• 제목/요약/키워드: Protection Standards

Search Result 679, Processing Time 0.026 seconds

Re-evaluation of Korean Effluent Concentration Limits and Comparative Analysis

  • Hwang, Won Tae;Lee, Joeun;Kwon, Dahye;Kim, Eun Han;Han, Moon Hee
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.124-129
    • /
    • 2018
  • Background: Effluent Concentration Limits (ECLs) were re-evaluated via direct calculation using dose coefficients based on radiation protection quantity introduced in Korea and the intrinsic breathing rates of Korean residents. Materials and Methods: The re-evaluated ECLs were compared with the domestic standards given in the Notice of the Nuclear Safety and Security Commission (NSSC), as well as with ECLs specified in the Code of Federal Regulations (CFR). Results and Discussion: The relative ratios of the re-evaluated ECLs to the currently applied domestic standards differed depending on the radionuclide type, but it was clearly shown that, for tritium ($^3H$) and radiocarbon ($^{14}C$), which significantly affect radiological dose to the public during the normal operation of nuclear power plants, the re-evaluated ECLs were higher than the domestic standards. This implies that Korean standards are relatively conservative. Conclusion: The re-evaluated results for each age group showed that $^{131}I$ (radioiodine), one of the significant radionuclides, had the lowest values, but nonetheless, the domestic standards for radioiodine were lower than the ECLs given in the CFR and the re-evaluated ECLs via a method given in the CFR.

Development of a Techniques of the Performance Test for a Radiation Protection Devices and it's International Standards (방사선 방호용 계측기 성능평가 기술 개발 및 국제 표준)

  • Choi, Kil-Oung;Won, Sung-Ho;Kim, Jung-Ho;Hah, Suck-Ho;Yi, Chul-Young;Kim, Hyun-Moon;Lee, Min-Kee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • International Standardization in all technical area is gaining its momentum as its impact and implication over global trade is directly linked. The worldwide competition to secure a dominant position in the standardization process is ever growing over the years. In 2005, the International Technical Committee on Nuclear Instrumentation, which is a subunit of International Electro-technical Commission (IEC), was held in Korea under the auspices of MOST (Ministry of Science and Technology). Korea has adopted its Rule and Regulation as the National Standard. As a part of a link to National Mid-and Long-term Atomic Energy R&D Program of MOST, the technical development of a performance test for the radiation monitors was carried out under mechanical environment and electromagnetic immunity conditions. The characteristics of the radiation fields were also evaluated under the conditions and introduced to a techniques of performance test for the radiation protection instrumentation adopted IEC61526 standards and it's results was analyzed. We would like to share the experience gained in these efforts, failure as well as success, and to discuss the problems encountered and serious consideration to be taken into account in the future endeavor.

Radioactive Neutron Source Calibration at the Korea Standards Research Institute (K-SRI 에서의 방사성 중성자 선원교정)

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.67-73
    • /
    • 1985
  • The manganous sulfate bath method for neutron source calibrations at the K-SRI is described together with the measurement of neutron emission rate of a source and the corrections applied for capture by competing nuclei of neutrons, and thermal neutron leakage, neutron absorption in the source itself. The commercially available neutron sources (Am-Be, $^{252}Cf$) for the calibration checks of neutron radiation instruments in the MeV range are considered in this paper.

  • PDF

Protection Switching Methods for Point-to-Multipoint Connections in Packet Transport Networks

  • Kim, Dae-Ub;Ryoo, Jeong-dong;Lee, Jong Hyun;Kim, Byung Chul;Lee, Jae Yong
    • ETRI Journal
    • /
    • v.38 no.1
    • /
    • pp.18-29
    • /
    • 2016
  • In this paper, we discuss the issues of providing protection for point-to-multipoint connections in both Ethernet and MPLS-TP-based packet transport networks. We introduce two types of per-leaf protection-linear and ring. Neither of the two types requires that modifications to existing standards be made. Their performances can be improved by a collective signal fail mechanism proposed in this paper. In addition, two schemes - tree protection and hybrid protection - are newly proposed to reduce the service recovery time when a single failure leads to multiple signal fail events, which in turn places a significant amount of processing burden upon a root node. The behavior of the tree protection protocol is designed with minimal modifications to existing standards. The hybrid protection scheme is devised to maximize the benefits of per-leaf protection and tree protection. To observe how well each scheme achieves an efficient traffic recovery, we evaluate their performances using a test bed as well as computer simulation based on the formulae found in this paper.

