• 제목/요약/키워드: Prosthetic foot

검색결과 17건 처리시간 0.026초

경중족 절단 환자의 의족지 착용에 따른 족저압력 분포 특성 (Characteristics of Foot Pressure Distribution with or without Partial Prosthetic Foot in Transmetartarsal Amputee)

  • 성우성;양희승;성홍기;김학준
    • 대한족부족관절학회지
    • /
    • 제12권1호
    • /
    • pp.41-46
    • /
    • 2008
  • Purpose: This study was designed to evaluate characteristics of foot pressure distribution with or without partial prosthetic foot in transmetatarsal amputee. Materials and Methods: The subjects were 9 transmetatarsal amputees. Foot pressures were measured at hallux, the $1^{st}-5^{th}$ metatarsal head (MTH), mid-foot, condyle area by F-scan system in amputated or contralateral foot during active walking. Results: In amputated foot, mean peak pressure was greatest in midfoot without prosthetic foot but it was greatest in hindfoot with prosthetic foot. In unaffected foot, although mean peak pressure was higher in hallux, and $1-5^{th}$ MTH compared to amputated foot, it was greatest in hind foot both with and without prosthetic foot. However, in unaffected foot, mean peak pressure significantly decreased in hallux and $5^{th}$ MTH after wearing the prosthetic foot. There was a significant difference in mean peak pressure in hallux and $5^{th}$ MTH between amputated and unaffected foot after wearing prosthetic foot. However, other region had no significant difference with or without prosthetic foot between feet. Conclusions: The use of partial prosthetic foot tends to shift weight bearing from the heel area to forefoot and could significantly reduce hind foot peak pressure and redistributed to peak pressure. The partial prosthetic foot can also offer the peak pressure to reduction both amputated foot and unaffected foot and help to toe off during walking.

  • PDF

인공의족의 외반 특성이 하퇴절단자의 무릎과 발목에 미치는 영향 (Effect of Foot Eversion on Knee and Ankle of Trans-tibial Amputees)

  • 배태수;장윤희;김신기;문무성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1505-1508
    • /
    • 2008
  • One of the important functions of prosthetic foot is the foot inversion-eversion which is so important when walking on uneven surfaces. The aim of our study was to evaluate the effect of foot eversion angle especially on knee and ankle joint for transtibial amputees by motion analysis. The experimental data were collected from three transtibial amputees and then ten healthy individuals. To simulate walking on side sloping ground, we used custom-made slope (5, 10, 15 degrees). Motion analysis was performed by 3-dimensional motion analyzer for 6 dynamic prosthetic feet. The results showed that knee abduction moments of amputated leg were decreased but those of sound leg were mainly increased as foot eversion angle increased. And ankle abduction moments of sound leg were inconsistent in magnitude and tendency between control and experimental group. Therefore foot eversioncharacteristics should be considered to develop advanced prosthetic foot.

  • PDF

인공발(Prosthetic Foot) 스프링용 유리섬유강화 적층재의 적층배향에 따른 층간분리거동 해석 (Analysis of Delamination Behavior on the Stacking Sequence of Prosthetic Foot Keel in Glass fiber Reinforced Laminates)

  • 송삼홍;김철웅
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.623-631
    • /
    • 2003
  • It is considered that the application of advanced composite materials to the prostheses for the disables is important to improve their bio-mechanical performance. Particularly, energy storing foot prosthesis is mostly important to restore gait ability of the disables with low-extremity amputation since it could provide propulsion at terminal stance enhancing the disables ability to walk long distance even run and jump. Therefore, the energy storing spring of Prosthetic foot keel under cyclic bending moment use mainly of high strength glass fiber reinforced plastic. The main objective of this study was to evaluate the stacking sequence effect using the delamination growth rate(dA$_{D}$/dN) of energy storing spring in glass fiber reinforced plastic under cyclic bending moment. The test results indicated that the shape of delamination zone depends on stacking sequence in GFRP laminates. Delamination area(A$_{D}$) turns out that variable types with the contour increased non-linearly toward the damage zones.nes.

인공의족의 외반 특성이 하퇴절단자의 무릎과 발목에 미치는 영향 (Effect of Eversion Characteristics on Knee and Ankle Joint of Trans-tibial Amputees)

  • 배태수;장윤희;김신기;문무성
    • 대한기계학회논문집A
    • /
    • 제33권9호
    • /
    • pp.886-891
    • /
    • 2009
  • One of the important functions of prosthetic foot is the foot inversion-eversion which is so important when walking on uneven surfaces. The aim of our study was to evaluate the effect of foot eversion angle especially on knee and ankle joint for transtibial amputees by motion analysis. The experimental data were collected from three transtibial amputees and then ten healthy individuals. To simulate walking on side sloping ground, we used custom-made slope (5, 10, 15 degrees). Motion analysis was performed by 3-dimensional motion analyzer for 6 dynamic prosthetic feet. The results showed that knee abduction moments of amputated leg were decreased but those of sound leg were mainly increased as foot eversion angle increased. And ankle abduction moments of sound leg were inconsistent in magnitude and tendency between control and experimental group. Therefore foot eversioncharacteristics should be considered to develop advanced prosthetic foot.

