• Title/Summary/Keyword: Probe Unit

Search Result 138, Processing Time 0.031 seconds

An experimental study for noise reduction of the cross-flow fan of the room air-conditioners (에어컨용 직교류홴의 저소음화를 위한 실험적 연구)

  • 구형모
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.871-879
    • /
    • 1999
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectrums of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared of the experimental rig with and without the bounding fence for various flow rates.

  • PDF

A Fabrication Method of Blade Type Tip for Probe Unit Device (프르브유닛 소자용 블레이드형 팁 제조방법)

  • Lee, Keun-Woo;Lee, Jae-Hong;Kim, Chang-Kyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1436-1440
    • /
    • 2007
  • Beryllium copper has been known to be an important material for the various fields of industry because it can be used for mechanical and electrical/electronic components that are subjected to elevated temperatures (up to $400^{\circ}C$ for short times). Blade type tip for probing the cells of liquid crystal display(LCD) was fabricated using beryllium copper foil. The dry film resist was employed as a mask for patterning of the blade type tip. The beryllium copper foil was etched using hydrochloric acidic iron-chloride solution. The concentration, temperature, and composition ratio of hydrochloric acidic iron-chloride solution affect the etching characteristics of beryllium copper foil. Nickel with the thickness of $3{\mu}m$ was electroplated on the patterned copper beryllium foil for enhancing its hardness, followed by electroplating gold for increasing its electrical conductivity. Finally, the dry film resist on the bridge was removed and half of the nickel was etched to complete the blade type tip.

Dopping Effect of Fluorine Atom on the Superconductivity of $YBa_2Cu_3O_{7-x}F_y$

  • Kim, Keu-Hong;Cho, Seun- Koo;Kim, Yoo-Young;Park, Jong-Sik;Choi, Mu-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.5
    • /
    • pp.460-463
    • /
    • 1990
  • The normal and fluorinated high-Tc superconducting materials, $YBa_2Cu_3O_{7-x}F_y$with $0.25{\leq}x{\leq}0.55\;and\;0.00{\leq}y{\leq}0.30$, were synthesized to investigate the dopping effect of fluorine atom on the superconductivity of Y123 and studied by X-ray diffraction analysis and electron probe microanalysis, resistivity and thermopower measurements, and polarized micro-Raman spectroscopy. The reproducible micro-Raman spectra were recorded and analyzed. The coherent assignments could be suggested for the spectra of normal and fluorinated samples. The fluorine atoms introduced were found to be substituted for oxygen in pyramidal Cu-O units rather than in Cu-O chains. The unit cell parameters were decreased upon the substitution of oxygen by fluorine atom. From the decreasing cell parameters and Tc, the increasing thermopower, and the possible assignments of the vibrational modes, it could be suggested that the dopping of fluorine atom localizes the superconducting electrons in Y123.

A Permeability Measurement of Small Unilamellar Vesicles by 6-Carboxyfluorescein$^*$

  • Lee, Choong-Hee;Choi, Myung-Un
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.4
    • /
    • pp.154-158
    • /
    • 1984
  • In order to characterize the permeability of small unilamellar vesicles (SUV), efflux of 6-carboxyfluorescein (6-CF) from the vesicles was monitored spectrophotofluorometrically. Since the entrapped highly quenched 6-CF (200 mM) became fluorescent upon release from the vesicles, the 6-CF could be used as an efflux probe. SUV containing entrapped 6-CF was prepared from egg phosphatidylcholine and separated by gel filtration on Sepharose 4B. Observed change of relative fluorescent intensity with time was sigmoidal. From this curve, the parameter of permeability was determined either by half-time or a released amount per unit time from the initial slope. Half-time of efflux of prepared SUV having 302 ng phospholipid/ml in 10 mM Tris-HCl buffer pH 7.4 was 21.0 min at $37{\circ}C$. Various factors which could affect the half-time were examined including temperature, pH, salt, and vesicle concentration. In particular the effect of vesicle concentration on the efflux revealed that the permeability can be a function of the concentration.