Radiological Dose Assessment Due to the Operation of Nuclear Facilities at KAERI Nuclear Site

  • Han, M.H.;Kim, E.H.;Hwang, W.T;Yeom, J.M.;Han, J.T.;Lee, Y.B.;Han, W.J.
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.247-254
    • /
    • 2003
  • To prevent the potential health detriment to the public from radioactive effluents, radiological dose assessments due to the operation of nuclear facilities located at Korea Atomic Energy Research Institute (KAERI) site has been performed semiannually in compliance with the Minister of Science and Technology (MOST)'s Notice in Korea. Radiological dose assessment based on the new recommendation of the International Committee on Radiation Protection (ICRP-60) has been conducted since 1998. In this manuscript, a serial activities at KAERI site to meet the regulatory standards for routine releases of radioactive effluents are introduced and discussed including technical approaches. It is clear that each nuclear facility has been operated in compliance with regulatory standards. Furthermore, it is identified that the radiation induced health effects for residents around the site are neglectable.

An Analysis of Performance Testing for Metallic Connection Components of Lightning Protection System (피뢰시스템 구성부품 중 금속접속재의 성능시험 및 결과분석)

  • Lee, Ju-Cheol;Lee, An-Ki;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.69-74
    • /
    • 2014
  • Recently, IEC published new standards about the requirements and tests for lightning protection system(LPS) components. If components are used for LPS, they should comply with the IEC standards. This paper, we collected six specimens for the metallic connection components using in domestic, and it tested for withstand lightning current which according to the IEC 62561-1. As a result, only one specimen meet this performance requirement. The specimen is the metallic connection component with four bolts fixed. Therefor, when designing of LPS in domestic, the metallic connection components shall be taken into account for the selection of the withstand lightning current. In addition, we need to develop for LPS components product and the national standards.

Statistics on the Present Status of Installations of Non-conventional Lightning Rods (일반형이 아닌 피뢰침의 설치 실태에 대한 통계적 조사)

  • Lee, Bok-Hee;Lee, Seok-Yeon;Lee, Su-Bong;Baek, Young-Hwan;Lee, Kyu-Sun;Kim, Dong-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.347-350
    • /
    • 2006
  • The conception of early streamers is in sufficient and inadequate as a parameter for the determination of any advantage of early streamer emission(ESE) lightning rods versus ordinary lightning rods. Thus, standards for many other national and international lightning protection as well as KS C IEC 61024-1 do not take ESE lightning rods, charge dissipation systems or non-conventional lightning rods. Unfortunately, many non-conventional lightning rods such as ESE lightning rods and charge dissipation systems in Korea are increasingly used in lightning protection of structures including explosive manufacturing buildings, electric generating, transmission and distribution systems. This study attempts to make aware of no advantage of ESE rods and other non-conventional lightning protection systems and to investigate the present status of installations of ESE lightning rods.

  • PDF

General Requirements Pertaining to Radiation Protection in Diagnostic X-ray Equipment -KFDA DRS 1-1-3 : 2008 base on IEC 60601-1-3:2008- (진단용 엑스선 장치에 있어서 방사선 방어에 대한 일반 요구사항 -IEC 60601-1-3:2008에 근거한 KFDA DRS 1-1-3:2008-)

  • Kang, Hee-Doo;Dong, Kyung-Rae;Kweon, Dae-Cheol;Choi, Jun-Gu;Jeong, Jae-Ho;Jung, Jae-Eun;Ryu, Young-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.69-77
    • /
    • 2009
  • This study gives an account of the collateral standards in IEC 60601-1-3: 2008 specifying the general requirements for basic safety and essential performance of diagnostic X-ray equipment regarding radiation protection as it pertains to the production of X-rays. The collateral standards establish general requirements for safety regarding ionization radiation in diagnostic radiation systems and describe a verifiable evaluation method of suitable requirements regarding control over the lowest possible dose equivalent for patients, radiologic technologists, and others. The particular standards for each equipment can be determined by the general requirements in the collateral standard and the particular standard is followed in the risk management file. The guidelines for radiation safety of diagnostic radiation systems is written up in ISO 13485, ISO 14971, IEC 60601-1-3(2002)1st edition, medical electric equipment part 1-3, and the general requirements for safety-collateral standards: programmable electrical medical systems. Therefore the diagnostic radiation system protects citizens' health rights with the establishment and revisions of laws and standards for diagnostic radiation systems as a background for the general requirements of radiation safe guards applies, as an international trend, standards regarding the medical radiation safety management. The diagnostic radiation system will also assure competitive power through a conforming evaluation unifying the differing standards, technical specifications, and recognized processes.

  • PDF