• Title/Summary/Keyword: Printing Type

Search Result 508, Processing Time 0.024 seconds

Structure Analysis and Scale Model Test for Strength Performance Evaluation of Submersible Mooring Pulley Installed on Floating Offshore Wind Turbine (부유식 해상풍력발전기용 반잠수식 계류 풀리의 강도 성능평가를 위한 구조해석과 축소 모형시험)

  • Chang-Yong Song
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.5
    • /
    • pp.479-487
    • /
    • 2023
  • Recently, the destructive power of typhoons is continuously increasing owing to global warming. In a situation where the installation of floating wind turbines is increasing worldwide, concerns about the huge loss and collapse of floating offshore wind turbines owing to strong typhoons are deepening. A new type of disconnectable mooring system must be developed for the safe operation of floating offshore wind turbines. A new submersible mooring pulley considered in this study is devised to more easily attach or detach the floating of shore wind turbine with mooring lines compared with other disconnectable mooring apparatuses. To investigate the structural safety of the initial design of submersible mooring pulley that can be applied to an 8MW-class floating type offshore wind turbine, scale-down structural models were developed using a 3-D printer and structural tests were performed on the models. For the structural tests of the scale-down models, tensile specimens of acrylonitrile butadiene styrene material that was used in the 3-D printing were prepared, and the material properties were evaluated by conducting the tensile tests. The finite element analysis (FEA) of submersible mooring pulley was performed by applying the material properties obtained from the tensile tests and the same load and boundary conditions as in the scale-down model structural tests. Through the FEA, the structural weak parts on the submersible mooring pulley were reviewed. The structural model tests were conducted considering the main load conditions of submersible mooring pulley, and the FEA and test results were compared for the locations that exceeded the maximum tensile stress of the material. The results of the FEA and structural model tests indicated that the connection structure of the body and the wheel was weak in operating conditions and that of the body and the chain stopper was weak in mooring conditions. The results of this study enabled to experimentally verify the structural safety of the initial design of submersible mooring pulley. The study results can be usefully used to improve the structural strength of submersible mooring pulley in a detailed design stage.

Evaluation of Work Environment, Health Care Management and Exposure to Chemicals in the Workplaces Using Dimethylformamide (DMF) (디메틸포름아미드 취급 사업장의 작업환경 및 보건관리 실태와 노출요인 조사)

  • Hur, Soo-Jong;Suh, Chun-Hui;Lee, Chae-Kwan;Kim, Jeong-Ho;Kim, Dae-Hwan;Son, Byung-Chul;Lee, Chang-Hee;Chang, Goo-Rak;Lee, Jong-Tae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.225-235
    • /
    • 2010
  • This study was aimed to assess the status of working environment, health care management status and cause of exposure in manufactories using dimethylformamide (DMF). For the purpose, airborne concentration of DMF in the workplaces and N-methylformamide (NMF) in worker's urine were measured with job type and process. In addition, management of local exhaust ventilation system (LEV) and personal protective equipment (PPE) was evaluated at 35 work places (107 workers) located in Busan and Gimhae area. Mean DMF concentrations in work places by job type and process were of high level measured in printing and record media reproduction (5.23 ppm) and flaking process (2.48 ppm). Workers in adhesive job were measured a large amount of urine NMF (21.59 mg/${\ell}$). 98.1% of DMF handling workers were provided respirators, but 67.3% of those workers used them. The main reasons for not using respirators were inconvenience and difficulty of breathing. Airborne concentrations of DMF were higher in the workplaces in which LEVs were working abnormally, but there was not statistically significant. In addition, the urine NMF levels were correlated with management of LEV within the workers who did not use the respirators (p<0.048). These results implied that LEV should be installed and maintained properly to protect the workers from the exposure to DMF. Management of PPE should be also necessary to protect the workers from chemical hazards.

