A Study on the Proper Illuminance Considering the Task Amenity of the Occupant in the Office Space (사무공간의 재실자의 작업면 쾌적성을 고려한 적정조도 도출)

  • Kim, In-Hye;Kim, Sung-Kyung;Hong, Won-Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.3
    • /
    • pp.159-167
    • /
    • 2020
  • For modern people who spend most of their time indoors, the indoor environment is very important. The efficiency of work depends on the amenity level of the occupants who use the office space. Therefore, the experiment was conducted to derive the proper illuminance according to the amenity level of the occupants. The experiment was conducted in an office in Chilgok County for 6 days. The illuminance of the indoor was changed every day, the feeling brightness of the occupants was measured every 10 minutes, the eye fatigue was measured every 30 minutes, and the overall illuminance and the work surface illuminance were measured every hour. Experimental results show that the feeling brightness is different depending on the position of the occupants. Also, it was found that the brightness survey preferred by the occupants required more proper illuminance than the brightness. In addition, it is considered that there is a correlation with indoor temperature and humidity as the eye fatigue of occupants. Brightness preference by time of day was analysis from feeling brightness of occupants and preference brightness of occupants, and then it was analyzed like eye fatigue to derive proper illuminance per hour. Based on these results, it can be utilized for improvement of eye amenity existing office space.

A Study on the Illuminance Measurement and Improvement of Public Libraries in Daegu City (공공도서관 조도분석 및 개선방안 연구 - 대구지역을 중심으로 -)

  • Yoon, Hee-Yoon
    • Journal of Korean Library and Information Science Society
    • /
    • v.48 no.4
    • /
    • pp.1-20
    • /
    • 2017
  • The most important identity of public library is local public goods that guarantee access and use of knowledge and information of local residents. To justify this, the library must create an optimal lighting environment. Particularly, since the perception rate of information through vision is over 80%, it is necessary to secure proper illuminance. This study measured the illuminance level of public libraries in Daegu. Based on the results, this study suggested a desirable illuminance level for each space and proposed plans to secure and maintain proper illuminance(prospective revision of the KS A 3011, setting the illuminance range for each space of the local government, replacing the existing lighting fixtures with LED, enhance supervision of lighting management, establishment of basic principles for proper lighting and detailed plans for each space of the library, investigation and reflection on users' complaints and satisfaction, etc.)

Analysis of User Preference about the Color Rendering Index, Correlated Color Temperature and Illuminance of LED Lighting in Merchandising Spaces (상업공간에서의 사용자 선호 LED 조명 연색지수와 상관색온도, 조도의 분석)

  • Lee, Su-Jung;Yoon, Hea-Kyung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.1
    • /
    • pp.99-106
    • /
    • 2019
  • This study aims to recommend the proper Color rendering index (CRI), the Correlated Color Temperature (CCT), and illuminance levels of Light-Emitting Diode (LED) lighting based on the analysis of the criteria of the current CRI, the CCT, and illuminance levels in merchandising spaces with LED lighting conditions. It would be a basic material to apply in line with user preference for LED merchandising lighting. To this end, it examines relevant literature review on the experiments designed to test whether lighting characteristics affect brightness perception, color appearance, and pleasantness. Highly saturated colors appear brighter than low saturated colors. Two lighting applications - grocery and clothing shop - were created in elaborating the effect of LED lighting characteristics of CRI on color appearance and the CCT and illuminance on pleasantness. The findings show that the criteria of CIE Ra<80 are appropriate to provide better color appearance of illuminated products in terms of LED lighting that can enhance color saturation, particularly for the red color. Furthermore, 2700 K and less than 500 lux for grocery, 4000 K and more than 500 lux for clothing shop are found to be the proper the CCT and illuminance levels respectively to bring better preference under LED lighting.

