• 제목/요약/키워드: ProGlide

검색결과 12건 처리시간 0.036초

Influence of a glide path on the dentinal crack formation of ProTaper Next system

  • Turker, Sevinc Aktemur;Uzunoglu, Emel
    • Restorative Dentistry and Endodontics
    • /
    • 제40권4호
    • /
    • pp.286-289
    • /
    • 2015
  • Objectives: The aim was to evaluate dentinal crack formation after root canal preparation with ProTaper Next system (PTN) with and without a glide path. Materials and Methods: Forty-five mesial roots of mandibular first molars were selected. Fifteen teeth were left unprepared and served as controls. The experimental groups consist of mesiobuccal and mesiolingual root canals of remaining 30 teeth, which were divided into 2 groups (n = 15): Group PG/PTN, glide path was created with ProGlider (PG) and then canals were shaped with PTN system; Group PTN, glide path was not prepared and canals were shaped with PTN system only. All roots were sectioned perpendicular to the long axis at 1, 2, 3, 4, 6, and 8 mm from the apex, and the sections were observed under a stereomicroscope. The presence/absence of cracks was recorded. Data were analyzed with chi-square tests with Yates correction. Results: There were no significant differences in crack formation between the PTN with and without glide path preparation. The incidence of cracks observed in PG/PTN and PTN groups was 17.8% and 28.9%, respectively. Conclusions: The creation of a glide path with ProGlider before ProTaper Next rotary system did not influence dentinal crack formation in root canals.

Control of Femoral Cannulation with a ProGlide Pre-Closure Device during Cardiac Surgery: Is It Reliable?

  • Kim, Chang Hun;Ju, Min Ho;Lim, Mi Hee;Lee, Chee-Hoon;Je, Hyung Gon
    • Journal of Chest Surgery
    • /
    • 제54권3호
    • /
    • pp.179-185
    • /
    • 2021
  • Background: The use of ProGlide as a percutaneous vascular closure device in cardiac surgery remains inconclusive. This study investigated the clinical outcomes of using ProGlide in the percutaneous cannulation of femoral vessels in adult cardiac surgery. Methods: From September 2017 to July 2018, 131 consecutive patients underwent femoral vessel cannulation during cardiac surgery. The ProGlide (Abbott Vascular Inc., Santa Clara, CA, USA) with percutaneous cannulation was used in 118 patients (mean age, 55.7±15.5 years). The accessibility of femoral cannulation was evaluated through preoperative computed tomography. For cannulation, sonography was routinely used. The postoperative ankle-brachial index (ABI) was used to evaluate femoral artery stenosis. Results: Of the 118 patients, 112 (94.9%) and 6 (5.1%) underwent minimally invasive cardiac surgery and median sternotomy, respectively. Most femoral cannulations were performed on the right side (98.3%) using 15F to 19F arterial cannulas. The technical success rate of cannulation with ProGlide was 99.2%, with no delayed bleeding or cannulation site-related complications during hospitalization. During follow-up, only 1 patient showed femoral artery stenosis with claudication and was treated with interventional balloon angioplasty. The postoperative ABI revealed no significant difference in functional stenosis between the cannulation and non-cannulation sides (n=86; cannulation vs. non-cannulation, 1.2±0.1 vs. 1.1±0). Conclusion: Percutaneous femoral cannulation with ProGlide was safe and feasible in adult cardiac surgery. This technique may be a good alternative option in patients requiring femoral vessel cannulation for cardiac surgery.

Glide path 형성용 니켈티타늄 회전 파일의 효율: in-vitro 예비 연구 (Efficiency of the nickel-titanium rotary instruments for glide path preparation: in-vitro preliminary study)

  • 김현철;곽상원;하정홍
    • 대한치과의사협회지
    • /
    • 제55권10호
    • /
    • pp.688-694
    • /
    • 2017
  • Objectives: This preliminary study compared the effects of glide path establishing instruments prior to substantial root canal preparation. Materials and Methods: Glide path was established by enlargement of the 2nd mesiobuccal root canal of Dentalike by using three kinds of glide path preparation nickel-titanium file; PathFile, One G and ProGlider. The pre- and post-instrumented Dentalikes were weighed in the resolution of 1 / 10mg. In addition, after glide path preparation, torque generated during shaping using the WavoOne file was measured. The data were analyzed by one-way ANOVA and Tukey post-hoc test at a significance level of 95%. Results: The ProGlider had the significantly larger amount of reduced weight than other instrument groups (p < 0.05). There was no significant difference between group of glide path preparation with ProGlider and without glide path preparation in maximum torque and total stress generation during the shaping with WaveOne. Conclusions: Glide path preparation instruments may have different efficiency according to their geometries. The Dentalike artificial teeth were revealed to have discrepancies in the size of root canals by microCT examination. It is impossible to make a meaningful judgment of the results due to the reliability or resolution problem of the root canal size of the artificial tooth selected as the standardized tooth.

