• Title/Summary/Keyword: Prosthesis implantation

Search Result 84, Processing Time 0.034 seconds

Salvage Approaches for Maintaining the Eye Globe in a Glaucomatous Patient with Severe Unilateral Exophthalmos

  • Kim, Eunjik;Yun, Sungho;Kwon, Young-Sam
    • Journal of Veterinary Clinics
    • /
    • v.34 no.2
    • /
    • pp.123-125
    • /
    • 2017
  • An eight-year-old Shih-Tzu dog was referred to Kyungpook National University Veterinary Medical Teaching Hospital because of severe glaucoma and exophthalmos. The symptoms included severe buphthalmos, conjunctival hyperemia, focal dried cornea and discomfort in the affected eye. Although enucleation was considered as a potential intervention measure in light of the severity of symptoms, it was possible to save the globe and relieve symptoms through evisceration, intraocular prosthesis implantation, and lateral canthoplasty. Our experience with this case suggests that symptomatic salvage therapy, rather than enucleation, is an appropriate approach for resolution of exopthalmos and other complications associated with glaucoma surgery.

Debridement, antibiotics, and implant retention in infected shoulder arthroplasty caused by Serratia marcescens: a case report

  • Lim, Sungjoon;Lee, Jun-Bum;Shin, Myoung Yeol;Jeon, In-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.2
    • /
    • pp.154-157
    • /
    • 2022
  • Periprosthetic joint infection (PJI) is one of the most devastating complications that can occur after shoulder arthroplasty. Although staged revision arthroplasty is the standard treatment in many cases, surgical intervention with debridement, antibiotics, and implant retention (DAIR) can be an effective option for acute PJI. We report a complex case of infected reverse shoulder arthroplasty (RSA) in a 73-year-old male. The patient had been previously treated for infected nonunion of a proximal humerus fracture caused by methicillin-resistant Staphylococcus epidermidis. He presented with a sinus tract 16 days after the implantation of RSA and was diagnosed with PJI caused by Serratia marcescens. The patient was successfully treated with DAIR and was free of infection at the last follow-up visit at 4 years postoperatively.

Single-tooth implant restoration with alveolar bone augmentation in the maxillary anterior tooth region: a case report

  • Lee, Seon-Ki
    • International Journal of Oral Biology
    • /
    • v.46 no.4
    • /
    • pp.200-207
    • /
    • 2021
  • In case of gingival recession and alveolar bone defects due to tooth loss for a long period of time in a single tooth in the maxillary anterior region, it is not easy to obtain aesthetic results with a single implant prosthesis. For aesthetic restoration, it is important to preserve hard and soft tissues through alveolar bone augmentation as well as restore harmony with adjacent teeth and soft tissues by placing the implant in an ideal location. In this case, an implant was placed using guided bone regeneration and a connective tissue graft simultaneously with immediate implantation after extraction from the maxillary anterior region where only residual root was left for a long period of time.

Rehabilitation of a patient by converting poorly maintained fixed implant prosthesis into implant overdenture: a case report (기존 임플란트 보철물의 불량한 유지관리를 개선하기 위해 임플란트 피개의치로의 상부 보철물 전환 증례)

  • Kim, Yeong-Kyu;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.127-134
    • /
    • 2022
  • Among many contributing factors of implant failure, excessive loading and inflammation contribute mainly to increasing implant failure rate. Especially, poor oral hygiene around implants is one of the most common reasons for implant failure. When implant prosthesis fails to function, the clinician should re-diagnose and plan treatment using the remaining implants. Additional implantation may be needed to make a new type of prosthesis or either implant-assisted RPD and implant overdenture treatment may be performed using the remaining implants. In this article, a patient whose fixed implant prosthesis in the maxilla had failed of poor oral hygiene maintenance was reported to be recovered with removable implant overdenture by using remaining implant abutments and a milled bar with additional retentive elements. Through this treatment, the clinical results were satisfactory in terms of esthetics, masticatory function recovery and oral hygiene management.

