• Title/Summary/Keyword: Protection Zones

Search Result 118, Processing Time 0.022 seconds

Analysis of the Protective Distance of Low-Voltage Surge Protective Device(SPD) to Equipment (저압용 서지 보호 장치(SPD)의 보호 거리 해석)

  • Lee, Jung-Woo;Oh, Yong-Taek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.28-34
    • /
    • 2012
  • Installing surge protection devices for a low-voltage system is important to ensure the survival of electric or electronic devices and systems. If surge protection devices (SPD) are installed without consideration of the concept of lightning protection zones, the equipment to be protected might be damaged despite the correct energy coordination of SPDs. This damage is induced by the reflection phenomena on the cable connecting an external SPD and the load protected. These reflection phenomena depend on the characteristics of the output of the external SPD, the input of the loads, and the cables between the load and the external SPD. Therefore, the SPD has an effective protection distance under the condition of the specific load and the specific voltage protection level of SPD. In this paper, PSCAD/EMTDC software is used to simulate the residual voltage characteristics of SPD Entering the low-voltage device. And by applying a certain voltage level, the effective protection distances of SPD were analyzed according to the each load and length of connecting cable, and the effectiveness of SPD were verified.

A Study on DFS Beneficial for Reduction on Speed and Traffic Accidents (based on school zones in Buchon city) (DFS설치에 따른 속도 및 교통사고 감소효과에 관한 기초 연구 (부천시 School-zone을 대상으로))

  • Lee, Kye-June;Kim, Gyeong-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.31-38
    • /
    • 2008
  • Under the recent situation that there increase the efforts to facilitate DFS(driver feedback sign) in school zones and children's protection areas caused by severity of traffic impact on children, the current study aims at predictively evaluating how and to what extent the reduced car speed is influential to the reduction of traffic accidents in elementary schools located in Buchon city by analyzing the velocity variation before and after DFS installation including its reduction ratio in traffic accidents as well as related literature survey. It, furthermore, aims at identifying applicable effectiveness in DFS operation for elementary schoolers in Buchon based on the data collected.

A study on the performance of the sacrificial anode used for cathodic protection of a marine bridge after 8 years (해상 교량에 설치된 희생양극식 전기방식의 8년 이후의 성능에 관한 연구)

  • Jeong, Jin-A;Ha, Ji-Myung;Lee, Du-Young;Lee, Sang-Deuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.510-515
    • /
    • 2016
  • Recently, corrosion occurred on the piles of a marine bridge located on the NamHae expressway in Korea. A sacrificial anode cathodic protection system was installed to prevent corrosion damage in the marine bridge. In the case of the marine bridge in this study, the sacrificial anode cathodic protection system was applied at the tidal and splash zones of the piles because the upper part of the structure was not corroded, and because corrosion occurs at the tidal and splash zones due to sea tides. To verify the performance of the sacrificial anode cathodic protection system 8 years later, cathodic protection (CP) current, CP potential, and degree of depolarization were measured. The experimental results on the performance of the sacrificial anode cathodic protection system from a total of 60 piles were classified into 4 categories: good CP effect results (13 piles), partial CP effect results (27 piles), temporarily erroneous results (5 piles), and need for maintenance because of delamination (15 piles). It was determined that additional repairs are required, such as the application of bulk anodes and jacket casings, for piles where the CP effect is poor.

Partitioning Interwell Tracer Test for NAPL Source Characterization: A General Overview

  • Lee, Tony R.;A. Lynn Wood;Jeong, Seung-Woo
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.159-162
    • /
    • 2002
  • Innovative and nondestructive characterization techniques have been developed to locate and quantify nonaqueous phase liquids (NAPLs) in the vadose and saturated zones in the subsurface environment. One such technique is the partitioning interwell tracer test (PITT). The PITT is a simultaneous displacement of partitioning and non-partitioning tracers through a subsurface formation. Partitioning tracers will partition into the NAPL during their transport through NAPL-contaminated formations. Mean travel times of partitioning and non-partitioning tracers are used to estimate the quantity of NAPL encountered by the displaced tracer pulse. Travel times are directly proportional to the partitioning coefficient and the volume of NAPL contacted in the subsurface environment. This paper discusses the conceptual background, design and implementation of PITTs. (This document has not been subjected to Agency review and therefore does not necessarily reflect the views of the Agency, and no official endorsement should be inferred.)

