• 제목/요약/키워드: Protection Reinforcement

검색결과 164건 처리시간 0.029초

해양환경에 폭로한 콘크리트의 내염특성에 대한 실험적 연구 (I) (An Experimental Study on the Salt Resistance Properties with Concrete Materials under Marine Exposure Environment (I))

  • 신도철;김영웅;김용철;김동철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.51-56
    • /
    • 2002
  • Protection against salt attack in seawater is obtained by using a dense, quality concrete with a low water-cement ratio, and a components appropriate for producing concrete having the needed salt resistance. The objective of this study is to evaluate the feature of corrosion with using the various concrete materials under marine exposure environment. According to the test results, slag powder and anti -corrosion inhibitor showed high chloride resistance effect. Also concre crack have an influence on corrosion of steel in spite of mixed design for salt resistance concrete. The requirement for low permeability is essential not only to delay the effect of salt attack, but also to afford adquate protection to reinforcement with admixtures.

  • PDF

염화물 침투 콘크리트의 균열 특성에 관한 철근부식에 관한 연구 (Rapid Corrosion Test on Reinforcing Steels in Chloride-Penetrating Concrete Structures with Various Crack Patterns)

  • 류금성;정영수;유환구;김국한;조창백
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.693-696
    • /
    • 1999
  • Reinforced concrete is, in general, known as high durability construction material under normal environments due to strong alkalinity of cement. It is , however, well known that moderate or minor cracks in reinforced concrete should be most serious causes to deteriorate the durability of RC structures. Furthermore, chloride contents penetrating through unexpected cracks in reinforced concrete bridges get to weaken corrosion resistance of reinforcement steel in concrete and than to accelerate the deterioration of concrete durability. The objective of this experimental research is 1) to evaluate the effect of various corrosion protection system for reinforced concrete specimens with moderate or minor cracks which are exposed to cyclic wet and dry seawater, and then 2) to develop effective corrosion protection system for reinforced concrete bridges under the exposure of various detrimental environments such as seawater, deicing and etc.

  • PDF

염해환경하 콘크리트의 철근방식공법 연구 (Research for Corrosion Protection System of Embedded steels for Reinforced Condrete Exposed to Chloride Environments.)

  • 문홍식;류금성;정영수;박희상
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.281-284
    • /
    • 1999
  • Bridge structure is known as one of important infrafacilities for comfortable human life. Recent long-span bridges, such as Kwang-Ahn Grand bridge, S대-Hae Grand Bridge, Young-Jong Grand Bridge, etc, have been designed and constructed near the seaside without in-depth consideration of concrete durability problems, It is in particular noted that corrosion of reinforcement steel in concrete is very important for the durability enhancement of concrete structures. The objective of this experimental study is to investigate the corrosion degree of reinforcing steels in concrete specimens which are exposed to cyclic wet and dry saltwaters, and then to develop pertinent corrosion protection system such as rational cover depth, corrosion inhibitors, cathodic system for reinforced concrete bridges exposed to marine environment.

  • PDF

콘크리트내 철근의 전기방식과 리모트 모니터링 시스템의 활용에 관한 연구 (Cathodic Protection Test and Feasibility Study on Remote Monitering System of Concrete Structure)

  • 권기주;서용표;이경진;이장화;민병렬;이문환
    • 콘크리트학회지
    • /
    • 제10권3호
    • /
    • pp.209-218
    • /
    • 1998
  • 본 연구에서는 콘크리트내 철근의 방식성을 검토하기 위하여 실제 구조물과 유사하도록 콘크리트 대형 패널 실험체를 제작하였으며, 실험체 제작시 콘크리트 내부에 염화물을 혼입하여 음극전기방식 공법을 도입한 실험체와 공법을 도입하지 않은 실험체의 염화물에 의한 철근방식효과를 비교 분석하였다. 실험에 사용된 음극전기방식은 비소모성 티타늄 양극망을 사용한 외부전원방식이며, 최근에 국내에서도 사용실적이 늘고 있는 리모트 모니터링 시스템을 적용하여 구조물의 유지관리상 연속성 있게 콘크리트내 철근의 방식정도를 확인할 수 있는지에 대해 검토하였다.

절토사면 유지관리 매뉴얼 작성을 위한 현장조사에 관한 연구 (A Study on Site investigation for Cut Slope Management Manual preparation)

  • 지영환;장범수;김용수;이종영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.825-830
    • /
    • 2005
  • Cut slope and facility of management investigation is the protection of humans and properties. it is very important the prevention of disaster facility and the damage of the slope protection facility. It is very difficult to forecast slope stability, disaster possibility and collapse. It will be able to minimize the damage which it prepare against slope facility and cut slope of deformable investigation and collapse and the disaster. therefore those deformable investigation is important. Investigations execute upheaval, crack, sliding for slope and cut slope reinforcement. Investigation executes forecast in place where the construction problem, the effect which the damage in road traffic or the contiguity facility.

  • PDF

염화물 침투 콘크리트의 균열 특성에 따른 철근 부식에 관한 연구 (Rapid Corrosion Test on Reinforcing Steels in Chlordie-Penetrating Structures with Various Crack Patterns)

  • 류금성;유환구;김국환;이상국;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.718-723
    • /
    • 2000
  • Reinforced concrete is in general, known as high durability construction material under normal environments due to strong alkalinity of cement. It is, however, well known that moderate or minor cracks in reinforced concrete should be most serious causes to deteriorate the durability of RC structures. Futhermore, chloride contents penetrating through unexpected cracks in reinforced concrete bridges get to weaken corrosion resistance of reinforcement steel in concrete and then to accelerate the deterioration of concrete durability. The objective of this experimental research is 1) to evaluate the effect of various corrosion protection systems for reinforced concrete specimens with moderate or minor cracks which are exposed to cyclic wet and dry seawater, and then 2) to develop effective corrosion protection systems for reinforced concrete bridges under the exposure of various detrimental environments such as seawater, deicing and etc.

