• Title/Summary/Keyword: Processed water

Search Result 670, Processing Time 0.028 seconds

Development of an Automated Measurement System for Dilution Process and Spraying Amount of Disinfectant

  • Kim, Jung-Chul;Chung, Sun-Ok;Cho, Byoung-Kwan;Chang, Hong-Hee;Kim, Suk;Chang, Dongil
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.228-239
    • /
    • 2013
  • Purpose: The objectives of this study were to develop an automated disinfectant dilution system, and an automated data management system for spraying amount for resolving uncertainty problem. Methods: Proper diluting rate was made by a controlled volume pump for liquid disinfectant and a screw conveyer pump for solid disinfectant. The water capacity of disinfecting system of 400 L was controlled by two water level sensors. The water quantity of water tank was controlled by the signals which were produced by the water level sensors. Signals were processed by Labview Programming, and ON/OFF of solenoid valve that was used for controlling water supplying to water tank, was controlled by SSR. The operating time of pumps for disinfectant was controlled quantitatively. A turbine flowmeter was used for development of automated measurement system for spraying amount of disinfectant. In order to save the flowmeter data and to control the spraying system, a multi-function data logger was used, and it was processed and saved in Excel file by a program developed in this study. Results: Labview 2010 was used for programming to control the automated measurement system for spraying amount of disinfectant. Results showed that the relationship between flowmeter value and time had a significant linear relationship such as 0.99 of $R^2$. Generally, 6.74 L/s of diluted disinfectant is sprayed for a vehicle passing through the disinfection system (about 15 seconds). Test results showed that average error between the measured spraying amount and the flowmeter data was 50 mL, and the range of error was 1.3%. Since the amount and time of spraying could be saved in real-time by using the spreadsheet files which could not be modified arbitrarily, it made possible to judge objectively whether the disinfection spraying was performed or not. Test results of spraying liquid and solid disinfectant showed that the errors between the measured discharge rate and the theoretical one were ranged within 3-4% for various dilution rates. Conclusions: The disinfection system developed would be working accurately. The automated spraying data base management system satisfied the purpose of this study. The automated dilution process system developed in this study could discharge liquid and solid disinfectant with accurate dilution rate, relatively.

Performance Evaluation of MF Membrane Filtration Pilot System Associated with Pre Coagulation-Sedimentation with Iron-Based Coagulant and Chlorination Treatment (철염계 응집제를 사용한 전응집침전, 전염소처리와 PVDF 재질의 정밀여과 막을 조합한 막 여과 정수처리시스템 평가에 관한 연구)

  • Lee, Sanghyup;Jang, Nakyong;Yoshimasa, Watanabe;Choi, Yongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.588-597
    • /
    • 2004
  • In this research, we investigated the variation of transmembrane pressure and permeate water quality with pre coagulation and sedimentation with iron based coagulant and chlorination of feed water for PVDF (polyvinylidene fluoride) based MF membrane filtration. NaCIO was fed to the membrane module with dosage of 0.5mg/L and maintained during filtration. To observe the effect of raw water, three types of raw and processed waters, including river surface water, coagulated water and coagulated-settled water, were applied. In case of river surface water, the transmembrane pressure increased drastically in 500 hours of operation. On the contrary, no significant increase in transmembrane pressure was observed for 1,200 hours of operation for coagulated water and coagulated-settled waters. The turbidity of permeate was lower than a detection limit of equipment for all raw waters. The removal efficiency of humic substances of coagulated water and coagulated-settled water was approximate ten times of that of surface river water. And, the removal efficiency of TOC and DOC was approximate two times of that of surface river water. From the results of plant operation, stable operation was maintained at $0.9m^3/m^2{\cdot}day$ filtration flux through the combination of pre-coagulation and pre-chlorination. However, the water quality of permeate was the best when pre-coagulation-sedimentation process was combined with pre-chlorination.

Production of Ramyon from Korean Cultured Wheat by Adding with Hot Water Extract Powder of Safflower Seed (홍화씨 열수 추출 분말을 이용한 우리 밀 라면의 제조)

  • Shim Ji-Youn;Hwang Eun-Hee;Lee Il-Hwan;Jang Hae-Soon
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.15 no.1
    • /
    • pp.78-90
    • /
    • 2005
  • The purpose of this study was to make ramyon from Korean cultured wheat by adding with hot water extract powder from safflower seed in order to add the value of it. The cooking quality, instrumental texture and sensory characteristics of ramyon were analyzed. The ramyons with 0.1%, 0.3%, 0.5%, and 0.7% of hot water extract powder(HEP) from safflower seed, control, and those with 3% and 5% of dried powder(DP) from safflower seed were compared. The yield of HEP was 7.8%. Lightness, redness, Max. weight, strength, hardness, adhesiveness, cohesiveness and springiness were measured. As the amounts of HEP and DP was increasing, ramyons smelled stronger and was getting harder and chewier, while became less transparent and had no difference in elasticity and adhesiveness. In overall acceptability, both control and ramyon with HEP had similar points. From three important factors, appearance, color and smell to make ramyon more acceptable, addition of 0.3~0.5% of hot water extract powder from safflower seed was found to be the best. However, further studies on smells are needed to make processed foodstuffs with safflower seed.

