• Title/Summary/Keyword: Protection Zone

Search Result 373, Processing Time 0.028 seconds

Quench analysis and protection circuit design of a superconducting magnet system for RISP 28GHz ECR ion source

  • Song, S.;Ko, T.K.;Choi, S.;Ahn, M.C.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.2
    • /
    • pp.37-41
    • /
    • 2016
  • This paper presents the developed quench analysis code and protection circuit design for a superconducting magnet system of 28GHz electron cyclotron resonance (ECR) ion source. The superconducting magnet is composed of a hexapole magnet and four solenoid magnets located outside of the hexapole one. All magnets are wound with NbTi composite wire and impregnated by epoxy. By using the developed characteristic analysis code, the normal zone resistance, decaying current and temperature rising can be estimated during quench. Also, the stored magnetic energy is successfully consumed from the series resistor of the designed protection circuit. The analytical results are compared with the experimental results to verify the developed quench analysis code and protection circuit.

A Study on the Planning of Smoking Space in Apartment for the Rights of Smokers and Nonsmokers - Using the shaft space of the unit plan - (흡연자와 비흡연자의 권리보호를 위한 공동주택 내의 흡연 공간 계획에 관한 연구 - 동 평면의 샤프트 공간을 활용하여 -)

  • Kim, Tae-Hun;Bae, Si-Hwa;Suh, Sang-Wook;Choi, Hyun-Chul
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.33 no.12
    • /
    • pp.105-112
    • /
    • 2017
  • Through various media, damage of both smoking and second-hand smoking has been recognized, and brought global scale of interest in antismoking. In Korea, government has tightened regulations of smoking in non-smoking zone since December, 1980, and after National Health Promotion Act in 1995, non-smoking zone has been gradually expanded. On the other hand, there were law suits to find those regulation towards smokers are either unconstitutional or not for 4 times. In this current state, people need smoking area to prevent second-hand smoking and to consider smokers in multi-unit dwelling. Main purpose of this research is to plan smoking spaces based on various typology of multi-dwelling plan for protection of both smokers and non-smokers' right. The research group collected and analyzed the smoking behaviors in various multi-unit dwelling types such as flat type, tower type, hybrid type and others. Based on those data, the group found three phenomena. First, there are internal regulations in multi-unit dwelling to make non-smoking zone based on National Health Promotion Act and resident representative meeting decision. Second, main smoking activities are occurring at major traffic line and entrances. Third, smoking inside of multi-unit dwelling complex causes second-hand smoking to residents live in $1^{st}$ floor and when they enter. Therefore, one can achieve both smokers' and non-smokers' protection of right by creating a designated smoking space near main entrances of multi-unit dwelling complex to consider smokers' and prevents second-hand smoking by using shaft space, which is in core space, to ventilate tobacco smoke through roof.

Efficiency of Riparian Buffer Zone on Removing Sediment Yield Using SWAT Model (SWAT 모형을 이용한 수변완충지대 설정에 따른 토사유출량 저감 효과분석)

  • Choi, Dae-Gyu;Park, Moo-Jong;Kim, Jae-Chul;Kim, Sang-Dan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.111-118
    • /
    • 2008
  • Riparian buffer zone prevents sediment entry into drainage channels or as a protection from runoff and wind erosion. However, Studies about its removing effect according to Riparian buffer zone are shorted now. In this study, using the SWAT model, Byongseong watershed is built on the Arcview GIS. Using the function of the filter strip in SWAT model, it is also examined about the variation of sediment yield. As a simulation result, the case of constructing riparian buffer zones at subbasins near the outlet shows generally high efficiency on removing sediment yield. In addition, according to the scenario analysis of changing riparian buffer zone width, it is thought that 5-10m riparian buffer zone width is the highest efficiency on removing sediment yields generated from Byeongseong watershed.

Prioritization of Potential Technology for Establishing a Safe Work Zone Environment (안전한 도로 공사구간 환경 구축에 필요한 기술의 우선순위 선정)

  • Kim, Jin Guk;Yang, Choong Heon;Yun, Duk Geun
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.117-126
    • /
    • 2015
  • PURPOSES : This study prioritizes potential technology for establishing a safe work zone environment on roadways. We consider almost all conceivable technologies that enable mitigation of unexpected accidents for both road workers and drivers. METHODS : This study suggests a methodology to set the priority of potential technology for establishing a safe work zone environment by using the analytical hierarchy process (AHP). For this purpose, the AHP structure was first developed. Thereafter, a web-based survey was conducted to collect experts' opinions. Based on the survey results, weights associated with the relevant criteria of the developed structure were estimated. With the consistency index (CI) and consistency ratio (CR), we verified the estimated weights. In addition, a sensitivity analysis was performed to confirm whether the estimated weights were reliable. We finally proposed the priority for potential technology for establishing a safe work zone environment on roadways. RESULTS : In the first level, safety technology has the highest priority, and real-time information delivery for work zone, hazard warning for drivers, and temporal automated operation for traffic facilities were selected in the second level of hierarchy. CONCLUSIONS : The results imply that establishing the priority will be useful to establish a future road map for improving the work environment for road workers and drivers by employing appropriate protection facilities and developing safety systems.

