• Title/Summary/Keyword: Prism Lens

Search Result 82, Processing Time 0.027 seconds

A study on the effect of vision therapy after surgery for intermittent exotropia under 12 years of age (12세 미만 간헐성 외사시안의 수술 이후 시각훈련효과에 대한 임상연구)

  • Jang, Woo-Yeong;Lee, Seung-Wook
    • Journal of Korean Clinical Health Science
    • /
    • v.9 no.2
    • /
    • pp.1520-1525
    • /
    • 2021
  • Purpose. This study conducted visual function training for children under 12 years of age who relapsed after surgery for intermittent exotropia. We are trying to find out whether the visual function has been improved by visual function training. Methods. After surgery, the subject with recurrent exotropia was given a prescription for refractive error, followed by visual function training and vision therapy with visual sence using prisms and lenses. Results. The subjects' positive relative convergence improved to 19.69𝚫, corrected visual acuity improved to 0.88, and stereoscopic vision function improved to 53.08 arc second. It was found that the smaller the angle of deviation at the time of recurrence after surgery, the better the vision therapy effect. Conclusions. It can be seen that visual function training is helpful in improving visual function, and the importance of visual function training can be known.

Induced Prisms of Wearing Glasses Measured by Photographing (사진촬영으로 측정한 착용안경의 유발프리즘)

  • Shin, Hyung-Sup;Jang, Jun-Kyu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.527-532
    • /
    • 2014
  • Purpose: The matching of the optical center and the pupil center was measured by photographs in wearing glasses. In this study, the influences of the induced prism by the mismatching are studied. Methods: 74 subjects (148 eyes) who were spectacles wearer were participated in this study. The mean age was $29.19{\pm}12.22$ years (range 19-55 years). The facial photographs of subjects were taken while wearing spectacles. The matching of the corneal reflected image and optical center of the spectacle lens in the horizontal deviations, and the vertical deviations were measured by the observation of the photo image. The prisms induced in accordance with various frame type were calculated from the mismatching deviations. Results: The binocular horizontal deviations were $1.55{\pm}1.70mm$ for the metal frame, $1.71{\pm}2.21mm$ for the clings type plastic frame, and $1.15{\pm}1.38mm$ for the plastic frame. In the horizontal direction induced prism, the ratio over the tolerance was 23%. The ratio were the 17.6% at the BI prism, and 5.4% at the BO prism. The binocular vertical deviation comparisons were $3.93{\pm}1.91mm$ for the metal frame, $5.79{\pm}1.93mm$ for the clings type plastic frame, and 1$6.01{\pm}2.94mm$ for the plastic frame. In the vertical direction induced prism, the ratio over the tolerance was 44.6%. Based on the refraction power, the ratio were 12.2% at -0.25${\leq}-3.00$, and 32.4% at -3.00${\leq}-12.00D$. Conclusions: The induced prisms in the horizontal direction were much in the BI prism. The binocular vertical deviations of the glasses.

Effect of Overcorrection (-)Lens on Stereo-acuity and Angle of Deviation in Intermittent Exotropia (간헐외사시에서 과교정 (-)렌즈가 입체시 및 사시각에 미치는 영향)

  • Kim, Young Cheong;Park, Sang Woo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.305-311
    • /
    • 2013
  • Purpose: This study was conducted to evaluate the effect of prescription of overcorrection (-) lens, which is the one of the non-surgical treatments, on stereo-acuity and angle of deviation in intermittent exotropia. Methods: Twenty four children with intermittent exotropia were enrolled from October 2011 to December 2011. The angle of deviation(${\Delta}$), stereo-acuity (arcsec), monocular and binocular visual acuity (BVA, LogMAR), control of exodeviation and fusional ability using Worth 4 dot test were evaluated at near (33 cm) and far (6 m), under the overcorrecting (-)lens of -1.00, -.00, and -.00 D. Results: As a baseline finding, the angle of exodeviation was $20.9{\pm}9.7$ at near and $23.0{\pm}7.5$ at far. The angle of exodeviation at near decreased to $18.5{\pm}10.0$ (p<0.01), $15.8{\pm}9.0$ (p<0.01), $14.0{\pm}9.1$ (p<0.01) compared with baseline angle of exodeviation at near, as increasing diopters of (-) lens from -.00 D, -2.00 D and -.00 D, respectively. The angle of exodeviation at far also decreased to $21.4{\pm}5.2$ (p=0.01), $19.6{\pm}6.3$ (p<0.01) compared with baseline, as increasing minus lens from -2.00 D and -3.00 D, respectively. However, BVA, control of exodeviation, fusional ability and stereo-acuity showed no significant decrease despite of increasing diopters of (-)lens. Conclusions: The prescription of overcorrection (-)lens is an effective therapeutic method in intermittent exotropia which can reduce the near and far angle of exodeviation, and binocular visual acuity and stereo-acuity maintained without significant decrease despite of application of overcorrection (-)lens.

