• Title/Summary/Keyword: Probe measurements

Search Result 399, Processing Time 0.024 seconds

Visualization and Flowfield Measurements of the Vortical Flow over a Double-Delta Wing

  • Sohn, Myong-Hwan;Jang, Young-IL
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.4 no.1
    • /
    • pp.63-74
    • /
    • 2003
  • The vortical flow of a 65-deg flat plate delta wing with a leading edge extension(LEX) was examined through off-surface visualization, 5-hole probe and hot-film measurements. The off-surface flow visualization technique used micro water droplets generated by a home-style ultrasonic humidifier and a laser beam sheet. The angles of attack ranged from 10 to 30 degrees, and the sideslip angles ranged from 0 to -15 degrees. The Reynolds number was $1.82{\times}10^5$ for the flow visualization, and $1.76{\times}10^6$ for the 5-hole probe and hot-film measurements. The comparison of the visualization photos and the flow field measurement showed that the two results were in a good agreement for the relative position and the structure of the wing and LEX vortices, even though the flow Reynolds numbers of the two results were much different. The wing vortex and the LEX vortex coil each other while maintaining a comparable strength and identity at zero sideslip. Neither a looping of the wing vortex around the strake vortex, nor the lopsided coiling of the stronger strake and the weaker wing vortices was observed. At non-zero sideslip, the downward movement of the LEX vortex when going downstream was enhanced on the windward side, and the downward and inboard movement of the LEX vortex when going downstream was suppressed on the leeward side. The counterclockwise coiling of the wing and LEX vortices was decreased significantly on the leeward side.

Numerical Study on the Characteristics of Thermal Plasmas Disturbed by Inserting a Langmuir Probe (랑뮤어 탐침에 의해 변형된 열플라즈마 특성에 관한 해석적 연구)

  • Lee, J.C.;Kim, Y.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.189-194
    • /
    • 2008
  • Measurements with a Langmuir probe, which are the most often used procedures of plasma diagnostics, can disturb plasma flows and change its characteristics quite a little because the probe should be inserted into thermal flowing plasmas. In this study, we calculated the characteristics of thermal plasmas with and without the probe into an atmospheric argon free-burning arc numerically, and investigated aerodynamic and thermal disturbances with temperature and axial velocity distributions. For the modelling of thermal plasmas, we have made two governing equations, which are on the thermal-flow and electromagnetic fields, coupled together with a commercial CFD package and user-coded subroutines. It was found that thermal disturbances happened to both sides of the probe, before and behind, seriously. Due to the aerodynamic disturbance, we could find that there were the stagnation point in front of the probe and the wake behind it. Therefore, aerodynamic and thermal disturbances caused by the probe insertion should be considered to increase the reliability of the probe diagnostics.

Thermal Diffusivity Measurement of Backfilling Materials for Horizontal Ground Heat Exchanger Using Dual-Probe Method (이중탐침법을 이용한 수평형 지중열교환기 뒤채움재의 열확산계수 측정)

  • Sohn, Byong-Hu;Choi, Hang-Seok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.2
    • /
    • pp.51-59
    • /
    • 2011
  • Storage and transfer heat in soils are governed by the soil thermal properties and these properties are therefore needed in many engineering applications, including horizontal ground heat exchanger for ground-coupled heat pumps. This paper presents the measured results of the thermal diffusivity of soils(silica, quartzite, limestone, sandstone, and masonry soils) used for the trench backfilling materials of the horizontal ground heat exchanger. To assess this thermal property, we (i) measure the soil thermal conductivities and volumetric heat capacities using dual-probe method and (ii) compare the estimates from the de Vries method of summing the heat capacities of the soil constituents. The results show that the thermal diffusivity tends to increase as dry soil begins to wet, but it approaches a constant value or even decreases as the soil continues to wet. Measurements made by using the dual-probe method agreed well with independent estimates obtained using the single-probe method.

Effects of Auxiliary Probe on Low Frequency Ground Impedance Measurement (저주파 접지임피던스 측정에 미치는 보조전극의 영향)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon;Moon, Hyun-Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.367-370
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the auxiliary probes on the measurements of the low frequency ground impedance with the fall-of-potential method are described iud the testing techniques to minimize the measuring errors are proposed. The fall-of-pot ential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the characteristics of ground impedance due to the location of the potential probe, ground impedances were measured in case that the distance of current probe was fixed at 50[m] and the distance of potential probe was located from 10[m] to 50[m]. Also, the potential robe was located at 30[$^{\circ}$], 40[$^{\circ}$], 60[$^{\circ}$], 90[$^{\circ}$], and 180[$^{\circ}$]. The results could be help to determine the location of potential probe when the ground impedance was measured at grounding system.

