• Title/Summary/Keyword: Prosthetic ring

Search Result 24, Processing Time 0.026 seconds

Mitral Valve Reconstruction; Result of Operation Using Prosthetic Ring (승모판막 재건술;인공판륜[prosthetic ring]을 이용한 수술례)

  • 이재원
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.191-195
    • /
    • 1993
  • Among 25 consecutive cases having undergone mitral valve surgery between March 1991 and June 1992 in Gill General Hospital, 11 patients[44%] who had undergone mitral valve reconstruction using prosthetic rings is evaluated and presented. Patients` mean age is 43 + 19 years[range:16-72], and they are consisted with 4 males and 7 females. Mitral valve insufficiency is due to degenerative disease in 6 cases[55%] and rheumatic disease in 5 patients[45%]. Carpentier`s functional classification I is 2 cases, II is 6 cases, and III is 2 cases. Surgical techniques include prosthetic ring annuloplasty[11 patients, 100%], chorda shortening[6, 55%], leaflet mobilization[4,36%], new chorda formation[2, 18%], chorda transposition[1, 9%] commissurotomy[3, 27%], and papillary muscle splitting[3, 27%]. Average number of mitral anatomic lesions per patient are 2.7 and we used average 2.8 procedures upon mitral valve apparatus per patient. There were no surgical mortality and no late valve related admission during the mean follow up period of 17 months. The mean functional class[NYHA] is 2.81 preoperatively and improved to 1.10 postoperatively. Doppler echocardiography showed much improvement from grade II MR [1 case], grade III MR [1 case] and 9 cases of grade IV MR to 6 cases of patients showed no MR, only trace MR in 4 cases, and grade I MR was found only in one patient with NYHA functional class II postoperatively. The postoperative mean mitral valve area is $2.10+0.28cm^2$. We conclude that mitral reconstruction is a predictable and stable operation.

  • PDF

Trido Mitral Valve Replacement with Dacron Collar Prosthetic Valve due to Paravalvular Leak (판막주위 누출에 대한 다크론 확장 인공판막을 이용한 판막치환술 치험)

  • 배윤숙;정성철;김우식;정승혁;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.822-825
    • /
    • 2002
  • The paravalvular leak after redo mitral prosthetic valve replacement is rare but serious complication when it does happen. This condition should be corrected surgically to increase life span and improve symptoms. But simple closure or patch closure of paravalvular leak are not effective in cases of weak annulus or broad defect. We report 3 cases of trido mitral valve replacement using mechanical valve with its sewing ring expanded by a collar of Dacron sheet. The prosthetic sewing ring is anchored on the weak mitral annulus with multiple interrupted sutures, while the Dacron collar is contineuously sutured to the left atrial wall for blood tight sealing. All of the three cases showed event free postoperative course.

Mitral Stenosis by Duran Ring in Children -Two cases report - (소아 환자에서 Duran Ring 사용 후 발생한 승모판협착 -2예 보고-)

  • Kim Kwan Chang;Kim Woong-Han;Choi Sae Hoon;Jang Woo Sung;Yeo In Gwon;Kim Yong Jin
    • Journal of Chest Surgery
    • /
    • v.38 no.12 s.257
    • /
    • pp.849-851
    • /
    • 2005
  • Mitral stenosis was developed after Duran ring annuloplasty in two growing children during follow up period of 8 years and 5 years respectively, which may be due to pannus overgrowth and patient's growing. Only removal of pannus and prosthetic ring has resulted in complete relieving of Mitral stenosis. With time, even adult-sized an-nuloplasty ring may induce stenosis in growing children.

Mitral Reconstruction Using Prosthetic Ring in Mitral Valvular Heart Disease (승모판막질환에 있어서 인공판륜을 이용한 승모판막재건술의 임상적 고찰)

  • 나명훈;황경환
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.598-606
    • /
    • 1997
  • Among 136 patients having undergone mitral valve surgery from September of 1994 through August of 1995 in Sejong Heart Institute, forty four patients(18 males, 26 females) underwent mitral valve reconstruction using prosthetic rings and their clinical results were evaluated. Patients'ages ranged from 5 to 63 years(mean age 38.2 years). Mitral valvular diseases were due to rheumatic origin in 30 patients(68%), degenerative in 13(30%), and congenital in one patient(2%). Mitral regurgitation(MR) was in 33 patients(76%), mitral stenosis 2(5%), and mitral stenoinsufaciency 9 patients(19%). The patients were divided into Carpentier's functional groups : type I, 5 patients(11%) : type I, 24 patients(55%) ; type III, 4 patients (9%) i and mixed(II + III), 11 patients(25%). Average number of anatomic lesions of mitral valve per patient was 3.7. The techniques included prosthetic ring amluloplasty(44 patients, 32 Carpentier ring and 12 Duran ring), leaflet mobilization(24, 55%), chordae shortening(23, 52%), chordae transposition(23, 52%), commissurotomy(16, 35%), leaflet resection(9, 20%), papillary muscle splitting(8, 18%), and chordae reimplantation(1, 2%). Average 3.4 surgical procedures were applied on mitral valve per patient. There were two hospital mortality and one reoperation due to development of MR(grade III) after 2 weeks. During the mean follow up of 12 months, patients improved in terms of functional class of the New York Heart Association, which was mean 3.0 preoperatively and 1.3 postoperatively. Doppler echocardiographic studies showed adequate valve area(2.07$\pm$0.11 cm2 mean $\pm$standard error), improved ventricular contractiliy in 41 patients(93%), ab ence of MR in 23(53%), trace MR in 18(42%), and garde II MR in 2 patients(5%).

