• 제목/요약/키워드: Properties of floor

검색결과 315건 처리시간 0.025초

다중동조질량감쇠기를 이용한 단순지지 슬래브의 진동 및 소음저감에 관한 연구 (Vibration and Noise Control of the Simply Supported Slab Using the Multi-tuned Mass Damper)

  • 황재승;홍건호;박홍근
    • 한국소음진동공학회논문집
    • /
    • 제18권10호
    • /
    • pp.1006-1013
    • /
    • 2008
  • In this study, it is outlined that heavy weight floor impact noise induced by the vibration of slab can be reduced using multi tuned mass damper(MTMD) effectively. Substructure synthesis is utilized to develope analytical model of the slab coupled with MTMD and acoustic power is introduced to evaluate the performance of noise control for simplicity. Numerical analysis is carried out to investigate the effect of the properties of MTMD on the vibration and noise control of the simply supported slab. Numerical analysis shows that mass ratio of MTMD is critical on the vibration and noise control of the slab and it is also essential to reduce the vibration in higher modes of slab in the light of its great effect on the radiation of sound.

Risk assessment of steel and steel-concrete composite 3D buildings considering sources of uncertainty

  • Lagaros, Nikos D.
    • Earthquakes and Structures
    • /
    • 제6권1호
    • /
    • pp.19-43
    • /
    • 2014
  • A risk assessment framework for evaluating building structures is implemented in this study. This framework allows considering sources of uncertainty both on structural capacity and seismic demand. In particular randomness on seismic load, incident angle, material properties, floor mass and structural damping are considered; in addition the choice of fibre modelling versus plastic hinge model is also considered as a source of uncertainty. The main objective of this work is to study the contribution of these sources of uncertainty on the fragilities of steel and steel-reinforced concrete composite 3D building structures. The fragility curves are expressed in the form of a two-parameter lognormal distribution where vertical statistics in conjunction with metaheuristic optimization are implemented for calculating the two parameters.

접힘 건축에 나타난 위상기하학적 공간 개념에 관한 연구 (A Study on the Concept of Topological Space shown Folding in Architecture)

  • 황태주
    • 한국실내디자인학회논문집
    • /
    • 제13권3호
    • /
    • pp.69-75
    • /
    • 2004
  • Since 1990s, several rising western architects have been moving their theoretical background from the modern paradigm to new science and philosophy. Architectural spaces are based on the philosophy and science of their own age and the architectural theories made by them. And specially, it seems that topological spaces are different to theoretical backgrounds from idealized spaces of modern architecture. From these backgrounds, this study was performed to search for the spacial relationship and characteristics shown in the recently folding architecture and the results of this study that starts this purpose are as follows. First, the architecture that introduced by the theory of topology has appeared as the circulation forms like as Mobius band or Klein bottle, and was made the space fused with structure pursuing liquid properties of matter. As follows, second, the concept of topological space made the division of traditional concept of floor, wall, ceiling disappeared and had built up the space by continual transformation. Third, about the relationship between two spaces in topological space, the two spaces were happened by transformation of these and they have always continuity and the same quality.

벽식 아파트 구조에서 연결슬래브의 거동특성 (The Behavior of Reinforced Concrete Coupling Slab in Wall-Dominant System)

  • 최윤철;최현기;최창식;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.61-64
    • /
    • 2006
  • A common form of construction for apartment buildings consists of walls and coupling element. But, the structural behavior of coupling element are very complex and affected by the properties of coupling element. The propose of this paper is to evaluation the behavior of coupling element in wall-dominant system. An 1/2 scale three specimens was constructed and under cyclic loads. The specimen was consisted of opening walls and coupling element as well as floor slabs. From the result of this study, in coupling slabs, the stresses were not uniform across the width. And the effective width of coupling slabs was found smaller than the that of predicted from previous studies.

  • PDF

다중질량감쇠기를 이용한 슬래브의 진동 및 소음저감에 관한 연구 (Vibration and noise control of slab using the multi-tuned mass damper)

  • 황재승;김홍진;강경수;홍건호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.659-664
    • /
    • 2008
  • In this study, it is outlined that heavy weight floor impact noise induced by the vibration of slab can be reduced by multi tuned mass damper(MTMD) effectively. Substructure synthesis is utilized to develope analytical model of slab coupled with MTMD and acoustic power is introduced to evaluate the performance of noise control for simplicity. Numerical analysis is carried out to investigate the effect of the properties of MTMD on the vibration and noise control. Numerical analysis shows that mass ratio of MTMD is critical on the vibration and noise control of the slab and it is essential to reduce the vibration in higher modes of slab because it has a great effect on the radiation of sound.