Postpneumonectomy Syndrome after Left Pneumonectomy -one case report- (좌측 전폐절제술후 발생한 Postpneumonectomy Syndrome의 치험 1례)

  • 윤용한;이두연;김부연
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.624-628
    • /
    • 1998
  • Postpneumonectomy syndrome is a rare and delayed complication of left pneumonectomy in most patients with normal mediastinal vascular anatomy. This syndrome is characterized by dyspnea and recurrent pulmonary infection in the remaining right lung that typically occur within the first postoperative year. The condition is believed to be secondary to postsurgical changes that include a marked shift of the mediastinum to the left, clockwise rotation of the heart and great vessels, and herniation of the right lung into the left anterior thorax. These changes lead to compression of the trachea or right main bronchus among the thoracic spine and the right pulmonary artery. We report a case of postpneumonectomy syndrome in 15 year-old girl that followed by left pneumonectomy for bronchiectasis 6 years ago. We have inserted an expandable prosthesis in the left thoracic cavity posterior to the heart. After implantation of an expandable prosthesis, an anatomic reposition of the shifted mediastinum was achieved, which resulted in instantaneous and sustained relief. The post-operative course was uneventful and the patient was followed in OPD from after discharge to now.

  • PDF

THE EFFECT OF SCREW HOLE SEALING METHOD ON ABUTMENT SCREW LOOSENING IN DENIAL IMPLANT (임플랜트 보철물의 나사구멍 봉쇄방법이 지대나사 풀림에 미치는 영향에 관한 연구)

  • Lim, Jae-Bin;Yim, Soon-Ho;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.767-780
    • /
    • 1997
  • One of the most common problems of implant prosthesis is the screw loosening of abutment screws. This brings on discomfort in mastication, inflammation in the peri-implant tissue due to poor oral hygiene and fracture of prosthesis or loss of osseointegration. To prevent screw loosening, appropriate implantation to direct the occlusal force to the long axis of the implant, accurate design of the superstructure, decrease of the occlusal table, and adequate torque on the abutment screw are necessary. In this study the screw loosening torque was evaluated in implants with dimples or flutes in the internal surface of abutment screw holes. The abutments were fastened with slot type and hexagonal type abutment screws and were sealed with vinyl poly siloxane impression and bite registration material respectively. The screw loosening torque was evaluated after 1,800 and 12,600 times loading under a loading machine. The results were as follows. 1. The flute form group showed significantly higher loosening torque compared to the dimple form group and the group with no inner surface treatment (p<0.05). 2. There was no statistical difference in loosening torque according to the sealing materials. 3. The loosening torque according to the types of abutment screw showed no significant difference. 4. The loosening torque was significantly higher after 1800 times loading compared to 12600 times loading(p<0.05). From the above results. it is thought that formation of a flute in the internal surface of the screw hole decreases the chance of screw loosening, but the sealing materials and types of abutment screw did not show significant difference in prevention of screw loosening.

  • PDF

Maxillary Sinus Floor Augmentation Using Autogenous Tooth Bone Graft in Combination with Platelet-Rich Plasma for Dental Implants: Case Series

  • Ha, Jinhee;Jeon, Dohyun;Sung, Iel-Yong;Cho, Yeong-Cheol;Lim, Se-Jeong;Son, Jang-Ho
    • Journal of Korean Dental Science
    • /
    • v.12 no.1
    • /
    • pp.5-12
    • /
    • 2019
  • Purpose: To determine the benefits of autogenous tooth bone (ATB) graft in combination with platelet-rich plasma (PRP) in the rates of success and survival of dental implants placed simultaneously with maxillary sinus floor augmentation (MSFA). Materials and Methods: Patients who visited the Department of Oral and Maxillofacial Surgery at Ulsan University Hospital from 2012 to 2014 and underwent simultaneous placement of implants with MSFA using ATB plus PRP were included in the study. Success and survival rates of the implants were evaluated based on the parameters of age and sex of the patient, site, follow-up period, residual bone height before surgery, diameter, and length of implant, sinus mucosa impairment, and postoperative complications. Result: A total of 23 patients and 67 implants were included in this study. The average age of the patients was $53.78{\pm}10.00$ years. The average follow-up period after installation of the prosthesis was $53{\pm}5$ months. The success and survival rates of the implants after placement of prosthesis were 95.52% and 97.01%, respectively. Conclusion: Combination of ATB and PRP showed high overall success rate, and it can be concluded that this combination is a predictable bone graft procedure for MSFA.