  • PDF

철근부식도 측정 및 방식기법 제시 (Corrosion Protection System and Measurement for Reinforcing Steels in Concrete)

  • 문홍식;이상국;류금성;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.827-832
    • /
    • 2000
  • Bridge structure is known as one of important infrafacilities for comfortable human life. Recent long-span bridges, such as Kwang-Ahn Grand bridge, Seo-hae Grand Bridge, Young-Jong Grand Bridge, etc, have been designed and constructed near the seaside without in-depth consideration of concrete durability problem. It is in particular noted tat corrosion of reinforcement steel in concrete is very important for the durability enhancement of concrete structures. The objective of this experimental study is to investigate the corrosion behavior of reinforcing steels in concrete specimens which are exposed to cyclic wet and dry saltwaters, and then to develop pertinent corrosion protection system such as rational cover depth, corrosion inhibitors, cathodic system for reinforced bridges exposed to marine environment.

  • PDF

155mm 포탄 및 C-4 90kg 기폭에 의한 야전구축 방호자재 및 구조체용 신방호자재의 방호성능 평가 (Evaluation of Protective Performance of Protection Materials for Field and Structural Body by Ignition of 155mm Artillery Shell and C-4 Explosive)

  • 이인철;김홍섭;남정수;김석봉;홍원희;김규용
    • 한국군사과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.493-500
    • /
    • 2013
  • In this study, it was evaluated the protective performance of the protection material for filed of the army by impact of fragment from the explosion of 155mm artillery shell to propose the improvement items. And it was evaluated the protection materials for structural boby such as corrugated steel plate, concrete block, prevention paint of explosion, aluminum foam and concrete T-wall by impact of fragment of 155mm artillery shells and explosion-induced pressure of C-4 explosive. As a result, protective performance of the existing protective material was superior but reinforcement is necessary for secondary damage because sand is leaking. The protective performance of new protective materials was greater than existing protective materials. And it can be used for protective materials.

Efficiency of insulation layers in fire protection of FRP-confined RC columns-numerical study

  • El-Mahdya, Osama O.;Hamdy, Gehan A.;Hisham, Mohammed
    • Structural Engineering and Mechanics
    • /
    • 제77권5호
    • /
    • pp.673-689
    • /
    • 2021
  • This paper addresses the efficiency of thermal insulation layers applied to protect structural elements strengthened by fiber-reinforced polymers (FRP) in the case of fire event. The paper presents numerical modeling and nonlinear analysis of reinforced concrete (RC) columns externally strengthened by FRP and protected by thermal insulation layers when subjected to elevated temperature specified by standard fire tests, in order to predict their residual capacity and fire endurance. The adopted numerical approach uses commercial software includes heat transfer, variation of thermal and mechanical properties of concrete, steel reinforcement, FRP and insulation material with elevated temperature. The numerical results show good agreement with published results of full-scale fire tests. A parametric study was conducted to investigate the influence of several variables on the structural response and residual capacity of insulated FRP-confined columns loaded by service loads when exposed to fire. The residual capacity of FRP-confined RC column was affected by concrete grade and insulation material and was shown to improve substantially by increasing the concrete cover and insulation layer thickness. By increasing the VG insulation layer thickness 15, 32, 44, 57 mm, the loss in column capacity after 5 hours of fire was 30%, 13%, 7% and 5%, respectively. The obtained results demonstrate the validity of the presented approach for estimation of fire endurance and residual strength, as an alternative for fire testing, and for design of fire protection layers for FRP-confined RC columns.

광점퍼코드 (OJC) 보호용 미소 직경 복합재료 스프링 개발 (A Development of Small-diameter Composite Helical Spring for Reinforcement of Optical Fiber Jumper Cord (OJC))

  • 윤영기;박성도;이연수;윤희석;이우일
    • Composites Research
    • /
    • 제15권4호
    • /
    • pp.17-22
    • /
    • 2002
  • 미세 직경을 갖는 복합재료 나선형 스프링 (CS)가 광점퍼코드 (OJC)를 보강하기위한 매체로써 개발되었다. 이 스프링의 외경은 약 2~3mm로써 광점퍼코드에 갑작스런 측면 하중으로 부터 광섬유의 손실을 막기위해 삽입 보강할 수 있도록 제작되었다. 섬유 형태 (Y-type)와 밴드 형태 (B-type)의 복합재료 스프링이 제작되어 그 효과를 비교하였다. 측면 하중에 대한 기계적 특성은 동일 직경의 금속 스프링 및 일반 광점퍼코드의 물성치와 비교하여 제시하였다. 실험 결과로부터 복합재료 스프링이 보강된 광점퍼코드의 경우 굽힘에 대한 높은 저항력을 지니고 있음에 따라 광섬유의 내부 손상에 의한 광 손실의 감소률이 낮음을 알 수 있었다 얻어진 주요 결과들은: (1) Y-type의 CS의 경우 B-type과 비교하여 높은 측압 저항력을 지님을 알 수 있었다 (2) 일반 OJC와 비교하여 CS-OJC의 경우 광 손실이 현격이 낮음을 알 수 있었다. (3) 일반 스프링의 측압 하중시의 응력 분포 형태를 제시하였으며. 실험으로부터 얻어진 결과로부터 복합재료 스프링이 보강된 광점퍼 코드의 경우 매우 높은 구조적 안정성을 보임을 알 수 있었다.