GAS KINEMATICS AND PHOTOIONIZATION IN TYPE 1 AGNs WITH STRONG OUTFLOWS

  • KIM, CHANGSEOK;WOO, JONG-HAK;LUO, RONGXIN
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.61.3-61.3
    • /
    • 2020
  • We present spatially resolved outflows and photoionization for a pilot sample of 11 type 1 AGNs (z<0.3) based on the Gemini Multi-Object Spectrograph Integral Field Unit data. These AGNs were selected since we found strong outflow signatures in SDSS spectra. We focus on [OIII] and Hα emission lines to probe outflow kinematics by measuring line flux, velocity, and velocity dispersion at each pixel. We investigate characteristics of gas kinematics of type 1 AGNs and compare them with those of type 2 AGNs in our previous studies. Furthermore, by drawing BPT map, photoionization states will be also discussed. Based on the results, we discuss various implications on the impacts of outflows on star formation in host galaxies.

  • PDF

Property of Composite Silicide from Nickel Cobalt Alloy (니켈 코발트 합금조성에 따른 복합실리사이드의 물성 연구)

  • Kim, Sang-Yeob;Song, Oh-Sung
    • Korean Journal of Materials Research
    • /
    • v.17 no.2
    • /
    • pp.73-80
    • /
    • 2007
  • For the sub-65 nm CMOS process, it is necessary to develop a new silicide material and an accompanying process that allows the silicide to maintain a low sheet resistance and to have an enhanced thermal stability, thus providing for a wider process window. In this study, we have evaluated the property and unit process compatibility of newly proposed composite silicides. We fabricated composite silicide layers on single crystal silicon from $10nm-Ni_{1-x}Co_x/single-crystalline-Si(100),\;10nm-Ni_{1-x}Co_x/poly-crystalline-\;Si(100)$ wafers (x=0.2, 0.5, and 0.8) with the purpose of mimicking the silicides on source and drain actives and gates. Both the film structures were prepared by thermal evaporation and silicidized by rapid thermal annealing (RTA) from $700^{\circ}C\;to\;1100^{\circ}C$ for 40 seconds. The sheet resistance, cross-sectional microstructure, surface composition, were investigated using a four-point probe, a field emission scanning probe microscope, a field ion beam, an X-ray diffractometer, and an Auger electron depth profi1ing spectroscopy, respectively. Finally, our newly proposed composite silicides had a stable resistance up to $1100^{\circ}C$ and maintained it below $20{\Omega}/Sg$., while the conventional NiSi was limited to $700^{\circ}C$. All our results imply that the composite silicide made from NiCo alloy films may be a possible candidate for 65 nm-CMOS devices.

Gene Expression in Zn-deficient U937 Cell Line : Using cDNA Microarray (아연결핍된 단핵구 U937 Cell Line에 있어서의 유전자 발현 탐색 : cDNA Microarray 기법 이용)

  • Beattie, John H.;Trayhurn, Paul
    • Journal of Nutrition and Health
    • /
    • v.35 no.10
    • /
    • pp.1053-1059
    • /
    • 2002
  • In post-genome period, the technique for identifying gene expression has been changed to high throughput screening. In the field of molecular nutrition, the need for this technique to clarify molecular function of the specific nutrient is essential. In this study, we have tested the zinc-regulated gene expression in zinc-deficient U937 cells, using cDNA microarray which is the cutting-edge technique to screen large numbers of gene expression simultaneously. The study result can be used for the preliminary gene screening data for clarifying, using monocyte U937 cell line, molecular Zn aspect in atherosclerosis. U937 cells were cultured in Zn-adequate (control, 12 $\mu$M Zn) or Zn-deficient (experimental, 0 $\mu$M Zn) ESMI media during 2 days, respectively. Cells were harvested and RNA was extracted. Total RNA was reverse-transcriptinized and synthesized cDNA probe labeled with Cy-3. fluorescent labeled cDNA probe was applied to microarray slide for hybridization slide, and after then, the slide was scanned using fluorescence scanner. ‘Highly expressed genes’ in Zn-deficient U937 cells, comparing to Zn-adequate group, are mainly about the genes for motility protein, immune system protein, oncogene and tumor suppressor and ‘Less highly expressed genes’ are about the genes for transcription, apoptosis associated protein, cell cycle, and several basic transcription factors. The results of this preliminary study imply the effectiveness of cDNA microarray for expression profiling of a singly nutrient deficiency, specially Zn. Furthur study, using tailored-cDNA array and capillary endothelial cell lines, would be beneficial to clarify molecular Zn function, more in detail.

