• Title/Summary/Keyword: Protection Facilities

Search Result 849, Processing Time 0.026 seconds

A Fundamental Research on the Safety Facilities of Railroad (철도 선로안전시설에 관한 기초연구)

  • Lee Seong-Won;Kim Seung-Hwan;Shin Seung-Kyo;Kim Tae-Wook
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.550-555
    • /
    • 2005
  • In this research, safety requirements for guard rail, buffer stop, car stop scotch block, protection device, fire protection facilities, safety siding, escape facilities and inundation protection facilities are studied to establish a standard. First, various kinds of guard rails and their construction methods are investigated. Researches on the level difference of main track and guard rail, joint, length, and fastening force of guard rail are done. Second, the classification of buffer stop and car stop scotch block and its characteristics are examined, and the impact force, speed limit and capacity of buffer stop are summarized. Details of protection device, fire protection facilities, safety siding, escape facilities and inundation protection facilities are also investigated. From this fundamental research results, basic data on the safety facilities of railroad system are established.

  • PDF

Considerations of the Optimized Protective Action Distance to Meet the Korean Protective Action Guides Following Maximum Hypothesis Accidents of Major KAERI Nuclear Facilities

  • Goanyup Lee;Hyun Ki Kim
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.52-57
    • /
    • 2023
  • Background: Korea Atomic Energy Research Institute (KAERI) operates several nuclear research facilities licensed by Nuclear Safety and Security Commission (NSSC). The emergency preparedness requirements, GSR Part 7, by International Atomic Energy Agency (IAEA) request protection strategy based on the hazard assessment that is not applied in Korea. Materials and Methods: In developing the protection strategy, it is important to consider an accident scenario and its consequence. KAERI has tried the hazard assessment based on a hypothesis accident scenario for the major nuclear facilities. During the assessment, the safety analysis report of the related facilities was reviewed, the simulation using MELCOR, MACCS2 code was implemented based on a considered accident scenario of each facility, and the international guidance was considered. Results and Discussion: The results of the optimized protective actions were 300 m evacuation and 800 m sheltering for the High-Flux Advanced Neutron Application Reactor (HANARO), the evacuation to radius 50 m, the sheltering 400 m for post-irradiation examination facility (PIEF), 100 m evacuation or sheltering for HANARO fuel fabrication plant (HFFP) facility. Conclusion: The results of the optimized protective actions and its distances for the KAERI facilities for the maximum postulated accidents were considered in establishing the emergency plan and procedures and implementing an emergency exercise for the KAERI facilities.

A Study on the Efficiency of Children's Shelter in Korea using DEA Analysis Method

  • Jeong, Seong-Bae;Joo, Mi-yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.207-217
    • /
    • 2020
  • The purpose of this study is to analyze the efficiency of Korean child welfare facilities using the DEA analysis method and to present policies. The input variables for the analysis of this data were the number of employees, the number of facilities, and the number of gardens, and the output variables were the current sources. The results of the study are as follows. As a result of CCR analysis, inefficient facilities were found to be temporary protection facilities and comprehensive facilities. As a result of BCC analysis, inefficient facilities were identified as temporary protection facilities. As a result of SE analysis, inefficient facilities were found to be temporary protection facilities. The suggestion is as follows. First, adjustment of the capacity of temporary protection facilities is required. Second, it is necessary to strengthen the professionalism of workers in child welfare facilities. Third, strengthen the expertise of the child welfare facility manager.

Improvement Directions Of Related Laws System To Protect U-City Infrastructure Facilities (U-City 기반시설보호를 위한 관련 법제도 정비 방향)

  • Kim, Byeong-Sun;Lee, Jae-Suk;Shin, Dong-Bin
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.1
    • /
    • pp.45-52
    • /
    • 2011
  • This study aims to provide improvement directions of related laws system to protect U-City infrastructure facilities. For this, the study analyzes oversea infrastructure protection systems and domestic U-City laws system. Then, this indicates problems considering U-City infrastructure protection through Industrial-University-Institute experts' survey. Based on this survey, this study proposes improvement guideline of laws system to protect U-City infrastructure facilities, including enactment the Guideline of U-City Infrastructure Protection, obligation of U-City Infrastructure Protection, revision method of related laws system for protecting intelligent facilities, and Management System of U-City Infrastructure Facilities.

