• Title/Summary/Keyword: Prosthetic replacement

Search Result 221, Processing Time 0.024 seconds

Clinical Analysis of Bioprosthetic Heart Valves (인공 조직 판막의 임상 성적)

  • 김택진
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1074-1080
    • /
    • 1991
  • A total and consecutive 62 patients between 13 and 58 years of age receiving biological prosthetic heart valves at the Korea University Hospital from January 1978 through October 1983 were analyzed. Out of 71 valves replaced, 64 were Carpentier-Edwards valves, 4 were Ionescu-Shiley valves, 2 were Angell-Shiley valves, 1 was Hancock valve. Early mortality within 30 days after operation was noted in 4 cases[6.4%]. There were no cases of valve-related early death. The 58 early survivors were followed-up for a total 387 patient-year over a period of 3 years to 12 years[Mean$\pm$S.D: 6.37$\pm$2.51 years] at the follow-up end of April 1991. During follow-up, seven patients died and late mortality rate was 12%. There were two major late complications: the one is thromboembolism[1.6% /patient-year], the other is primary tissue failure[2.76% /patient-year]. Ten patients underwent re-replacement of 13 tissue valves because of primary tissue failure[nine Carpentier-Edwards, two Ionescu-Shiley, two Angell-Shiley]. There was operative mortality. The probabilities of freedom from primary tissue failure were 95.4% and 75.3% at 5 and 10 years after operation respectively, The actuarial survival rates were 86.2% and 81.8% at 5 and 10 years after initial surgery respectively.

  • PDF

Isolated aortic valvular heart disease : analysis of etiology and surgical experience (대동맥판막질환의 임상적 고찰 -판막병리 및 임상성적에 대하여-)

  • 이승구
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.300-308
    • /
    • 1987
  • Clinical and pathologic data were reviewed in 20 patients who had have surgery for isolated aortic valvular heart disease between April 1978 and April, 1987. Hospital mortality was 10%, with no additional late mortality during a mean follow-up period of 24.1 months. Prosthetic valve failure developed in 3 patients and two had reoperation. Niety four percent of the survivors who were in NYHA Funtional class III or IV before operation are now in class I or II. Ninety percent of all patients are still alive at a maximum follow up of 9 years. The clinical histories, gross and histologic examination of valves estabilished the causes for isolated aortic valve disease: 3 rheumatic, 2 congenital bicuspid, 2 hypertention, 2 aortitis and each one case of floppy valve, medial cystic necrosis of aorta, bacterial endocarditis. But etiology was unknown in 8 cases. Sixteen patietns had myxoid degeneration, defined as significant disruption of the valve fibrosa and its replacement by acid mucosaccharides and cystic changes. Myxoid degeneration was also the primary pathologic abnormality in the patients with 2 hypertention, 2 rheumatic, 1 aortitis, 1 bacterial endocarditis, 1 floppy valve, 1 congenital bicuspid. The patients with myxoid degeneration of uncertain origin were 8. Histologic finding of all of them revealed nonspecific patients with myxoid degeneration of uncertain orgin were 8. Histologic finding of all of them revealed nonspecific chronic valvulitis with myxoid degeneration. This finding may indicate that the etiology w uld be infectious.

  • PDF

Supravalvular Aortic Stenosis with Aortic Regurgitation (대동맥판막 폐쇄부전증을 동반한 대동맥판막 상부 협착증)

  • 김정태;이철주;소동문;한정선
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.591-594
    • /
    • 1999
  • Supravalvular aortic stenosis is an uncommon, congenital narrowing of the ascending aorta which originates just distal to the level of the ostium of the coronary artery. We conducted a successful surgical treatment in a 39 year- old female patient with a congenital supravalvular aortic stenosis and aortic regurgitation who did not show signs of William's syndrome. After we performed an inverted Y-shaped aortotomy toward the noncoronary sinus and right coronary sinus, pantaloon shaped prosthetic patch(Vascutek, Ino, USA) was used to repair the narrowing sinotubular junction. The aortic valve was replaced concommittently using Sorin Bicarbon 19mm. Her postoperative course was uneventful. The patient discharged at 9th postoperative day in good health.

