• Title/Summary/Keyword: Prosthetic Hand

Search Result 51, Processing Time 0.031 seconds

Development of Customized Prosthetic Hand Using 3D Printing (3D프린팅을 이용한 사용자 맞춤형 의수 개발)

  • Moon, Mikyeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.110-117
    • /
    • 2018
  • The development of prosthetic hand or prosthetic leg equipment is steadily taking place globally. Though it would be difficult to create or feel the same way as a human hand, it would be a great for the amputated person if they can pick things up or do some movement as they want. It has become possible to develop low-cost prosthetic hand according to development of 3D printing technology. If people can develop personalized prosthetic equipment at similar prices to meet this trend, the utilization and penetration rate will be much higher. In this study, it describes how to develop a user-customizable prosthetic hand using 3D printing. To do this, the transformational parameters of prosthetic hand shape modeling are extracted as variability values, and the functions for controlling prosthetic hand motion are designed as software design patterns. This allows people who need a prosthetic hand to have their own prosthetic hand at a fast and affordable price.

Design and Analysis of a Wrist Rotation Module Prototype for Partial Hand Amputees: Effects on Upper Limb Movement (부분 손 절단자를 위한 프로토 타입의 손목 회전 모듈 디자인 제안과 상지 움직임의 영향 분석)

  • Seoyoung Choi;Wonwoo Cho;Keehoon Kim
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.4
    • /
    • pp.367-375
    • /
    • 2023
  • Most partial hand amputees experience limited wrist movement, which hinders the efficient functioning of upper limb, affecting hand-to-use coordination and the usability of the prosthetic hand. This limitation can lead to secondary musculoskeletal issues due to repetitive compensatory movement patterns. However, current partial hand prosthetic lack rotational wrist movement due to challenges in accommodating various hand shapes and limited space. In our study, we proposed a prosthetic hand with a wrist rotation module for partial hand amputees, aiming to reduce compensatory movement. To validate the proposed wrist rotation module, we conducted motion analysis during reach-to-grasp task. Furthermore, during the Jebsen-Taylor hand function test, we evaluated both the effect on upper limb movement and the usability of the prosthetic hand, comparing configurations with and without the wrist rotation module. The results showed that the prosthetic hand equipped with rotational wrist movements reduces compensatory movements and promotes efficient upper limb movement patterns. This finding highlights the value of incorporating a wrist rotation module in prosthetic hands to improve upper limb movement for partial hand amputees.

Development of a Multi-Function Myoelectric Prosthetic Hand with Communicative Hand Gestures (의사표현 손동작이 가능한 다기능 근전 전동의수 개발)

  • Heo, Yoon;Hong, Bum-Ki;Hong, Eyong-Pyo;Park, Se-Hoon;Moon, Mu-Seong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.12
    • /
    • pp.1248-1255
    • /
    • 2011
  • In daily life, another major role of human hand is a communicative function using hand gestures besides grasp function. Therefore, if amputees can express their intention by the prosthetic hand, they can much actively participate in social activities. Thus, this paper propose myoelectric multi-function prosthetic hand which can express 6 useful hand gestures such as Rock, Scissors, Paper, Indexing, Ok and Thumb-up. It was designed as under-actuated structure to minimize volume and weight of the prosthetic hand. Moreover, in order to effectively control various hand gestures by only two EMG sensors, we propose a control strategy that the signal type are expanded as "Strong" and "Light", and hand gestures are hierarchically classified for the intuitive control. Finally, we prove the validity of the developed prosthetic hand with the experiment.

Development of prosthetic hand for detecting grasping force using underactuated mechanism (Underactuated mechanism 을 이용한 파지력 감지 전동의수 개발)

  • Jo, Seong;Jang, Dae-Jin;Baek, Yoon-Su;Yang, Hyun-Seok
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.858-863
    • /
    • 2004
  • In this study, the new prosthetic hand which can perform sensory feedback is developed. Although the continuous development of current prosthetic hands, they have some drawbacks. The drawbacks are the low grasping capabilities, the lack of sensory information given to the user, and so on. Despite the improvement of the function of fingers, the sensory information problem still remains undeveloped. By using differential gear and underactuated mechanical design, it can be solved with the minimum additional weight. And it will be applied to all of the prosthetic hands.

