• 제목/요약/키워드: Prosthetic Implants

검색결과 216건 처리시간 0.024초

Long-term outcomes of adjacent and antagonistic teeth after implant restoration: a focus on patient-related factors

  • Park, Su-Yeon;Kim, Yong-Gun;Suh, Jo-Young;Lee, Du-Hyeong;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • 제51권2호
    • /
    • pp.135-143
    • /
    • 2021
  • Purpose: To investigate factors affecting the antagonistic and adjacent teeth in patients after implant restoration and prosthetic rehabilitation. Methods: In total, 160 patients who visited Kyungpook National University Dental Hospital for implant surgery, prosthesis placement, and supportive periodontal therapy (SPT) were included in this study. The average follow-up period was 88.06 months, and the maximum was 175 months. Patients' history of smoking, diabetes, hypertension, and osteoporosis was investigated, and panoramic radiographs were taken after surgery and prosthetic treatment. During the follow-up period, extraction and prosthetic/endodontic treatments of the antagonistic and adjacent teeth were analyzed. The statistical analyses were performed using descriptive statistics, the chi-square test, the Fisher exact test, and multiple logistic regression analyses. Results: Treatment was performed on 29.4% of the studied antagonistic teeth with extraction performed in 20.0% and prosthetic treatment in 10.0%. Furthermore, 19.4% of the studied adjacent teeth underwent treatment, of which extraction was performed in 12.5% and prosthetic treatment in 7.5%. The treatment rate for adjacent teeth was 25.3% in smokers, which was higher than that of non-smokers (12.3%) (P=0.039). Patients who were non-adherent to SPT showed a significantly higher rate (19.6%) of antagonistic prosthetic treatment than did those who were adherent (5.5%) (P=0.006). Conclusions: Implant restoration can affect the adjacent and antagonistic teeth. Smoking, osteoporosis history, and absence of SPT may be risk factors for the treatment of the adjacent and antagonistic teeth.

$Renova^{(R)}$ 임플란트 식립 후 단기간의 생존율에 대한 다각적 분석 (Multilateral analysis of $Renova^{(R)}$ implant placement and its Survival rate)

  • 양진혁;김성태;정의원;남웅;정영수;심준성;문홍석;이근우;조규성;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제38권3호
    • /
    • pp.413-428
    • /
    • 2008
  • Purpose: Given the predictability of dental implant procedure from the studies of successful osseointegration, implant dentistry is often the treatment of choice to replace missing teeth in edentulous patient instead of the fixed prosthesis or removable denture. The $Renova^{(R)}$ dental implant has a RBM(Resorbable Blast Media) surface, internal hex prosthetic connection and a tapered design. At this study gives the analysis of the implant and the short term survival rate of the implant. Material and Methods: In this study, a multilateral analysis was performed on the subjects undergoing placement with $Renova^{(R)}$ implant between August 2006 and February 2008 in Yonsei University dental hospital. 96 implants were placed in 56 patients and they were surveyed for cumulative survival rate. Among them 78 implants in 44 patients were surveyed for the rest analyses. Result: 1. The cumulative survival rate was 96.88% of 96 implants in 56 patients. 2. The mean marginal bone loss was 0.803mm and the marginal bone loss in augmentation group has higher value than the marginal bone loss in non augmentation group. 3. The health scale for the implants were 87% in success group, 9% in satisfactory survival group, 1% in compromised survival group, and 3% in failure group. 4. Two implants placed in poor bone posterior area by 2-stage failed during prosthetic procedure. Conclusion: $Renova^{(R)}$ dental implant showed high cumulative survival rate in installation on partial edentulous ridge and could be a predictable implant system.

유한요소법을 이용한 하이브리드형 임플란트의 응력해석 (Stress Analysis of Hybrid Implant Using Finite Element Method)

  • 권영두;장석호;박상현;이상원
    • 대한기계학회논문집A
    • /
    • 제32권3호
    • /
    • pp.290-296
    • /
    • 2008
  • After scientific verification of the osteointegration of dental implants, the overall efficiency of dental implants has been generally accepted. Thus, implants now play a major role in the clinical treatment of an edentulous mandible, and in the prosthetic maintenance equipment for partial edentulous mandible patients. Yet, for the successful long-term maintenance of implants, careful consideration of the bio-mechanics is needed to ensure that the maximum stress in the mandible as a result of chewing is maintained under a critical value. Accordingly, this study focuses on reducing the maximum stresses in an implanted mandible, especially in the cortical bone. Thus, the stresses in the implant and mandible are analyzed using finite element packages, including I-DEAS and NISA II/DISPLAY III, using a local zooming technique for a concentrated stress analysis. In addition, the von-Mises stress and principal stress in the mandible are both checked to determine the best combination.

