• Title/Summary/Keyword: Pro/Engineer

Search Result 74, Processing Time 0.019 seconds

Structural Analysis and Shape Optimization for Rotor of Turbomolecular Pump Using P-Method (P-기법을 이용한 터보분자펌프 로터의 구조해석 및 형상최적설계)

  • Won, Bo Reum;Jung, Hae Young;Han, Jeong Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.10
    • /
    • pp.1279-1289
    • /
    • 2013
  • In recent times, turbomolecular pumps (TMPs) have been used frequently to generate and maintain high and clean vacuum. Because of the high-speed rotation of the rotor, its structural safety should be treated as the first design concern. This paper presents the structural analysis and optimization of rotor blades of a TMP. To increase the numerical efficiency in the finite element modeling and analysis, the P-method provided in Pro/ENGINEER was used for simulation. The structural responses for several types of rotor blades were investigated, and the effects of the blade angle, blade length, and round size are thoroughly studied for each type of TMP blade. In addition, structural optimization to reduce and even the maximum stress at each stage of the TMP by changing the size of rounds between the blade and the hub was performed very successfully by using the P-method.

Development of The Bean Threshing System using Independent Driving (독립구동방식의 콩 탈곡기 시스템 개발)

  • Jang, BongChoon;Kim, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4124-4129
    • /
    • 2013
  • This purpose of this research is to build up a prototype of bean threshing machine after three dimensional design which can be driven independently by engine and hydraulic equipments and wheels. To accomplish the functionality of bean threshing machine the cutters are placed in a swirl type on a threshing drum the thresing capability would be improved. Also a exit pipe was designed to clear the remains to solve the past problems that the normal machines had. A fan was designed to blow to send the waste only to the outside. Only clean beans will be transferred through a blowing fan wind power to exit pipe and the system was designed to help the worker to collect the beans in front of the machine. This threshing machine using independent driving engine which can provide the power to drive the system and do the threshing is the first developed technology in domestic area through the University and Industry cooperation.

Activating Local Society Resource Network of Social Business : Focusing on Kwangju and Jejudo (사회적기업의 지역사회 자원연계 활성화를 위한 사례연구 -광주광역시·제주특별자치도를 중심으로-)

  • Choi, Hyuk-Ra;Kim, Seon-Myung;Kim, Gi-Hyeon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.1
    • /
    • pp.308-317
    • /
    • 2012
  • In this study, we searched for ways of the demand, the building up of strategic, collaborative networks plan activation of the local area network status by the current social enterprise and the direction of the future resources rinks, conducted by a case study of the (preliminary) social enterprise network-building activities based in Gwangju Metropolitan City and Jeju Special Self-Governing Province. By the study findings, local resources that the two regions social enterprise wants to connect are the most numerous in enterprise, public agencies and local media, followed by professionals' pro bo no, private organizations, volunteer groups. Hope for Information in conjunction is revealed in order by purchasing items, labor and financial support, public relations, purchasing service, marketing and a joint venture. For the conjunction, participating related events, the assistance of government agencies and related organizations joined, the role of chief engineer are emerged in order while they are performing work. By the findings, for the activation of local resources links of the social enterprises, it is necessary to impelled cooperation system between activating local profit companies, universities and one company ; a social enterprise and to uncovered volunteer activities of the community. Also, sparking, solidarity and building trust for social enterprises are derived as a ethical and alternative consumer movement.

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.