• Title/Summary/Keyword: Prosthesis implantation

Search Result 81, Processing Time 0.023 seconds

The Analysis of Tracheoesophageal Voice after Near-Total Laryngectomy and Implantation of Provox Prosthesis (후두근전적출술과 Provox 삽입술 후 기관식도발성에 관한 연구)

  • Choi, In-Ja;Choi, Young-Soo;Kim, Jin-Hwan;Ahn, Hwoe-Young
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.2
    • /
    • pp.141-144
    • /
    • 2004
  • Background and Objectives : To compare acoustic, aerodynamic analysis of voice and intelligibility score in patients with near-total laryngectomy and implantation of Provox prothesis. Material and Methods : In order to evaluate the voice characteristics, acoustic, aerodynamic parameter and speech intelligibility were measured in 5 patients after near-total laryngectomy, 5 patients after implantation of Provox prosthesis with total bility were measured in 5 patients after near-total laryngectomy, 5 patients after implantation of Provox prosthesis with total laryngectomy and 10 adults normal speaker. Acoustic analysis was carried out using CSL and aerodynamic analysis was carried out using Aerophon II. Speech sample was recorded and 10 listener was scored for speech intelligibility using a percentage of words correctly identified. Results. Fundamental frequency($F_0$), intensity, jitter, shimmer, maximal phonation time(MPT), subglottic air pressure were used for parameters for voice analysis. There were no significant difference between two group except on fundamental frequency and shimmer. The fundamental frequency was higher in patients with near-total laryngectomy and shimmer was higher in patients after implantation of Provox prosthesis with total laryngectomy. In addition, speech intelligibility was no significant difference between two groups. Conclusion : This results confirm that near-total laryngectomy and implantation of Provox prosthesis provides good voice rehabilitation.

  • PDF

Experimental Evaluation of Algin-coated Vascular Grafts in Dogs (잡견에서의 알진 코팅 인조혈관 삽입실험)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.557-564
    • /
    • 1995
  • Microvel knitted double velour vascular grafts coated with biodegradable algin were evaluated in the canine experimental model as a new biologically coated Dacron graft. Three series of implantations were conducted involving the insertion of 6 mm diameter grafts in the abdominal aortae of mongrel dogs. The first series used the regular Microvel vascular grafts coated with algin,whereas the second and third series used Hemashield [collagen-coated grafts and the regular Microvel grafts with preclotting,respectively as control groups. Each series involved the implantation of one prosthesis for each of 2 preselected periods,namely 3 months and 6 months. In addition,algin-impregnated grafts were implanted for 4 hours,72 hours,2 weeks,and 4 weeks. All grafts were patent when the animals were sacrificed at intervals ranging from 4 hours to 6 months. Histological examinations revealed no obvious or significant differences in the healing characteristics of the algin-coated grafts and the control grafts after 3 months and 6 months of implantation. Endothelial cell-like cells were present on the midsegments of all grafts explanted from animals sacrificed after 3 months and 6 months,except a suspicious finding in the 3 month-implantation animal of a preclotted graft. With special stains,the algin became invisible between the polyester filaments during the first 3 months of implantation. This study has demonstrated that the use of a biodegradable algin coating is a feasible approach as biological sealants for textile arterial prostheses.

  • PDF

Multiple implant therapy with multiple inductions of general anesthesia in non-compliant patients with schizophrenia: A case report

  • Choi, Yong-suk;Kim, Hyungseok;Rhee, Seung-Hyun;Ryoo, Seung-Hwa;Karm, Myong-Hwan;Seo, Kwang-Suk;Kim, Hyun Jeong
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.4
    • /
    • pp.239-244
    • /
    • 2019
  • The effectiveness of dental implants in patients with disability, who are non-compliant during treatment, is controversial because of their poor oral health. Thus, oral health-care and management in such patients is concerning. Moreover, limited information is available on prognosis after implant placement. Herein, we describe a patient with schizophrenia who underwent dental implantation under multiple inductions of general anesthesia (5 times) and required conservative treatment and tooth extraction for multiple dental caries and retained roots because of inadequate oral health-care. Postoperatively, fracture of the prosthodontics and progression of dental caries were observed, and with 3 additional inductions of general anesthesia, conservative treatment, implant surgery, and prosthesis implantation were conducted. Postoperative 12-month follow-up since the last prosthesis implantation showed successful results. For patients with schizophrenia, multiple implantation can reduce horizontal bone loss and achieve aesthetic results compared to treatment with removable prosthodontics and could serve as an alternative treatment modality.

Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report (방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례)

  • Choi, Eun-Joo;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.218-224
    • /
    • 2017
  • The implant-supported fixed dental prosthesis in irradiated maxilla needs meticulous treatment planning due to low bone healing capacity. All-on-4 concept implantation can reduce the number of implants to be placed avoiding bone grafting procedure. Conventionally, prefabricated angled abutments for tilted implants have been used. However, in this case, it was replaced with computer-aided design and computer-aided manufacturing (CAD/CAM) abutment. This case report described all-on-4 concept implantation and fabrication of CAD/CAM zirconia fixed dental prostheses using CAD/CAM titanium abutments.

Transcatheter Mitral Valve Implantation in Open Heart Surgery: An Off-Label Technique

  • Alfonsi, Jacopo;Murana, Giacomo;Corsini, Anna;Savini, Carlo;Di Bartolomeo, Roberto;Pacini, Davide
    • Journal of Chest Surgery
    • /
    • v.50 no.6
    • /
    • pp.467-470
    • /
    • 2017
  • Extensive mitral annulus calcifications are considered a contraindication for valve surgery. We describe the case of a 76-year-old female with severe mitral and aortic stenosis associated with extensive calcifications of the heart. The patient underwent an open mitroaortic valve replacement using transcatheter aortic valve implantation with an Edwards SAPIEN XT valve (Edwards Lifesciences Corp., Irvine, CA, USA) in the mitral position. The aortic valve was replaced using a stentless valve prosthesis (LivaNova S OLO; LivaNova PLC, London, UK). Postoperative echocardiography showed that the prosthetic valve was in the correct position and there were no paravalvular leaks. A bailout open transcatheter valve implantation can be considered a safe and effective option in selected cases with an extensively calcified mitral valve.

Artificial Trachea Covered by Ipithelium (상피세포 피복 인공기관의 개발)

  • 김광택;이윤신
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.739-746
    • /
    • 1997
  • A variety of experiments concerning the development of ideal prosthetic grafts for correcting circumferential tracheal defects have been performed. The requirements for an ideal tracheal prosthesis are impermeability to air, consistency to prevent collapse, and acceptance by the host tissue causing a minimum inflammatory reaction, allowing fibroblastic infiltration and epithelialization. The synthetic material, polyurethane(PU), is known as a biocompatible polymer with an inert component. In this study, the tracheal prosthesis was made from microporous PU(30 micrometer in diameter) coated with gelatin and reinforced with isoplastic rings. This procedure provides the prosthesis with a compression strength. The out side diame er of the prosthesis was 20 mm with a length of 30 mm. The gelatin used in the study was obtained from pig skin and immobilized and cross-linked by irradiation(60 Co gamma ray) to promote host tissue incorporation and render the prosthesis epithelization after implantation. Animal experiments using 10 mongrel dogs were performed to compare three kinds of prosthesis; gelatin coated polyurethane graft, uncoated polyurethane graft, and prosthesisf pericadium complex graft. After 6 weeks of implantation, the epithelialization of implants was seen on the gelatin-coated and prosthesisfpericadium complex grafts. Implanted prosthesis were complicated by airway obstruction due to anastomosis granuloma. Early tracheal stenosis was found in the uncoated graft group. Two kind of anastomosis techniques were tested on the gelatin-coated prosthesis. Everted anastomosis resulted severe granuloma than the inverted anastomosis. In the prosthesislpericadium complex graft, bacteria and inflammation at a anastomotic site was found. Based on these results, gelatin coated porous polyurethane trachea prosthesis is biocompatible and may be useful in clinical application with further investigation.

  • PDF

Effects of a Personalized Nurse-Led Educational Program for New Patients Receiving Oral Anticoagulant Therapy after Mechanical Heart Valve Prosthesis Implantation on Adherence to Treatment

  • Eltheni, Rokeia;Schizas, Nikolaos;Michopanou, Nektaria;Fildissis, Georgios
    • Journal of Chest Surgery
    • /
    • v.54 no.1
    • /
    • pp.25-30
    • /
    • 2021
  • Background: Life-long anticoagulant therapy is mandatory for patients who undergo heart valve replacement with implantation of a mechanical prosthesis. The aim of this study was to investigate the effects of a nurse-led patient educational program concerning oral anticoagulant therapy intake after heart valve replacement surgery on patients' knowledge of important parameters of anticoagulant administration. Methods: In this single-center study, 200 patients who underwent surgical implantation of a mechanical prosthesis were divided into 2 groups. The control group received the basic education concerning oral anticoagulants, while the intervention group received a personalized educational program. Results: Personalized education was correlated with a better regulation of therapeutic international normalized ratio (INR) levels and adequate knowledge among patients. Therapeutic levels of INR were achieved in 45% of the patients during the first month, 71% in the third month, and 89% in the sixth month after discharge in the intervention group, compared to 25%, 47%, and 76% in the control group, respectively. Patients' satisfaction with the information was higher in the intervention group than in the control group. The percentage of satisfaction reached 80% for the intervention group versus 37% for the patients of the control group. Conclusion: The implementation of the nurse-led educational programs was associated with improved clinical results and increased adherence to oral anticoagulant treatment.

