• Title/Summary/Keyword: Prosthetic and implants

Search Result 217, Processing Time 0.02 seconds

Multidisciplinary approach of the problem of unaesthetic implants in the maxillary anterior dentition (비심미적 임플란트의 심미성 회복을 위한 다각적 접근법)

  • Joo, Ji-Young;Choi, Jeomil;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.126-133
    • /
    • 2015
  • Periodontal tissue destroyed by inflammation is difficult to achieve regeneration of the tissue and esthetic restorations only by surgical methods. In particular, improvement of esthetics is more difficult if the problem is related to the implant. A 23 year old woman suffered from unesthetic anterior implant prosthesis. According to her dental history, a repeated bone graft and soft tissue graft failed at a local dental clinic. It was needed to resolve the inflammation and to improve the esthetics. A free gingival graft and ridge augmentation accompanied by guided bone regeneration and a vascularized interpositional periosteal connective tissue graft was performed. Instead of implant prosthesis, a conventional fixed bridge was adopted for better esthetic result. The patient was satisfied with the esthetic conventional fixed prosthesis. This case report introduces esthetic rehabilitation of unesthetic implant prosthetics in the maxillary anterior dentition by a combination of surgical and prosthetic approaches.

A radiographical study on the changes in height of grafting materials after sinus lift: a comparison between two types of xenogenic materials

  • Hieu, Pham-Duong;Chung, Jin-Hyung;Yim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: The performance of implant surgery in the posterior maxilla often poses a challenge due to insufficient available bone. Sinus floor elevation was developed to increase the needed vertical height to overcome this problem. However, grafting materials used for the sinus lift technique eventually show resorption. The present study radiographically compared and evaluated the changes in height of the grafting materials after carrying out maxillary sinus elevation with a window opening procedure. This study also evaluated the difference between two xenogenic bone materials when being used for the sinus lifting procedure. Methods: Twenty-one patients were recruited for this study and underwent a sinus lift procedure. All sites were treated with either bovine bone (Bio-$Oss^{(R)}$) with platelet-rich plasma (PRP) or bovine bone (OCS-$B^{(R)}$)/PRP. A total of 69 implants were placed equally 6-8 months after the sinus lift. All sites were clinically and radiographically evaluated right after the implant surgery, 7-12 months, 13-24 months, and 25-48 months after their prosthetic loading. Results: Changes of implant length/bone length with time showed a statistically significant decreasing tendency (P<0.05). There was no significant change in the Bio-$Oss^{(R)}$ group (P>0.05). In contrast, the OCS-$B^{(R)}$ group showed a significant decrease with time (P<0.05). However, no significant difference was observed between the two groups (P>0.05). Conclusions: The results showed that there was significant reduction in comparison with data right after placement, after 7 to 12 months, 13 to 24 months, and over 25 months; however, reduction rates between each period have shown to be without significance. No significant difference in height change was observed between the Bio-$Oss^{(R)}$ and the OCS-$B^{(R)}$ groups.

Prosthetic treatment for patient with upper lip cancer and severe periodontitis: Maxillary complete denture with denture adhesive and mandibular double crown-retained removable partial denture (구순암 환자에서의 의치접착제를 이용한 상악 총의치와 심한 치주 상태에서의 하악 이중관의치를 이용한 수복 증례)

  • Choi, Hyun-Suk;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.74-80
    • /
    • 2015
  • When oral cancer is occured, one may experience problems such as lip defect, necrosis of periodontal tissue and cervical caries caused by radiotherapy. According to ADI (Association of dental implantology), recent radiotherapy on jaw bone could be a relative contraindication of implant treatment. Due to this controversy, in most cases, treatment is done with removable dentures rather than implants. Especially, lip defect caused by an oral cancer operation have a serious repercussion on the retention of the denture. In this case report, patient with upper lip cancer had undergone resection primarily and secondary radiotherapy was done periodically. As a result, upper teeth of patient were extracted gradually and lower teeth showed very poor periodontal status. Therefore, Polident$^{(R)}$ denture adhesive cream (GlaxoSmithKline, London, England) was applied on maxillary complete denture to overcome reduced retention due to the lip defect and double crown RPD with friction pin was applied on the mandible successfully for two years.

