• Title/Summary/Keyword: Procedure time

Search Result 5,457, Processing Time 0.034 seconds

A Time-Domain Finite Element Formulation for Transient Dynamic Linear Elasticity (과도 선형 동탄성 문제의 시간영역 유한요소해석)

  • Sim, U-Jin;Lee, Seong-Hui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.4
    • /
    • pp.574-581
    • /
    • 2001
  • Transient linear elastodynamic problems are numerically analyzed in a time-domain by the Finite Element Method, for which the variational formulation based upon the equations of motion in convolution integral is newly derived. This formulation is implicit and does not include the time derivative terms so that the computation procedure is simple and less assumptions are required comparing to the conventional time-domain dynamic numerical algorithms, being able to get the improved numerical accuracy and stability. That formulation is expanded using the semi-discrete approximation to obtain the finite element equations. In the temporal approximation, the time axis is divided equally and constant and linear time variations are assumed in those intervals. It is found that unconditionally stable numerical results are obtained in case of the constant time variation. Some numerical examples are given to show the versatility of the presented formulation.

Clogging theory-based real time grouting management system applicable in soil conditions

  • Kwon, Young-Sam;Kim, Jinchun;Lee, In-Mo
    • Geomechanics and Engineering
    • /
    • v.16 no.2
    • /
    • pp.159-168
    • /
    • 2018
  • In this study, a real-time grouting management system based on the clogging theory was established to manage injection procedure in real time. This system is capable of estimating hydraulic permeability with the passage of time as the grout permeates through the ground, and therefore, capable of estimating real time injection distance and flow rate. By adopting the Controlled Injection Pressure (CoIP) model, it was feasible to predict the grout permeation status with the elapse of time by consecutively updating the hydraulic gradient and flow rate estimated from a clogging-induced alteration of pore volume. Moreover, a method to estimate the volume of the fractured gap according to the reduction in injection pressure was proposed. The validity of the proposed system was successfully established by comparing the estimated values with the measured field data.

Transient Linear Elastodynamic Analysis by the Finite Element Method (유한요소법을 이용한 과도 선형 동탄성 해석)

  • Hwang, Eun-Ha;Oh, Guen
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.3
    • /
    • pp.149-155
    • /
    • 2009
  • A new finite element equation is derived by applying quadratic and cubic time integration scheme to the variational formulation in time-integral for the analysis of the transient elastodynamic problems to increase the numerical accuracy and stability. Emphasis is focused on methodology for cubic time integration scheme procedure which are never presented before. In this semidiscrete approximations of the field variables, the time axis is divided equally and quadratic and cubic time variation is assumed in those intervals, and space is approximated by the usual finite element discretization technique. It is found that unconditionally stable numerical results are obtained in case of the cubic time variation. Some numerical examples are given to show the versatility of the presented formulation.

  • PDF

Automatic Work Time Evaluation Based on a Verification of Disassemblability and Assembly Configuration (분해도 및 조립형상 정보를 이용한 작업시간 산정에 관한 연구)

  • Shin, Chul Kyun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.33 no.3
    • /
    • pp.355-363
    • /
    • 2007
  • This paper presents a method of an automatic work time evaluation based on the verification of a disassemblability and assembly configuration. Even though a work time evaluation is an important field of concern for planning assembly lay-out, there are some limitations using cumbersome user query or approximated work time data without considering assembly condition. To overcome such restriction, this paper presents a method to mathematically verify assembly conditions based on the disassemblability, which is defined by the separability and stability cost. The separability cost represents a facility of the part disassembly operation, and the stability cost which represents a degree of the stability for the base assembly motion. Based upon the results, we propose a new approach of evaluating work time using neural networks. The proposed method provides an effective means of solving the work time evaluation problem and gives a design guidance of planning assembly lay-out in flexible manufacturing application. Example study is given to illustrate the concepts and procedure of the proposed schemes.

Efficacy of Cox Maze IV Procedure Using Argon-Based Cryoablation: A Comparative Study with $N_2O$-Based Cryoablation

  • Lee, Kyung-Hak;Min, Jooncheol;Kim, Kyung-Hwan;Hwang, Ho Young;Kim, Jun Sung
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.367-372
    • /
    • 2014
  • Background: We compared the mid-term results of the Cox maze IV procedure using argon-based cryoablation with a procedure using $N_2O$-based cryoablation. Methods: From May 2006 to June 2012, 138 patients (mean age, $58.2{\pm}11.0$ years) underwent the Cox maze IV procedure. Eighty-five patients underwent the maze procedure using an $N_2O$-based cryoprobe (group N), and 53 patients underwent the maze procedure using an argon-based cryoprobe (group A). Bipolar radiofrequency ablation was concomitantly used in 131 patients. The presence of atrial fibrillation immediately, 6 months, 1 year, and 2 years after surgery was compared. Results: Early mortality occurred in 6 patients (4.3%). There were no differences in early mortality or postoperative complications between the two groups. Nineteen of 115 patients (16.5%) remained in atrial fibrillation at postoperative 12 months (14 of 80 patients (17.5%) in group N and 5 of 35 patients (14.3%) in group A, p=0.669). There were no differences in the number of patients who remained in atrial fibrillation at any of the time periods except in the immediate postoperative period. A multivariable analysis revealed that the energy source of cryoablation was not associated with the presence of atrial fibrillation at 1 year (p=0.862) and that a fine F wave (<0.1 mV) was the only risk factor predicting the presence of atrial fibrillation at 1 year (p<0.001, odds ratio=20.287). Conclusion: The Cox maze IV procedure using an argon-based cryoprobe was safe and effective compared with the maze procedure using an $N_2O$-based cryoprobe in terms of operative outcomes and the restoration of sinus rhythm for up to 2 years after surgery.

