• 제목/요약/키워드: Protection Rate

검색결과 1,732건 처리시간 0.027초

직물의 자외선차단과 세포에 미치는 방호효과 (Protection Effects of Summer Fabrics from Cell Toxicity of UVB)

  • 안령미;이수진;송명견
    • 한국의류학회지
    • /
    • 제21권4호
    • /
    • pp.750-756
    • /
    • 1997
  • The purpose of the study was to investigate a transmittance rate of UVB (Ultraviolet B) through summer fabrics and a protection rate of summer fabric from UVB. The subjects were randomly selected 159 fabrics from Korean common summer fabrics. The protection rates of 159 fabrics from UVB were measured by UVB lamp and UVB sensor, and 14 fabrics among these fabrics were selected for an assay of MTT(3-(4, 5-dimethylthiazol-2-yl) -2, 5 -diphenyltetrazolium). The protection rate of fabrics from cell toxicity of UVB was measured by investigating the difference of the amount of cell toxic substance on between fabrics covered with and without HeLa cell The average protection rate of 159 fabrics from UVB was 95.08%. As result findings, three negative correlations were found between: 1) the transmittance rate of UVB and the amount of MTT on fabrics (y=0.0373+0.O0518 x, r=-0.9323, p<0.001); 2) the air permeability of fabrics and the amount of MTT (r: -0.79, p< 0.01); 3) the air permeability of fabrics and the protection rate of fabrics from UVB (r=0.89, p<0.01). However, there was no effect of thickness of fabrics on the protection rate from UVB and the amount of MTT.

  • PDF

이산 마코프 모델을 이용한 보호 시스템의 고장 비율 추정 (Estimating the Failure Rate of Protection System Using a Discrete Markov Model)

  • 신정진;이희태;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.385-387
    • /
    • 2008
  • When a fault occurs in the distribution system, it is detected by protection system, then protection system is opened and de-energises the feeder where the fault exists. in this paper, the failure rate of protection system will estimate that using a discrete markov approach with failure data of protection system in order to improve the reliability of protection system.

  • PDF

무연 방사선 차폐 시트에 대한 몬테카를로 전산모사 (Monte Carlo Simulation for Radiation Protection Sheets of Pb-Free)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.189-195
    • /
    • 2017
  • 방사선 특히, 엑스선 또는 감마선으로부터 인체를 보호하기 위해 납(Pb)으로 된 보호 장구를 광범위하게 사용해왔다. 최근 납 중독 및 환경오염의 문제로 납을 대신하는 무연 방사선 차폐재의 개발이 활발히 이루어지고 있다. 차폐재의 성능 확보를 위해서는 제작 및 평가의 순환 사이클을 반복하게 된다. 본 연구는 실제 무연 방사선 차폐소재의 제작에 앞서 차폐재의 성능을 몬테카를로 전산모사를 통해 확인함으로써 가능한 차폐소재의 조합을 연구하였다. 방사선 차폐소재의 평가에 사용되는 조건으로 엑스선관을 Geant4를 이용하여 전산모사하고 획득된 광자 스펙트럼을 이용하여 텅스텐과 비스무스의 조합에 따른 차폐소재의 성능을 평가하였다. 차폐소재의 공극에 따른 성능 저하도 평가하였다. 방사선 차폐 소재 개발 시 공극률을 줄이는 것이 중요한 인자라는 것을 알 수 있었다.