  • PDF

Development and deployment of large scale wireless sensor network on a long-span bridge

  • Pakzad, Shamim N.
    • Smart Structures and Systems
    • /
    • 제6권5_6호
    • /
    • pp.525-543
    • /
    • 2010
  • Testing and validation processes are critical tasks in developing a new hardware platform based on a new technology. This paper describes a series of experiments to evaluate the performance of a newly developed MEMS-based wireless sensor node as part of a wireless sensor network (WSN). The sensor node consists of a sensor board with four accelerometers, a thermometer and filtering and digitization units, and a MICAz mote for control, local computation and communication. The experiments include calibration and linearity tests for all sensor channels on the sensor boards, dynamic range tests to evaluate their performance when subjected to varying excitation, noise characteristic tests to quantify the noise floor of the sensor board, and temperature tests to study the behavior of the sensors under changing temperature profiles. The paper also describes a large-scale deployment of the WSN on a long-span suspension bridge, which lasted over three months and continuously collected ambient vibration and temperature data on the bridge. Statistical modal properties of a bridge tower are presented and compared with similar estimates from a previous deployment of sensors on the bridge and finite element models.

Seismic response of substandard RC frame buildings in consideration of staircases

  • Karaaslan, Ayberk;Avsar, Ozgur
    • Earthquakes and Structures
    • /
    • 제17권3호
    • /
    • pp.283-295
    • /
    • 2019
  • During the seismic performance assessment of existing buildings, staircases are generally not taken into account as structural members but as dead load. Staircases, as secondary structural members, not only serve for connecting successive floors but also provide considerable amount of strength and stiffness to the building which can modify its seismic behaviour considerably. In this parametric study, the influence of staircases on the seismic response of substandard RC frame buildings which differ in number of storey and span, presence of staircase and its position has been examined. Modal Analyses and bi-directional Non-Linear Time History Analyses (NLTHA) were conducted to compare several engineering demand parameters (EDPs) such as inter-storey drift ratio (ISDR), floor accelerations, modal properties, member shear forces and plastic hinge distribution. Additionally, short column effect, variation in shear forces of columns that are attached to the staircase slab, failure and deformation in staircase models have also been investigated. As the staircase was considered in the analytical model, a different damage pattern can be developed especially in the structural components close to staircase.

건축물 화재시 개구분출화염으로 인한 상층부로의 화재확대 위험성평가 방법 구축 (Establishment of the Method for Evaluating the Risk of Fire Spread to the Upper Floors due to Ejected Flame from an Opening in the Building Fires)

  • 신이철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.216-217
    • /
    • 2020
  • As the fire inside the building grows rapidly, ejected flame from an opening occurs due to flashover. As a result, the number of cases where the flame spreads to the exterior of the building and rapidly expands to the upper floor is increasing. In particular, in the case of the fire in the Daebong Green Apartment, Uijeongbu in 2015, it was a case where the flame spread to adjacent buildings due to the opening eruption flame from the first ignited building, causing great damage to three apartments. Therefore, this study is to introduce an international standard under development that estimates the shape and properties of the ejected flame from an opening and quantitatively evaluates the radiant heat flux received by the exterior wall of the building by assuming the occurrence of the ejected flame from an opening.

  • PDF

컴퓨터 비젼을 이용한 원기둥형 물체의 3차원 측정 (3-Dimensional Measurement of the Cylindrical Object Using Computer Vision)

  • 장택준;주기세;한민홍
    • 한국정밀공학회지
    • /
    • 제12권12호
    • /
    • pp.38-44
    • /
    • 1995
  • This paper presents a method to measure the position and orientation of a Cylindrical Object(unknown the eiameter and length) lying on a floor, using a camera. The two extreme cross section of the cylinder will be viewed as distorted ellipese or circular are, while its limb edge will be shown as two straight lines. The diameter of the cylinder is determined from the geometric properties of the two straight lines, which in turn provides information regarding the length of the cylinder. From the 3-dimensional measurement, the 3D coordinates of the center points of the two extreme cross sections are determined to give the position and orientation of the cylinder. This method is used for automated pick-and-place operations of cylinder, such as sheet coils, or drums in warehouses.

  • PDF

시멘트 경화체의 반투과성에 따른 삼투압의 발생에 관한 검토 (Osmotic Pressure Induced by Semi-Permeability of Hardened Cement Paste and Cement Mortar)

  • 배기선;김용로;박선규;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.160-165
    • /
    • 1999
  • Osmotic pressure induced by semi-permeability of hardened cement pasts and cement mortar was studied, which was considered to be a cause of failure such as separation and blistering of floor coatings or wall coatings from the concrete substrate. The specimens with a water cement ratio of 45, 60 and 75% were installed between the solution of sodium chloride and distilled water. First, we measured water flux from distilled water to sodium chloride and the ion flux of Na+ and Cl- through the specimens. Then, we measured osmotic pressure induced by semi-permeability of the specimens using an apparatus which was specially developed for this study. It was made clear that hardened cement paste and cement mortar have properties of semipermeability, and the osmotic pressure is closely related to their water cement ratio. Finally, we calculated the osmotic pressure according to Staverman's equation, which was obtained for organic membranes, and tried to explain quantitatively the observed pressure.

  • PDF