• Title/Summary/Keyword: Printing Type

Search Result 510, Processing Time 0.024 seconds

Concentration of Urinary Hippuric Acid in Toluene-Exposed Workers According to the Specific Characteristic of Work

  • Kwon, Se-Young;Na, Young-Ak;Kim, Sang-Rak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.1
    • /
    • pp.17-23
    • /
    • 2012
  • This study is assessed the urinary hippuric acid (HA) concentration in toluene-exposed workers. Toluene is widely used in the coating, printing, painting and petroleum industries. We analyzed the hippuric acid level of toluene-exposed workers (males: 198, females: 63) from 2008 to 2010 and examined the relationship between hippuric acid and the characteristics of their work. The measurements of the urinary hippuric acid were confirmed by high-performance liquid chromatography. Among the subjects, males had on average more work experience than females (males: 9.17 years, females: 4.45 years), but females showed a higher hippuric acid concentration levels than males (males: 0.26 g/L, females: 0.75 g/L). The mean of the HA concentration according to the age group was 0.19 g/L in 30's, 0.30 g/L in 40's, 0.54 g/L in 50's, 1.36 g/L in 60's. Those in their 60's had the highest concentration. The mean of HA concentration according to the type of work was 0.70 g/L for the coating, 0.52 g/L for the painting, and 0.16 g/L for the printing industries, revealing that the workers in the coating industry had the highest concentration. By the highest order, the mean of HA concentration by working period was as follows; less than 5 years, ${\leq}5\;years{\sim}<10\;years$. The factors that influence the HA concentration are not only how long one is exposed to toluene but also the type of work, worker's age, and their gender.

  • PDF

Analysis of Wireless Signal Strength in Indoor Environment with Film-Type Dual-Band Frequency Selective Structure (필름형 이중 대역 주파수 선택 구조가 적용된 실내 환경의 무선신호강도 분석)

  • Cho, Sung-Sil;Lee, Sang-Hwa;Yoon, Sun-Hong;Hong, Ic-Pyo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • In this paper, we propose a film-type dual-band frequency selective structure for improving the wireless communication environment in a building. The proposed frequency-selective structure is a miniaturized structure that can control the resonant frequencies of 2.4 GHz and 5 GHz dual band through simple design parameters. We fabricated the frequency-selective surface by screen printing using conductive ink on a thin transparent film and confirmed its performance by measurement. We analyzed the attenuation performance of the unnecessary signal from the outside when the frequency-selective structure designed using the software to analyze the propagation environment performance is applied to the building. To verify the analytical results, the signal strength of the indoor environment was measured by applying the frequency-selective film fabricated on the inner wall of the actual building. The measurement results show that the dual-band frequency-selective film has 29.4 dB and 15.94 dB attenuation performance in the 2.4 GHz and 5 GHz, respectively.

The Usability Assessment of Self-developed Phantom for Evaluating Automatic Exposure Control System Using Three-Dimensions Printing (자동노출제어장치 평가를 위한 3D 프린팅 기반의 자체 제작 팬텀의 유용성 평가)

  • Lee, Ki-Baek;Nam, Ki-Chang;Kim, Ho-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.147-153
    • /
    • 2020
  • This study was to evaluate the usability of self-developed phantom for evaluating automatic exposure control (AEC) using three-dimensions (3D) printer. 3D printer of fused deposition modeling (FDM) type was utilized to make the self-developed AEC phantom and image acquisitions were conducted by two different type of scanners. The self-developed AEC phantom consisted of four different size of portions. As a result, two types of phantom (pyramid and pentagon shape) were created according to the combination of the layers. For evaluating the radiation dose with the two types of phantom, the values of tube current, computed tomography dose index volume (CTDIvol), and dose length product (DLP) were compared. As a result, it was confirmed that the values of tube current were properly reflected according to the thickness, and the CTDIvol and DLP were not significantly changed regardless of AEC functions of different scanners. In conclusion, the self-developed phantom by using 3D printer could assess whether the AEC function works well. So, we confirmed the possibility that a self-made phantom could replace the commercially expensive AEC performance evaluation phantom.

Design of Film-Type Frequency Selective Surface Structure Based on Printed Electronic Technology to Implement Frequency-Selective Space in Buildings (건물 내 주파수 선택적 공간 구현을 위한 인쇄전자 기술 기반 필름형 주파수 선택 표면구조 설계)

  • Lee, In-Gon;Yoon, Sun-Hong;Hong, Ic-Pyo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.1007-1010
    • /
    • 2017
  • In this paper, a frequency selective surface(FSS) with bandstop operation for radio-frequency spectrum management is presented. The proposed FSS is composed of patterns of fractal-based miniaturized unit cells for stable performance for angles of incidence and polarizations. For practical applications requiring high productivity and environmental compatibility, we fabricated a film-type FSS by screen-printing using Ag ink, rather than a conventional manufacturing method using a printed circuit board. To validate this study, we measured the transmission characteristics of the proposed FSS using the free-space measurement method, and observed the received strength of signal penetrating the FSS film applied to a wall.