임플란트 식립을 위해 블록형 자가골이식을 이용한 퇴축된 치조골의 재건 (Atrophic Alveolar Ridge Augmentation using Autogenous Block Bone Graft for Implant Placement)

  • 지영덕;조진형
    • 구강회복응용과학지
    • /
    • 제22권2호
    • /
    • pp.161-171
    • /
    • 2006
  • Endosseous implants have restored normal function and dental health to many patients. When implants were introduced as an effective treatment modality, their efficacy was limited by the amount of available bone. Today, various grafting procedures can surgically create bone width and volume. Implants can be placed in more ideal locations for successful prosthetic reconstruction. The use of autogenous bone grafts represents the "gold standard" for bone augmentation procedures. Either intraoral or extraoral sites may be considered for donor sites. Alveolar ridge augmentation using autogenous bone block, can be done during implant placement or staged with implant placement, after bone graft healing. In the staged technique, a better implant positioning and the use of wide diameter implants are possible. Alveolar ridge augmentation using autogenous block graft is a predictable way of treatment, for the atrophic alveolar ridge before implant placement. The cases presented in this article clinically demonstrate the efficacy of using a autogenous block graft in generating effective new bone fill for dental implant placement.

완전 무치악에서 즉시 부하시와 표준 부하시 임플란트 생존율에 대한 비교 분석: 후향적 연구 (Comparative analysis of immediate functional loading and conventional loading about implant survival rate in the completely edentulous: Retrospective study)

  • 서현수;박준우;홍순민;이석련
    • 대한치과의사협회지
    • /
    • 제52권12호
    • /
    • pp.771-782
    • /
    • 2014
  • Introduction: This study researched the clinical application of immediate functional loading technique about implant survival rate in the completely edentulous and suggested our protocol about surgical & prosthetic procedure. Materials and methods: 32 consecutive patients participated in this study. A total of 242 implants were inserted. In test group, 144 implants were inserted in 19 patients with immediate functional loading with occlusal contact. In control group, 98 implants were inserted in 13 patients and conventional loading was done after 4~6 months. Result: In the immediately loaded implants group, overall cumulative survival rate was 98.6%.

Finite element analysis of the femur fracture for a different total hip prosthesis (Charnley, Osteal, and Thompson)

  • Mohammed El Sallah Zagane;Moulgada Abdelmadjid;Murat Yaylaci;Sahli Abderahmen;Ecren Uzun Yaylaci
    • Structural Engineering and Mechanics
    • /
    • 제88권6호
    • /
    • pp.583-588
    • /
    • 2023
  • Total hip replacement is a crucial intervention for patients with fractured hips who face challenges in natural recovery. The design of durable prostheses requires a comprehensive understanding of the natural processes occurring in bone. This article focuses on static loading analysis, specifically during stumbling activity, aiming to enhance the longevity of prosthetic implants. Three distinct implants, Charnley, Osteal, and Thompson, were selected for a detailed study to determine the most appropriate model. The results revealed critical insights into the distribution of Von Mises stresses on the components of femoral arthroplasty, including the cement, implant, and cortical bone. Furthermore, the examination of shear stress within the cement emerged as a pivotal aspect for all three implants, playing a crucial role in evaluating the performance and durability of hip prostheses. The conclusions drawn from this study strongly suggest that the Thompson model stands out as the most suitable choice for hip joint implants.

The seven-year cumulative survival rate of Osstem implants

  • Kim, Young-Kyun;Kim, Bum-Su;Yun, Pil-Young;Mun, Sang-Un;Yi, Yang-Jin;Kim, Su-Gwan;Jeong, Kyung-In
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권2호
    • /
    • pp.68-75
    • /
    • 2014
  • Objectives: This study was performed to analyze the cumulative survival rate of Osstem implants (Osstem Implant Co., Ltd.) over a seven-year period. Materials and Methods: A total of 105 patients who had 467 Osstem implants that were placed at the Section of Dentistry, Seoul National University Bundang Hospital (Seongnam, Korea) from June 2003 through December 2005 were analyzed. The life table method and a cross-tubulation analysis, log rank test were used to evaluate the survival curve and the influence that the prognostic factors. The prognostic factors, i.e., age and gender of patients, diameter and length, type of implants, bone graft history and loading time were determined with a Cox proportional hazard model based on logistic regression analysis. Results: The seven-year cumulative survival rate of Osstem implants was 95.37%. The Cox proportional hazard model revealed that the following factors had a significant influence on survival rate; increased diameter, reduced prosthetic loading period and performance of bone grafting. Conclusion: The osstem implants showed satisfactory results over the seven-year study period.

Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study

  • Beretta, Mario;Poli, Pier Paolo;Maiorana, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • 제44권4호
    • /
    • pp.184-193
    • /
    • 2014
  • Purpose: The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through an analysis of linear and angular deviations. Methods: Implant position was virtually planned using 3D planning software based on the functional and aesthetic requirements of the final restorations. Computer-aided design/computer-assisted manufacture technology was used to transfer the virtual plan to the surgical environment. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by overlapping the pre- and postoperative computed tomography scans using dedicated software. Results: The comparison of 14 implants showed a mean linear deviation of the implant head of 0.56 mm (standard deviation [SD], 0.23), a mean linear deviation of the implant apex of 0.64 mm (SD, 0.29), and a mean angular deviation of the long axis of $2.42^{\circ}$ (SD, 1.02). Conclusions: In the present study, computer-aided flapless implant surgery seemed to provide several advantages to the clinicians as compared to the standard procedure; however, linear and angular deviations are to be expected. Therefore, accurate presurgical planning taking into account anatomical limitations and prosthetic demands is mandatory to ensure a predictable treatment, without incurring possible intra- and postoperative complications.

구치부에 발치 후 지연 식립된 표준 직경의 임플란트에 대한 임상적, 방사선학적 평가 (CLINICAL & RADIOGRAPHIC EVALUATION FOLLOWING DELAYED IMPLANTATION USING REGULAR DIAMETER IMPLANTS IN THE POSTERIOR REGION)

  • 최정용;이상화;윤현중
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권5호
    • /
    • pp.335-339
    • /
    • 2009
  • The purpose of this study was to evaluate clinical and radiographic changes of regular diameter implants placed in the posterior region. A total of 47 standard diameter implants were consecutively placed in the posterior region of 20 partially edentulous patients. The diameters of the implants were 4.1mm (N=35, 74%) and 4.3mm (N=12, 26%), respectively. Peri-implant bone loss and clinical parameters such as mobility, suppuration, swelling, bleeding on probing (BOP) were evaluated at the baseline and?the final follow-up visit. The age of the patients ranged between 24~82 years (mean age: 54.7 years). The cumulative survival rate of the regular diameter implants loaded for a period of 3-24 months (Mean: $11.7{\pm}7.9$ month) was 100%. The average bone loss over the follow-up was $0.36{\pm}0.67\;mm$. Success rate was 95.7%. Only two implants failed (bone loss exceeding 1mm after 1 year of placement). Some prosthetic complications occurred, such as screw loosening (N=1) and dissolution of cementation material (N=2). The present study describes successful outcome following the use of standard-diameter-implants placed in the posterior region, and further comprehensive maintenance practices and follow-up schedules are required.

OSFE법을 이용하여 식립된 Sintered Porous Surface 임플란트에 대한 후향적 연구 (Retrospective Study of OSFE and Simultaneous Sintered Porous Surface Implant Placement)

  • 문경남;김학균;박광범;김동주;선주림;유재식
    • 구강회복응용과학지
    • /
    • 제24권4호
    • /
    • pp.381-388
    • /
    • 2008
  • 상악 구치부 치조골의 해부학적 한계를 극복하기 위한 다양한 방법들이 시도되고 있다. OSFE법은 상악동거상을 위해 사용되어져 오고 있는 방법중 하나이며 본 연구에서는 Endopore 임플란트를 이용하여 상악동내에서 신생골의 형성을 관찰하였다. 66명의 환자에게 115개의 임플란트를 식립하고 평균 26.3개월동안 방사선학적 검사를 시행하였다. 4환자에게서 5개의 임플란트가 보철수복 후 제거되어 추적기간동안 95.6%의 생존율을 보였다. 상악동내에 형성된 신생골의 높이는 $3.26{\pm}1.04mm$이었다.