해양 금속재료의 부식속도와 방식전류에 미치는 유속의 영향 (Effect of flow velocity on corrosion rate and corrosion protection current of marine material)

  • 이승준;한민수;장석기;김성종
    • Corrosion Science and Technology
    • /
    • 제14권5호
    • /
    • pp.226-231
    • /
    • 2015
  • In spite of highly advanced paint coating techniques, corrosion damage of marine metal and alloys increase more and more due to inherent micro-cracks and porosities in coatings formed during the coating process. Furthermore, flowing seawater conditions promote the breakdown of the protective oxide of the materials introducing more oxygen into marine environments, leading to the acceleration of corrosion. Various corrosion protection methods are available to prevent steel from marine corrosion. Cathodic protection is one of the useful corrosion protection methods by which the potential of the corroded metal is intentionally lowered to an immune state having the advantage of providing additional protection barriers to steel exposed to aqueous corrosion or soil corrosion, in addition to the coating. In the present investigation, the effect of flow velocity was examined for the determination of the optimum corrosion protection current density in cathodic protection as well as the corrosion rate of the steel. It is demonstrated from the result that the material corrosion under dynamic flowing conditions seems more prone to corrosion than under static conditions.

Effect of Chitosan and Tannin Treatment on the Functional Manifestation of Coptidis Rhizoma Dyed Fabrics

  • Ryu, Soo Jin;Bae, Hyun Sook
    • 한국의류학회지
    • /
    • 제42권6호
    • /
    • pp.1016-1024
    • /
    • 2018
  • Lifestyle of Health and Sustainability (LOHAS) influences the development of hygienic and health-oriented functional textile products; consequently, there has been an increase in the prospects for environmentally friendly natural dyeing products with functional and sensitive characteristics. Therefore, the present study expresses a functional manifestation on fabrics by treatment with chitosan and tannin using natural Coptidis Rhizoma. Cotton and wool fabrics dyed with Coptidis Rhizoma after treatment with chitosan and tannin. Consequently, the antibiosis of fabric dyed with Coptidis Rhizoma was excellent with 99.9% bacterial reduction for Staphylococcus aureus and Klebsiella pneumoniae in both fabrics. The deodorization rate was more than 90.0% in both fabrics after 120 minutes. The UV-A protection rate was 88.2% and the UV-B protection rate was 87.7% for cotton. The UV-A protection rate was 88.2% and the UV-B protection rate was 84.3% for wool fabric. Therefore, both of the dyed fabrics showed excellent UV protection by treatment with only chitosan and tannin, without mordants. Therefore, chitosan and tannin treatments were able to manifest functionalities in the fabrics dyed with Coptidis Rhizoma.

해양환경중에서 A1-합금희생양극에 의한 음극방식특성 (A Study on the Characteristics of Cathodic Protection by Al-Alloy Sacrificial Anode in Marine Environment)

  • 이연호
    • 수산해양기술연구
    • /
    • 제28권1호
    • /
    • pp.53-60
    • /
    • 1992
  • In this study, cathodic protection experiment was carried out by Al-alloy sacrificial anode in marine environments which have specific resistance($\rho$) if 25~7000$\Omega$.cm and investigated protection potential, current density and loss rate of Al-alloy sacrificial anode. The main results resistance($\rho$) of 400$\Omega$.cm, the cathodic protection potential appears high about-720 mV(SCE). But below specific resistance($\rho$) of 300$\Omega$.cm, the cathodic protection potential appears low about-770 mV(SCE) and simultaneously, cathode is protected sufficiently. 2) The loss rate of Al-Alloy sacrificial anode became large with decreasing specific resistance and increasing the ratio(A sub(c)/A sub(a) of bared surface area of anode and cathode. 3) The loss rate of Al-alloy sacrificial anode(w) to the mean current density of anode(i) is as follows. w=ai+b (a, b : experimental constants)

  • PDF

Fracture Toughness Evaluation of Natural Gas Pipeline under the Cathodic Protection

  • Kim, Cheol-Man;Baek, Jong-Hyun;Kim, Young-Pyo;Kim, Woo-Sik
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.133-138
    • /
    • 2009
  • For the corrosion protection of the natural gas transmission pipelines, two methods are used, cathodic protection and coating technique. In the case of cathodic protection, defects are embrittled by occurring hydrogen at the crack tip or material surface. It is however very important to evaluate whether cracks in the embrittled area can grow or not, especially in weld metal. In this work, on the basis of elastic plastic fracture mechanics, we performed the CTOD testing with various test conditions, such as testing rate and potential. The CTOD of the base metal and the weld metal showed a strong dependence of the test conditions. The CTOD decreased with decreasing testing rate and with increasing cathodic potential. The morphology of the fracture surface showed the quasi-cleavage at low testing rate and cathodic overprotection. The low CTOD was caused by hydrogen embrittlement at crack tip.