Effect of femoral mechanical properties on primary stability of cementless total hip arthroplasty: a finite element analysis

  • Reimeringer, Michael;Nuno, Natalia
    • Advances in biomechanics and applications
    • /
    • v.1 no.3
    • /
    • pp.187-210
    • /
    • 2014
  • With the goal of increasing the survivorship of the prosthesis and anticipating primary stability problems of new prosthetic implants, finite element evaluation of the micromotion, at an early stage of the development, is mandatory. This allows assessing and optimizing different designs without manufacturing prostheses. This study aimed at investigating, using finite element analysis (FEA), the difference in the prediction of the primary stability of cementless hip prostheses implanted into a $Sawbones^{(R)}$ 4th generation, using the manufacturer's mechanical properties and using mechanical properties close to that of human bone provided by the literature (39 papers). FEA was carried out on the composite $Sawbones^{(R)}$ implanted with a straight taper femoral stem subjected to a loading condition simulating normal walking. Our results show that micromotion increases with a reduction of the bone material properties and decreases with the augmentation of the bone material properties at the stem-bone interface. Indeed, a decrease of the cancellous Young modulus from 155MPa to 50MPa increased the average micromotion from $29{\mu}m$ up to $41{\mu}m$ (+42%), whereas an increase of the cancellous Young modulus from 155MPa to 1000MPa decreased the average micromotion from $29{\mu}m$ to $5{\mu}m$ (-83%). A decrease of cortical Young modulus from 16.7GPa to 9GPa increase the average global micromotion from $29{\mu}m$ to $35{\mu}m$ (+33%), whereas an increase of the cortical Young modulus from 16.7GPa to 21GPa decreased the average global micromotion from $29{\mu}m$ to $27{\mu}m$ (-7%). It can also be seen that the material properties of the cancellous structure had a greater influence on the micromotion than the material properties of the cortical structure. The present study shows that micromotion predicted at the stem-bone interface with material properties of the $Sawbones^{(R)}$ 4th generation is close to that predicted with mechanical properties of human femur.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF METAL-CERAMIC VERSUS COMPOSITE RESIN-VENEERED METAL CROWNS IN CEMENT-RETAINED IMPLANT-SUPPORTED CROWNS UNDER VERTICAL COMPRESSIVE LOAD

  • Pae, Ahran;Jeon, Kyung-A;Kim, Myung-Rae;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.295-302
    • /
    • 2007
  • Statement of problem. Fracture of the tooth-colored superstructure material is one of the main prosthetic complications in implant-supported prostheses. Purpose. The purpose of this in vitro study was to compare the fracture strength between the cement-retained implant-supported metal-ceramic crowns and the indirect composite resinveneered metal crowns under the vertical compressive load. Material and methods. Standard implants of external type (AVANA IFR 415 Pre-mount; Osstem Co., Busan, Korea) were embedded in stainless steel blocks perpendicular to their long axis. Customized abutments were fabricated using plastic UCLA abutments (Esthetic plastic cylinder; Osstem Co., Busan, Korea). Thirty standardized copings were cast with non-precious metal (Rexillium III, Pentron, Walling ford, Conn., USA). Copings were divided into two groups of 15 specimens each (n = 15). For Group I specimens, metal-ceramic crowns were fabricated. For Group II specimens, composite resin-veneered (Sinfony, 3M-ESPE, St. Paul, MN, USA) metal crowns (Sinfony-veneered crowns) were fabricated according to manufacturer's instructions. All crowns were temporary cemented and vertically loaded with an Instron universal testing machine (Instron 3366, Instron Corp., Norwood, MA, USA). The maximum load value (N) at the moment of complete failure was recorded and all data were statistically analyzed by independent sample t-test at the significance level of 0.05. The modes of failure were also investigated with visual analysis. Results. The fracture strength of Sinfony-veneered crowns ($2292.7{\pm}576.0N$) was significantly greater than that of metal-ceramic crowns ($1150.6{\pm}268.2N$) (P < 0.05). With regard to the failure mode, Sinfony-veneered crowns exhibited adhesive failure, while metal-ceramic crowns tended to fracture in a manner that resulted in combined failure. Conclusion. Sinfony-veneered crowns demonstrated a significantly higher fracture strength than that of metal-ceramic crowns in cement-retained implant-supported prostheses.

