• 제목/요약/키워드: Profile bending

검색결과 167건 처리시간 0.027초

MIG-WELDING OF MAGNESIUM ALLOYS WITH PARTICULAR CONSIDERATION OF DROP DETACHMENT

  • Wohlfahrt, H.;Rethmeier, M.;Wiesner, S.
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.94-100
    • /
    • 2002
  • During the last years, great progress has been made in the fields of welding power sources and filler materials for the MIG-welding of magnesium alloys. This advice resulted in a better welding process, md, therefore, in highly improved welding results. Furthermore the gap between short-circuiting- and spray-arc-trunsfer could be closed by the triggered short-circuiting- and the short-circuiting-arc with pulse overlay. A crucial contribution to the welding process is the energy input into the filler material. Many problems result from the physical properties of magnesium, for instance its narrow interval between melting point 600$^{\circ}C$ and vaporization point 1100$^{\circ}C$. The energy input into the filler material has to be regulated in such a way that the wire will melt but not vaporize. For th is reason, special characteristics of power sources hue been examined and optimized with the help of high-speed-photographs of the welding process with particular consideration of the drop detachment. An important improvement of the weld seam profile has been achieved by using filler material of only 1.2 mm in diameter. The experiments hue been made with 2.5 mm thick extruded profiles of AZ31 and AZ6l. The results of tensile testing showed strength values of 80 to 100% of the base metal. B ending angles up to 60$^{\circ}$ have been reached. The fatigue strength under reversed bending of the examined magnesium alloys after welding reaches 50% of the strength of the base metal. When the seam reinforcement is ground of the fatigue strength can be raised up to 75% of the base metal.

  • PDF

높은 아치형 지중강판 구조물의 시공 중 거동 분석 (Behaviors of the High-profile Arch Soil-steel Structure During Construction)

  • 이종구;조성민;김경석;김명모
    • 한국지반공학회논문집
    • /
    • 제19권6호
    • /
    • pp.71-84
    • /
    • 2003
  • 지중강판 구조물은 강판부재 내에 발생하는 휨모멘트에는 매우 취약하기 때문에 그 주변을 양질의 흙으로 뒷채움하여 주변 흙과의 상호작용에 의하여 상부에 작용하는 하중을 지지한다. 그러나, 구조물 측면을 뒷채움할 때나 최소토피고를 확보하지 못한 상태에서 활하중이 작용할 때에는 강판부재내에 과도한 모멘트가 발생할 수 있다. 현재 설계기준에서는 허용변형량을 제시하여 시공 중에 과도한 변형이 발생하는 것을 방지하고 있으며 Duncan(1979)과 McGrath 등(2001)은 강도해석법을 제안하여 시공 중에 발생하는 모멘트를 강판의 소성강도 이내로 제한하고 있지만, 허용변형량은 경험적으로 규정한 값이고 강도해석에 의한 구조 안정성 검토는 유한요소 해석결과를 바탕으로 제안되었기 때문에 이들에 대하여 실험적 검증이 필요하다. 이 연구에서는 높은 아치형 구조물에 대한 실규모 현장시험을 실시하여 시공 중 거동과 활하중에 대한 하중지지 거동을 분석하였다. 시험결과를 바탕으로 시험시공 구조물의 허용변형량을 '높이의 1.45%' 로 추정할 수 있었는데 이는 설계기준의 허용값인 '높이의 2%' 보다 작은 값이었다. 또한, 계측결과를 Duncan과 McGrath 등이 제안한 강도해석결과와 비교하여 Duncan은 성토하중에 의한 모멘트는 과소평가하고 활하중 모멘트는 과대평가 하지만 McGrath 등은 두 값을 모두 실제와 근접하게 예측함을 알 수 있었다. 그러나, 두 방법에 의한 소성힌지에 대한 안전율은 실제 안전율과 잘 일치하여 두 방법 모두 시공 중에 작용하는 활하중에 대한 구조 안정성을 적절히 평가할 수 있음을 확인하였다.나 길항력(6.4 ㎜)은 남아있었다. 또한 분자량 10kDa 이하의 분획에서는 chitinase 활성은 없으나 길항력(5.2㎜)은 나타내었고, 80℃에서 열처리하여도 길항력(5.0mm)이 남아있어 효소 이외 다른 생리활성물질이 존재함을 확인하였다.rin, (+)-taxifolin 3-O--$\beta$-D-glucopyranoside, (+)-catechin 및 benzoic acid의 함량은 건조 및 처리 온도가 증가할 수록 감소하는 양상을 나타내었다.tier taste and the Doenjang with P. japonica Powder had the least sweet taste. In the flavor and overall Preference, the Doenjang with P. japonica powder was the lowestEX>로 측정되었고, 계사내 지붕의 표면 온도는 최고 $29^{\circ}C$가 측정되었다. 계사 내 표면 온도 및 닭의 표면 온도는 계사내 공기온도의 영향을 많이 받는 것으로 나타났다.ill in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times