의지 보행시 의지 무게 분포가 근골격계에 미치는 영향 (Effects of Prosthetic Mass Distribution on Musculoskeletal System during Amputee Gait)

  • 배태수;최환;김신기;문무성
    • 한국정밀공학회지
    • /
    • 제24권8호통권197호
    • /
    • pp.130-137
    • /
    • 2007
  • The optimized prosthetic mass distribution was a controversial problem in the previous studies because they are not supported by empirical evidence. The purpose of the present study was to evaluate the effect of prosthetic mass properties by modeling musculoskeletal system, based on the gait analysis data from two above-knee amputees. The joint torque at hip joint was calculated using inverse dynamic analysis as the mass was changed in knee and foot prosthetic components with the same joint kinematics. The results showed that the peak flexion and abduction torque at the hip joint were 5 Nm and 15 Nm when the mass of the knee component was increased, greater than the peak flexion and abduction torque of the control group at the hip joint, respectively. On the other hand, when the mass of the foot component was increased, the peak flexion and abduction torque at the hip joint were 20 Nm and 15 Nm, greater than the peak flexion and abduction torque of the control, respectively. The hip flexion torque was 4.71-fold greater and 7.92-fold greater than the hip abduction torque for the knee mass increase and the foot mass increase on the average, respectively. Therefore, we could conclude that the effect of foot mass increase was more sensitive than that of knee mass increase for the hip flexion torque. On the contrary, the mass properties of the knee and foot components were not sensitive for the hip abduction torque. In addition, optimized prosthetic mass and appropriate mass distributions were needed to promote efficiency of rehabilitation therapy with consideration of musculoskeletal systems of amputees.

하지 절단환자의 보행 능력 향상을 위한 에너지 저장형 의족의 유연 용골 설계를 위한 기초연구 (A Basic Study on the Design of the Flexible Keel in the Energy-Storage Prosthetic Foot for the Improvement of the Walking Performance of the Below Knee Amputees)

  • 장태성;이정주;윤용산;임정옥
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권5호
    • /
    • pp.519-530
    • /
    • 1998
  • 본 논문에서는 하지 전단 환자의 보행 성능을 개선하고, 활동성을 증대시긴 목적으로 에너지 저장형 의족의 유연 용골 선계를 위한 기초 연구를 수행하였다. 문헌에서 얻을 수 있는 2차원 시상면에서의 정성걸음새와 인체측정 데이터를 분석하여, 의족의 유연 용골 기초 구조 모델을 제시하였다. 기초 구조 모델은 단순한 빔과 선혈 회전 스프링 ·댐퍼로 구성되었다. 고강도 경량 소재를 의족의 유연 용골 기초 구조에 적용하기 위해 탄소섬유 강화 복합재료를 용골의 기초 구조 소재로 선정하였다. 빔의 형상 변화에 따른 복원변형에너지를 유한요소해석에 의해 계산해내고, 빔형상 변화가 설계변수가 될 수 있음을 제시하였다. 복원변형에너지를 많이 저장할 수 있는 유연 용골 구조의 설계를 위해, 직교배열표를 이용한 조지전 시뮬레이션 계획을 세우고, 유한요소 프로그램인 ABAQUS를 이용하여 계획에 따른 유한요소해석을 수행하고, 분산활석을 통해 효과적인 에너지 저장형 의족의 유연 용골 구조를 얻어냈다. 유연 용골 구조를 이용한 의족걸음새의 동적 시뮬레이션 모델을 완성하고, 한 보행 사이클 동안의 동적 해석을 수행하였다. 그리하여 의족 시스템 개발을 위한 효과적 설계 과정이 제시되었다.

  • PDF

유한요소해석과 다구찌방법을 이용한 에너지 저장형 의족용골의 설계에 관한 연구 (A Study on the Design of the Keel in the Energy Storing Prosthetic Foot Using the Finite Element Analysis and the Taguchi Method)

  • 이동희;장태성;이정주;윤용산
    • 대한기계학회논문집A
    • /
    • 제24권3호
    • /
    • pp.613-624
    • /
    • 2000
  • In this study, new design method of prosthetic foot was suggested which can evaluate the performance of prosthetic foot by implementing amputee's gait simulation using the finite element analysis. The basic shape of ESPF(Energy Storing Prosthetic Foot) was designed which is suitable for the below-knee amputee considering mechanical properties and kinematic properties. And, the performance evaluations were performed using the Taguchi method with orthogonal array L25. As a result, average main effect of factors for the ESPF's performance were calculated and then optimum condition of given shape was selected. Essential particulars for the performance evaluation from the simulation result were the quantity of external work needed in stance phase, the quantity of transferred energy from the ESPF through the knee, and the vertical displacement of knee at toe-off. Reasonable optimum condition was obtained from the using performance index. From this study, it was found that it is necessary for the design of ESPF to consider the geometrical data related to the magnitude of load on elastic material.

유한요소 해석기법을 이용한 탄소복합소재 인공발의 설계 (Design of Carbon Composite Prosthetic Feet using Finite Element Methods)

  • 조현석;차국찬;박진국;김신기;이석민;문무성;김창부
    • 한국정밀공학회지
    • /
    • 제30권7호
    • /
    • pp.769-776
    • /
    • 2013
  • The dynamic compliance characteristics of a prosthetic foot midgait are very important for natural performance in an amputee's gait and should be in a range that provides natural, stable walking. In this study, finite element analysis (FEA) and classical laminate theory were used to examine the mechanical characteristics of a carbon-epoxy composite laminate prosthetic foot as a function of variation in the lamination composition. From this analysis, an FEM model of a prosthetic keel, made from the composite material, was developed. The lamination composition of the keel was designed for improved stiffness. The prototype product was fabricated using an autoclave. Vertical loading response tests were performed to verify the simulation model. The results of the experiments were similar to those from simulations below the loading level of the gait, suggesting use of the proposed simulation model for prosthetic keel design.