$ HRP. The proposed GFAAS method was used to detect HRP in waste water samples, with satisfactory results.

A Kinetics Study of Rn Daughter and Atmospheric Trace Gas Using Alpha Track Detection (알파비적검출방법에 의한 대기중 라돈딸핵종의 화학적 동특성연구)

  • Yoon, Suk-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.79-83
    • /
    • 1995
  • A number of investigators have reported formation of radiolytic ultrafine particles produced by the interaction of ionizing radiation with atmospheric trace gases. Previous studies have suggested that a very high localized concentration of the hydroxyl radical produced by the radiolysis of water can react with atmospheric trace gases such as $SO_2$ and produce lower vapor pressure compounds that can subsequently nucleate. To determine the trace gas and water vapor concentration dependence of the active, positively charged, first decayt product of radon (Po-218), a well-controlled radon chamber was used in this research. The mobility spectrum of the decay products in the range of $0.07-5.0cm^2/V\;sec$ from the radon chamber was measured using alpha track detector installed inside a specially-designed electrostatic spectrometer. Measurements were taken for different concentrations (0.5ppm to 5ppm) of $SO_2$ in Purified, Compressed air. A kinetics Study following the clustering of $SO_2$ around the $PoO_x^+$ ion in an excess of $SO_2$ for interpretation of the reaction processes was performed.

  • PDF

Cryptographic Traces for the Protection of Mobile Agent Execution (이동 에이전트 실행 보호를 위한 암호학적 추적 방안)

  • Shin, Weon;Rhee, Kyung-Hyune
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.11 no.3
    • /
    • pp.71-78
    • /
    • 2001
  • In this paper, we describe the vulnerabilities against mobile agent and analyze existing schemes to cope with them. Also we propose a new scheme which protects the executed information by mobile agent and simultaneously traces the executions of mobile agent. The proposed scheme provides non-repudiation between participations for the executions of mobile agent, forward integrity against modification and protection against code insertion or deletion attack.

INFORMATION SYSTEM ON INTEGRATED RADIATION SAFETY (ISIRS) AND ORPHAN SOURCES CONTROL IN KOREA

  • Lee, Dewhey
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.255-263
    • /
    • 2001
  • An Orphan Sources Control program controlled by a web based information system in Korea has been developed to satisfy the national demand on a total management of and integrated radiation safety. There are, currently, three approaches going on to control and manage the orphan sources in Korea. First, Korean regulatory authority has been conducting scrutinizing investigation on and thoroughly monitoring the possession of unlicensed radioactive sources from the late 1990s. Second, the regulatory authority will fully operate an information system on radiation safety to effectively trace and monitor all radioactive sources in the country by the mid 2001. Finally, the regulatory authority strongly advises steel mill companies to closely scrutinize and inspect the scrap metals when they attempt to reutilize metals to prevent from being contaminated by uncontrolled sources through the scrap monitoring systems.

  • PDF