GPS based Green Zone Access Monitoring System (GPS 기반 그린존 접근감시 시스템)

  • Jang, Jae-Myung;Lee, Hyoung-Seon;Jeong, Do-Hyeong;Song, Hyun-Ok;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.612-613
    • /
    • 2016
  • Today, a variety of systems have been developed to protect women and children. However, crime rates are still rising in the Green Zone. So we need the system to protect it. In this paper, we propose a system that sends messages in real time to the Green Zone administrator when a registered offender access to the Green Zone area. The existing system is a passive data transmission through monitoring. But the proposed system when access to the Green Zone set, detects a GPS-based. Accordingly, It is expected to be able protection through to monitor in real time and manage for women and children from criminals.

  • PDF

A Study on the Post-Weld Heat Treatment Effect to Mechanical Properties and Hydrogen Embrittlement for Heating Affected Zone of a RE 36 Steel

  • Moon, Kyung-Man;Lee, Myung-Hoon;Kim, Ki-Joon;Kim, Jin-Gyeong;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.2 no.6
    • /
    • pp.283-288
    • /
    • 2003
  • The cathodic protection method is being widely used in marine structural steel, however a high tensile steel like RE 36 steel for marine structural steel is easy to get hydrogen embrittlement due to over protection during cathodic protection as well as preferential corrosion of HAZ(Heating Affected Zone) part. In this paper, corrosion resistance and mechanical properties such as elongation and hydrogen embrittlement were investigated with not only in terms of electrochemical view but also SSRT(Slow Strain Rate Test) method with applied constant cathodic potential, analysis of SEM fractography in case of both As-welded and PWHT(Post-Weld Heat Treatment) of $550^{\circ}C$. The best effect for corrosion resistance was apparently indicated at PWHT of $550^{\circ}C$ and elongation was increased with PWHT of $550^{\circ}C$ than that of As-welded condition. On the other hand. Elongation was decreased with applied potential shifting to low potential direction which may be caused by hydrogen embrittlement, however the susceptibility of hydrogen embrittlement was decreased with PWHT of $550^{\circ}C$ than that of As-welded condition and Q.C(quasi cleavage) fracture mode was also observed significantly according to increasing of susceptibility of hydrogen embrittlement. Eventually it is suggested that an optimum cathodic protection potential range not causing hydrogen embrittlernent is from -770 mV(SCE) to -850 mV(SCE) in As-welded condition while is from -770 mV(SCE) to -875 mV(SCE) in PWHT of $550^{\circ}C$.

Experiments on the Submarine Cable Protection Methods Considering the Connection Type (체결형상을 고려한 해저케이블 보호공법에 관한 실험)

  • Yoon, Jae Seon;Ha, Taemin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.329-329
    • /
    • 2017
  • In this study attempted to evaluate the stability of the protection methods by examining hydraulic characteristics of the area around the point in which marine cable protector is installed such as surf zone occurrence point of shore-end submarine cables suitable for coastal marine environmental conditions, flow rate t the tope of the protector and maximum wave height, and to provide basic data for the selection of the optimal protection method. In performing hydraulic model experiments, the topography of submarine cable installation location was reproduced in 2-D sectional channel, and models appropriate for experimental scale and similitude law were produced and installed for each condition of submarine cables and protectors. Since the topography and submarine cable protectors were reproduced and installed in 2-D sectional channel, the exact reproduction of surf and transformation in shallow water zone was possible, and thus the physical properties could be clearly analyzed. For stability review, an experiment to examine the stability was conducted using a wave maker with 50-year frequency design waves as target, and wave height and cycles were applied based on the approximate lowest low water level(Approx. L.L.W), which is the most dangerous in submarine cable protection methods. As for experimental time, typhoon passing time in summer (about 3 hours) was applied, and wave patterns and deviation ratio of the submarine cable protector were investigated after making irregular waves corresponding to design waves. In addition, current meter and wave height meter were installed at the installation location of the submarine cable protector, and the flow rates and wave height at the top of the protector were measured and analyzed to review hydraulic properties.