Evaluation of failed implants and reimplantation at sites of previous dental implant failure: survival rates and risk factors

  • Park, Yu-Seon;Lee, Bo-Ah;Choi, Seong-Ho;Kim, Young-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.3
    • /
    • pp.230-241
    • /
    • 2022
  • Purpose: The purpose of this study was to evaluate failed implants and reimplantation survival and to identify the relative risk factors for implant re-failure. Methods: Ninety-one dental implants were extracted between 2006 and 2020 at the National Health Insurance Service Ilsan Hospital, including 56 implants in the maxilla and 35 implants in the mandible that were removed from 77 patients. Patient information (e.g., age, sex, and systemic diseases) and surgical information (e.g., the date of surgery and location of the implants and bone grafts) were recorded. If an implant prosthesis was used, prosthesis information was also recorded. Results: In total, 91 first-time failed dental implants in 77 patients were analyzed. Of them, 69 implants in 61 patients received reimplantation after failure. Sixteen patients (22 implants) refused reimplantation or received reimplantation at a different site. Eight of the 69 reimplants failed again. The 1-year survival rate of the 69 reimplants was 89.4%. Age at reimplantation and smoking significantly increased the risk of reimplantation failure. However, a history of taking anti-thrombotic agents showed a statistically significant negative association with reimplantation failure. Of the failed implants, 66% showed early failure and 34% showed late failure of the initial implantation. All 8 re-failed implants showed early failure. Only 3 of these 8 failed reimplants were re-tried and the second reimplants all survived. Conclusions: The total survival rate of implants, which included reimplants and second reimplants was 99.2%, although the survival rate of the initial implantations was 96.3%. Previous failure did not affect the success of the next trial. Reimplantation failure was more strongly affected by patient factors than by implant factors. Therefore, each patient's specific factors need to be meticulously controlled to achieve successful reimplantation.

Multiple consecutive-biphasic pulse stimulation improves spatially localized firing of retinal ganglion cells in the degenerate retina

  • Jungryul Ahn;Yongseok Yoo;Yong Sook Goo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.27 no.6
    • /
    • pp.541-553
    • /
    • 2023
  • Retinal prostheses have shown some clinical success in restoring vision in patients with retinitis pigmentosa. However, the post-implantation visual acuity does not exceed that of legal blindness. The reason for the poor visual acuity might be that (1) degenerate retinal ganglion cells (RGCs) are less responsive to electrical stimulation than normal RGCs, and (2) electrically-evoked RGC spikes show a more widespread not focal response. The single-biphasic pulse electrical stimulation, commonly used in artificial vision, has limitations in addressing these issues. In this study, we propose the benefit of multiple consecutive-biphasic pulse stimulation. We used C57BL/6J mice and C3H/HeJ (rd1) mice for the normal retina and retinal degeneration model. An 8 × 8 multi-electrode array was used to record electrically-evoked RGC spikes. We compared RGC responses when increasing the amplitude of a single biphasic pulse versus increasing the number of consecutive biphasic pulses at the same stimulus charge. Increasing the amplitude of a single biphasic pulse induced more RGC spike firing while the spatial resolution of RGC populations decreased. For multiple consecutive-biphasic pulse stimulation, RGC firing increased as the number of pulses increased, and the spatial resolution of RGC populations was well preserved even up to 5 pulses. Multiple consecutive-biphasic pulse stimulation using two or three pulses in degenerate retinas induced as much RGC spike firing as in normal retinas. These findings suggest that the newly proposed multiple consecutive-biphasic pulse stimulation can improve the visual acuity in prosthesis-implanted patients.

Esthetic implant restoration in the maxillary anterior missing area with palatal defect of the alveolar bone: a case report (구개부 치조골 결손을 보이는 상악 전치 상실부의 임플란트 심미보철수복: 증례보고)

  • Oh, Jae-Ho;Kang, Min-Gu;Lee, Jeong-Jin;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.291-298
    • /
    • 2017
  • It is challenging to produce esthetic implant restoration in the narrow anterior maxilla region where insufficient volume of alveolar bone could limit the angle and position of implant fixture, if preceding bone augmentation is not considered. Ideal angle and position of implant fixture placement should be established to reproduce harmonious emergence profile with marginal gingiva of implant prosthesis, bone augmentation considered to be preceded before implant placement occasionally. In this case, preceding bone augmentation has been operated before esthetic implant prosthesis in narrow anterior maxilla region. Preceded excessive bone augmentation in buccal area allowed proper angulation of implantation, which compensates unfavorable implant position. Provisional restorations were corrected during sufficient period to make harmonious level of marginal gingiva and interdental papilla. The definite restoration was fabricated using zirconia core based glass ceramic. Functionally and esthetically satisfactory results were obtained.