• 제목/요약/키워드: Priming Discharge

검색결과 42건 처리시간 0.028초

High Speed Driving Technique in AC PDPs

  • Shin, Bhum-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1181-1184
    • /
    • 2007
  • The new self-priming addressing driving scheme was proposed to improve an address discharge time lag. It utilizes the priming effect maintaining the priming ramp discharge during an address period and the address discharge time lag is significantly improved. In this study, the basic characteristics of the priming ramp discharge are presented.

  • PDF

PDP의 프라이밍 방전특성에 관한 연구 (A Study on the Characteristics of Priming Discharge in the PDPs)

  • 손현성;채승엽;염정덕
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.29-33
    • /
    • 2002
  • Period which does an electric condition of panel in reset in the driving method of PDP is reset period. This research experimentally analyzed the priming discharge characteristic of reset period. The amount of wall charge and the accumulation time accumulated by priming discharge are unrelated to width of priming pulse. And, self-erase discharge has the relation in the amount of wall charge by priming discharge. Then, it relates also to space charge generated by priming discharge. Moreover, space charge which helps self-erase discharge exists to about 22$mutextrm{s}$ after generating priming discharge. And, it is suitable within 12$mutextrm{s}$ of priming pulse width for efficient reset.

  • PDF

하전 입자 효과를 이용한 Plasma Display Panel의 고속 구동 파형에 관한 연구 (Studies on High Speed Addressing Driving Scheme using the Priming Effect in Plasma Display Panel)

  • 신범재;박상식
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.45-52
    • /
    • 2009
  • 본 연구는 Full-HD급 PDP의 고속 구동 구현을 위한 새로운 구동 방식에 관한 연구이다. 새로운 SPA (self-priming address) 구동 파형은 어드레스 구간에서 지속적인 프라이밍 방전을 유지하여 하전 입자 효과를 이용하여 어드레스 방전 지연 시간을 개선하기 위하여 제안되었다. 본 연구에서는 프라이밍 방전의 기본 특성에 대해 조사하였으며, 안정적인 프라이밍 방전을 유지할 수 있는 초기화 펄스 및 프라이밍 램프 펄스를 도출하였다. 특히, 프라이밍 램프 펄스의 기울기가 0.1[$V/{\mu}s$]의 미약한 프라이밍 방전의 경우에 대해서도 기존 방식의 1.2[${\mu}s$]의 어드레스 방전 지연 시간을 0.8[${\mu}s$]로 획기적으로 개선할 수 있는 것을 확인하였다.

PDP의 ADS 구동방식에서의 초기화 방전특성에 관한 연구 (A Study on the Characteristics of Reset Discharge in the ADS Driving Method for the PDPs)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.17-22
    • /
    • 2003
  • 본 연구에서는 mP의 ADS 구동방식에서 초기화기간의 프라이밍 방전 특성에 대하여 실험적인 해석을 하였다. 방전에 의해 축적되는 벽전하의 총량과 벽전하가 축적되는 시간은 프라이밍 펄스의 폭과 무관하다. 또한 과잉 벽전하에 의한 자기소거 방전은 프라이밍 방전에 의한 벽전하량과 관계가 있으며 또한 프라이밍 방전에 의해 생성되는 공간전하와도 관계가 있다. 실험결과 프라이밍 펄스 폭은 8[$\mu\textrm{s}$], 전압은 163[V] 정도가 최적이다. 그리고 자기소거방전을 돕는 공간전하는 파라이밍 방전이 발생한 직후로부터 약 16[$\mu\textrm{s}$] 동안 존재한다. 그러므로 효과적인 초기화 과정을 위한 프라이밍 펄스의 폭은 16[$\mu\textrm{s}$] 이내가 적당하다.

플라즈마 디스플레이 패널의 새로운 표시기간 중첩 프라이밍 방전 기술 (Novel Priming Discharge Overtopping with Display Period Technique for the Plasma Display Panels)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.27-33
    • /
    • 2007
  • 램프(ramp) 파형의 프라이밍 펄스를 표시방전 유지기간에 중첩시켜 인가함으로써, 단일 구동회로를 사용하여 플라즈마 디스플레이 패널(PDP)의 전체를 동시에 방전시킬 수 있는 새로운 프라이밍(priming) 방전기술을 고안하였다. 실험결과로부터 표시방전이 없는 화소에만 프라이밍 방전이 일어남을 확인하였으며 표시방전은 프라이밍 펄스의 영향을 거의 받지 않는다는 것을 알았다. 또한 제안된 프라이밍 방전 기술을 적용한 구동방식을 사용하여 0.7 [${\mu}s$]의 어드레스 펄스폭을 가지는 고속 구동을 실현하였고 40[V]의 넓은 어드레스 전압 범위를 얻었다. 이 결과는 1080개의 수평주사선수를 가지는 full-HDTV PDP를 밝기의 감소 없이 구동할 수 있으며 이 기술은 상용의 구동IC를 사용할 수 있도록 설계되었으므로 상용화 가능성도 높다.