  • PDF

Hydrologic Cycle Simulation of Urban River for Rehabilitation of Water Environment (II) - Dorimcheon Basin - (물 환경 건전화를 위한 도시하천의 물 순환 모의 (II) - 도림천 유역 -)

  • Lee, Sang-Ho;Lee, Jung-Min
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.815-823
    • /
    • 2006
  • The hydrologic cycle in urban catchment has been changed due to the expansion of impervious area by rapid urban development. In this study, the SWMM 5 (Storm Water Management Model 5) model was used to simulate the hydrologic cycle of the Dorimcheon catchment which suffers from the distorted hydrologic cycle as a typical urban catchment. This study compare continuous simulation of urban runoff combining the channel and sewer system with that of channel only in the Dorimcheon catchment. Continuous simulations of urban runoff were performed for the upstream basin of Dorim bridge. The urban impervious regions were processed by the land use analysis from LANDSAT_TM images. It was performed from 1975 to 2000 for every five years. Surface, groundwater and wastewater runoffs were additionally included in the simulations one at a time. Such simulations made it possible to evaluate those components quantitatively. The result of continuous simulation of urban runoff combining the channel and sewer system is that peak flow and recession are well simulated. The analysis results of urbanization effect on runoff are as follows: the surface runoff in 2000 increases to 64% of the whole precipitation whereas the surface runoff in 1975 amounts to 46% of the precipitation; the groundwater runoff in 2000 amounts to 6% and shows 8% decrease during the period from 1975 to 2000.

Estimation of Tropospheric Water Vapor using GPS Observation (GPS를 이용한 대류권의 수증기량 추정에 관한 연구)

  • 송동섭;윤홍식;조재명
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.2
    • /
    • pp.215-222
    • /
    • 2002
  • As the GPS signals propagate from the GPS satellites to the receivers on the ground, they are delayed by the atmosphere. The tropospheric delay consists of two components. The hydrostatic (or "dry") component that is dependent on the dry air gasses in the atmosphere and accounts for approximately 90% of the delay. And the "wet" component that depends on the moisture content of the atmosphere and accounts for the remaining effect of the delay. The Zenith Hydrostatic Delay (ZHD) can be calculated from the local surface pressure. The Total Zenith Delay (TZD) will be estimated and the wet component extracted later. Integrated water Vapor (IWV) gives the total amount of water vapor that a signal from the zenith direction would encounter. Precipitable Water Vapor (PWV) is the IWV scaled by the density of water. The quality of this PWV has been verified by comparison with radiosonde data(at Osan). We processed data for JULY 2 and JULY 14, 1999 from four stations(Cheju, Kwangju, Suwon, Daegu). We found the coincidence between PWV of the estimations using GPS and PWV of pressing the radiosonde data. The average of the difference between PWV using GPS and PWV using radiosonde was 3.77 mm(Std. = $\pm$0.013 mm) and 2.70 mm(Std. = $\pm$0.0011 mm) at Suwon & Kwangju.

Environmental Modeling and Thermal Comfort in Buildings in Hot and Humid Tropical Climates

  • Muhammad Awaluddin Hamdy;Baharuddin Hamzah;Ria Wikantari;Rosady Mulyadi
    • Architectural research
    • /
    • v.25 no.4
    • /
    • pp.73-84
    • /
    • 2023
  • Indoor thermal conditions greatly affect the health and comfort of humans who occupy the space in it. The purpose of this research is to analyze the influence of water and vegetation elements as a microclimate modifier in buildings to obtain thermal comfort through the study of thermal environment models. This research covers two objects, namely public buildings and housing in Makassar City, South Sulawesi Prov-ince - Indonesia. Quantitative methods through field surveys and measurements based on thermal and personal variables. Data analysis based on ASHRAE 55 2020 standard. The data was processed with a parametric statistical approach and then simulated with the Computational Fluid Dynamics (CFD) simulation method to find a thermal prediction model. The model was made by increasing the ventilation area by 2.0 m2, adding 10% vegetation with shade plant characteristics, moving water features in the form of fountains and increasing the pool area by 15% to obtain PMV + 0.23, PPD + 8%, TSV-1 - +0, Ta_25.7℃, and relative humidity 63.5 - 66%. The evaluation shows that the operating temperature can analyze the visitor's comfort temperature range of >80% and comply with the ASHRAE 55-2020 standard. It is concluded that water elements and indoor vegetation can be microclimate modifiers in buildings to create desired comfort conditions and adaptive con-trols in buildings such as the arrangement of water elements and vegetation and ventilation systems to provide passive cooling effects in buildings.

