• Title/Summary/Keyword: Priority pollutants

Search Result 95, Processing Time 0.021 seconds

Simultaneous Analysis of Semi-Volatile Organic Acid Priority Pollutants in Soil (토양 중의 비휘발성 산성 유기 Priority Pollutants 동시분석에 관한 연구)

  • Lee, Seung Seok;Park, Gyo Beom;Lee, Seong Geun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.3
    • /
    • pp.246-253
    • /
    • 1994
  • The simultaneous analysis of 11 semi-volatile organic acid compound which are listed as priority pollutants by EPA, were performed by GC/MS-SIM(selected ion monitoring). Two extraction procedures, sonication extraction and Soxhlet extraction, were studied as an extraction and concentration method for priority pollutants in soil. Accurecy and precision of the methods were measured by the calculation of mean recovery, mean relative standard deviation, and method detection limit. Finally, limitations and prospects were discussed.

  • PDF

Simultaneous Analysis of Pesticide Priority Pollutants in Soil (토양 중의 Pesticide Priority Pollutants 동시 분석에 관한 연구)

  • Lee, Seung-Seok;Park, Young-Joo;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.237-248
    • /
    • 1995
  • The simultaneous analysis of 16 organic pesticides, which are listed as a part of 129 priority pollutants by EPA(Environmental Protection Agency), was performed by GC-ECD(electron capture detector) and GC/MS-SIM(selected ion monitoring). Two extraction procedures from SW-846, sonication extraction and Soxhlet extraction, were somewhat modified and compared as an extraction and concentration method for the analysis of priority pollutants in soil. Accuracy and precision of the methods were reported from the calculation of mean recovery, mean relative standard deviation, and method detection limit.

  • PDF

Simultaneous Analysis of Semi-Volatile Organic Base/Neutral Priority Pollutants in Soil (토양 중의 비휘발성 염기/중성 유기 Priority Pollutants 동시 분석에 관한 연구)

  • Lee, Seung Seok;Park, Gyo Beom;Lee, Seok Geun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.6
    • /
    • pp.418-426
    • /
    • 1994
  • This study was aimed at the detection of 40 semi-volatile organic base/neutral compounds from soil among 129 priority pollutants listed by EPA. Two extraction procedures, sonication extraction and Soxhlet extraction, were studied as a extraction and concentration method for priority pollutants in soil. Extracts were analyted by GC/MS-SIM(selected ion monitoring). The analytical methods were tested by standard compounds spiked into blank soil. Accuracy and precision of the methods were measured by calculation of mean recovery and mean relative standard deviation. And the method detection limits were estimated.

  • PDF

Development of Korean Food-Chemical Ranking and Scoring System (Food-CRS-Korea) and Its Application to Prioritizing Food Toxic Chemicals Associated with Environmental Pollutants (환경유래 식품오염물질의 우선순위 선정 기법 (Food-CRS-Korea)의 개발과 적용)

  • Yang, Ji-Yeon;Jang, Ji-Young;Kim, Soo-Hwaun;Kim, Yoon-Kwan;Lee, Hyo-Min;Shin, Dong-Chun;Lim, Young-Wook
    • Environmental Analysis Health and Toxicology
    • /
    • v.25 no.1
    • /
    • pp.41-55
    • /
    • 2010
  • The aims of this study were to develop the suitable "system software" in chemical ranking and scoring (CRS) for the food hazardous chemicals associated with environmental emission and to suggest the priority lists of food contamination by environmental-origined pollutants. Study materials were selected with reference to the priority pollutants list for environment and food management from domestic and foreign research and the number of study materials is 103 pollutants (18 heavy metals, 10 PBTs, 10 EDs, and 65 organic compounds). The Food-CRS-Korea system consisted of the environmental fate model via multimedia, transfer environment to food model, and health risk assessment by contaminated food intake. We have established that health risks of excess cancer risks, hazard quotients (HQs) by chronic toxicity and HQs by reproductive toxicity convert to score, respectively. The creditable scoring system was designed to consider uncertainty of quantitative risk assessment based on VOI (Value-Of-Information). The predictability of the Food-CRS-Korea model was evaluated by comparing the presumable values and the measured ones of the environmental media and foodstuffs. The priority lists based on emissions with background-level-correction are 15 pollutants such as arsenic, cadmium, and etc. The priority lists based on environmental monitoring date are 17 pollutants including DEHP, TCDD, and so on. Consequently, we suggested the priority lists of 13 pollutants by considering the several emission and exposure scenarios. According to the Food-CRS-Korea system, arsenics, cadmium, chromes, DEHP, leads, and nickels have high health risk rates and reliable grades.

Evaluation of Environmental Toxicities for Priority Water Pollutants in a Small Watershed by Bioassays - Comparision between Lettuce Seed Germination Test and Microtox Bioassay - (생물학적 검정법을 이용한 소규모 수계내 수질 오염물질의 환경독성 평가 -상추씨 발아시험과 Microtox 시험 비교-)

  • 이지나;황인영
    • Environmental Analysis Health and Toxicology
    • /
    • v.14 no.4
    • /
    • pp.135-144
    • /
    • 1999
  • Environmental toxicities of priority water pollutants were evaluated by two selected bioassays, Lettuce seed germination/elongation test and Microtox acute toxicity test. Toxic chemicals (heavy metals, polycyclic aromatic hydrocarbons, and phenolic compounds) inhibited the germination rate and root elongation of Lettuce seed, as well as the bioluminescence of Microtox bacteria. When test biota were exposed to target chemicals, the sensitivity of Lettuce bioassay was relatively lower than that of Microtox bioassay. However, Lettuce bioassay may be a good candidate for prescreening the environmental toxicities of priority water pollutants, since the testing method with Lettuce seed was relatively easier and more economic than with Microtox bacteria. Toxicity tests were conducted to compare the validity and sensitivity of both bioassays for sediment from a small stream passed through urban area as well as leachate from a municipal solid waste landfill. From experimental results, we found that Lettuce test and Microtox test are compensated each other as a battery of bioassay for evaluating the environmental toxicities of field samples obtained from a small stream contaminated by pollutants.