Design and Fabrication of an NIR Grism Si Optical Area Sensor Spectrometer with In-band Reference Wavelength (대역 내 기준 파장을 갖는 근적외선 그리즘 실리콘 광 면 센서 분광기 설계 및 제작)

  • Song, Jae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.28-34
    • /
    • 2017
  • An NIR grism Si optical area sensor spectrometer with in-band reference wavelength is designed and fabricated. It is composed of a transmission type diffraction grating (spatial density 300 line/mm), a rectangular N-BK7 prism (apex angle 30 degree), NIR filter(cutoff wavelength 720 nm), an imaging convex lens(focal length 50 mm F1.8) and an IR modified DSLR camera (Canon EOS40D) of Si optical area sensor ($3,888{\times}2,592$ pixels, pixel size $5.710{\mu}m$). "In-band reference wavelength function" is implemented using non-dispersive 0th diffraction order optical beam. The NIR grism spectrometer is tested in a laboratory using a halogen lamp and a Neon lamp. And the spectrometer is used in an astronomy field for obtaining the planet Jupiter NIR spectrum. In-band reference wavelength i.e. un-deviation wavelength is 846 nm, an wavelength resolution is 0.3027 nm/pixel, an wavelength resolving power is 2,794 and an wavelength range is 650~1,000 nm.

Study on the gate cutting of light guiding plate for mobile using quenching element (박형 도광판의 음각, 양각 마이크로 패턴 성형성에 관한 연구)

  • Hwang, Chul-Jin;Kim, Jong-Sun;Min, In-Gi;Kim, Jong-Dug;Yoon, Kyung-Hwan
    • Design & Manufacturing
    • /
    • v.2 no.5
    • /
    • pp.1-4
    • /
    • 2008
  • LCD-BLU (Liquid Crystal Display - Back Light Unit) is one of kernel parts of LCD unit and it consists of several optical sheets(such as prism, diffuser and protector sheets), LCP (Light Guide Plate), light source (CCFL or LED) and mold frame. The LGP of LCD-BLU is usually manufactured by forming numerous dots with $50-200{\mu}m$ in diameter on it by erosion method. But the surface of the erosion dots of LGP is very rough due to the characteristics of the erosion process during the mold fabrication, so that its light loss is high along with the dispersion of light into the surface. Accordingly, there is a limit in raising the luminance of LCD-BLU. Especially, the negative and positive micro-lens pattern fabricated by modified LiGA with thermal reflow process was applied to the optical design of LGP.

  • PDF

Optical Cap Sensor for Magneto-Optic Near-Field Recording (MO 근접장 기록을 위한 광학 갭 센서)

  • Yoon, Yong-Joong;Park, Jae-Hyuk;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.3
    • /
    • pp.245-250
    • /
    • 2004
  • This paper proposes a new method of measuring an air interface distance between a solid immersion lens(SIL) applied magneto-optic technology and the disk surface. For applying near-field recording (NFR) technology to the magneto-optic storage devices for the next generation, it is positively necessary to maintain the small air gap under about 100㎚. We design an apparatus that consists of some optical components such as a prism, a polarizer and an analyzer. By using the Fresnel reflection coefficient equation, Jones matrices calculation and Malus's law, we establish a mathematical model for understanding the characteristics of the system. The simulations are based on the mathematical model and through the simulation results which is made with various cases we can estimate the performance of the new optical gap sensor system. Experimental results, which are also based on the mathematical model for specific cases, are in good agreement with simulated ones and demonstrate the possibility as the new optical gap sensor.