  • PDF

Guaranteed GNSS-based Road Charging Applications through User-Level Integrity

  • Mark, Audrey;Schortmann, Joaquin Cosmen;Olague, Miguel Angel Martinez;Merino, Miguel Romay
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.77-82
    • /
    • 2006
  • Integrity plays a fundamental role in the feasibility of 'liability critical' applications. Road charging, e.g. road tolling in urban zones or on highways, represents a series of liability critical applications where a guarantee in integrity could be a true enabler: being the mechanism that prevents the incorrect charging of users and enabling the advancement of these applications using GNSS such as Galileo and EGNOS that provide integrity mechanisms. However, the integrity of the end user position is not guaranteed by the EGNOS and Galileo integrity services alone as provided. Algorithms have been developed to supply a guarantee on the performance attainable at the user level through the provision of a horizontal protection level that responds to local user conditions such as multipath or interference. In addition, an application has been developed that implements road charging mechanisms based on the availability of user-level integrity. Results obtained show that the user-level integrity algorithms provided the required level of integrity guarantee and granularity of the horizontal protection levels necessary for executing urban and rural (highway) road charging. In addition, the road charging application developed shows that the current application domain requirements can be met through the provision of guaranteed integrity and that further reductions in the horizontal protection levels along with increased signal availability will enable future road charging modalities.

  • PDF

Electrical Machines and Drives for Potentially Explosive Atmospheres

  • Grantham, Colin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.128-134
    • /
    • 2012
  • This paper gives an overview of the requirements for electrical equipment in potentially explosive atmospheres and describes how these are applied to electrical machines and drives in hazardous areas. The method by which equipment can be shown to be safe in a whole range of gases, by testing in a single test gas, is covered. It is shown how the more recently introduced methods of protection for hazardous areas, increased safety and nonsparking, are ideally suited to AC machines and drives. A novel method of measuring the fullload temperature rise of electrical machines for hazardous, and other areas, without the need to connect a mechanical load to the machine's drive shaft is explained.

Reformation of Environmental Regulation through introduction of the Zero Liquid Discharge System (무방류시스템 도입에 따른 환경규제효율화 방안)

  • Choi, Ji-Yong
    • Journal of Environmental Policy
    • /
    • v.2 no.1
    • /
    • pp.31-49
    • /
    • 2003
  • It is difficult to examine the causal relation of pollution damages because the time gap between pollution cause and effect is large and new pollutants are continuously being produced. Their many environmental effects are not promptly studied. As both the study of causal relation about pollution and the pollutant treatment are becoming highly advanced by the development of science and environmental technology, both the economy and balance on environmental regulation may be discussed. It is reasonable to decide environmental policy in consideration of close relation between both the generation and resolution of environmental problems and of technological developments because environmental problems are related to complicated social problems and scientific technologies. First item in policy decision about environmental control and management is preferentially to consider the way of prevention. It is necessary to prevent pollution by regulating the installment of environmental pollution facility into the environmentally sensitive areas, like water supply source and to regulate land utilization as a method to achieve pollution prevention. Second is a consideration of environmental technology development. This is a solution which can accomplish the development of environmental technology and the reinforcement of economic competition. Third is the coexistence of environment and economy. It is necessary to consider economy in connection with environmental problems and environment in economic problem. Then, we can enjoy a healthy life as well as economic affluence. Fourth is the enlargement of environmental management means. Environmental management means must be diversified because environmental cause and effect are varied. For Improving the land use regulation system, it is necessary to consider both land use regulation status and pollutant toxicity with the development of environmental technology. Land use must be approached by classifying land to 3 levels; water source protection zone and water front zone, special zone 1 and 2, rancus and other zones. Land regulation policy to prevent any accident in water source protection zone, waterfront zone, and special zone must be continuously upgraded. However, economical consideration in other zones is required by the development of environmental technology.

