• Title/Summary/Keyword: Prosthetic Implants

Search Result 218, Processing Time 0.02 seconds

The clinical prognosis of implants that are placed against super-erupted opposing dentition

  • Kim, Young-Kyun;Ahn, Kyo-Jin;Yun, Pil-Young;Yi, Yang-Jin;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.3
    • /
    • pp.139-143
    • /
    • 2016
  • Objectives: If teeth are missing, super-eruption of teeth in the opposing arch can occur in the area and can change the occlusal plane. When missing teeth are replaced with implants, the oral surgeon must determine whether or not the super-erupted teeth need to be treated in order to normalize the occlusal plane. In this study, we evaluated the clinical prognosis of dentition after implant placement and prosthetic treatment were completed in an occlusal plane altered by super-erupted teeth in the opposing arch without additional treatment of the super-erupted teeth. Materials and Methods: Twenty-two patients (9 males, 13 females) were treated with implants and prosthetics without addressing the super-erupted opposing dentition from April 2004 to August 2012 at Seoul National University Bundang Hospital. A total of 33 implants were placed. Values of crestal bone loss, survival rates, and surgical and prosthetic complications for an average of 29.6 months after prosthetic loading were recorded. Results: In one case, the cover screw was exposed after implant surgery. The mean crestal bone loss was $0.09{\pm}0.30mm$. Of the 33 implants, 31 survived, a survival rate of 93.94%. A prosthetic complication occurred in one case but functioned well after correction. Conclusion: Favorable clinical results from prosthetic complications, crestal bone loss, and implant survival rates were exhibited in implants next to a super-erupted opposing tooth.

Perception on Expectation of Prosthetics and Implant of Workers in Ulsan (울산지역 근로자의 보철물과 임플란트의 기대수준에 대한 인식)

  • Cho, Mi-Suk;Kim, Chang-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.5
    • /
    • pp.281-288
    • /
    • 2014
  • This study has surveyed patient education and counseling, based on the data you want to utilize the expectations on dental prosthetic appliances (denture, bridge) and implants among 307 workers who participated in reservists mobilization training of Hyundai Heavy Industries located in Ulsan City. The reliability of expectations on dental prosthetic appliances and implants were fairly high at cronbach'${\alpha}$ of .971 and .967 respectively. The collected data was analyzed through IBM SPSS Statistics. v. 19.0 program at the significance level of 0.05. The research findings are as follows. First, the expectations on prosthetic appliances scored an average of 3.98. Second, the expectations on implants scored an average of 3.74. Third, the expectations on implants depending on subjective health status scored an average of 3.74, which were statistically significant (p=0.003). Fourth, the differences in expectations on implants depending on the concerns for oral hygiene care scored an average of 3.74, which were statistically significant (0<0.001). Fifth, the expectations on prosthetic appliances and implants were strongly correlated at 0.392. As a result of implants of prosthodontics need for accurate information transfer.

Study about the complications associated with implant surgery and prosthetic treatment (임프란트 수술 및 보철물에 따른 합병증 연구)

  • Lee, Ji-Young;Kim, Young-Kyun;Yun, Pil-Young;Bae, Ji-Hyun;Kim, Jae-Seung
    • The Journal of the Korean dental association
    • /
    • v.47 no.9
    • /
    • pp.585-595
    • /
    • 2009
  • Purpose : The aim of this study was to compare surgical complications between simple implant placement and implant placement combined with complicated surgical procedures. We also evaluated prosthetic complications according to the specific types of prosthesis. Material and Method : A retrospective analysis of dental chart of patients who was performed implant therapy during the period from June 2003 to December 2005 was carried out. This study was performed on 408 patients (208 male, 200 female). In addition, 1671 implants were performed. Based on their medical record and radiographs, the authors evaluated surgical and prosthetic complications, surgical procedures accompanied at the time of implant, risk factors of implant failure etc. Result : Surgical complications were developed on 358 implants(21.4% on total placed implants) and wound dehiscence was most prevalent complication. On maxillary posterior area, surgical complications developed more frequently on implants with major surgery and showed a significant difference. And complication rate of implants accompanied with GBR was higher than that of simple implants placement and also showed significant difference. The implant supported prosthesis showed no statistical difference in the occurrence of complications according to the types of prosthesis, and food retention was the most common post-prosthetic complication. Also we speculated that length and width of implant showed significant correlation to the failure of implant primary osseointegration. Conclusion : Based on the result, clinician should provide more careful maintenance for patients with implant placement accompanied by complicated surgical procedure. And periodic maintenance for the patient is requested for long-term survival of implant therapy.

