• Title/Summary/Keyword: Protection function

Search Result 1,145, Processing Time 0.026 seconds

Management Direction about Comparison of Protection Forest on Korea and Japan (한국과 일본의 보안림 비교를 통한 관리 방향)

  • Park, Jae-Hyeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.4
    • /
    • pp.67-75
    • /
    • 2006
  • This study compared with the object of designation and the management practices for Protection Forests between Korea and Japan to establish the management and development directions of Korea's Protection Forest. 1. Water conservation forest from total areas of Protection Forests occupied 90.6 % in Korea and 68.4 % in Japan, respectively. The water conservation forest was the most important function among the Protection Forest's functions in both countries. 2. The 10 million ha of Protection Forest in Japan increased for last 100 years. The 100 thousand ha per year was designated as Protection Forest. In contrast, The 655,535 ha of Protection Forest in Korea decreased for last 42 years with decreasing of 15,000 ha per year. 3. In Japan, Protection Forest can be managed by forest silvicultural practices such as forest harvest, thinning, and pruning to recover and improve the Protection Forest's functions. 4. In case of Korea, it is necessary to a mid- or long-term counter plan to increase the area of Protection Forest by the government, and needs to the recovery and improvement of Protection Forest's functions.

A New Protection Strategy of Impressed Current Cathodic Protection for Ship

  • Oh, Jin-Seok;Kim, Jong-Do
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.592-596
    • /
    • 2004
  • Corrosion is never avoided in the use of materials with various environments. The underwater hull is normally protected against rusting by several coatings of anti-corrosive paint. The purpose of ICCP(Impressed Current Cathodic protection) system is to eliminate the rusting or corrosion, which occurs on metal immersed in seawater. The anode of ICCP system is controlled by an external DC source with converter. The function of anode is to conduct the protective current into seawater. The proposed algorithm includes the harmonic suppression control strategy and the optimum protection strategy and has tried to test the requirement current density for protection, the influence of voltage, the protection potential. This paper was studied the variation of potential and current density with environment factors, time and velocity, and the experimental results will be explained.

A Safety Assessment Methodology for a Digital Reactor Protection System

  • Lee Dong-Young;Choi Jong-Gyun;Lyou Joon
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.1
    • /
    • pp.105-112
    • /
    • 2006
  • The main function of a reactor protection system is to maintain the reactor core integrity and the reactor coolant system pressure boundary. Generally, the reactor protection system adopts the 2-out-of-m redundant architecture to assure a reliable operation. This paper describes the safety assessment of a digital reactor protection system using the fault tree analysis technique. The fault tree technique can be expressed in terms of combinations of the basic event failures such as the random hardware failures, common cause failures, operator errors, and the fault tolerance mechanisms implemented in the reactor protection system. In this paper, a prediction method of the hardware failure rate is suggested for a digital reactor protection system, and applied to the reactor protection system being developed in Korea to identify design weak points from a safety point of view.

Protection Level Evaluation of Distribution Systems Based on Dempster-Shafer Theory of Evidence (Dempster-Shafer 증거 이론을 이용한 배전계통 보호도 평가)

  • Kim, He-Chul;Lee, Seung-Jae;Kang, Sang-Hee;Ahn, Bok-Shin;Park, Jong-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.896-898
    • /
    • 1998
  • Recent development of the digital computer and communication technology has made the concept of the adaptive protection possible, which is to adapt the operating parameters of the protective devices to the system changes, so that the best protection function can be maintained all the time. In order to achieve the adaptive protection, it is necessary to have the way to determine whether the change of the settings is needed under the certain system change or how good the current protection level is. This paper proposed the protectability index, which is a way to evaluate the protection level of the system under arbitary conditions and the operating strategy of the adaptive protection utilizing this index. It is based on an hierachical evaluation model and the evidence combination rule of the Dempster-Shafer theory.

  • PDF

Energy Absorbing Capacity for New Rockfall Protection Fence (신개념 낙석방지울타리의 낙석 지지능력 평가)

  • 문영종;정형조;박기준;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.293-298
    • /
    • 2003
  • The rockfall protection fences are installed to reduce rockfall damage in roads side slopes. The energy absorbing capacity of widely used rockfall protection fences is about 50kJ, But in many cases, rockfall protection fences are easily damaged even by a low level of rockfall energy. The objective of this paper is to verify the energy absorbing capacity of rockfall protection fences and investigate the behavior of them by rockfall. The LS-DYNA3D, a finite elements analysis program for dynamic movement of three dimensional objects, is used to perform the numerical simulations. In the result it is shown that rockfall protection fences absorb half of standard absorbing energy or less than it. It is inadquate for the rockfall protection fences to perform the principal function. To improve the performance of the fences, new rockfall proctection fence is proposed and numerical simulation is performed.