  • PDF

Development of On line Diagnosis System for Generator (발전기 운전중 종합 진단시스템 개발)

  • Lee, Young-Jun;Kong, Tae-Sik;Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.975-977
    • /
    • 2005
  • The generator on-line diagnosis system has been developed. This system monitor the insulation condition of stator winding by on-line measurements of partial discharge and the shorted-turn condition of rotor winding by on-line measurements of slot leakage flux. Sensor, such as SSC(Stator Slot Coupler) and flux probe are used for generator on-line diagnosis.

  • PDF

Three Dimensional Flow Structure under Rotating Stall in an Axial Flow Fan (주기적 선회실속이 발성하는 축류홴의 3차원 유동구조)

  • Kang, Chang Sik;Shin, You Hwan;Kim, Kwang Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.105-110
    • /
    • 2002
  • Experimental study was conducted to reveal the instability such as leakage flow and rotating stall in an axial flow fan. For this study, unsteady total pressure probe and multi-hole pressure probe were specially designed for measuring the flow field upstream and downstream of rotor. The measured pressure signal was analyzed by Single and Double Phase Locked Averaging Technique. From the result of total pressure fields at inlet and outlet of the rotor, the useful information on the structure of the stall cell in radial direction was provided. Also, detailed flow measurements were carried out with a specially designed high frequency multi-hole pressure probe, providing some insight to the leakage flow and their interation.

  • PDF

Measurement of Plasma Density Generated by a Semiconductor Bridge: Related Input Energy and Electrode Material

  • Kim, Jong-Dae;Jungling, K.C.
    • ETRI Journal
    • /
    • v.17 no.2
    • /
    • pp.11-19
    • /
    • 1995
  • The plasma densities generated from a semiconductor bridge (SCB) device employing a capacitor discharge firing set have been measured by a novel diagnostic technique employing a microwave resonator probe. The spatial resolution of the probe is comparable to the separation between the two wires of the transmission lines (${\approx}$3 mm). This method is superior to Langmuir probes in this application because Langmuir probe measurements are affected by sheath effects, small bridge area, and unknown fraction of multiple ions. Measured electron densities are related to the land material and input energy. Although electron densities in the plasma generated by aluminum or tungsten-land SCB devices show a general tendency to increase steadily with power, at the higher energies, the electron densities generated from tungsten-land SCB devices are found to remain constant.

  • PDF

Development of Optical Fiber Coupled Displacement Probe Sensor with a New Compensation Method (보상법을 적용한 광섬유 변위센서의 개발)

  • ;;;P. Sainsot;L. Flamand
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.27-32
    • /
    • 2002
  • The intensity modulated type (reflective method) optical fiber sensor is a well -known method and widely applied to the displacement measurements and other industrial purposes. This type sensor has the advantages of relatively cheap cost, small sensor size and easiness of operation. The sensitivity of the sensor is very dependent of several error terms; the variation in the intensity of the light source and the changes in the surface reflectivity of the object. An optical fiber coupled displacement probe with a new compensation method is presented in this paper. The proposed displacement sensor can measure the displacements of the target surface independent of surface reflectivity error that is caused by the materials and surface processing grade.

Experimental Analysis of Radiative Heat Interchange on Furnace Exit Plane of a Steam Boiler

  • Ahn, Kook-Young;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.239-247
    • /
    • 2001
  • Measured radiative heat fluxes on the furnace exit plane of a heavy duty power boiler of steam output 1650 T/h are discussed. A high-ash pulverized bituminous coal was used. Such measurements are necessary to improve heat fluxes inside a steam boiler furnace was manufactured. An extra small heat radiation sensor was placed in the water cooled head of the probe. The sensor had no direct contact with furnace gases and measured only the radiant energy. There was no exposure to convective heat transfer. With the radiometric probe, one can obtain a spherical indicatrix of radiation intensity as well as hemispherical radiative heat flux incident on any surface passing through a measuring point inside the furnace. Thus, the quantity of radiation energy, passing through the furnace exit plane, to the convective heating surfaces and the quantity of radiation energy going in the opposite direction were measured. A formula for relative radiative heat flux on the furnace exit plane has been proposed.

  • PDF