The Developement of Secondary Optics Design Method for LED (LED 2차 광학 시스템의 설계법 개발)

  • Jung, Seung-Gyun;Seok, Dae-Il;Shin, Hwa-Young;Lee, Chang-Mo;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.26-32
    • /
    • 2007
  • Design methods of LED optic system includes point source assumption and imaginary focus approaches. However, these methods make significant error if the position of LED approachs that of optic system. This paper suggests a new design approach that LED is equally divided, light distribution of each division is predicted and confirmed through reverse tracing of light wave, and then each divided segment is separately designed, Using new design method, two kinds of example optic system were designed and light distribution and efficiency of the systems were evaluated.

Design of 2-axis compensation servo system for angle multiplexing Holographic Data Storage (각 다중화 방식의 홀로그래픽 정보저장기기의 양방향틸트 보상시스템 설계)

  • Lim, Sung-Yong;Kim, Nak-Yeong;Han, Cho-Lok;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2011
  • Holographic Data Storage System, one of the next generation data storage devices, is a 2-dimensional page oriented memory system using volume holograms in writing and retrieving process. Recently photopolymer with disc type substrate was selected as a media for the Holographic Data Storage System. The disc tilt occurs when the media rotates and the external disturbance applies. The disc tilt causes the change of the angle between the reference beam and the media, the data cannot be retrieved with the right angle or other data page is retrieved. The tilt is generated in a 2-axis direction (tangential, radial). The tangential tilt direction is the same with the multiplexing plane, while the radial tilt direction is a perpendicular to the multiplexing plane. In this research we propose 2-axis tilt angle servo system. The tilt errors are measured by using external photo detector and the additional red laser. Then the tangential direction tilt is compensated by using the galvano mirror. Also the radial direction tilt is compensated by the rotating prism between the relay lens in the reference field. Finally we confirm the compensation results through the Signal to Noise Ratio(SNR) and Bit Error Rate(BER).

Mechanism of Micro-V Grooving with Single Crystal Diamond Tool (단결정 다이어몬드 공구를 이용한 Micro-V 홈 가공기구)

  • Park D.S.;Seo T.I.;Kim J.K.;Seong E.J.;Han J.Y.;Lee E.S.;Cho M.W.;Choi D.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1223-1227
    • /
    • 2005
  • Fine microgroove is the key component to fabricate micro-grating, micro-grating lens and so on. Conventional groove fabrication methods such as etching and lithography have some problems in efficiency and surface integrity. This study deals with the creation of ultra-precision micro grooves using non-rotational diamond tool and CNC machining center. The shaping type machining method proposed in the study allows to produce V-shaped grooves of $40\mu{m}$ in depth with enough dimensional accuracy and surface. For the analysis of machining characteristics in micro V-grooving, three components of cutting forces and AE signal are measured and processed. Experimental results showed that large amplitude of cutting forces and AE appeared at the beginning of every cutting path, and cutting forces had a linear relation with the cross-sectional area of uncut chip thickness. From the results of this study, proposed micro V-grooving technique could be successfully applied to forming the precise optical parts like prism patterns on light guide panel of TFT-LCD.

  • PDF

Ultrasensitive laser interferometer for precision measurement of small vibration displacement (고감도 레이저 간섭계를 이용한 미소 진동 진폭의 정밀측정)

  • 서상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.440-449
    • /
    • 1988
  • Small vibration displacements may be measured by optical interferometers, based on the Michelson method. The standard Michelson interferometer works well when the mirror displacements are relatively large compared to the optical wavelength. But it does not work for displacements less than approximately a quater of optical wavelength. Several multiple reflection laser interferometers, simply modified standard Michelson interferometer, have been developed to decrease the minimum detectable limits. Among these a relatively simple and easy multiple reflection system is used to measure the small vibration displacements. This multiple reflection system is constructed with a right angle prism and a convex lens. Therefore this system makes it possible to measure a vibration displacement of the small area on the vibrating structure. The fringe interpolation method and curve fitting method are used to determine accurately the small vibration displacements from the measured interference fringe patterns. Also computer simulation technique is used to check the accuracies of these method. According to the results of the computer simulation technique, the curve fitting method is more accurate than the fringe interpolation method. The optically measured results are in good agreement with those of the standard accelerometer with high accuracy and it is possible to measure the peak vibration displacement as small as 9.01nm using multiple reflection system and curve fitting method.