  • PDF

Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals

  • Ha, Jung-Hong;Park, Sang-Shin
    • Restorative Dentistry and Endodontics
    • /
    • 제37권4호
    • /
    • pp.215-219
    • /
    • 2012
  • Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect ($2.796{\pm}0.134$) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium files

  • Uslu, Gulsah;Inan, Ugur
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.22.1-22.8
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the effect of glide path preparation with PathFile and ProGlider nickel-titanium (NiTi) files on the cyclic fatigue resistance of WaveOne NiTi files. Materials and Methods: Forty-four WaveOne Primary files were used and divided into four groups (n = 11). In the first group (0 WaveOne), the WaveOne Primary files served as a control group and were not used on acrylic blocks. In the 1 WaveOne Group, acrylic blocks were prepared using only WaveOne Primary files, and in the PF+WaveOne group and PG+WaveOne groups, acrylic blocks were first prepared with PathFile or ProGlider NiTi files, respectively, followed by the use of WaveOne Primary files. All the WaveOne Primary files were then subjected to cyclic fatigue testing. The number of cycles to failure was calculated and the data were statistically analyzed using one-way analysis of variance (ANOVA) and the Tukey honest significant difference multiple-comparison test at a 5% significance level. Results: The highest number of cycles to failure was found in the control group, and the lowest numbers were found in the 1 WaveOne group and the PF+WaveOne group. Significant differences were found among the 1 WaveOne, PF+WaveOne, and control groups (p < 0.05). No statistically significant differences were found between the PG+WaveOne group and the other three groups (p > 0.05). Conclusion: Glide path preparation with NiTi rotary files did not affect the cyclic fatigue resistance of WaveOne Primary files used on acrylic blocks.

Cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider, and the One G glide path instruments in double-curvature canals

  • Kirici, Damla;Kustarci, Alper
    • Restorative Dentistry and Endodontics
    • /
    • 제44권4호
    • /
    • pp.36.1-36.6
    • /
    • 2019
  • Objectives: The aim of this study was to compare the cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider and One G glide path instruments in artificial doublecurvature canals. Materials and Methods: This study included 15 WaveOne Gold Glider (size 15/0.08), 15 ProGlider (size 16/0.08), and 15 One G (size 16/0.06) nickel titanium files. The files were used in accordance with the manufacturer's instructions until they were broken in artificial double-curvature canals made of stainless steel. The time to fracture was recorded via a digital stopwatch and the number of rotations until fracture was also calculated. The data were statistically analyzed via the Kruskal-Wallis test. Results: The highest average number of rotations until fracture of the files was found for the WaveOne Gold Glider, followed by ProGlider and One G in order. Statistically significant differences were present between all groups of files (p < 0.05). Conclusions: In our study, the resistance of the WaveOne Gold Glider nickel-titanium (Ni-Ti) file to cyclic fatigue in S-shaped curved canals was found to be higher than that of the ProGlider and One G Ni-Ti files.

In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals

  • Yilmaz, Koray;Uslu, Gulsah;Ozyurek, Taha
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.282-289
    • /
    • 2017
  • Objectives: It was aimed to compare the cyclic fatigue resistances of ProGlider (PG), One G (OG), and HyFlex EDM (HEDM) nickel titanium glide path files in single- and double-curved artificial canals. Materials and Methods: 40 PG (16/0.02), 40 OG (14/0.03), and 40 HEDM (10/0.05) single-file glide path files were used in the present study. Sixty files were subjected to cyclic fatigue test by using double-curved canals and 60 files by using single-curved canal (n = 20). The number of cycles to fracture (NCF) was calculated and the length of the fractured fragment (FL) was determined by a digital micro-caliper. Twelve pieces of fractured files were examined with scanning electron microscope to determine fracture types of the files (n = 2). The NCF and the FL data were analyzed using one-way analysis of variance and post hoc Tukey test using SPSS 21 software (p < 0.05). Results: In all of the groups, NCF values were significantly lower in double-curved canals when compared to single-curved canals (p < 0.05). For both of single- and double-curved canals, NCF values of HEDM group in apical and coronal curvatures were found to be significantly higher than NCF values of PG and OG groups (p < 0.05). In both of single- and double-curved canals, NCF value of PG group was found significantly higher than OG group (p < 0.05). Conclusions: Within the limitations of this study, HEDM glide path files were found to have the highest cyclic fatigue resistance in both of single- and double-curved canals.

Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study

  • Dagna, Alberto;El Abed, Rashid;Hussain, Sameeha;Abu-Tahun, Ibrahim H;Visai, Livia;Bertoglio, Federico;Bosco, Floriana;Beltrami, Riccardo;Poggio, Claudio;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.316-323
    • /
    • 2017
  • Objectives: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Materials and Methods: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). Results: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. Conclusions: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.