Establishment of Elution and Concentration Procedure for Rapid and Sensitive Detection of Norovirus in Foods of Diverse Matrices (다양한 매트릭스가 혼합된 식품을 대상으로 노로바이러스 신속검출을 위한 탈리 및 농축방법 확립)

  • Ahn, Jaehyun;Kwon, Youngwoo;Lee, Jeong-Su;Choi, Weon Sang
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.150-158
    • /
    • 2015
  • This article reports the development of an effective test procedure for detection of norovirus (NoV) in foods of diverse matrices. In this study, target foods included fermented milk, soybean paste, powders made from uncooked grains and vegetables, sesame leaves preserved in soy sauce, pickled mooli, and mooli. Viral recovery varied depending on the food matrices or elution buffers tested. Buffers were compared to determine effective elution buffers from artificially virus-contaminated foods. The conventional test procedure for concentrating viruses from food (elution-polyethylene glycol(PEG) precipitation-chloroform-PEG precipitation) was modified to save time by eliminating one PEG precipitation step. The modified procedure (elution-chloroform-PEG precipitation) was able to concentrate viruses more effectively than the conventional procedure. It also removed RT-PCR inhibitors effectively. The modified procedure was applied to target food for genogroup II NoV detection. NoV RNA was detected at the initial inoculum levels 3.125-12.5 RT-PCR units per 10-25 g tested food. The use of this newly established procedure should facilitate detection of low levels of norovirus in diverse foods.

The Effect of Waiting Environment of Airline Service on Perceived Waiting Time and Service Quality (항공사 서비스 과정의 대기환경이 지각된 대기시간 및 서비스 결과품질에 미치는 영향에 관한 연구)

  • Lee, Ji-Young;Han, Hee-Eun;Choi, Seong-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.575-585
    • /
    • 2016
  • This study aimed to prove that the effect of waiting environment on perceived waiting time and service quality evaluation of airline service procedure. Survey was conducted by questionnaires that were distributed to international airlines passengers who arrived at the airport. Totally, 300 samples were circulated, and 231 samples among those were collected. According to the results, the suggested hypotheses were accepted except the regulation effect of waiting acceptability. Physical environment has positive effect on the airport and boarding gate, and human environment has more positive effect in-flight service procedure. Thus, variables are correlated among waiting environment, perceived waiting time, and service quality evaluation of airline service. Acceptability as moderating variable has no effect due to passenger's pre awareness of estimated arrival and departure travel time certainly. At the end of this study, the results of this research can be conjugable on the airline industry, however, some limitations should be discussed by further study directions.

Negative Pressure Wound Therapy Applied to a Meshed Split-Thickness Skin Graft

  • Lee, Dong-Hun;Kim, Yu-Jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.25 no.2
    • /
    • pp.29-36
    • /
    • 2016
  • Purpose: Skin grafting is used for the transfer of cutaneous tissue from one site of the body to another. To improve graft survival, close contact between the graft and the wound bed is essential for vessels to grow across the gap. Here, we introduce an easy and efficient dressing method to improve graft survival. Materials and Methods: A retrospective chart review was performed to identify patients who underwent split thickness skin graft and negative pressure wound therapy (NPWT) or conventional treatment between January 2007 and April 2015. Overall, 25 consecutive patients were included in the NPWT group and 49 were included in the conventional dressing group to compare the outcome of the procedure. The data were obtained from medical records, including age, sex, cause of the skin defect, size of graft, time for healing, wound preparation time, and complications. Results: Of the NPWT group, the average wound size was $147.04{\pm}146.74cm^2$ (range, $9{\sim}900cm^2$). With the exception of one patient, all wounds healed without the need for further procedure. The average duration of time required for the NPWT group, which was defined as removal of stitches (or staples) and no need for additional active dressing, was $6.4{\pm}1.97days$ (range, 5~15 days). The average time for the conventional dressing group was $10.78{\pm}2.38days$ (range, 5~15 days). Conclusion: NPWT can be used to cover regions in which wound healing does not occur fully or when neither tie-over nor compressive dressings are applicable. This treatment also reduced wound healing time and allowed earlier patient mobilization and hospital discharge.

Vacuum Test of Cavity with Liquid Nitrogen

  • Choi, Suk;Park, Gunn-Tae;Kim, Heetae
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.132-135
    • /
    • 2015
  • Schematic of RAON vacuum system is introduced. Vacuum test for superconducting cavity with liquid nitrogen is performed. Schematic plan for RAON vacuum system is introduced and vacuum control system for superconducting cavity test is constructed. Vacuum pressure of cavity is shown as a function of pumping time. The temperature of cavity is shown as a function of cooling time. Outgassing species from cavity is also detected. Detailed experimental procedure is presented to test the cavity vacuum with liquid nitrogen.

Design of Added Dampers for Retrofit of Asymmetric Nonlinear Structures (비대칭$\cdot$비탄성구조물의 지진거동 개선을 위한 감쇠기 설계)

  • 김진구;방성혁
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.335-340
    • /
    • 2002
  • In this study procedure for finding out additional viscous damping required to meet a performance target of an asymmetric nonlinear structure is developed based on the design concept of Pauly. The behavior of an asymmetric nonlinear structure after yielding is investigated. Finally the required amount of equivalent damping is obtained using the direct-displacement-based design method without carrying out time-consuming nonlinear dynamic time history analysis.

  • PDF