  • PDF

Esthetic reconstruction of upper central incisor using immediate Frialit-2 implant placement, immediate temporary crown fabrication and IPS Empress 2 crown (즉시 Frialit-2 implant 식립, 즉시 임시치관 제작 그리고 IPS Empress 2 crown을 이용한 상악중절치의 심미적 수복)

  • Kim, Yu-Lee;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.43-48
    • /
    • 2003
  • During the past several years, significant advances have occurred in the utilization of osseointegrated implants for the treatment of partially edentulous patients. One of the biggest purposes for treating of these patients is the high demand for improved esthetics, especially in the anterior region. For this esthetics, the new trend in dental implants is the immediate placement and immediate superstructure fabrication. The refined surgical technique, the skillful soft tissue management, and the proper prosthetic coordination are the main factors to achieve natural looking of implant supported prosthesis. The customized provisional restoration and the customized impression coping are recommended for the optimal peri-implant soft tissue contour. The basic concept of Frialit 2 system was the immediate replacement of a tooth with root-analog fixture after extraction. This system guarantees an ideal result in function and esthetics. The ceramic abutment system offers improved quality in the respect of esthetics, fitness, translucency, and biocompatibility. In this clinical report, the final restoration made with IPS Empress 2 crown on the CeraBase abutmen of Frialit 2 system allowed the reproduction of the natural vitality of tooth and adjacent gingiva.

Research on Ultrasound System and Measurement Technology for Mechanical Defect Monitoring of Human-inserted Artificial Medical Devices (인체 삽입형 인공 의료 기구물 기계적 결함 모니터링을 위한 초음파 시스템 및 계측 기술 연구)

  • Youn, Sangyeon;Lee, Moonhwan;Hwang, Jae Youn
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.470-473
    • /
    • 2021
  • In this study, we developed the biometric ultrasound transducer, residual thickness measurement algorithm and optimized ultrasound operation methods to diagnose precise conditions of implanted medical prosthetic material inserted during total hip artificial joint replacement. In detail, ultrasound transducers having 8 MHz and 20 MHz center frequencies with similar sensitivity and bandwidth were fabricated to measure various thicknesses of commercial polyethylene-based artificial hip liners, resulting in a comparative analysis of signal-to-noise ratio and axial resolution to conduct an optimization study of ultrasound operations in vivo.

  • PDF

Finite element analysis of the femur fracture for a different total hip prosthesis (Charnley, Osteal, and Thompson)

  • Mohammed El Sallah Zagane;Moulgada Abdelmadjid;Murat Yaylaci;Sahli Abderahmen;Ecren Uzun Yaylaci
    • Structural Engineering and Mechanics
    • /
    • v.88 no.6
    • /
    • pp.583-588
    • /
    • 2023
  • Total hip replacement is a crucial intervention for patients with fractured hips who face challenges in natural recovery. The design of durable prostheses requires a comprehensive understanding of the natural processes occurring in bone. This article focuses on static loading analysis, specifically during stumbling activity, aiming to enhance the longevity of prosthetic implants. Three distinct implants, Charnley, Osteal, and Thompson, were selected for a detailed study to determine the most appropriate model. The results revealed critical insights into the distribution of Von Mises stresses on the components of femoral arthroplasty, including the cement, implant, and cortical bone. Furthermore, the examination of shear stress within the cement emerged as a pivotal aspect for all three implants, playing a crucial role in evaluating the performance and durability of hip prostheses. The conclusions drawn from this study strongly suggest that the Thompson model stands out as the most suitable choice for hip joint implants.

Patient-specific implants in reverse shoulder arthroplasty

  • Emil R Haikal;Mohamad Y. Fares;Joseph A. Abboud
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.108-116
    • /
    • 2024
  • Reverse total shoulder arthroplasty (RTSA) is widely popular among shoulder surgeons and patients, and its prevalence has increased dramatically in recent years. With this increased use, the indicated pathologies associated with RTSA are more likely to be encountered, and challenging patient presentations are more likely to be seen. One prominent challenging presentation is RTSA patients with severe glenoid bone loss. Several techniques with varying degrees of invasiveness, including excessive reaming, alternate centerline, bone grafting, and patient-specific implants (PSIs), have been developed to treat patients with this presentation. PSI treatment uses a three-dimensional reconstruction of a computed tomography scan to design a prosthetic implant or component customized to the patient's glenoid morphology, allowing compensation for any significant bone loss. The novelty of this technology implies a paucity of available literature, and although many studies show that PSIs have good potential for solving challenging shoulder problems, some studies have reported questionable and equivocal outcomes. Additional research is needed to explore the indications, outcomes, techniques, and cost-efficiency of this technology to help establish its role in current treatment guidelines and strategies.