해양환경 중에서 SS400강재의 간극부식방지 특성에 관한 연구 (Study on the Characteristics of Crevice Corrosion Prevention of SS 400 in Marine Environment)

  • 임우조;정기철;구영필;윤병두
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.152-157
    • /
    • 2001
  • This paper was studied on the characteristics of crevice corrosion prevention of SS 400 in marine environment. In NaCl solution, polarization behavior under the crevice corrosion was investigated. And Weight loss rate of SS 400 applied cathodic protection and non cathodic protection was measured according to the NaCl concentration. The main results obtained are as follows : The weight loss rate of Al-alloy galvanic anode was increased as the concentration of NaCl solution increased by 3.5% but the concentration increased over 3.5%, that of Al-alloy galvanic anode become decreased. The protective potential of SS 400 used Al-alloy galvanic anode becomes more cathodic polarization with increasing concentration of NaCl solution. Effects of oxygen on the weight loss rate of Al-alloy sacrificial anode for cathodic protection as the concentration of 3.5% NaCl solution become sensitive than that of 0% NaCl solution.

  • PDF

A Safety Assessment Methodology for a Digital Reactor Protection System

  • Lee Dong-Young;Choi Jong-Gyun;Lyou Joon
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권1호
    • /
    • pp.105-112
    • /
    • 2006
  • The main function of a reactor protection system is to maintain the reactor core integrity and the reactor coolant system pressure boundary. Generally, the reactor protection system adopts the 2-out-of-m redundant architecture to assure a reliable operation. This paper describes the safety assessment of a digital reactor protection system using the fault tree analysis technique. The fault tree technique can be expressed in terms of combinations of the basic event failures such as the random hardware failures, common cause failures, operator errors, and the fault tolerance mechanisms implemented in the reactor protection system. In this paper, a prediction method of the hardware failure rate is suggested for a digital reactor protection system, and applied to the reactor protection system being developed in Korea to identify design weak points from a safety point of view.

방사선방어 앞치마 성능 평가 (Performance Evaluation of Radiation Protection Apron's)

  • 강종구;강병삼
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권5호
    • /
    • pp.373-377
    • /
    • 2019
  • Radiation exposure is on the rise as the working hours of radiation workers increase. Accordingly, the importance of protection products for decreasing the dose of exposure has risen, and excellent X-ray shielding ability and light weight are required. The purpose of this study is to compare the Pb which use currently and other elements in order to reduce the exposure of workers to the most effective protection products. For experiment, we used the general X-ray equipment and angiography equipment, and obtained the Pb and apron's shielding rate. When the shielding rate of Pb and apron was compared in general X-ray equipment, the shielding rate was 95.1% for Pb 0.5 mm, 96.1% for apron 0.5 mmPb and 95.6% for Bi+W 0.5 mmPb. When compared the shielding rate of each aprons in angiography equipment, 0.5 mmPb apron was the highest as 96.4% and Bi+W 0.25 mmPb apron was the lowest as 90.2% at the 50 cm distance. The shielding rate of 0.5 mmPb apron was the highest as 95.7% and Bi+W 0.25 mmPb apron was the lowest as 85.9% at the 100 cm distance. As a result of evaluating the apron efficiency through this study, 0.5 mmPb apron showed the best shielding rate, but it was the heaviest apron. 0.35 mmPb apron and Bi+W 0.25 mmPb apron weighed light but had low shielding rate. Through the results of this experiment, it is recommended that radiation workers reduce radiation exposure by using more efficient protection products.