MRI-Induced Full Thickness Burn on the Ear Lobule due to Pulse Oximetry: A Case Report (증례보고: MRI 검사시 귓불에 부착한 산소측정기로 인해 발생한 전층 화상)

  • Kim, BumSik;Lim, SooA;Yoon, JungSoo;Eo, SuRak;Han, Yea Sik
    • Journal of the Korean Burn Society
    • /
    • v.24 no.2
    • /
    • pp.43-45
    • /
    • 2021
  • Magnetic Resonance Image (MRI) has been used as a safe, conventional and harmless diagnostic tool. However, thermal injuries have frequently been reported during MRI scanning due to the heat generated by the reaction with the magnetic field. It is recommended that metal-containing monitoring devices such as pulse oximetry and ECG monitoring leads should be removed prior to the start of the MRI scan, but these monitoring devices are inevitably placed in children or patients in the intensive care unit who have low compliance with the scan. Since the interaction between the metal probe or wire loop of pulse oximetry and the magnetic field can result in high thermal conduction, full-thickness burn can occur over the entire body surface during the MRI examination. Several cases of thermal burns from pulse oximetry on the fingers have been reported. However, we present a case of a full-thickness burn arising left earlobe in a 2-month-old child caused by the high conduction heat from pulse oximetry metal probe.

Association of PINX1 but not TEP1 Polymorphisms with Progression to Hepatocellular Carcinoma in Thai Patients with Chronic Hepatitis B Virus Infection

  • Sriprapun, Methee;Chuaypen, Natthaya;Khlaiphuengsin, Apichaya;Pinjaroen, Nutcha;Payungporn, Sunchai;Tangkijvanich, Pisit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2019-2025
    • /
    • 2016
  • Hepatocellular carcinoma (HCC) is major health problem with high mortality rates, especially in patients with hepatitis B virus (HBV) infection. Telomerase function is one of common mechanisms affecting genome stability and cancer development. Recent studies demonstrated that genetic polymorphisms of telomerase associated genes such as telomerase associated protein 1 (TEP1) rs1713449 and PIN2/TERF1-interacting telomerase inhibitor 1 (PINX1) rs1469557 may be associated with risk of HCC and other cancers. In this study, 325 patients with HCC and 539 non-HCC groups [193 healthy controls, 80 patients with HBV-related liver cirrhosis (LC) and 266 patients with HBV-related chronic hepatitis (CH)] were enrolled to explore genetic polymorphisms of both SNPs using the allelic discrimination method based on MGB probe TaqMan real time PCR. We demonstrated that all genotypes of both genes were in Hardy-Wienberg equilibrium (P>0.05). Moreover, there was no significant association between rs1713449 genotypes and HCC risk, HCC progression and overall survival (P>0.05). Interestingly, we observed positive association of rs1469557 with risk of HCC when compared with the LC group under dominant (CC versus CT+TT, OR=1.89, 95% CI= 1.06-3.40, P=0.031) and allelic (C versus T alleles, OR=1.75, 95% CI=1.04-2.94, P=0.033) models, respectively. Moreover, overall survival of HCC patients with CC genotype of rs1469557 was significantly higher than non-CC genotype (Log-rank P=0.015). These findings suggest that PINX1 rs1469557 but not TEP1 rs1469557 might play a role in HCC progression in Thai patients with LC and be used as the prognosis marker to predict overall survival in HCC patients.

Design and manufacture of mini loop coil probe style magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 초미니 Loop-코일프로브 삽입형 자기치료기의 설계 및 제작)

  • Kim, Whi-Young;Choi, Jin-Young;Park, Sung-Jun;Kim, Hee-Je
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.2 no.1
    • /
    • pp.153-169
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF