• 제목/요약/키워드: Probe measurements

검색결과 400건 처리시간 0.028초

연약지반의 강성도 측정을 위한 관입형 벤더 엘리먼트 프로브의 개발 및 적용 (Development and Application of Penetration-type Bender Elements Probe for Stiffness Measurements of Soft Soils)

  • 목영진;정재우;김학성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.119-126
    • /
    • 2008
  • Ground stiffness(shear wave velocity) is one of the key parameters in geotechnical earthquake engineering. An In-situ seismic technique has its own advantages and disadvantages over the others in stiffness measurements. By combining the crosshole and seismic cone techniques and utilizing favourable features of bender elements, a new hybrid probe has been developed in order to enhance data quality and easiness of testing. The basic structure of the probe, called "MudFork", is a fork composed of two blades, on each of which source and receiver bender elements were mounted respectively. To evaluate the disturbance caused by the penetration of the probe, shear wave velocity measurements were carried out in the Kaolinite slurry in the laboratory. Finally, the probe was penetrated in coastal mud near Incheon, Korea, using SPT(standard penetration test)rods pushed with a routine boring machine and shear wave velocity measurements were carried out. The results were verified with data from laboratory and cone testing. The performance of the probe turns out to be excellent in terms of data quality and testing convenience.

  • PDF

Development of an Infrared Two-color Probe for Particle Cloud Temperature Measurement

  • Alshaikh Mohammed, Mohammed Ali;Kim, Ki Seong
    • 한국분무공학회지
    • /
    • 제20권4호
    • /
    • pp.230-235
    • /
    • 2015
  • The demands for reliable particle cloud temperature measurement exist in many process industries and scientific researches. Particle cloud temperature measurements depend on radiation thermometry at two or more color bands. In this study, we developed a sensitive, fast response and compact online infrared two-color probe to measure the temperature of a particle cloud in a phase of two field flow (solid-gas). The probe employs a detector contained two InGaAs photodiodes with different spectral responses in the same optical path, which allowed a compact probe design. The probe was designed to suit temperature measurements in harsh environments with the advantage of durability. The developed two-color probe is capable of detecting particle cloud temperature as low as $300^{\circ}C$, under dynamic conditions.

Profile Measurements of Micro-aspheric Surfaces Using an Air-bearing Stylus with a Microprobe

  • Shibuya, Atsushi;Gao, Wei;Yoshikawa, Yasuo;Ju, Bing-Feng;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권2호
    • /
    • pp.26-31
    • /
    • 2007
  • A novel scanning probe measurement system was developed to enable precise profile measurements of microaspheric surfaces. An air-bearing stylus with a microprobe was used to perform the surface profile scanning. The new system worked in a contact mode and had the capability of measuring micro-aspheric surfaces with large tilt angles and complex profiles. Due to limitations resulting from the contact mode, such as possible damage caused by the contact force and lateral resolution restrictions from the curvature of the probe tip, several system improvements were implemented. An air bearing was used to suspend the shaft of the probe to reduce the contact force, enabling fine adjustments of the contact force by changing the air pressure. The movement of the shaft was measured by a linear encoder with a scale attached to the actual shaft to avoid Abbe errors. A $50-{\mu}m-diameter$ glass sphere was bonded to the tip of the probe to improve the lateral resolution of the system. The maximum contact force of the probe was 10 mN. The shaft was capable of holding the probe continuously if the contact force was less than 40 mN, and the resolution of the probe could be as high as 10 nm, The performance of the new scanning probe measurement system was verified by experimental data.

근접전계 측정을 위한 광대역 프로브의 특성에 대한 고찰 (The considerations of the characteristics of Broadband Probe for Near Field Measurements)

  • 문정익
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 춘계종합학술대회
    • /
    • pp.565-568
    • /
    • 2007
  • 본 논문에서는 안테나 근역장 측정의 광대역성을 위해 이중리지 도파관 프로브를 설계하고 제작한 결과를 보여주고 있다. 광대역 임피던스 정합을 위해 구형 도파관내에 테이퍼 리지와 도파관 천이기를 사용하였다. 본 프로브는 정재파비 3.0이하에서 약 123%(4.17:1)정도의 광대역 특성을 가지고 있으며 방사이득은 $5.7\sim14.3dBi$ 였다. 본 프로브의 성능은 측정을 통하여 검증하였으며 그 결과가 양호함을 알 수 있었다.

  • PDF

연약지반 강성측정을 위한 벤더 엘리먼트 프로브 (Penetration-type Bender Element Probe for Stiffness Measurements of Soft Soils)

  • 정재우;오상훈;김학성;목영진
    • 대한토목학회논문집
    • /
    • 제28권2C호
    • /
    • pp.125-131
    • /
    • 2008
  • 지반의 강성도 또는 전단파 속도는 지반의 내진 설계 및 해석에서 중요한 인자 중의 하나이다. 현장 강성도를 측정하기 위한 탄성파 기법은 서로 다른 그만의 장단점을 갖고 있다. 이 연구에서는 데이터의 질과 시험의 수월성을 증진시키기 위해 벤더 엘리먼트의 특성과, 탄성파 기법 중 크로스홀과 탄성파 콘의 장점을 조합하여 새로운 프로브를 개발하였다. 머드포오크(MudFork)로 명명한 이 프로브이 기본 구조는 두 개의 블레이드(blade)로 이루어진 포오크 형태이다. 두 블레이드에 발진자와 감지기 엘리먼트가 각각 장착되었다. 실내 카올리나이트 토조에서 이 프로브가 지반에 관입될 때 야기되는 교란도를 규명하였다. 이 프로브를 인천의 한 연약지반에 일반 시추기를 이용하여 SPT(standard penetration test) 롯드로 관입하고 깊이별 전단파를 계측하였다. 이 계측된 전단파를 실내 시험과 콘 관입시험의 데이터로 검증한 결과 이 프로브는 데이터의 질과 시험의 수월성면에서 탁월한 현장 전단파 계측 장비로 평가된다.