광섬유 센서를 이용한 온도 및 변형 모니터링에 대한 현장응용 사례 (Case Studies on Distributed Temperature and Strain Sensing(DTSS) by using an Optical fiber)

  • 김중열;김유성;이성욱;민경주;박동수;방기성;김강식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.86-95
    • /
    • 2006
  • Brillouin backscatter is a type of reflection that occurs when light is shone into an optical fibre. Brillouin reflections are very sensitive to changes in the fibre arising from external effects, such as temperature, strain and pressure. We report here several case studies on the measurement of strain using Brillouin reflections. A mechanical bending test of an I beam, deployed with both fiber optic sensors and conventional strain gauge rosettes, was performed with the aim of evaluating: (1) the capability and technical limit of the DTSS technology for strain profile sensing; (2) the reliability of strain measurement using fiber optic sensor. The average values of strains obtained from both DTSS and strain gauges (corresponding to the deflection of I beam) showed a linear relationship and an excellent one-to-one match. A practical application of DTSS technology as an early warning system for land sliding or subsidence was examined through a field test at a hillside. Extremely strong, lightweight, rugged, survivable tight-buffered cables, designed for optimal strain transfer to the fibre, were used and clamped on the subsurface at a depth of about 50cm. It was proved that DTSS measurements could detect the exact position and the progress of strain changes induced by land sliding and subsidence. We also carried out the first ever distributed dynamic strain measurement (10Hz) on the Korean Train eXpress(KTX) railway track in Daejeon, Korea. The aim was to analyse the integrity of a section of track that had recently been repaired. The Sensornet DTSS was used to monitor this 85m section of track while a KTX train passed over. In the repaired section the strain increases to levels of 90 microstrain, whereas in the section of regular track the strain is in the region of 30-50 microstrain. The results were excellent since they demonstrate that the DTSS is able to measure small, dynamic changes in strain in rails during normal operating conditions. The current 10km range of the DTSS creates a potential to monitor the integrity of large lengths of track, and especially higher risk sections such as bridges, repaired track and areas at risk of subsidence.

  • PDF

국내산 침엽수 열압밀화재의 역학적 특성 (Mechanical Properties of Thermally Compressed Domestic Softwoods)

  • 황성욱;조범근;이원희
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권6호
    • /
    • pp.666-674
    • /
    • 2014
  • 국산 침엽수재의 용도확장을 위해 열압밀화를 실시하여 압축세트량에 따른 역학적 성능을 조사하였다. 열압밀화 공정에 의해 시험편의 밀도가 크게 향상되었다. 50% 압축 시 대조군 대비 잣나무재가 약 71%, 소나무재가 약 74%, 낙엽송재가 약 76%의 밀도가 증가되었으며, 압축세트량 증가와 함께 시험편의 재질이 균일해진다는 것을 내부밀도분포 분석을 통해 알 수 있었다. 열압밀화에 따른 역학적 성능의 변화는 대조군 대비 50% 압축 시 잣나무재의 경우, 종압축강도가 76%, 휨강도가 83%, 표면경도가 55% 증가하였다. 소나무재는 종압축강도가 69%, 휨강도가 130%, 표면경도가 76% 증가되었다. 낙엽송재의 경우 종압축강도가 77%, 휨강도가 120%, 표면경도가 44% 증가되었다. 국산 침엽수 열압밀화재의 강도성능은 일반적으로 낙엽송재가 가장 높고 잣나무재가 가장 낮았다. 그러나 열압밀화에 의한 강도성능의 증가율은 소나무재가 가장 높았다.

경질점성토 지반에서 Trench 굴착시 지하수위 변동에 따른 가설구조체 안정해석 기법 (Stability Analysis Techniques of Bracing Structure in the Hard Clay Ground According to the Variation of the Groundwater Level at the Trench Excavation)