High Performance Flexible Inorganic Electronic Systems

  • Park, Gwi-Il;Lee, Geon-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.115-116
    • /
    • 2012
  • The demand for flexible electronic systems such as wearable computers, E-paper, and flexible displays has increased due to their advantages of excellent portability, conformal contact with curved surfaces, light weight, and human friendly interfaces over present rigid electronic systems. This seminar introduces three recent progresses that can extend the application of high performance flexible inorganic electronics. The first part of this seminar will introduce a RRAM with a one transistor-one memristor (1T-1M) arrays on flexible substrates. Flexible memory is an essential part of electronics for data processing, storage, and radio frequency (RF) communication and thus a key element to realize such flexible electronic systems. Although several emerging memory technologies, including resistive switching memory, have been proposed, the cell-to-cell interference issue has to be overcome for flexible and high performance nonvolatile memory applications. The cell-to-cell interference between neighbouring memory cells occurs due to leakage current paths through adjacent low resistance state cells and induces not only unnecessary power consumption but also a misreading problem, a fatal obstacle in memory operation. To fabricate a fully functional flexible memory and prevent these unwanted effects, we integrated high performance flexible single crystal silicon transistors with an amorphous titanium oxide (a-TiO2) based memristor to control the logic state of memory. The $8{\times}8$ NOR type 1T-1M RRAM demonstrated the first random access memory operation on flexible substrates by controlling each memory unit cell independently. The second part of the seminar will discuss the flexible GaN LED on LCP substrates for implantable biosensor. Inorganic III-V light emitting diodes (LEDs) have superior characteristics, such as long-term stability, high efficiency, and strong brightness compared to conventional incandescent lamps and OLED. However, due to the brittle property of bulk inorganic semiconductor materials, III-V LED limits its applications in the field of high performance flexible electronics. This seminar introduces the first flexible and implantable GaN LED on plastic substrates that is transferred from bulk GaN on Si substrates. The superb properties of the flexible GaN thin film in terms of its wide band gap and high efficiency enable the dramatic extension of not only consumer electronic applications but also the biosensing scale. The flexible white LEDs are demonstrated for the feasibility of using a white light source for future flexible BLU devices. Finally a water-resist and a biocompatible PTFE-coated flexible LED biosensor can detect PSA at a detection limit of 1 ng/mL. These results show that the nitride-based flexible LED can be used as the future flexible display technology and a type of implantable LED biosensor for a therapy tool. The final part of this seminar will introduce a highly efficient and printable BaTiO3 thin film nanogenerator on plastic substrates. Energy harvesting technologies converting external biomechanical energy sources (such as heart beat, blood flow, muscle stretching and animal movements) into electrical energy is recently a highly demanding issue in the materials science community. Herein, we describe procedure suitable for generating and printing a lead-free microstructured BaTiO3 thin film nanogenerator on plastic substrates to overcome limitations appeared in conventional flexible ferroelectric devices. Flexible BaTiO3 thin film nanogenerator was fabricated and the piezoelectric properties and mechanically stability of ferroelectric devices were characterized. From the results, we demonstrate the highly efficient and stable performance of BaTiO3 thin film nanogenerator.

  • PDF

Fabrication of Small SOFC Stack Based on Anode-Supported Unit Cells and Its Power Generating Characteristics (음극지지형 단전지를 사용한 소형 SOFC 스택의 제조 및 출력특성)

  • Jung, Hwa-Young;Kim, Woo-Sik;Choi, Sun-Hee;Kim, Joosun;Lee, Hae-Weon;Ko, Haengjin;Lee, Ki-Chun;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.10 s.269
    • /
    • pp.777-782
    • /
    • 2004
  • In this research, $5\times5cm^2$ unit cells were fabricated via liquid condensation process and uniaxial pressing followed by the screen printing of electrolyte and cathode layer. The SOFC stack was assembled with unit cells, gasket-type sealant and metal interconnect. The stack was designed to have a single column with internal-manifold and cross-flow type gas-channels. The SOFC stack produced 15 W, which is $50\%$ of the maximum power being expected from the maximum power density of the unit cell. Controlling factors for the proper operation of the SOFC stack and other designing factors of stack manifold and gas channels were discussed.

A Design Suggestion of Fairy Tales for the Silver Applying to the Service Design (서비스디자인을 적용한 실버대상 동화책의 디자인적 제안)

  • Li, Shu;Oh, Chi-Guy
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.9
    • /
    • pp.491-501
    • /
    • 2016
  • As the population of silver generation is increased, there are emerged the aging society and the silver industry as social issues. Previous studies in the fields of library & information science, education, the industrial art science suggested the need for fairy tale books for the silver generation, and from the design perspective, the characteristics of fairy tale books for the silver generation were analyzed. A fairy tale book is not only a medium delivering some information, but also a platform that a writer provides services to readers. Therefore, the purpose of this study aimed to suggest the importance of sensual experience on the design of fairy book for the silver generation, and to analyze such kind of fairy book's format, grid, typography, type, edition structure, image, layout, cover, paper, printing and production on the basis of five senses. According to the findings of this study, it was found that fairy tale books for the silver generation had different characteristics(type, picture, color, paper, etc.) from those for children, and it would be desirable to make designs for fairy tale books for the silver generation under the silver generation's esthetics standards with considering the silver generation's physiological, psychological factors. It is expected that this study would become a good foundation for more intensive researches for fairy tale books for the silver generation in future and would also be theoretically helpful in developing fairy tale books for the silver generation in future.