A Study on the Manufacture of the Artificial Cardiac Tissue Valve (생체판의 제작 및 실험)

  • Kim, Hyoung-Mook;Song, Yo-Jun;Sohn, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.383-394
    • /
    • 1979
  • Treatment of valvular heart disease with valve replacement has been one of the most popular procedures in cardiac surgery recently. Although, first effort was directed toward the prosthetic valve, it soon became popular that bioprosthesis, the valvular xenograft, was prefered in the majority cases. Valvular xenograft has some superiority to the artificial prosthetic valve in some points of thromboembolism and hemolytic anemia, and it also has some inferiority of durability, immunologic reaction and resistance to Infection. Tremendous efforts were made to cover the inferiority with several methods of collection, preservation, and valve mounting of the porcine valve or pericardium of the calf, and also with surgical technique of the valvular xenograft replacement. Auther has collected 320 porcine aortic valves immediately after slaughter, and aortic cusps were coapted with cotton balls in the Valsalva sinuses to protect valve deformity after immersion in the Hanks' solution, and oxidation, cross-linking and reduction procedures were completed after the proposal of Carpentier in 1972. Well preserved aortic valves were suture mounted in the hand-made tissue valve frame of 19, 21, and 23 mm J.d., and also in the prosthetic vascular segment of 19 mm Ld. with 4-0 nylon sutures after careful trimming of the aortic valves. Completed valves were evaluated with bacteriologic culture, pressure tolerance test with tolerane gauge, valve durability test in the saline glycerine mixed solution with tolerance test machine in the speed of 300 rpm, and again with pathologic changes to obtain following results: 1. Bacteriologic culture of the valve tissue in five different preservation method for two weeks revealed excellent and satisfactory result in view of sterilization including 0.65% glutaraldehyde preservation group for one week bacteriologic culture except one tissue with Citobacter freundii in 75% ethanol preserved group. 2. Pressure tolerance test was done with an apparatus composed of V-connected manometer and pressure applicator. Tolerable limit of pressure was recorded when central leaking jet of saline was observed. Average pressure tolerated in each group was 168 mmHg in glutaraldehyde, 128 mmHg in formaldehyde, 92 mmHg in Dakin's solution, 48 mmHg in ethylene oxide gas, and 26 mmHg in ethanol preserved group in relation to the control group of Ringer's 90 mmHg respectively. 3. Prolonged durability test was performed in the group of frame mounted xenograft tissue valve with 300 up-and-down motion tolerance test machine/min. There were no specific valve deformity or wearing in both 19, 21, and 23 mm valves at the end of 3 months (actually 15 months), and another 3 months durability test revealed minimal valve leakage during pressure tolerance test due to contraction deformity of the non-coronary cusp at the end of 6 months (actually 30 months) in the largest 23 mm group. 4. Histopathologic observation was focussed in three view points, endothelial cell lining, collagen and elastic fiber destructions in each preservation methods and long durable valvular tolerance test group. Endothel ial cell lining and collagen fiber were well preserved in the glutaraldehyde and formaldehyde treated group with minimal destruction of elastic fiber. In long durable tolerance test group revealed complete destruction of the endothelial cell lining with minimal destruction of the collagen and elastic fiber in 3 month and 6 month group in relation to the time and severity. In conclusion, porcine xenograft treated after the proposal of Carpentier in 1972 and preserved in the glutaraldehyde solution was the best method of collection, preservation and valve mounting. Pressure tolerance and valve motion tolerance test, also, revealed most satisfactory results in the glutaraldehyde preserved group.