The Method of Improvement by Illuminance Measurement of the CT Scan Room in a General Hospital Radiology (종합병원 영상의학과 CT 검사실의 조도 측정에 의한 향상 방안)

  • Kweon, Dae-Cheol;Yang, Sung-Hwan;Kang, Young-Sig
    • Journal of the Korean Institute of Plant Engineering
    • /
    • v.23 no.4
    • /
    • pp.51-56
    • /
    • 2018
  • Computed tomography (CT) scan room in the department of radiology is very necessary to maintain pleasant and proper illuminance to relieve fatigue and inconvenience because it affects the work environment to the radiologist. Accordingly, this paper describes the method for measurement of illuminance that exposed to an environmental elements in a CT scan room of the hospital. Therefore, the purpose of this paper is to propose an optimal environment of CT scan room based on the measurement of illuminance. In addition, the 5 point method by KS C7612 was applied to measure the illuminance with illuminometer (Unfors xi light probe) in the CT scan room. In result of this paper, minimum value and maximum value of illuminance in the CT scan room was measured 212.7 lux and 354.8 lux, respectively. The illuminance of CT scan room was lower than KS A 3011. Finally, the work environment in CT scan room should provide higher illuminance for the comfortable environment of radiologists and patients.

An Experimental Study to Determine Proper Lighting Conditions in Powder Rooms

  • Kim, Hyun-Ji;Lim, Jang-Hyeon;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.54-62
    • /
    • 2013
  • In this study, a mock powder room was installed with variable LED lighting environments in order to conduct the experiments. The experimental conditions include luminaire type, illuminance ratio, vertical illuminance and color temperatures. The evaluation methods used were the Semantic Differential Method and a subjective evaluation on activities through observation. The SD evaluation result factor analysis categorizes ideas into three factors: brightness, emotion, and glare. The vertical bracket or the combined luminaire (luminous panel+ Vertical bracket) has better brightness than luminous panel. A vertical illuminance of 500lx is not significantly difference as compared to 600lx, allowing 500lx to be considered standard. The emotional atmosphere is evaluated as being better at lower color temperature. The luminous panel is the best for reducing glare while the vertical bracket is the worst. The best conditions differ according to the illuminance ratio of the luminous panel and vertical bracket. In the subjective evaluation (satisfaction with lighting environment, suitability to activity) the combined luminaire and 4000K received the best evaluation.

A Study of Luminous Environment for Standard Illuminance in Residential Areas (주거공간의 실내공간별 조도기준을 위한 빛환경 연구)

  • Lee, Jung-Eun;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.1-9
    • /
    • 2005
  • Light is an important environmental element for people to live and do creative activities in residential areas. Especially, people are used to live under artificial light in artificial interior surroundings for the most times. Currently, the lighting quality of residential areas has been improved, but it still does not reach to the recommended level because the luminous environment of present residential areas is only based on the life behavior which puts its priority to clear vision. Therefore, it is necessary that proper standard illumination must be used for various uses and purposes. From this point of view, this paper investigated the essence of light in residential areas, and the luminous environment for apartments was measured This paper finally established well-coordinated standard illuminance, derived from the measurement and analysis of luminous environment from these cases.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.

The Characteristics of the winter season window and indoor temperature due to the indoor plant (동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구)

  • Yun, Young-Il;Cho, Ju-Young
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

Performance Assessment of Light Pipe System for the Advanced Luminous Environment of the Underground Parking Lot (지하주차장 빛환경 개선을 위한 광파이프 시스템의 채광성능 평가에 관한 연구)

  • Shin, Ju-Young;Hwang, Tae-Yon;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.25-33
    • /
    • 2010
  • Use of daylight in underground space interacts with physiological need for human beings and provides relief from feeling secluded. Light pipe system can deliver natural light into the space where it is needed and can be used as primary or a secondary light source with benefits of energy, productivity and health. To use light pipe system effectively under various conditions, it is important to investigate the effectiveness of light pipe system with reliable monitoring protocol. This paper presents the results of light pipe system performance used in underground parking lot under different sky conditions. Comparisons were made between the illuminance standards of underground parking lot and the monitored data. The results indicated that adequate illuminance level was shown until 4.5m distance from the light pipe under clear sky condition. However, additional lighting device showed be used under overcast sky to meet the proper illuminance level.

Investigation on the current lighting level at the gas stations and its improvement methods (주유소 조명 실태와 개선 방안)

  • 주윤석;이동호;임종국;여인선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.55-59
    • /
    • 1998
  • This paper investigates the illuminance level at the existing gas stations and compares the results with the KS and IESNA standards. The measured illuminance level in the pump island area is found to be high up to 3 times the recommended value in KS and somewhat lower than one in IESNA standard. From this results we conclude that significant degree of energy saving can be possible from proper maintenance program, and careful consideration must be paid in the design process. And the KS standard need to be examined more thoroughly against other nation's standards.