Consideration on the esthetic problems from implant cases (임플란트 증례에서 발생하는 심미적 문제점들에 관한 고찰)

  • Lee, Dong-Hyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.39-48
    • /
    • 2015
  • The critical factors affecting the esthetics of anterior implants can be summarized as following: 1) Correct positioning of implant fixture, 2) Enough amount of alveolar bone, 3) Optimum volume of soft tissue. The position of implant is probably the most important factor in obtaining esthetic treatment outcome. The 3-dimensional orientation of implant is determined by the position on the alveolar ridge and its direction. Clinicians often try to mimic natural teeth when fabricating restorations. During the course of esthetic diagnosis and treatment, however, one should not forget to consider the correlation between facial pattern, lips, gingiva, alveolar ridge, as well as remaining dentition. Since anterior region is biologically unfavorable when compared with posterior region, one minor discrepancy in positioning of implant can cause esthetically undesirable treatment outcome. If one understands the biological and prosthetic meaning of implant' s 3-dimensional position, he or she can achieve superior esthetic outcome in anterior region.

3-D Finite element stress analysis in screw-type, cement-type, and combined-type implant fixed partial denture designs (임플란트 상부보철물의 유지형태에 따른 3차원 유한요소 응력분석)

  • Lee, Sung-Chun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.365-375
    • /
    • 2009
  • Statement of problems: Stress analysis on implant components of the combined screw- and cement-retained implant prosthesis has not investigated yet. Purpose: The purpose of this study was to assess the load distribution characteristics of implant prostheses with the different prosthodontic retention types, such as cement-type, screw-type and combined type by using 3-dimensional finite element analysis. Material and methods: A 3-dimensional finite element model was created in which two SS II implants (Osstem Co. Ltd.) were placed in the areas of the first premolar and the first molar in the mandible, and three-unit fixed partial dentures with four different retention types were fabricated on the two SS II implants. Model 1 was a cement-retained implant restoration made on two cement-retained type abutments (Comocta abutment; Osstem Co. Ltd.), and Model 2 was a screw-retained implant restoration made on the screw-retained type abutments (Octa abutment; Osstem Co. Ltd.). Model 3 was a combined type implant restoration made on the cement-retained type abutment (Comocta abutment) for the first molar and the screw-retained type abutment (Octa abutment) for the first premolar. Lastly, Model 4 was a combined type implant restoration made on the screw-retained type abutment (Octa abutment) for the first molar and the cement-retained type abutment (Comocta abutment) for the first premolar. Average masticatory force was applied on the central fossa in a vertical direction, and on the buccal cusp in a vertical and oblique direction for each model. Von-Mises stress patterns on alveolar bone, implant body, abutment, abutment screw, and prosthetic screw around implant prostheses were evaluated through 3-dimensional finite element analysis. Results: Model 2 showed the lowest von Mises stress. In all models, the von Mises stress distribution of cortical bone, cancellous bone and implant body showed the similar pattern. Regardless of loading conditions and type of abutment system, the stress of bone was concentrated on the cortical bone. The von-Mises stress on abutment, abutment screw, and prosthetic screw showed the lower values for the screw-retained type abutment than for the cement-retained type abutment regardless of the model type. There was little reciprocal effect of the abutment system between the molar and the premolar position. For all models, buccal cusp oblique loading caused the largest stress, followed by buccal cusp vertical loading and center vertical loading. Conclusion: Within the limitation of the FEA study, the combined type implant prosthesis did not demonstrate more stress around implant components than the cement type implant prosthesis. Under the assumption of ideal passive fit, the screw-type implant prosthesis showed the east stress around implant components.