Physico-chemial Properties of Pacific Whiting Surimi by Acid-Aided Processing

  • Park, Y.J.;Kim, B.J.;Lee, K.W.;Y.J. Cho;Park, J.W.
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2000.10a
    • /
    • pp.79-80
    • /
    • 2000
  • Conventional surimi processing from white flesh fish, such as Pacific whiting and Alaska Pollee utilizes only <25% of the body (Toyoda and others 1992; Park and others 1997). Conventional surimi is refined myofibrillar proteins processed by removing unnecessary foreign materials such as fat, pigment skin, and water soluble sarcoplasmic proteins. The acid-aided process demonstrated excellent gel forming ability for cod and mackerel with extremely higher yield (Hultin and Kelleher 1999). (omitted)

  • PDF

Optimization of Carbonated Cellulose Fiber-Cement Composites

  • Won, Jong-Pil;Bae, Dong-In
    • KCI Concrete Journal
    • /
    • v.12 no.1
    • /
    • pp.79-89
    • /
    • 2000
  • This research developed an accelerated curing processe for cellulose fiber reinforced cement composites using vigorous reaction between carbon dioxide and cement paste. A wet-processed cellulose fiber reinforced cement system was considered. Carbonation curing was used to complement conventional accelerated curing. The parametric study followed by optimization investigation indicated that the carbonation curing can enhance the productivity and energy efficiency of manufacturing cellulose fiber reinforced cement composites. This also adds environmental benefits to the technical and economical advantages of the technology.

  • PDF

Comparative Analysis of Water Absorption and Water Solubility of Alkasite-based Restorative Material

  • Myeong-Gwan Jih;Hye-Jin Cho;Eu-Jin Cha;Tae-Young Park
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.74-79
    • /
    • 2023
  • Purpose: Cention N (Ivoclar Vivadent) was a recently introduced alkasite-based restorative material that was expected to replace amalgam and glass ionomer cement. This material was an esthetic restoration with adequate mechanical strength and release of fluoride and calcium. The purpose of this study was to measure the water sorption and water solubility of Cention N and evaluate its long-term durability compared to other esthetic restorations (Resin-Modified Glass Ionomer cement [RMGIC], Giomer, Composite Resin). Materials and Methods: Twenty specimens each of Cention N (CN), Resin Modified-Glass Ionomer Cement (FJ), Giomer (BF), and Composite Resin (FZ) were made. After each specimen was completely dried in a desiccator for 24 hours using a vacuum pressure pump, the specimen was weighed (m1). After that, the specimen was immersed in distilled water at 37℃ for 7 days, stored in a drying oven, and weighed (m2). After drying completely for 24 hours in a desiccator, the specimen was weighed (m3) to calculate the water absorption and water solubility using Formulas 1 and 2. The measured values were statistically processed and analyzed using SPSS, and the significance level was set at 0.05. Result: When measuring water sorption, FJ (122.61 ㎍/mm3) showed significantly higher water sorption than CN (35.42 ㎍/mm3) (P<0.05). There was no significant difference between FZ (18.03 ㎍/mm3) and BF (14.76 ㎍/mm3) (P=0.930). When measuring water solubility, CN (6.65 ㎍/mm3) showed significantly higher water solubility than FJ (1.47 ㎍/mm3) (P<0.05). Conclusion: Cention N had lower water sorption than RMGIC, but higher water solubility, indicating that it is more vulnerable to moisture and has lessened long-term durability.

Determination of Polycyclic Aromatic Hydrocarbons in Processed Chestnut Products (밤가공품 중 polycyclic aromatic hydrocarbons 함량 분석)

  • Seo, Il-Won;Nam, He-Jung;Kim, Dong-Hyuk;Shin, Han-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.339-344
    • /
    • 2009
  • Concentrations of polycyclic aromatic hydrocarbon (PAH) in processed chestnut products were determined by HPLC/FLD. The methodology involved procedures of sonication with water, extraction with hexane, and clean-up on a Sep-pak florisil cartridge. The PAH limits of detection (LOD) and limits of quantitation (LOQ) ranged from 0.012 to 0.382 ${mu}g/kg$ and from 0.042 to 1.273 ${mu}g/kg$, respectively. The coefficients of variation for intra- and inter-day assays were 0.02-4.48% and 0.37-9.83%, respectively, and the accuracies were 81.95-125.44% and 79.89-116.53%, respectively. The overall recoveries for eight PAHs spiked into the processed chestnut products ranged from 87.83 to 100.56%. As a result, PAH contents were not detected in the processed chestnut products.