  • PDF

Biometric analysis hand parameters in young adults for prosthetic hand and ergonomic product applications

  • Gkionoul Nteli Chatzioglou;Yelda Pinar;Figen Govsa
    • Anatomy and Cell Biology
    • /
    • v.57 no.2
    • /
    • pp.172-182
    • /
    • 2024
  • This study aimed to evaluate the superficial anatomy, kinesiology, and functions of the hand to reveal its morphometry and apply the findings in various fields such as prosthetic hand and protective hand support product design. We examined 51 young adults (32 females, 19 males) aged between 18-30. Hand photographs were taken, and measurements were conducted using ImageJ software. Pearson correlation analysis was performed to determine the relationship between personal information and the parameters. The results of the measurements showed the average lengths of finger segments: thumb (49.5±5.5 mm), index finger (63.9±4.1 mm), middle finger (70.7±5.2 mm), ring finger (65.5±4.8 mm), and little finger (53.3±4.3 mm). Both females and males, the left index finger was measured longer than the right index finger. The right ring finger was found to be longer than the left in both sexes. Additionally, length differences between fingers in extended and maximally adducted positions were determined: thumb-index finger (56.1±6.2 mm), index-middle finger (10.7±4.1 mm), middle-ring finger (10.8±1.4 mm), and ring-little finger (25.6±2.7 mm). Other findings included the average radial natural angle (56.4°±10.5°), ulnar natural angle (23.4°±7.1°), radial deviation angle (65.2°±8.2°), ulnar deviation angle (51.2°±9.6°), and grasping/gripping angle (49.1°±5.8°). The average angles between fingers in maximum abduction positions were also measured: thumb-index finger (53.4°±6.5°), index-middle finger (17.2°±2.6°), middle-ring finger (14.3°±2.3°), and ring-little finger (32.1°±7.0°). The study examined the variability in the positioning of proximal interphalangeal joints during maximum metacarpophalangeal and proximal interphalangeal flexion, coinciding with maximum distal interphalangeal extension movements. The focal points of our observations were the asymmetrical and symmetrical arches formed by these joints. This study provides valuable hand parameters in young adults, which can be utilized in various applications such as prosthetic design, ergonomic product development, and hand-related research. The results highlight the significance of considering individual factors when assessing hand morphology and function.

Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement (경식도 심초음파 검사를 이용한 판막대치술 환자의 평가)

  • 조건현
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF

Study on the Diagnosis of Abnormal Prosthetic Valve

  • Lee, Hyuk-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • The two major problems related to the blood flow in replaced prosthetic heart valve are thrombus formation and hemolysis. Reliability of prosthetic valve is very important because its failure means the death of patient. There are many factors affecting the valvular failures and their representatives are mechanical failure and thrombosis, so early noninvasive detection is essentially required. The purpose of this study is to detect the various thromboses formation by using acoustic signal acquisition and its spectral analysis on the frequency domain. We made the thrombosis models using Polydimethylsiloxane (PDMS) and they are thrombosis model on the disc, around the sewing ring and fibrous tissue growth across the orifice of valve. Using microphone and amplifier, we measured the acoustic signal from the prosthetic valve, which is attached to the pulsatile mock circulation system. A/D converter sampled the acoustic signal and the spectral analysis is the main algorithm for obtaining spectrum. Then the spectrum of normal and 5 different kinds of abnormal valve were obtained. Each spectrum waveform shows a primary and secondary peak. The secondary peak changes according to the thrombus model. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. Acoustic measurement has been used as a noninvasive diagnostic tool and is thought to be a good method for detecting possible mechanical failure or thrombus.

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.6
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

Prosthetic rehabilitation of the edentulous patients using O-ring attachment:A clinical report (O-ring Attachment를 이용한 무치악환자의 보철수복증례)

  • Ahn, Jae-Jin;Jo, Byung-Woan;Ahn, Sang-Hun;Kim, Jong-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.4
    • /
    • pp.581-586
    • /
    • 1998
  • A successful prosthesis is difficult to produce without using the implants in the severely resorbed alveolar ridges and maxillofacial defects. This report describes clinical experience of the overdenture using O-ring attachment. Clinical results have revealed successful application for the O-ring attachment in the two edentulous patients and a partial maxillectomy patient.

  • PDF