Development of electrochemical biosensor for determination of galactose (4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발)

  • Park, Kap Soo;Cho, Soon Sam;Quan, De;Lee, Jae Seon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.393-399
    • /
    • 2007
  • In principle, the blood galactose level may be determined conveniently with a strip-type biosensor similar to that for glucose. In this study, we describe the development of a disposable galactose biosensor strip for point-of-care testing. The sensor strip is constructed with screen-printed carbon paste electrode (SPCE) and sample amount (< $100{\mu}L$). The developed strip the galactose level in less than 90 s using bienzymatic system of galactose oxidase (GAO) and horseradish peroxidase (HRP). The effects of pH, mediator (1,1-ferrocenedimethanol) concentration, ratio of enzymes, and applied potential were determined preliminarily with glassy carbon electrodes, and optimized further with the strip-type electrodes. The sensor exhibits linear response in the range of $0{\sim}400{\mu}M$ ($r^2$ = 0.997, S/N = 3). Since a low working potential, in principle, the fabricated disposable galactose biosensor has -100 mV (vs. Ag/AgCl), it is applied for the detection of galactose, interfering responses from common interferents such as ascorbic acid, uric acid and acetaminophen could be minimized. The sensor has been used to determine the total galactose level in standard samples with satisfactory reproducibility (CV = 5 %).

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Opportunity Capturing Strategy of Venture Company in the Context of Dominant Design Competition: focused on compare with hardware and software industry (지배적 디자인 경쟁 환경에서 벤처기업의 업종별 기회포착 전략에 관한 연구: 하드웨어와 소프트웨어 산업 비교를 중심으로)

  • Moon, Ji-Yong;Ko, Young-Hee
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.2
    • /
    • pp.27-42
    • /
    • 2015
  • The aim of this research is to investigate the difference in the capturing opportunities for each type of venture companies in the industry undergoing competition of a dominant design and then figure out the reason why they can be successful. Existing studies on venture companies are focused on the way to enhance a firm's competencies by acquiring and combining its resources. However, it is important for startups which have a lack of resources and capabilities to capture the opportunity to survive by understanding a changing environment. This study is focused on opportunity capture and strategic response to a changing environment and attempts to select and observe startup companies which are able to capture the opportunity and enter the market in the industry undergoing dominant design competition. In order to find out its difference in different types of business, we select one case from hardware startups and the other from software startups. According to the result of this study, the hardware startup focuses on market extension by lowering their prices and the software startup strives to induce more users to participate by the universalization of enabling technology so as to extend and standardize their technology in the environment undergoing dominant design competition. This feature of environment leads the difference in the approach for successfully capturing opportunity and thus hardware firms need to recognize the opportunity with profit potential from relationship with a number of cooperative firms while software firms need to identify the opportunity for extension of enabling technology which can be used by many users.

  • PDF

Study of carbon nanotube cathode fabricated by screen printing on field emission properties (스크린 인쇄법으로 제작한 탄소나노튜브 캐소드의 전계방출 특성에 관한 연구)

  • 조영래
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.27-27
    • /
    • 2003
  • 최근 탄소나노튜브를 전계방출 표시소자(FED, field omission display)용 에미터 재료로 사용한 캐소드 개발에 대한 연구가 활발히 진행되고 있다. 캐소드전극으로는 투명전도성 반도체 박막인 ITO를 사용하고, 에미터용 재료로는 탄소나노튜브를 사용해서 스크린 인쇄법으로 2극(diode type)형 전계방출 소자용 캐소드를 제작하였다. 본딩재(bonding materials)의 종류와 공정변수를 달리해서 에미터용 탄소나노튜브와 ITO 캐소드 전극 사이의 전기적 접촉방법을 변화시켰을때 탄소나노튜브 캐소드의 전계방출 특성을 체계적으로 연구하였다. 첫째로, 본딩재의 전기전도성 (electrical conductivity)을 변수로 해서 탄소나노튜브 에미터의 전계강화(fold enhancement) 효과를 연구한 결과 본딩재의 구성 성분중 부도체(insulator)의 분율이 높을수록 전계강화 효과가 크게 나타남을 확인하였다. 두 번째로, ITO박막 캐소드전극과 탄소나노튜브 잉크 사이에 중간층(inter layer)을 형성시켜서 중간층이 전계방출 특성에 미치는 영향을 연구하여, 중간층의 존재가 탄소나노튜브의 전계방출 전류의 균일성과 전류밀도의 증가에 기여하는 것을 확인하였다. 본 연구의 결과 전계방출 전류가 안정적이면서 동시에 전계방출 효율이 크게 개선된 탄소나노튜브 캐소드를 제작하는 공정기술이 개발되었다. 개발된 기술은 기존의 방법에 비해서 탄소나노튜브 캐소드의 진공패키징시 아웃개싱(outgassing)의 양도 현격하게 작았으며, 에미터와 캐소드 전극 사이의 본딩력(adhesion)도 우수해서 항후 탄소나노튜브 전계방출 표시소자의 개발에 크게 기여할 것으로 판단된다.luminum 첨가량이 증가함에 따라 세라믹 수율도 증가하였음을 확인하였다. 합성된 aluminum-contained polycarbosilane은 20$0^{\circ}C$에서 1시간 동안 불융화과정을 거쳐 환원 및 진공 분위기에서 고온 열처리하였으며 이로부터 얻어진 시료에 대해 XRD분석을 수행하였다. SEM과 TEM을 이용하여 미세구조를 관찰하였다./100 duty로 구동하였으며, duty비 증가에 따라 pulse의 on-time을 고정하고 frequency를 변화시켰다. dc까지 duty비가 증가됨에 따라 방출전류의 양이 선형적으로 증가하였다. 전압을 일정하게 고정시키고 각 duty비에서 시간에 따라 방출전류를 측정한 결과 duty비가 높을수록 방출전류가 시간에 따라 급격히 감소하였다. 각 duty비에서 방출전류의 양이 1/2로 감소하는 시점을 에미터의 수명으로 볼 때 duty비 대 에미터 수명관계를 구해 높은 duty비에서 전계방출을 시킴으로써 실제의 구동조건인 낮은 duty비에서의 수명을 단시간에 예측할 수 있었다. 단속적으로 일어난 것으로 생각된다.리 폐 관류는 정맥주입 방법에 비해 고농도의 cisplatin 투여로 인한 다른 장기에서의 농도 증가 없이 폐 조직에 약 50배 정도의 고농도 cisplatin을 투여할 수 있었으며, 또한 분리 폐 관류 시 cisplatin에 의한 직접적 폐 독성은 발견되지 않았다이 낮았으나 통계학적 의의는 없었다[10.0%(4/40) : 8.2%(20/244), p>0.05]. 결론: 비디오흉강경술에서 재발을 낮추기 위해 수술시 폐야 전체를 관찰하여 존재하는 폐기포를 놓치지 않는 것이 중요하며, 폐기포를 확인하지 못한

  • PDF

The utility of three-dimensional models in complex microsurgical reconstruction

  • Ogunleye, Adeyemi A.;Deptula, Peter L.;Inchauste, Suzie M.;Zelones, Justin T.;Walters, Shannon;Gifford, Kyle;LeCastillo, Chris;Napel, Sandy;Fleischmann, Dominik;Nguyen, Dung H.
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.428-434
    • /
    • 2020
  • Background Three-dimensional (3D) model printing improves visualization of anatomical structures in space compared to two-dimensional (2D) data and creates an exact model of the surgical site that can be used for reference during surgery. There is limited evidence on the effects of using 3D models in microsurgical reconstruction on improving clinical outcomes. Methods A retrospective review of patients undergoing reconstructive breast microsurgery procedures from 2017 to 2019 who received computed tomography angiography (CTA) scans only or with 3D models for preoperative surgical planning were performed. Preoperative decision-making to undergo a deep inferior epigastric perforator (DIEP) versus muscle-sparing transverse rectus abdominis myocutaneous (MS-TRAM) flap, as well as whether the decision changed during flap harvest and postoperative complications were tracked based on the preoperative imaging used. In addition, we describe three example cases showing direct application of 3D mold as an accurate model to guide intraoperative dissection in complex microsurgical reconstruction. Results Fifty-eight abdominal-based breast free-flaps performed using conventional CTA were compared with a matched cohort of 58 breast free-flaps performed with 3D model print. There was no flap loss in either group. There was a significant reduction in flap harvest time with use of 3D model (CTA vs. 3D, 117.7±14.2 minutes vs. 109.8±11.6 minutes; P=0.001). In addition, there was no change in preoperative decision on type of flap harvested in all cases in 3D print group (0%), compared with 24.1% change in conventional CTA group. Conclusions Use of 3D print model improves accuracy of preoperative planning and reduces flap harvest time with similar postoperative complications in complex microsurgical reconstruction.