Unsteady Wet Steam Flow Measurements in a Low-Pressure Test Steam Turbine

  • Duan, Chongfei;Ishibashi, Koji;Senoo, Shigeki;Bosdas, Ilias;Mansour, Michel;Kalfas, Anestis I.;Abhari, Reza S.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.85-94
    • /
    • 2016
  • An experimental study is conducted for unsteady wet steam flow in a four-stage low-pressure test steam turbine. The measurements are carried out at outlets of the last two stages by using a newly developed fast response aerodynamic probe. This FRAP-HTH probe (Fast Response Aerodynamic Probe - High Temperature Heated) has a miniature high-power cartridge heater with an active control system to heat the probe tip, allowing it to be applied to wet steam measurements. The phase-locked average results obtained with a sampling frequency of 200 kHz clarify the flow characteristics, such as the blade wakes and secondary vortexes, downstream from the individual rotational blades in the wet steam environment.

생체내의 혈중이온농도 예측을 위한 마이크로 pH-ISFET프로브의 개발 (Development of a Micro pH-ISFET Probe for in vivo Measurements of the Ion Concentration in Blood)

  • 손병기;이종현;이광만
    • 대한전자공학회논문지
    • /
    • 제23권1호
    • /
    • pp.83-90
    • /
    • 1986
  • A micro pH-ISFET probe, which can be applied to the in vivo measurements of the hydrogen ion concentration in blood, has been developed, and a measuring system equiped with this probe also developed. The pH-ISFET has been fatricated by employing the techniques of integrated circuit fabrication. Two kinds of micro electrode formed around the sensing gate during the wafer process, and the other is a capillary type of Ag/AfCl/sat. KCI reduced in size. This capillary electrode has shown its good performance characteristics so far in the application with ISFET as well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and well as a commercial one. In order to form a micro pH-ISFET probe, this pH-ISFET and the capillary electrode were built together into a needle tip having 1 mm inner diameter. The chip size of a twin pH-ISFET is 0.8 mmx1.4 mm, the material of the sensing gate membrane is Si3N4, and the sensitivity of the developed probe is about 52mV/pH.

  • PDF

Reliability and validity of rehabilitative ultrasound images obtained using a hands-free fixed probe in measuring the muscle structures of the tibialis anterior and the gastrocnemius

  • Choi, Mun-Sang;Shin, Jang-Hoon;Park, Hye-Kang;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권4호
    • /
    • pp.194-201
    • /
    • 2019
  • Objective: This study aimed to investigate the reliability and validity of muscle thickness (MT) and pennation angle (PA) measurements of the ankle muscle, including the tibialis anterior (TA) and the medial gastrocnemius (MGCM), using a hands-free fixed probe and to compare it with the conventional linear probe. Design: Observational inter-rater reliability study. Methods: Thirty-three healthy subjects (20 male, 13 female) were included. In all subjects, ultrasound images were acquired from the TA and MGCM using a hands-free fixed probe and a conventional linear probe in random sequence by two examiners at two time-points within a 7-day interval. MT and PA were calculated on the taken images. Intra-class correlation coefficients (ICC), 95% confidence intervals, standard error of measurement and the Pearson's correlation coefficient were used to estimate reliability and validity. And also, Bland-Altman plots were generated for a visual representation of MT and PA at the TA and MGCM. Results: The ICC for all intra-rater reliability was 0.943 to 0.995 and that for all inter-rater reliability was 0.928 to 0.993, indicating excellent reliability. A significantly high correlation was observed between MT and PA at the TA and MGCM with use of the hands-free fixed probe and the conventional linear probe (r>0.938; p<0.001). Conclusions: The hands-free fixed probe provided excellent images for measurement of the MT and PA of the TA and MGCM and is a useful device for making clinical measurements of muscle structure without grasping of the probe.

SURFACE POTENTIAL DISTRIBUTION ON POLYMER INSULATORS

  • Kitani, Isamu
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제11권11호
    • /
    • pp.17-21
    • /
    • 1998
  • The surface potential distribution on insulating polymers was measured by scanning of the probe of an electrostatic voltmeter. The measurements were done for two measured by scanning of the probe of an electrostatis voltmeter. The measurements were done for two cases. In the first case, it was measured on the free surface of insulating films which had been inserted between plane electodes after the removal of the upper brass disk electrode. In the second case, we measured the charging region between a circular and its opposing concentric ring electrodes after the removal of dc ramp voltage in air and nitrogen gas.

  • PDF