  • PDF

Development of Dry-type Active Surface EMG Electrode for Myoelectric Prosthetic Hand (근전의수용 건식형 능동 표면 근전도 전극의 개발)

  • 최기원;문인혁;추준욱;김경훈;문무성
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2733-2736
    • /
    • 2003
  • This paper proposes a dry-type active surface EMG electrode for the myoelectric prosthetic hand. The designed electrode is small size for embedding in the socket of prosthetic hand, and it has three leads including the reference of signal. To acquire EMG signal rejected the power noise, a precision differential amplifier and various filters such as the band pass filter band rejection filter, low pass and high pass filter are embedded on the electrode. The final output of the electrode is integrated absolute EMG (IEMG) obtained by full rectifier and moving average circuits. From experimental results using the implemented dry-type active surface EMG electrode, the proposed electrode is feasible for the myoelectric prosthetic hand.

  • PDF

Development of Sensory Feedback System for Myoelectric Prosthetic Hand (전동의수 사용자를 위한 감각 측정 및 전달 시스템 개발)

  • Bae, Ju-Hwan;Jung, Sung Yoon;Kim, Shinki;Mun, Museong;Ko, Chang-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.10
    • /
    • pp.851-856
    • /
    • 2015
  • This study aimed to develop a sensory feedback system which could measure force and temperature for the user of myoelectric prosthetic hands. The Sensory measurement module consisted of a force sensing resistor to measure forces and non-contact infrared temperature sensor. These sensors were attached on the fingertips of the myoelectric prosthetic hand. The module was validated by using standard weights corresponding to external force and a Peltier module. Sensory transmission module consisted of four vibration motors. Eight vibration patterns were generated by combining motion of each vibration motor and were dependent on kinds and/or magnitude. The module was verified by using standard weigts and water at varying temperatures. There were correlations of force and temperature between the sensory measurement module and standard weight and water. Additionally, exact vibration patterns were generated, indicating the efficacy of the sensory feedback system for the myoelectric prosthetic hand.

Development of the Myoelectric Hand with a 2 DOF Auto Wrist Module (2 자유도 자동손목관절을 가진 근전 전동의수 개발)

  • Park, Se-Hoon;Hong, Beom-Ki;Kim, Jong-Kwon;Hong, Eyong-Pyo;Mun, Mu-Seong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.8
    • /
    • pp.824-832
    • /
    • 2011
  • An essential consideration to differentiate prosthetic hand from robot hand is its convenience and usefulness rather than high resolution or multi-function of the robot hand. Therefore, this study proposes a myoelectric hand with a 2 DOF auto wrist module which has 6 essential functions of the human hand such as open, grasp, pronation, supination, extension, flexion, which improves the convenience of the daily life. It consists of the 3 main parts, the myoelectric sensor for input signal without additional attachment to operate the prosthetic hand, hand mechanism with high-torqued auto-transmission mechanism and self-locking module which guarantee the safety under the abrupt emergency and minimum power consumption, and dual threshold based controller to make easy for adopting the multi-DOF myoelectric hand. We prove the validity of the proposed system with experimental results.

Development of gripping force and durability test standard for myoelectric prosthetic hand (근전전동의수의 파지력 및 내구성 시험 표준 개발)

  • Gook Chan Cha;Suk-Min Lee;Ki-Won Choi;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.393-399
    • /
    • 2023
  • Upper limb amputees wear an upper limb prosthesis for both aesthetic purposes and functional necessity, and in particular, in the case of amputee with both hands, it is essential to wear a myoelectric prosthetic hand capable of gripping action. The prosthetic hand operated by the EMG signal of the remaining muscles is a public insurance benefit item of the Industrial Accident Compensation Insurance, and test method standards are needed to be developed for the safety of the user and the effectiveness of the product performance. In this study, we developed systems for measuring the gripping force of myoelectric hand prosthesis by a load cell and for durability test of the prosthesis over repeated use with a proximity sensor, and propose a test method standard. Since the international test method standard has not yet been established, it is expected that Korea will be able to play a leading role in this standardization field in the future.