  • PDF

Retrospective Evaluation of Implant Retained Overdentures Using Two Implants and Locator Attachments in the Edentulous Mandibles (Locator attachment를 이용한 하악 임플란트 유지 피개의치의 후향적 평가)

  • Lee, Ju-Hyoung;Sohn, Dong-Seok;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.153-162
    • /
    • 2013
  • This study compared the marginal bone loss around dental implants that were placed in the canine areas of the mandibles and finded the survival rate of the implants, marginal bone loss around implants and prosthetic complications in 20 patients treated with overdentures retained with Locator attachments. Implants placed in this study showed a 95% survival rate and the average marginal bone loss was 1.21 mm($SD{\pm}0.60mm$) in 94.3 weeks of functional loading. Implant-retained overdentures had various prosthetic complications such as male change, metal cap loosening, Locator attachment loosening, denture teeth change, relining and denture fracture. Implant-retained overdentures using two implants and Locator attachments in the edentulous mandibles is considered as a stable way for long terms because of minimal invasive operation, simple prosthetic process and easy repair.

Attitude and treatment options in implant-supported prosthetics: A survey among a cohort of German dentists

  • Glucker, Carolin;Rauch, Angelika;Hahnel, Sebastian
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • PURPOSE. The aim of the current study was to analyze treatment concepts of a cohort of German dentists for planning, fabrication, and maintenance of implant-supported fixed and removable restorations. MATERIALS AND METHODS. A questionnaire including queries about experiences with implant-supported restorations as well as prosthetic and maintenance treatment concepts for supplying patients with fixed and removable implant-supported prosthetic restorations was developed and sent to 350 dental offices registered in the municipal area of Leipzig, Germany. RESULTS. An overall total of 62 returned questionnaires were included in the analyses, which relates to a response rate of 17.7%. Participating dentists were more involved in the prosthetic aspects of implant dentistry rather than surgery, while prosthetic concepts such as backward planning, digital processing, and application of all-ceramic materials were not commonly performed. Simple attachments were preferred over complex retention systems in removable implant-supported restorations. Tooth/implant-supported fixed denture prostheses as well as removable denture prostheses with supporting posterior implants were not regarded as a favorable treatment option. CONCLUSION. Within the limitations of the study, the data indicate that dentists favor simple and conventional treatment approaches in implant prosthetics. Prosthetic aspects in the planning of implant-supported restorations are often neglected. Prosthetic treatment guidelines and aspects should commonly be considered in the planning phase of implant-supported prosthetic restorations, and awareness should be increased in postgraduate education.

A STUDY OF CLINICAL RESULTS ON STERI-OSS ENDOSSEOUS IMPLANTS (Steri-Oss 임플랜트의 임상 결과에 관한 연구)