  • PDF

The Lightning Effects on Aircraft and Certification (항공기에 대한 낙뢰의 영향과 감항성 인증)

  • Han,Sang-Ho;Lee,Jong-Hui
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.9
    • /
    • pp.110-120
    • /
    • 2003
  • As the wooden aircraft in the early times has no way to let lightning flow when lighting flash attaches during flight, the aircraft got damage, or caught fire. Though all metal airplane was developed with an advent of aluminum, a lightning accident still occurred including a fire of a fuel tanks. Eventually, NACA declared problems in 1938, and an artificial lightning test began. III succession, FAA established Airworthiness Requirements for certification. The FAA committed test measures study for the protection of an airplane from lightning to SAE. SAE presented the test current and voltage waveforms that simulating natural lightning, and it is utilized on lightning protection certification of an airplane by public. A lightning effects of an airplane through an analysis of lightning mechanism was made in this technical note. Especially, lightning direct effects on aircraft are analyzed and lightning strike zones are described.

A Study on the Introduction of Zoning in Biosphere Reserves: Focusing on the Laws Related Protected Areas

  • Lee, Young-Jin
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.1
    • /
    • pp.95-105
    • /
    • 2021
  • Background and objective: A biosphere reserve is a complex concept that combines the preservation of biodiversity and the sustainable development with the region, outstanding ecosystems with worth conserving in worldwide. The purpose of this study is to suggest the way of zoning that can perform the functions of conservation, development, and logistics support of biosphere reserves. Methods: To meet the purpose of this study, the designation criteria, restrictions, and permissions of the protected area specified in the law for domestic protected areas were reviewed to classify the functions of a biosphere reserve. Results: Through this classification, 10 domestic protected areas with high ecological protection value, such as the natural beauty of the ecosystem, biodiversity, and habitats for wild animals and plants were derived as the core areas of the biosphere reserves. Also, a total of 21 protected zones that can function as a buffer to protect the core of the natural ecosystem from indiscriminate development such as resource protection, recovery, pollution prevention, and improvement were derived as appropriate sites for a buffer. In the review process, issues such as different behavioral restrictions and ranges of permission due to the application of different laws were identified, if two or more protected areas exist within one of the protected areas, there is a protected area that does not meet the criteria for designating use zone, or where behavior restrictions do not meet the zoning criteria of biosphere reserve, under the laws of domestic protected areas. Conclusion: Although this study was not able to carefully review most of the laws on domestic protected areas that are linked to other laws, it was able to categorize appropriate domestic protected areas that can act as the core and buffer zones of biosphere reserves.

Impact of Fixed Series Capacitors and SSSC on the LOE Protection of Synchronous Generator

  • Ghorbani, Amir;Lima, Hossein Mehryari;Azadru, Allahverdi;Mozafari, Babak
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1453-1459
    • /
    • 2015
  • Loss of excitation (LOE) relay is prevalently used to protect synchronous generator. The widely used method for synchronous generator LOE protection is a negative offset mho relay with two zones. The basis of this relay is identical to mho impedance relay. In other words, this relay calculates impedance by measuring voltage and current at the generator terminal. On the other hand, the presence of series compensation, changes measured voltage and current signals during loss of excitation. This paper reveals that the presence of series compensators such as fixed series capacitors (FSCs) and static synchronous series compensator (SSSC) causes a significant delay on the performance of generator LOE relay. It is also shown that the presence of SSSC causes the LOE relay to be under-reached. Different operating modes of the power system, the SSSC and also different percentages of series capacitive compensations have been considered in the modeling. All the detailed simulations are carried out in the MATLAB/Simulink environment using the SimPowerSystems toolbox.