  • 허창환;서성탁;김희덕;지홍기
    • 한국방재학회 논문집
    • /
    • 제3권2호
    • /
    • pp.99-110
    • /
    • 2003
  • 본 연구에서는 트랜치 굴착시 토석붕괴 방지시설에 대한 시공상의 안전성과 시공성 그리고 작업성에 주안점을 두어 재료의 경량화 및 구조체의 표준화를 시도하였다. 즉, 위험도 사전평가와 안전관리기법을 검토하고 흙막이 부재의 적용성과 흙막이 구조의 역학적 안정성을 검토하였으며, 이들 결과로부터 흙막이 구조체의 역학적 거동매카니즘 규명과 규격의 표준화를 위하여 경량흙막이 구조체의 구조안전성과 구조해석을 실시하였으며, 그 결과를 요약하면 다음과 같다. 1) 흙막이 구조의 역학적 타당성과 토질역학적 조건을 고려한 신소재 활용성을 확보하기 위하여 흙막이 부재의 역학적 성능과 부재에 작용하는 토압정수를 제시하였으며, 흙막이 구조체의 해석이론과 방법을 제시하였다. 2) 강화합성수지(FRP)를 사용한 경량판넬 부재의 지질구조가 경질점성토인 조건을 대상으로 구조해석 결과, 지하수위 조건에 따라서 판넬의 역학적(휨모멘트, 전단력, 축응력) 특성이 변화하고 있었으며, 역학적 해석결과가 허용응력 범위에 있음을 알 수 있어 이는 경량판넬이 트랜치 굴착시에 흙막이 구조로서 유용성을 알 수 있었다.

Half-Deck을 포함한 60 m 경간 PSC 거더의 단면 및 텐던 프로파일 최적화 연구 (A Study on the Optimum Cross-section and Tendon Profiles of 60 m span Half-Decked PSC Girder Bridge)

  • 김태민;김도학;김문겸;임윤묵
    • 대한토목학회논문집
    • /
    • 제31권6A호
    • /
    • pp.417-424
    • /
    • 2011
  • 본 연구에서는 60 m 급의 장경간 PSC 거더의 개발을 위하여 단면 개선부터 텐던 배치 형상까지 구조적인 성능뿐만 아니라 경제성과 시공성 등을 고려해가며 거더 개발에 관한 연구를 진행하였다. 단면 최적화를 통해 Bulb-T 형의 단면을 도출하였고 단면 평가를 통해 실제 설계 가능성을 평가하였다. 또한 텐던의 배치를 효율적으로 구성하여 사용하중에 대해 효과적으로 대처할 수 있도록 하였다. 실제 대상교량을 선정한 후 개발 거더를 적용해 유한요소해석을 수행한 결과, 모든 하중단계에서 설계 허용응력을 만족하였다. 또한 사용하중에 의해 발생하는 응력이 허용하중보다 작아 안전측 설계가 가능한 것으로 나타났다. 이를 바탕으로 실물 크기의 60 m 거더를 제작해 4점 실험을 실시한 결과 초기 균열이 사용하중의 2배 이상에서 발생하여, 실험 결과를 통해서도 충분한 구조적 성능을 입증하였다. 본 연구를 통해 개발된 Half-Decked PSC 형식의 60 m 거더는 단면개선과 효율적인 텐던 배치로 경간대비 매우 낮은 형고를 갖게 되었고, 구조적인 이점은 물론 경제성이나 시공성 등에서도 큰 장점을 가질 것으로 판단된다.

헬리컬기어의 동적해석을 통한 전달오차 예측 (Prediction of Transmission Error Using Dynamic Analysis of a Helical Gear)

  • 이정석;윤문영;부광석;김흥섭
    • 대한기계학회논문집A
    • /
    • 제40권12호
    • /
    • pp.1005-1011
    • /
    • 2016
  • 기어소음의 근본적인 원인은 전달오차로 인해 발생하게 된다. 전달오차는 기어가 맞물릴 때 발생하는데 크게 정적전달오차와 동적전달오차가 있다. 이러한 오차들은 기어 이빨의 처짐 또는 치면 마찰에 의해 발생하고 이 요인들이 원인이 되어 기어 시스템에 진동이 발생하게 된다. 그리고 이 진동이 기어의 축으로 이동하게 되어 축을 떠받치고 있는 베어링에 전달되고 베어링에 전달된 가진은 최종적으로 기어의 케이싱으로 이동하게 되어 소음을 방출하게 된다. 본 논문에서는 이러한 전달오차에 의해 발생하는 최대 굽힘응력을 가지는 롤각을 찾기 위한 응력해석을 수행되었다. 본 논문에서는 이론적 바탕으로 설계되어 인볼류트 곡선을 가진 기어와 수정된 치형을 가진 기어의 전달오차에 대한 해석을 진행하였다. 또한, 급작스러운 작동이나 큰 백래쉬로 인해 발생하는 충격강도에 대한 영향을 알아보기 위해 유한요소해석을 통해 각각 정적 최대굽힘응력과 동적 최대굽힘응력의 결과를 이용하여 충격인자 값을 예측해 보았다.