Microdischarge using priming particles for reducing neon emission in AC plasma display panel with Ne-Xe-He gas mixture

  • Kim, Hyun;Jang, Sang-Hun;Tae, Heung-Sik;Chien, Sung-Il;Lee, Dong-Ho
    • 센서학회지
    • /
    • 제15권4호
    • /
    • pp.284-290
    • /
    • 2006
  • This study uses neon, xenon, and helium gas mixture microdischarge to determine the effects of priming particles on the neon emission characteristics in an alternate current plasma display panel (AC PDP). The infrared (823 nm) and neon emission (585 nm) intensities are measured and compared in the blue cells in the case of new discharge with priming particles or conventional discharge without priming particles, respectively. It is found that the priming particles can produce a plasma discharge effectively even under the weak electric field condition, thereby resulting in reducing the neon emission intensity remarkably without sacrificing the IR emission intensity. As a result, it is found that the Ne emission intensity is reduced by about 46.4 % but the blue visible emission intensity is increased by about 15.2 % when compared with the conventional discharge without priming particles.

표시기간 중첩 프라이밍 구동기술에 의한 플라즈마 디스플레이 패널의 고속구동특성 (High-Speed Characteristics of Plasma Display Panel using Priming Overlapping with Display Drive Method)

  • 염정덕
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.2004-2009
    • /
    • 2007
  • A new high-speed drive method for the plasma display panel is proposed. In this method, the address period is inserted for the rest period of the sustain pulses and the priming pulse is applied on the entire panel at the same time overlapping with the sustain period. The ramp shaped priming pulse can be made with a simple drive circuit in this technology and the stable sustain discharge can be induced even by a narrow scan pulse in help of the space charge generated from the address discharge. From the experiments, it is ascertained that the priming pulse hardly influences the sustain discharge. Moreover, the voltage margin of the sustain discharge is almost constant though that of the address discharge broadens with narrowing the scan pulse width. And, if the time interval between the scan pulse and the sustain pulse is within $6{\mu}s$, the voltage margin of the address and the sustain discharges are unaffected though the applied position of the scan pulse is changed. High-speed driving with the address pulse of $0.7{\mu}s$ width was achieved and the address voltage margin of 20V and the sustain voltage margin of 10V were obtained.

A New High Speed Addressing Method Using The Priming Effect in AC PDP

  • Kim, Jae-Sung;Yang, Jin-Ho;Kim, Tae-Jun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.105-108
    • /
    • 2003
  • A new high speed addressing method is proposed to reduce the addressing time below lus per line in AC PDP. In this method, the priming discharge is used to achieve a high speed addressing without adding an auxiliary electrode. Two different types of priming discharges were studied to achieve a high speed addressing and also reduce the inherent light output caused by the priming discharge in order to improve the contrast ratio characteristics. In the panel experiment, the addressing was successfully done with a lus address pulse width in the new method and the better contrast ratio was achieved in the Y-A priming rather than the Y-X priming case even though the reduction of the address period was smaller than that of the Y-X priming due to the extra address time for the priming discharges.

  • PDF

플라즈마 디스플레이의 공간전하 특성에 관한 연구 (A Study on the Characteristics of Space Charge for the Plasma Display)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제15권6호
    • /
    • pp.1-7
    • /
    • 2001
  • 플라즈마 디스플레이의 구동원리를 해석하기 위하여 공간전하가 방전특성에 미치는 영향을 연구하였다. 프라이밍(priming) 방전에 의해 발생된 공간전하는 다음 방전의 방전지연시간을 단축시켜 응답속도를 빠르게 한다. 이러한 영향은 프라이밍 방전 이후 30[$\mu\textrm{s}$] 정도까지 유효하다. 이 공간전하는 프라이밍 셀 인근의 방전개시전압 을 저하시키고 바로 옆의 셀의 방전에 가장 크게 그 영향을 미친다. 그리고 방전 펄스 폭이 좁을수록 방전개시전압 강하 폭이 커지므로 공간전하에 대한 의존도가 강하다. 그러나 펄스 폭 1[$\mu\textrm{s}$] 이상에서는 공간전하에 대한 영향이 매우 미약하게 관측되었다. 그러므로 인접한 방전의 공간전하에 대해 영향을 받지 않고 안정적인 방전이 일어나기 위해서 최소한 펄스 폭이 1[$\mu\textrm{s}$] 이상 되어야 함을 알았다.

  • PDF

AC PDP에서 2차원 수치해석을 이용한 Ramp Reset 구동파형에 따른 방전 특성 분석 (The Discharge Characteristic Analysis of a Ramp Reset Waveform Using a 2-Dimensional Numerical Simulation in AC PDP)

  • 박석재;최훈영;서정현;이석현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권12호
    • /
    • pp.606-615
    • /
    • 2004
  • The discharge characteristics of a ramp reset waveform in the alternating current plasma display panel(ac PDP) were studied using a 2-dimensional numerical simulation. We analyzed the wall charge variation during the reset discharge, address discharge and sustain discharge adopting a ramp reset waveform. Then we investigated the principal parameters for a successful discharge. In this paper, we suggest a new parameter, printing particles' density and its effects on the stability of the ramp discharge. The maximum current flows of the three electrodes during the ramp reset period were decreased with the increase in the priming particles's density which was explained with the wall charge characteristics and the current flow characteristics obtained by a 2-D simulation.