  • PDF

Mechanical versus Tissue Aortic Prosthesis in Sexagenarians: Comparison of Hemodynamic and Clinical Outcomes

  • Son, Jongbae;Cho, Yang Hyun;Jeong, Dong Seop;Sung, Kiick;Kim, Wook Sung;Lee, Young Tak;Park, Pyo Won
    • Journal of Chest Surgery
    • /
    • v.51 no.2
    • /
    • pp.100-108
    • /
    • 2018
  • Background: The question of which type of prosthetic aortic valve leads to the best outcomes in patients in their 60s remains controversial. We examined the hemodynamic and clinical outcomes of aortic valve replacement in sexagenarians according to the type of prosthesis. Methods: We retrospectively reviewed 270 patients in their 60s who underwent first-time aortic valve replacement from 1995 to 2011. Early and late mortality, major adverse valve-related events, anticoagulation-related events, and hemodynamic outcomes were assessed. The mean follow-up duration was $58.7{\pm}44.0$ months. Results: Of the 270 patients, 93 had a mechanical prosthesis (mechanical group), and 177 had a bioprosthesis (tissue group). The tissue group had a higher mean age and prevalence of preoperative stroke than the mechanical group. The groups had no differences in the aortic valve mean pressure gradient (AVMPG) or the left ventricular mass index (LVMI) at 5 years after surgery. In a sub-analysis limited to prostheses in the supra-annular position, the AVMPG was higher in the tissue group, but the LVMI was still not significantly different. There was no early mortality. The 10-year survival rate was 83% in the mechanical group and 90% in the tissue group. The type of aortic prosthesis did not influence overall mortality, cardiac mortality, or major adverse valve-related events. Anticoagulation-related events were more common in the mechanical group than in the tissue group (p=0.034; hazard ratio, 4.100; 95% confidence interval, 1.111-15.132). Conclusion: The type of aortic prosthesis was not associated with hemodynamic or clinical outcomes, except for anticoagulation-related events.

Open Heart Surgery 600 Cases for 5 Years (5년간 개심술 600예에 관한 검토)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.404-420
    • /
    • 1991
  • Surgical treatment of congenital and acquired heart disease preceded the development of accurate techniques for diagnosis, heart lung machine and cardiopulmonary bypass, intraoperative myocardial protection, operative techniques and cardiac anesthesia. For 5 years from Sep. 1985 to Sep. 1990, six hundred cases of open heart surgeries [OHS] were performed in the department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. The results were summarized as follows. 1. The annual number of OHS[cases per year] was above 100 since 1987, and the increasing rate of cases was 23.5% per year since 1986. 2. Among the total 600 cases, there were 470 cases of congenital heart diseases and 130 cases of acquired. Age range of the congenital patients was 8 months to 44 years with the mean age of 10 years, and acquired patients was 16 to 56 years with the mean age of 36 years. 3. Among the 470 congenital anomalies, there were 429 cases of acyanotic and 41 cyanotic patients. Totally, VSD was 286 cases[60.6%], ASD 103 cases[21.9%], TOF 35 cases [7.4%], PS 20 cases [4.1%], ECD 12 cases [2.0%], Ebstein`s anomaly 3 cases [0.6%], Valsalva sinus rupture 3 cases [0.6%] and others. The appropriate one stage radical operations were applied to the all congenital cases with the result of 2.6% immediate postoperative hospital mortality rate. 4. Among the 130 acquired cases, there were 122 cases of valvular heart diseases, 6 of heart tumors [5 myxoma, one malignant histiocytoma], one of LA thrombus and one of annuloaortic ectasia. Cardiac tumors and LA thrombus were removed through the atrial septal approach. Bentall procedure was adopted to the annuloaortic ectasia case. AVR, MVR and TVA [DeVega procedure] were applied to 120 valve diseases, and there were also one of OMC and one of MVA[Jerome-Kay procedure]. 5. Among the 120 valve replacement cases, there were 87 of single valve replacement cases [AVR: 8, MVR: 79], 11 of double valve replacement [AVR+MVR: 11], 12 of MVR+TVR and 10 of MVR+AVR+TVA. The total number of implanted prosthetic valves were 141. In MVR, 45 of St. Jude Medical valves, 63 of Carpentier-Edward valves and 4 of Ionescu-Shiley valves were used. In AVR, 18 of St. Jude Medical valves and 11 of Carpentier-Edward valves were used. in MVR, 29mm and 31mm sized valves were used mostly and In AVR, 23mm sized valves were used mostly. 6. Postoperatively many kinds of complications were occurred. Among them, wound problems [30 cases], low output syndrome [29 cases], arrhythmia [20 cases], pleural effusion and pneumothorax [13 cases] were occurred frequently. The postoperative immediate hospital mortality was 3.0% in total [congenital 2.6%, acquired 4.6%].

  • PDF