Disposable Strip-type Sensors for Detection of Free Chlorine (유리염소 측정을 위한 일회용 스트립 센서)

  • Kim, Seung Ki;Kang, Tae Young;Cha, Geun Sig;Nam, Hakhyun;Shin, Jae Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.4
    • /
    • pp.242-248
    • /
    • 2012
  • The measurement of residual chlorine as a disinfectant is very important to ensure the safety against the pathogenic microbes and to suppress injection. The portable free chlorine sensor was fabricated with a disposable strip format by a screen printing method. The strip sensors prepared with a carbon-Ag/AgCl(cathode-anode) combination exhibited less interfering responses towards combined chlorine species(especially $NHCl_2$) and oxygen than the sensors prepared with other metals(i.e., gold and platinum). Free chlorine was determined chronoamperometrically with carbon-based electrodes at an applied potential of -0.3 V(vs. Ag/AgCl). A channel was built on the strip-type electrode for easy sampling, and the resulting strip sensors were employed to determine the concentrations of residual free chlorine.

Bonding of conventional provisional resin to 3D printed resin: the role of surface treatments and type of repair resins

  • Lim, Na-Kyung;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.322-328
    • /
    • 2020
  • PURPOSE. This study evaluated the shear bond strength between 3D printed provisional resin and conventional provisional resin depending on type of conventional provisional resin and different surface treatments of 3D printed resin. MATERIALS AND METHODS. Ninety-six disc-shaped specimens (Ø14 mm × 20 mm thickness) were printed with resin for 3D printing (Nextdent C&B, Vertex-Dental B. V., Soesterberg, Netherlands). After post-processing, the specimens were randomly divided into 8 groups (n=12) according to two types of conventional repair resin (methylmethacrylate and bis-acryl composite) and four different surface treatments: no additional treatment, air abrasion, soaking in methylmethacrylate (MMA) monomer, and soaking in MMA monomer after air abrasion. After surface treatment, each repair resin was bonded in cylindrical shape using a silicone mold. Specimens were stored in 37℃ distilled water for 24 hours. The shear bond strength was measured using a universal testing machine at a crosshead speed of 0.5 mm/min. Failure modes were analyzed by scanning electron microscope. Statistical analysis was done using one-way ANOVA test and Kruskal-Wallis test (α=.05). RESULTS. The group repaired with bis-acryl composite without additional surface treatment showed the highest mean shear bond strength. It was significantly higher than all four groups repaired with methylmethacrylate (P<.05). Additional surface treatments, neither mechanical nor chemical, increased the shear bond strength within methylmethacrylate groups and bis-acryl composite groups (P>.05). Failure mode analysis showed that cohesive failure was most frequent in both methylmethacrylate and bis-acryl composite groups. CONCLUSION. Our results suggest that when repairing 3D printed provisional restoration with conventional provisional resin, repair with bis-acryl composite without additional surface treatment is recommended.

Experimental fabrication of tapped band pass filter of $BiNbO_{4}$ ceramics ($BiNbO_4$ 세라믹스를 이용한 태핑기법의 적층칩 대역 필터에 관한 연구)

  • 고상기;지기만;김경용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.4
    • /
    • pp.988-996
    • /
    • 1998
  • BN ceramics with 0.07wt% $V_{2}O_{5}$ and 0.03wt% CuO(BNC3V7) sintered at $900^{\circ}C$ where it is possible for these to be co-fired with Ag electrode. Dielectricconstant of 44.3, TCF of 22 ppm$/^{\circ}C$ and $Qxf_{o}$ value of 22,000 GHz can be obtained from BNC3V7, multilayer type band pass filters using tapped method and conventional method were designed for PCS (Personal Communication System) applications. Tapped method by adopting input/output-tapping scheme the chip filter stucture becomes simpler and needs fewer layers than that using the conventional input/output-coupling scheme. A multilayer type band pass filter fabricated by screen-printing with silver electrode after tape casting. The simulated characteristics of the fabricated filters sintered at $900^{\circ}C$ were compared with the designed ones. Even though the centered frequencies of tapped and conventional band pass chaip filters were measured to shift about 90MHz downward, the band pass characteristics of both filters were similar that of designed ones. The spuriousresonance characteristic of tapped pass chip filter was better than that of conventional chip filer.