A Study on a Regulation Draft of Inspection and Maintenance for Lightning Protection Facilities based on IEC 62305 (국제표준(IEC 62305) 도입에 따른 피뢰시스템 검사 및 유지관리에 대한 연구)

  • Lee, Kang-Hee;Lee, Sang-Hyup;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.838-844
    • /
    • 2015
  • Latest development of ICT makes building, including houses, factories and public facilities, more intelligent and automatized. It follows that a wide variety of electric and ICT installations are adopted along with micro electronic equipments. Corresponding to such changes, the frequency of lightning increases due to the abnormal climate. The major damage by lightning surge is disconnection and malfunction of facilities. It is necessary, therefore, to make a regulation of inspection and maintenance for lightning protection facilities. This paper deals with main issues of a regulation draft of inspection and maintenance for lightning protection facilities based on IEC 62305

Optimal Operation Methods of Protection Devices in Distribution Systems with PV Systems (태양광전원의 연계에 의한 배전계통 보호기기의 최적 운용방안에 관한 연구)

  • Kim, Byeon-Gi;Park, Jae-Beom;You, Kyeong-Sang;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1485-1491
    • /
    • 2011
  • This paper deals with the technical problems for the protection devices, by simulating test facilities of protection coordination for Photovoltaic systems. In order to analyze the operation characteristics for the protection devices in the case that the Photovoltaic systems with bi-directional power supply are located in the feeder, this paper proposes the test facilities composed of model distribution system, protection device and model Photovoltaic systems. By performing the simulation for operation characteristics for the protection devices based on the test facilities, this paper presents the malfunction mechanism for the protection devices. The test results show that this paper is practical and effective for the technical guideline for the Photovoltaic systems.

A Study on the Needs to Improve the Regulations and the Design Features of Fire Protection for UAE Nuclear Power Plants (UAE원전 화재방호계통 설계특성과 화재방호규제 개선 필요성 연구)

  • Ma, Jin-Soo;Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.54-61
    • /
    • 2011
  • The study is to analysis of fire protection regulations for the nuclear power plants (NPP) in the United States, Japan, the UAE (United Arab Emirates), and Korea with the intention of exporting NPP to the UAE. Fire protection regulations for NPP for these countries permit the fire protection design and facilities in accordance with the evaluation of the potential fire hazards. However, in Korea, the NPP is a part of power generation facilities in Korea fire protection law, and the atomic energy act classifies them as the reactor and related nuclear facilities. The fire protection law and atomic energy act are different to the criteria for the fire protection of NPP. To maintain the leading position as a nuclear exporting country, the performance-based fire hazard analysis should be reasonably incorporated in the design of the fire protection system. It was suggested that the integrated requirements of the fire protection for NPP should be incorporated to the construction article for the fire protection facilities specified in paragraph 2 of Act II, being classified into the special objects to be protected against fire, which requires a performance-based design in order to incorporate the specific requirements for NPP.

Literature Review and Current Trends of Automated Design for Fire Protection Facilities (화재방호 설비 설계 자동화를 위한 선행연구 및 기술 분석)

  • Hong, Sung-Hyup;Choi, Doo Chan;Lee, Kwang Ho
    • Land and Housing Review
    • /
    • v.11 no.4
    • /
    • pp.99-104
    • /
    • 2020
  • This paper presents the recent research developments identified through a review of literature on the application of artificial intelligence in developing automated designs of fire protection facilities. The literature review covered research related to image recognition and applicable neural networks. Firstly, it was found that convolutional neural network (CNN) may be applied to the development of automating the design of fire protection facilities. It requires a high level of object detection accuracy necessitating the classification of each object making up the image. Secondly, to ensure accurate object detection and building information, the data need to be pulled from architectural drawings. Thirdly, by applying image recognition and classification, this can be done by extracting wall and surface information using dimension lines and pixels. All combined, the current review of literature strongly indicates that it is possible to develop automated designs for fire protection utilizing artificial intelligence.

A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses (다중이용업소 실내마감재료 사용기준에 관한 연구)

  • Kim, Yong-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.