Periimplant bone change after alveolar ridge preservation: radiographic retrospective study (발치와 치조제 보존술 후 식립한 임플란트 주위 골 변화: 후향적 방사선학적 분석)

  • Shim, Da-Eun;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.281-290
    • /
    • 2021
  • Purpose. The aim of this study is to evaluate bone change around the implant in patients who underwent alveolar ridge preservation for implantation in the posterior teeth using radiographic data measuring changes of mesial, distal crestal bone level according to post-implantation, post-final prosthesis delivery and follow-up periods. Materials and methods. In total, 36 implants were placed in 32 patients. The mesial and distal crestal bone level of all the areas where alveolar ridge preservation was performed uses panoramic images taken post-implantation, post-final prosthesis delivery, and follow-up period each was measured and evaluated as a vertical value. The following factors were analyzed: associations between changes of crestal bone level and factors (e.g., age, sex, systemic diseases, dentist, implant location, tooth, bone type, membrane). The statistical analysis was performed using the mean, standard deviation and independent t-test, paired t-test (P < .05). Results. Analysis of crestal bone level differences between periods shows statistically significant differences (P < .05). There was no statistically significant difference when the changes of crestal bone level between post-implantation, post-final prosthesis delivery and follow-up periods were correlated with each factors. Conclusion. After alveolar ridge preservation, bone around the implant remained stable during the maintenance period without being affected by the patient and surgical factors, and alveolar ridge preservation is considered a clinically usable procedure.

Bone density around the fixture after function of implant molar prosthesis using CBCT (임플란트 보철 기능후 고정체 주변 콘빔CT 골밀도 평가)

  • Jung, Jae-Hyun;Hwang, In-Taik;Jung, Byung-Hyun;Kim, Jae-Duk;Kang, Dong-Wan
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose : The purpose of this study was to examine the significance of increased bone density according to whether bone grafts were applied using demographic data with Cone Beam Computed Tomography (CBCT) and to compare the bone densities between before and after implant prosthesis using the Hounsfield index. Materials and Methods : Thirty-six randomly selected computed tomography (CT) scans were used for the analysis. The same sites were evaluated digitally using the Hounsfield scale with V-Implant $2.0^{TM}$, and the results were compared with maxillary posterior bone graft. Statistical data analysis was carried out to determine the correlation between the recorded Hounsfield unit (HU) of the bone graft and implant prosthesis using a Mann-Whitney U test and Wilcoxon Matched-pairs test. Results : The bone grafted maxillary posterior teeth showed an increase in the mean values from-157 HU to 387 HU, whereas non-grafted maxillary posterior teeth showed an increase from 62 HU to 342 HU. After implantation, the grafted and non-grafted groups showed significantly higher bone density than before implantation. However, the grafted group showed significantly more changes than the non-grafted group. Conclusion : Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density (Hounsfield scale) and bone grafts in the maxillary molar area.

Early Clinical Experience with Sutureless Aortic Valve Replacement for Severe Aortic Stenosis

  • Kim, Do Jung;Kim, Hyo-Hyun;Lee, Shin-Young;Lee, Sak;Chang, Byung-Chul
    • Journal of Chest Surgery
    • /
    • v.51 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • Background: Sutureless aortic valve replacement (SU-AVR) has been developed as an alternative surgical treatment for patients with symptomatic severe aortic stenosis (AS). The aim of this study was to evaluate the clinical outcomes of SU-AVR through an assessment of hemodynamic performance and safety. Methods: From December 2014 to June 2016, a total of 12 consecutive patients with severe AS underwent SU-AVR. The endpoints were overall survival and valve-related complications (paravalvular leakage, valve thrombosis, migration, endocarditis, and permanent pacemaker implantation). The mean follow-up duration was $18.1{\pm}8.6months$. Results: The mean age of the patients was $77.1{\pm}5.8years$ and their mean Society of Thoracic Surgeons score was $9.2{\pm}17.7$. The mean cardiopulmonary bypass and aortic cross-clamp times were $94.5{\pm}37.3$ minutes and $54.9{\pm}12.5minutes$, respectively. Follow-up echocardiography showed good prosthesis function with low transvalvular pressure gradients (mean, $13.9{\pm}8.6mm\;Hg$ and peak, $27.2{\pm}15.0mm\;Hg$) at a mean of $9.9{\pm}4.2months$. No cases of primary paravalvular leakage, valve thrombosis, migration, or endocarditis were reported. A new permanent pacemaker was implanted in 1 patient (8.3%). The 1-year overall survival rate was $83.3%{\pm}10.8%$. Conclusion: Our initial experience with SU-AVR demonstrated excellent early clinical outcomes with good hemodynamic results. However, there was a high incidence of permanent pacemaker implantation compared to the rate for conventional AVR, which is a problem that should be solved.