A prospective multicenter clinical study on the efficiency of detachable ball- and spring-retained implant prosthesis

  • Min-Jung Kim;Won-Tak Cho;Su-Hyun Hwang;Ji-Hyeon Bae;Eun-Bin Bae;June-Sung Shim;Jong-Eun Kim;Chang-Mo Jeong;Jung-Bo Huh
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.4
    • /
    • pp.202-213
    • /
    • 2023
  • PURPOSE. This prospective clinical study was conducted to evaluate the clinical usefulness of the freely detachable zirconia ball- and spring-retained implant prosthesis (BSRP) through a comparative analysis of screw- and cement-retained implant prosthesis (SCRP). MATERIALS AND METHODS. A multi-center, randomized, prospective clinical study evaluating the clinical usefulness of the detachable zirconia ball- and spring-retained implant prostheses was conducted. Sixty-four implant prostheses in 64 patients were examined. Periodic observational studies were conducted at 0, 3, 6, and 12 months after delivery of the implant prosthesis. Factors such as implant success rate, marginal bone resorption, periodontal pocket depth, plaque and bleeding index, and prosthetic complications were evaluated, respectively. RESULTS. During the 1-year observation period, all implants survived without functional problems and clinical mobility, showing a 100% implant success rate. Marginal bone resorption was significantly higher in the SCRP group than in the BSRP group only at the time of implant prosthesis delivery (P = .043). In all observation periods, periodontal pocket depth was slightly higher in the BSRP group than in the SCRP group, but there was no significant difference (P > .05). The modified plaque index (mPI) scores of both groups were moderate. Higher ratio of a score 2 in modified sulcus bleeding index (mBI) was observed in the BSRP group in the 6- and 12-months observation. CONCLUSION. Within the limitations of this study, the newly developed zirconia ball- and spring-retained implant prosthesis could be considered as an applicable and predictable treatment method along with the existing screw- and cement-retained prosthesis.

Prosthetic rehabilitation of an oligodontia patient with atrophic maxilla (위축된 상악골을 가진 부분무치증 환자의 보철수복)

  • Chi, Seung-Seok;Kim, Ye-Jin;Kang, Hyeon-Goo;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.238-247
    • /
    • 2021
  • Congenital tooth agenesis is the most common developmental dental anomaly, of which oligodontia is defined as the absence of six or more permanent teeth, except the third molars. Tooth agenesis causes malocclusion, alveolar atrophy, aesthetic and psychosocial problems. This clinical report describes a multidisciplinary treatment for a patient diagnosed as oligodontia, who exhibited absence of 14 permanent teeth, atrophy of maxillary alveolar bone, and mandibular protrusion. Restoration space was secured and tooth axis was improved by the extraction of deciduous teeth and orthodontic treatment. However, edge-to-edge bite of posterior teeth and arch dimension discrepancy due to atrophic maxilla was remained. To restore the aesthetics and functionality, implant retained prosthesis was planned. Considering minimal bone grafts, location and number of dental implants and prostheses design were determined. Through the gradual adjustment of provisional restoration, the appropriate centric and eccentric occlusion was reflected into a definitive prosthesis. Currently, stable functional results were attained, however, regular follow up and maintenance care over lifetimes should be performed.

Mini-implant with additional retentive structure by using digital method (부가적인 유지구조를 가진 미니 임플란트의 디지털 수복 증례)

  • Hwang, Su-Hyun;Bae, Eun-Bin;Cho, Won-Tak;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.119-126
    • /
    • 2022
  • Mini-implant has been reported as an alternative method to conventional diameter implants in the treatment of mandibular anterior region with narrow ridge. However, one-piece type mini-implant showed biological and technical complications, such as peri-implantitis by residual cement and prosthetic detachment. Recently, one-piece type mini-implant with additional retentive structure has been introduced to increase the retention and stability of the mini-implant. The mini-implant is based on spreading the upper retentive structure with a spreader and connected it with the inner surface of the zirconia prosthesis. In two cases, we tried to reduce these complications through the mini-implant on the narrow mandibular anterior region, and it was possible to reduce the overall treatment period through a digital system. In this case report, restoration using the digital mini-implant system showed improvement of patient satisfaction on the aspect of function and esthetic in the narrow mandibular anterior region.