  • Min, Young-Kyu;Kweon, Hyeog-Sin;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.258-272
    • /
    • 1998
  • This investigation evaluated patients who received Steri-Oss implants from the Dental Hospital of Chosun University during the period from March 1989 to August 1997. 346 fixtures of 127 patients were included in this study. The results were as follows ; 1.The follow-up period was defined as the period between the surgical placement of the implants and the last follow-up examination. The mean follow-up period was $2.17{\pm}1.21$ years. 2.The period between fixture installation and second surgery was $0.71{\pm}0.44$ years in the maxilla and $0.46{\pm}0.21$ years in the mandible. 3.The number of fixtures which were installed in the upper jaw(112) was less than that in the lower jaw(234) and in the posterior region(260) was more than in the anterior region(86). 4.The length of fixture which was most frequently used was 12 mm and least was 8mm. Screw implants were installed more than cylindrical implants. 3.8mm implant was the most common implans, followed by 4.5mm and 3.25mm. 5.The number of augmentation cases was more than that of non-augmentation cases and the rate of augmentation cases in the maxilla was more than that in the mandible. 6.Implant restorations for partial edentulos patients(94cases) were more than single- tooth implant restorations(33cases) or implant restorations for complete edentulos patients(10cases). 7.Free-standing prostheses for partially edentulous patients were more commom than any other type of connection between implants and natural teeth. 8.Plaque Index($0.95{\pm}0.74$) and Gingival Index($0.31{\pm}0.52$) were very similar around the natural teeth and reflected an acceptable level of plaque and gingivitis control. Mean value for keratinized mucosa index($1.93{\pm}1.20$) remained fairly constant around level 2(1-2 mm keratinized epithelium). 9.Patients were generally satisfied with implant in terms of comfort, function, speech and esthetics. 10.There was not a statistically significant differences in overall survial rate between implants placed in the maxilla (91.5%) and those placed in the mandible (93.8%). Fourteen implants lost before the prosthetic rehabilitation and eleven implants lost following variable periods in function after the prosthetic phase of the treatment. 11.Cause of implant failures was exfoliation or removal of fixture due to non-osseointegration before the prosthetic rehabilitation or due to fracture of fixture, masticatory pain after the prosthetic rehabilitation. 12.The survival rate of Steri-Oss implants using the Kaplan-Meier statistical analysis was 93.8% at 2 year and 86.6% at 5 year, In all cases, implant losses occured predominantly in the healing period. There was a steep decline in the rate of implant loss after the first year. 13.The survival rate of Steri-Oss implants in the anterior region was 94.8% at 2 year and 94.8% at 5 year and that in the posterior region was 92.8% at 2 year and 75.9% at 5 year. In conclusion, this study revealed a number of parameters and guidelines for achieving an optimal success rate in osseointegration.

  • PDF

Biomechanical investigation of maxillary implant-supported full-arch prostheses produced with different framework materials: a finite elements study

  • Mirac Berke Topcu, Ersoz;Emre, Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.346-359
    • /
    • 2022
  • PURPOSE. Four and six implant-supported fixed full-arch prostheses with various framework materials were assessed under different loading conditions. MATERIALS AND METHODS. In the edentulous maxilla, the implants were positioned in a configuration of four to six implant modalities. CoCr, Ti, ZrO2, and PEEK materials were used to produce the prosthetic structure. Using finite element stress analysis, the first molar was subjected to a 200 N axial and 45° oblique force. Stresses were measured on the bone, implants, abutment screw, abutment, and prosthetic screw. The Von Mises, maximum, and minimum principal stress values were calculated and compared. RESULTS. The maximum and minimum principal stresses in bone were determined as CoCr < ZrO2 < Ti < PEEK. The Von Mises stresses on the implant, implant screw, abutment, and prosthetic screws were determined as CoCr < ZrO2 < Ti < PEEK. The highest Von Mises stress was 9584.4 Mpa in PEEK material on the prosthetic screw under 4 implant-oblique loading. The highest maximum principal stress value in bone was found to be 120.89 Mpa, for PEEK in 4 implant-oblique loading. CONCLUSION. For four and six implant-supported structures, and depending on the loading condition, the system accumulated different stresses. The distribution of stress was reduced in materials with a high elastic modulus. When choosing materials for implant-supported fixed prostheses, it is essential to consider both the number of implants and the mechanical and physical attributes of the framework material.