Comparative analysis of torsional and cyclic fatigue resistance of ProGlider, WaveOne Gold Glider, and TruNatomy Glider in simulated curved canal

  • Pedro de Souza Dias;Augusto Shoji Kato;Carlos Eduardo da Silveira Bueno;Rodrigo Ricci Vivan;Marco Antonio Hungaro Duarte ;Pedro Henrique Souza Calefi ;Rina Andrea Pelegrine
    • Restorative Dentistry and Endodontics
    • /
    • 제48권1호
    • /
    • pp.4.1-4.10
    • /
    • 2023
  • Objectives: This study aimed to compare the torsional and cyclic fatigue resistance of ProGlider (PG), WaveOne Gold Glider (WGG), and TruNatomy Glider (TNG). Materials and Methods: A total of 15 instruments of each glide path system (n = 15) were used for each test. A custom-made device simulating an angle of 90° and a radius of 5 millimeters was used to assess cyclic fatigue resistance, with calculation of number of cycles to failure. Torsional fatigue resistance was assessed by maximum torque and angle of rotation. Fractured instruments were examined by scanning electron microscopy (SEM). Data were analyzed with Shapiro-Wilk and Kruskal-Wallis tests, and the significance level was set at 5%. Results: The WGG group showed greater cyclic fatigue resistance than the PG and TNG groups (p < 0.05). In the torsional fatigue test, the TNG group showed a higher angle of rotation, followed by the PG and WGG groups (p < 0.05). The TNG group was superior to the PG group in torsional resistance (p < 0.05). SEM analysis revealed ductile morphology, typical of the 2 fracture modes: cyclic fatigue and torsional fatigue. Conclusions: Reciprocating WGG instruments showed greater cyclic fatigue resistance, while TNG instruments were better in torsional fatigue resistance. The significance of these findings lies in the identification of the instruments' clinical applicability to guide the choice of the most appropriate instrument and enable the clinician to provide a more predictable glide path preparation.

Continuous rotary system과 single file system의 만곡 근관 형태 유지능에 대한 비교 연구 (Comparative Study on the Ability of Instruments to Maintain Original Canal Curvature of Continuous rotary System and Single File System)

  • 박상희;김덕중;송용범;이혜윤;김형선;이광원;유미경
    • 구강회복응용과학지
    • /
    • 제28권4호
    • /
    • pp.371-383
    • /
    • 2012
  • 성공적인 근관치료를 위하여 원래 근관 형태를 따르는 근관 성형 과정이 중요하다. 그러나 대부분의 근관은 만곡되어 있고, 근관 성형 기구는 직선의 금속을 기본으로 만들어지기 때문에 근관 성형 후 만곡 근관이 원래 근관 형태를 벗어나는 오류가 나타날 수 있다. 이런 오류들로 인하여 근관 치료가 실패할 수 있으므로 근관 성형시 원래 만곡형태를 유지할 수 있는 다양한 기술과 방법들이 소개되고 있다. 본 연구의 목적은 만곡 근관 형태의 레진 모형을 이용하여 기구의 형태와 사용방법이 다른 세 가지 Ni-Ti 파일을 사용하여 Ni-Ti 파일 종류에 따른 만곡 근관에 대한 성형 후 형태 유지능을 비교하는 것이다. 직경과 경사도가 ISO 15, 0.02인 30개의 레진모형을 사용하였다. 그룹 1은 Profile을 이용하여 #20/.06까지 근관 성형하였고, 그룹 2는 Mtwo를 이용하여 #35/.04까지 근관 성형하였으며, 그룹 3은 PathFile을 이용하여 glide path를 만들어준 다음 WaveOne 파일 중 Primary을 사용하여 근관 성형하였다. 기구 사용 전과 후의 레진모형을 스캔하여 디지털 이미지로 만들었다. 각 이미지를 중첩시킨 다음 Matlab r2010b 소프트웨어를 이용하여 곡률반경의 비(CRr)를 계산하였다. 이를 바탕으로 Ni-Ti file 간 성형 후 형태 유지능을 비교하기 위하여 1-way ANOVA를 이용하여 세 그룹의 CRr의 차이에 대한 유의성 검정을 시행하였다.(P<.05) 또한 continuous rotary system과 single file system간의 형태 유지능을 비교하기 위하여 independent t-test를 이용하였다.(P<.05) 곡률반경의 비(CRr)를 이용하여 Ni-Ti 파일 종류에 따른 만곡 근관의 형태 유지능을 비교한 결과 Ni-Ti file 간에는 통계적으로 유의한 차이가 있었다.(P<0.05) ProFile과 WaveOne은 Mtwo에 비해서 만곡 근관에서의 형태 유지능이 우수하게 나타났다.Ni-Ti 기구 사용 방법에 따른 만곡 근관 형태 유지능을 비교한 결과 continuous rotary system과 single file system 간에는 통계적으로 유의한 차이를 보이지 않았다.(P>0.05) 본 연구결과에 따르면, ProFile과 WaveOne은 Mtwo에 비하여 만곡 근관에서의 형태 유지능이 통계적으로 유의하게 높게 나타났으므로, ProFile과 WaveOne이 만곡근관에 대한 형태 유지능이 우수하다고 할 수 있다. 만곡근관에서의 형태 유지능에 있어서 continuous rotary system과 single file system은 만곡근관에서의 형태 유지능에 차이가 없다.