  • PDF

The Analysis on the Torso Type Dress Form Developed Through the 3-D Virtual Body Modeling of the Korean Female Fashion Models (국내 여성 패션모델의 3차원 가상인체 모델링을 통한 토르소형 인대 개발과 그 특성 분석)

  • Park, Gin Ah
    • Journal of the Korean Society of Costume
    • /
    • v.65 no.2
    • /
    • pp.157-175
    • /
    • 2015
  • The study was aimed to develop a torso-type dress form representing body features of the female fashion models in Korea. To fulfill this purpose, 5 female fashion models aged between 20 and 26 having the average body measurements of professional fashion models in Korea were selected and their 3-D whole body scanned data were analysed. The 3-D whole body scanning method enabled to generate a virtual female fashion model within the CAD system by measuring the subjects' body shapes and sizes. In addition, the virtual model's body data led the development of a standard female fashion model dress form for the efficient fashion show preparation. In order to manufacture the real dress form for female fashion models, 3-D printing technology was adopted. The consequent results are as follows: (1) the body measurements (unit: cm) of the developed dress form were: biacromion length, 36.0, bust point to bust point, 16.6, front/back interscye lengths, 32.0/33.0, neck point to breast point, 26.0, neck point to breast point to waist line, 41.5, waist front/back lengths, 34.5/38.5, waist to hip length, 24.0, bust circumference, 85.0, underbust circumference, 75.0, waist circumference, 65.0, hip circumference, 92.0. (2) the body measurements differences between the developed and existing dress forms were highlighted with the body measurements of neck point to breast point and waist to hip length. (3) the body shape features of the developed dress form showed that bust, shoulder blade, shoulder slope, abdomen and back waist line to hip line parts were more realistically manufactured.

Effect of Thickener and Mordants on the Printing Properties of Cotton and Silk Fabrics Printed with Phellodendron Amurense Extract (호료와 매염제가 황벽추출물로 날염한 면/견직물의 날염성질에 미치는 영향)

  • Song, Yu Sun;Song, Wha Soon
    • Fashion & Textile Research Journal
    • /
    • v.15 no.5
    • /
    • pp.825-833
    • /
    • 2013
  • In this study, the dyeing properties of Phellodendron amurense on cotton and silk fabrics were evaluated to establish a scientific database of dyeing methods using natural dyes with the ultimate aim of facilitating the practical use of these dyes. The optimal thickener and dyeing concentrations depending on the thickener type were identified when dyeing with P. amurense, and the fabric color, color fastness, and antibiosis were examined for various thickeners, fabrics, and mordants. The results were as follows.: The optimal concentrations of thickeners when dyeing on cotton and silk fabrics were CMC 3% (w/w), Mayprogum 7% (w/w), and Indalka 9% (w/w). The optimal concentration of P. amurense was 25% (w/w), irrespective of the type of thickener. To maintain the hue unique to P. amurense, thickening with Mayprogum or Indalka and mordanting with Al was effective for cotton, while thickening with Mayprogum or Indalka and mordanting with Al or thickening with CMC and mordanting with gallnut was effective for silk. The dry-cleaning fastness and abrasion resistance of cotton fabrics dyed with P. amurense were excellent at the 4-5 level. Gallnut was effective for washing fastness and perspiration fastness against color degradation, and FFC was effective for light fastness. The washing fastness, dry-cleaning fastness, abrasion resistance, and perspiration fastness of silk fabrics dyed with P. amurense were excellent at level 4, except for washing and perspiration fastness, and FFC was effective for the improvement of light fastness. Dyeing cotton and silk fabrics with P. amurense thus yielded antibiosis and excellent washing fastness.

Comparison of PCB Surface Treatment Effect Using UV Equipment and Atmospheric Pressure Plasma Equipment (UV 장비 및 대기압 플라즈마 장비를 이용한 PCB 표면 처리 효과 비교)

  • Ryu, Sun-Joong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.3
    • /
    • pp.53-59
    • /
    • 2009
  • Low pressure mercury lamp type UV equipments have been widely used for cleaning and modification of PCB surfaces. To enhance the productivity of the process, we newly developed remote DBD type atmospheric pressure plasma equipment. The productivity of both equipments could be compared by measuring surface contact angle for various transferring speed. By the result of the measurement, we could verify that the productivity of the atmospheric pressure plasma be superior to the productivity of the UV equipment. XPS experiments confirmed that the surface effect of the UV and atmospheric pressure plasma processing are similar for each other. Organic contamination level was reduced after the processing and some surface elements were oxidized for both cases. Finally, the atmospheric pressure plasma equipment was adapted to flip chip BGA's flux printing process and it was concluded that the printing uniformity be enhanced by the atmospheric pressure plasma surface treatment.

  • PDF