  • PDF

Measures to Implements the Landscape Conservation and Management in the Seowon Hamyang Namgye inscribed on the World Heritage List (세계유산 등재대상 함양 남계서원의 경관보존관리방안)

  • Choi, Jong-Hee;Moon, Young-Suk;Kim, Dong-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.2
    • /
    • pp.128-135
    • /
    • 2013
  • The purpose of this study is a suggestion that it is a way for conservation and management the Namgye Seowon's heritage value based on its landscape visibility and land use; Namgye Seowon is a world heritage registration object. To do this, We had done a field investigation and a literature examination. The investigations are as following; first, setting protection zone through a comprehensive approach beyond uniform cultural properties protection zone is to note current intellectual situations as well as the place related to the locational characteristics and figures of Namgye Seowon. It's to set fore seeable section of landscape by analyzing visibility focusing through on Pungyeongnu, and it consider with protection zone and the present condition of land use. Especially, external view of landscape in Namgye Seowon is visualized with Baekam-san in the distance view of it and Cheonhwang-bong in Daebong-san and nearby large soundproof walls and the towers acts as an impediment factor to the view of landscape. In addition, to recover the original view of landscape of the Namgye Seowon, reckless plans focusing the authenticity of the world heritage should be limited and in case of the vegetation landscape, restoration and maintenance will be made through historical research literature. Through this study, researches on Namgye Seowon and several seowons will be done actively and its aims are to become the framework of landscape conservation and management measures to meet world heritage criteria.

Digital Ratio Differential Relaying for Main Protection of Large Generator (대형 발전기 주보호를 위한 디지털 비율차동 계전기법)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • An AC generator is an important component in producing an electric power and so it requires highly reliable protection relays to minimize the possibility of demage occurring under fault conditions. It is a need for research of digital generator protection system(DGPS) for the next-generation ECMS and an efficient operation of protection control system in power station. However, most of protection and control system used in power plants have been still imported as turn-key and operated in domestic. This may cause the lack of the correct understanding on the protection systems and methods, and thus have difficulties in optimal operation. In this paper, presented ratio differential relaying(RDR) is main protective element in generator protection IED. The fault detection technique, operation zone and setting value of the RDR were studied and, compared with two of the fault detection algorithm. For evaluation performance of the RDR, the data obtained from ATPDraw5.7p4 modeling was used. The proposed methods are shown to be able to rapidly identify internal fault and did not operate a miss-operation for all the external fault.

The Estimated Evacuation Time for the Emergency Planning Zone of the Kori Nuclear Site, with a Focus on the Precautionary Action Zone

  • Lee, Janghee;Jeong, Jae Jun;Shin, Wonki;Song, Eunyoung;Cho, Cheolwoo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.196-205
    • /
    • 2016
  • Background: The emergency planning zone (EPZ) of the city of Busan is divided into the precautionary actions zone (PAZ) and the urgent protective action planning zone; which have a 5-km radius and a 20-km to 21-km radius from the nuclear power plant site, respectively. In this study, we assumed that a severe accident occurred at Shin-Kori nuclear unit 3 and evaluated the dispersion speed of radiological material at each distance at various wind speeds, and estimated the effective dose equivalent and the evacuation time of PAZ residents with the goal of supporting off-site emergency action planning for the nuclear site. Materials and Methods: The total effective dose equivalent, which shows the effect of released radioactive materials on the residents, was evaluated using the RASCAL 4.2 program. In addition, a survey of 1,036 residents was performed using a standardized questionnaire, and the resident evacuation time according to road and distance was analyzed using the VISSIM 6.0 program. Results and Discussion: According to the results obtained using the VISSIM and RASCAL programs, it would take approximately 80 to 252.2 minutes for permanent residents to move out of the PAZ boundary, 40 to 197.2 minutes for students, 60 to 232.2 minutes for the infirm, such as elderly people and those in a nursing home or hospital, and 30 to 182.2 minutes for those temporarily within the area. Consequently, in the event of any delay in the evacuation, it is estimated that the residents would be exposed to up to $10mSv{\cdot}h^{-1}$ of radiation at the Exclusion Area Boundaries (EAB) boundary and $4-6mSv{\cdot}h^{-1}$ at the PAZ boundary. Conclusion: It was shown that the evacuation time for the residents is adequate in light of the time lapse from the initial moment of a severe accident to the radiation release. However, in order to minimize the evacuation time, it is necessary to maintain a system of close collaboration to avoid traffic congestion and spontaneous evacuation attempts.