  • PDF

Dynamic Range in the Simultaneous Analysis of Pesticide Priority Pollutants on Mass Spectrometer (질량분석기에서 Pesticide Priority Pollutants의 동시분석의 동적 범위)

  • Lee, Seung-Seok;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.320-324
    • /
    • 1996
  • The dynamic range of mass selected detector, which is very popular recently because of the simplicity and cheap price, was determined by using priority pollutants. The applied priority pollutants were four pesticides, 4,4'-DDE and 4,4'-DDD, which show the sharp peaks, and ${\alpha}$-endosulfan and ${\beta}$-endosulfan, which show the broad peaks in SIM Chromatogram. The dynamic range of the 4,4'-DDE and the 4,4'-DDD was $0.1{\sim}3000{\mu}g/ml$. The broad peaks of the ${\alpha}$-endosulfan and ${\beta}$-endosulfan resulted in $0.25{\sim}3000{\mu}g/ml$ of dynamic range.

  • PDF

Human Health Risk based Priority Ranking for Hazardous Air Pollutants (대기중 유해 화학 물질의 인체 위해도 우선순위 선정 연구)

  • Park Hoa-sung;Kim Ye-shin;Lee Dong-soo;Shin Dong-chun
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.1
    • /
    • pp.81-91
    • /
    • 2004
  • Although it is suggested that risk -based management plan is needed to manage air pollution effectively, we have no resources enough to evaluate all aspects of substances and set priorities. So we need to develop a logical and easy risk-based priority setting method. However, it if impossible that only one generic system that is consistent with all the use is developed. In this study, we proposed a human health risk based priority-setting method for hazardous air pollutants, and ranked priorities for this method. First of all, after investigating previous chemical ranking and scoring systems, we chose appropriate indicators and logics to goal of this study and made a chemical priority ranking method using these. As results, final scores in priority ranking method were derived for 25 substances, and ethylene oxide, acrylonitrile and vinyl chloride were included in high ranks. In addition, same substances were highly ranked when using default values like when using no default, but the scores of hydrofluoric acid and ryan and compounds were sensitive to default values. This study could be important that priorities were set including toxicity type and quality and local inherent exposure conditions and we can set area-specific management guidelines and survey plans as a screening tool.

Simultaneous Analysis of Pesticide Priority Pollutants in Water Samples (수질 시료 중의 Pesticide Priority Pollutants 동시분석에 관한 연구)

  • Kim Kye-Young;Kim Chong-Hyeak;Lee Sueg-Geun
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.590-598
    • /
    • 1993
  • The simultaneous analysis of samples, 16 organic pesticides in water among 129 priority pollutants listed by EPA, was performed by GC-ECD (electron capture detector) and GC/MS-SIM (selected ion monitoring). Two extraction procedures, liquid-liquid extraction (LLE) and solid-phase extraction (SPE), were studied as an extraction and concentration method. Accuracy and precision of the methods were measured by the calculation of mean recovery and mean relative standard deviation. Finally, the detection limits, the experimental limitations, and prospects were discussed.

  • PDF

Matrix effect on the Determination of Inorganic Priority Pollutants in Sludges (오니 시료중의 무기 Priority Pollutants의 분석 과정에 미치는 매질의 영향)

  • Lee, Huk-Hee;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.297-304
    • /
    • 1998
  • The three analysis methods, EPA method 3050, the method offered by Ministry of Environment in Korea, and modified method corrected in this laboratory, were studied to investigate the effect of matrix on the analysis of inorganic priority pollutants. 7 inorganic priority pollutants(Ni, Cr, Cu, Zn, Pb, Cd, Hg) were spiked to the plating, leather, paper, electric, and dye sludges. Mean recovery of the elements except Hg was 95.5% when the procedure of EPA method was applied. However, recovery by the two other extraction methods showed 11.1% and 27.7%, respectively. Digestions were done by MDS (microwave digestion system) and $HNO_3+HClO_4$ methods. To study organic and inorganic matrix effect, samples were made by adding triethanol amine as a organic matrix and $FeCl_3{\cdot}6H_2O$+$AlCl_3{\cdot}6H_2O$ as a inorganic matrix, respectively. The extracts were analyzed by AAS and HG-AAS. Mean recovery of the elements by the $HNO_3+HClO_4$ procedure, except Hg, gave better result than that of the MDS method. Mean recovery of elements was decreased when organic and inorganic matrices were added in the sludge samples. The procedure of MDS and $HNO_3+HClO_4$ digestion gave higher recoveries than that of direct analysis. In general, the results of the studies showed a significant matrix effect on the inorganic priority pollutants analysis in sludges.

  • PDF