  • PDF

Characteristics and Energy Absorbing Capacity for New Rockfall Protection Fence (신개념 낙석방지울타리의 특성 및 성능평가)

  • 문영종;정형조;박기준;이인원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.461-466
    • /
    • 2003
  • The rockfall protection fences are installed to reduce rockfall damage in roads side slopes. The energy absorbing capacity of widely used rockfall protection fences is about 50kJ. But in many cases, rockfall protection fences are easily damaged even by a low level of rockfall energy. The objective of this paper is to verify the energy absorbing capacity of rockfall protection fences and investigate the behavior of them by rockfall. The LS-DYNA3D, a finite elements analysis program for dynamic movement of three dimensional objects, is used to perform the numerical simulations In the result, it is shown that rockfall protection fences absorb half of standard absorbing energy or less than it. It is inadquate for the rockfall protection fences to perform the principal function. To improve the performance of the fences, new rockfall proctection fence is proposed and numerical simulation is performed.

  • PDF

A Study for Protecting the Virtual Memory of Applications (어플리케이션의 가상 메모리 보호를 위한 연구)

  • Kim, Dong-Ryul;Moon, Jong-sub
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.6
    • /
    • pp.335-341
    • /
    • 2016
  • As information technology advances rapidly, various smart devices are becoming an essential element in our lives. Smart devices are providing services to users through applications up on the operating system. Operating systems have a variety of rules, such as scheduling applications and controlling hardwares. Among those rules, it is significant to protect private information in the information-oriented society. Therefore, isolation task, that makes certain memory space separated for each application, should highly be guaranteed. However, modern operating system offers the function to access the memory space from other applications for the sake of debugging. If this ability is misused, private information can be leaked or modified. Even though the access authority to memory is strictly managed, there exist cases found exploited. In this paper, we analyze the problems of the function provided in the Android environment that is the most popular and opened operating system. Also, we discuss how to avoid such kind of problems and verify with experiments.

Mathematical Verification of A Nuclear Power Plant Protection System Function With Combined CPN and PVS

  • Koo, Seo-Ryung;Son, Han-Seong;Seong, Poong-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.315-320
    • /
    • 1998
  • In this work, an automatic software verification method for Nuclear Power Plant (NPP) protection system is developed. This method utilizes Colored Petri net (CPN) for modeling and Prototype Verification system (PVS) for mathematical verification. In order to help flow-through from modeling by CPN to mathematical proof by PVS, a translator has been developed in this work. The combined method has been applied to a protection system function of Wolsong NPP SDS2(Steam Generator Low Level Trip)and found to be promising for further research and applications.

  • PDF

Dependability Analysis of Fault Detection Function and Reliability of Reactor Protection System (원자로보호계통의 고장검출기능과 신뢰도의 상관관계 분석)

  • Kim, Ji-Young;Park, Hong-Lae;Lyou, Joon;Lee, Dong-Young;Choi, Jong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.29-32
    • /
    • 2004
  • Reliability is an important issue on the digital reactor protection system. This paper presents a Quantitative reliability evaluation method to find out an improvement effect of availability for the digital control module with a fault detection function. It is a reliability evaluation model which considers only the electronics parts ocurring a spurious reactor trip by the FMEA(Failure Mode Effect Analysis). Applying the previous and present methods to the reactor protection system, the availability factors are evaluated and compared.

  • PDF

Emergency Brushless Synchronous Generator Having Rotating Exciter Status Monitoring and Protection Functions

  • Oh, Yongseung;Oh, Wonseok;Cho, Kyumin
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.2
    • /
    • pp.1-13
    • /
    • 2020
  • This paper presents an emergency brushless synchronous generator having rotating exciter status monitoring and protection functions. For monitoring the rotating exciter status, a wireless rotor status detector and a digital AVR(Automatic Voltage Regulator), which has a wireless communication capability, are proposed. The proposed rotor status detector detects temperatures of exciter armature and main field windings and input voltage and current of the main field. Therefore, it is possible to protect the generator from the over-temperature of windings and detect the exciter bridge diode fault. Furthermore, the proposed digital AVR has rotor status monitoring and protection function, and remote generator tuning, wireless group parallel operation function. So the operator can efficiently operate the generator using a smartphone from a remote area.