Overcoming and Preventing Dental Implant Complications: Abutment Fracture Case Report

  • Kahm, Se Hoon;Kim, Chang-Hyun;Kim, Sung-Joon
    • Journal of Korean Dental Science
    • /
    • v.6 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • The introduction of osseointegrated dental implants in dentistry brought about a new era in everyday dental practice. For the past 50 years, prosthetic restoration with implant-supported prosthesis has developed into a viable and predictable treatment option. Alongside the increasing use of dental implants is the occurrence of many complications during implant placement (surgery), in the mechanical or prosthetic problem, and in the biological aspect. In particular, abutment or screw fracture as one of the mechanical complications can put the dentist in a tight spot in a clinical situation. It is hard to remove the fractured abutment and screw to restore it properly. Therefore, it is very important that clinicians consider possible complications in advance and make an appropriate treatment plan. We discuss cases of abutment fracture and mechanical/prosthetic complications together with the causes and solutions.

DENTAL IMPLANTS IN EDENTULOUS PATIENTS WITH COGNITIVE DISABILITIES: CASE REPORTS (정신적 장애 환자의 임플란트를 이용한 보철 치료)

  • You, Eun-Kyu;Choi, Sung-Chul;Park, Jae-Hong;Kim, Kwang-Chul
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.7 no.1
    • /
    • pp.11-14
    • /
    • 2011
  • Individuals with cognitive disabilities face many barriers to oral care, often suffering from partial or complete edentulism. While the use of implant reconstruction is becoming more common in general population, such care is still being used infrequently in individuals with intellectual impairment. Because of the patients'oral hygiene practice is poor, special need is required for prosthetic design. These two cases were restored by prostheses using implants. Prosthetic modalities were different but the implants were fully osseointegrated, presenting satisfactory functional and esthetic conditions without clinical or radiographic signs of alterations or pathologies. We report that it is good for cognitive disabilities to give prosthetic treatment using implants.

The long-term evaluation of the prognosis of implants with acid-etched surfaces sandblasted with alumina: a retrospective clinical study

  • Kim, Min-Joong;Yun, Pil-Young;Chang, Na-Hee;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.10.1-10.9
    • /
    • 2020
  • Background: The aim of this study was to evaluate the long-term clinical stability of implants with acid-etched surfaces sandblasted with alumina using retrospective analyses of the survival rate, success rate, primary and secondary stability, complications, and marginal bone loss of the implants. Methods: Patients who had implants placed (TS III SA, SS II SA, SS III SA, and U III SA) with SA surfaces from Osstem (Osstem Implant Co., Busan, Korea) at the Seoul National University Bundang Hospital, from January 2008 to December 2010 were selected for the study. Patients' medical records and radiographs (panorama, periapical view) were retrospectively analyzed to investigate sex, age, location of implantation, diameter, and length of the implants, initial and secondary stability, presence of bone grafting, types of bone grafting and membranes, early and delayed complications, marginal bone loss, and implant survival rate. Results: Ninety-six implants were placed in 45 patients. Five implants were removed during the follow-up period for a total survival rate of 94.8%. There were 14 cases of complications, including 6 cases of early complications and 8 cases of delayed complications. All five implants that failed to survive were included in the early complications. The survival of implants was significantly associated with the occurrence of complications and the absorption of bone greater than 1 mm within 1 year after prosthetic completion. In addition, the absorption of bone greater than 1 mm within 1 year after prosthetic completion was significantly associated with the occurrence of complications, primary stability, and implant placement method. Five cases that failed to survive were all included in the early complications criteria such as infection, failure of initial osseointegration, and early exposure of the fixture. Conclusions: Of the 96 cases, 5 implants failed resulting in a 94.8% survival rate. The failed implants were all cases of early complications such as infection, failure of initial osseointegration, and early exposure of the fixtures. Periimplantitis was mostly addressed through conservative and/or surgical treatment and resulted in very low prosthetic complications. Therefore, if preventive measures are taken to minimize initial complications, the results can be very stable.