• Title/Summary/Keyword: Primary side control

Search Result 169, Processing Time 0.023 seconds

A Constant-Current and Constant-Voltage Control Method for Primary-Side Regulated Fly-Buck Converter (1차 측 제어 플라이벅 컨버터의 정전류 및 정전압 제어)

  • Younghoon Cho;Paul Jang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.30-38
    • /
    • 2023
  • In this paper, a constant current(CC) and constant voltage(CV) control method using a primary-side regulated(PSR) fly-buck converter is proposed. Because the primary-side structure of the fly-buck converter is the same as that of the synchronous buck converter, it always operates in continuous conduction mode(CCM). Therefore, in the proposed method, the load information on the secondary side can always be easily estimated by measuring the primary inductor current at the midpoint of the switch-on period. An accurate CC/CV control can be achieved through simple calculations based on this estimated information. Consequently, the proposed method is advantageous for optimizing the control performance of the PSR converter. The validity of the proposed control was verified using a 5 W prototype of a PSR fly-buck converter. The experimental results confirmed that the current reference of 500 mA was followed within the error range of 1.2%, and that the voltage reference of 12 V was followed within the error range of 1.8% despite the indirect control of the load current and output voltage from the primary side.

Primary Side Constant Power Control Scheme for LED Drivers Compatible with TRIAC Dimmers

  • Zhang, Junming;Jiang, Ting;Xu, Lianghui;Wu, Xinke
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.609-618
    • /
    • 2013
  • This paper proposes a primary side constant power control scheme for TRIAC dimmer compatible LED drivers. The LED driver is a Flyback converter operated in boundary conduction mode (BCM) to minimize the switching loss. With the proposed control scheme, the input power of the Flyback converter can be controlled by the TRIAC dimming angle, which is not affected by AC input voltage variations. Since the output voltage is almost constant for LED loads, the output current can be changed by controlling the input power with a given conversion efficiency. The isolated feedback circuit is eliminated with the proposed primary side control scheme, which dramatically simplifies the whole circuit. In addition, the input current automatically follows the input voltage due to the BCM operation, and the resistive input characteristic can be achieved which is attractive for TRIAC dimming applications. Experimental results from a 15W prototype verify the theoretical analysis.

New Control Method for Power Decoupling of Electrolytic Capacitor-less Photovoltaic Micro-Inverter with Primary Side Regulation

  • Irfan, Mohammad Sameer;Shin, Jong-Hyun;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.677-687
    • /
    • 2018
  • This paper presents a novel power decoupling control scheme with the bidirectional buck-boost converter for primary-side regulation photovoltaic (PV) micro-inverter. With the proposed power decoupling control scheme, small-capacitance film capacitors are used to overcome the life-span and reliability limitations of the large-capacitance electrolytic capacitors. Then, an improved flyback PV inverter is employed in continuous conduction mode with primary-side regulation for the PV power conditioning. The proposed power-decoupling controller shares the reference for primary side current regulation of the flyback PV inverter. The decoupling controller shapes the input current of the bidirectional buck-boost converter. The shared reference eliminates the phase-delay between the input current to the bidirectional buck-boost converter and the double frequency current at the PV primary current. The elimination of the phase-delay in dynamic response enhances the ripple rejection capability of the power decoupling buck-boost converter even with small film capacitor. With proposed power decoupling control scheme, the additional advantage of the primary-side regulation of flyback PV inverter is that there is no need to have an extra current sensor for obtaining the ripplecurrent reference of the decoupling current-controller of the power-decoupling buck-boost converter. Therefore, the proposed power decoupling control scheme is cost-effective as well as the size benefit. A new transient analysis is carried out which includes the source voltage dynamics instead of considering the source voltage as a pure voltage source. For verification of the proposed control scheme, simulation and experimental results are presented.

Grid-friendly Control Strategy with Dual Primary-Side Series-Connected Winding Transformers

  • Shang, Jing;Nian, Xiaohong;Chen, Tao;Ma, Zhenyu
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.960-969
    • /
    • 2016
  • High-power three-level voltage-source converters are widely utilized in high-performance AC drive systems. In several ultra-power instances, the harmonics on the grid side should be reduced through multiple rectifications. A combined harmonic elimination method that includes a dual primary-side series-connected winding transformer and selective harmonic elimination pulse-width modulation is proposed to eliminate low-order current harmonics on the primary and secondary sides of transformers. Through an analysis of the harmonic influence caused by dead time and DC magnetic bias, a synthetic compensation control strategy is presented to minimize the grid-side harmonics in the dual primary side series-connected winding transformer application. Both simulation and experimental results demonstrate that the proposed control strategy can significantly reduce the converter input current harmonics and eliminates the DC magnetic bias in the transformer.

THREE-DIMENSIONAL SPACE CHANGES AFTER PREMATURE LOSS OF THE PRIMARY FIRST MOLAR: A LONGITUDINAL STUDY (제1유구치의 조기 상실로 인한 공간 변화에 대한 3차원적 분석)

  • Kim, Ji-Yeon;Jung, Da-Woon;Kwak, So-Youn;Yoo, Seung-Eun;Park, Ki-Tae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.297-304
    • /
    • 2008
  • The purpose of this study was to evaluate a 3-Dimensional laser scanner for the space analysis after loss of a primary first molar. Six children with premature loss of a primary first molar were examined using study models taken before and after the extraction. The results were as follows: 1. There was no change in primary molar space after the extraction of a maxillary primary first molar However, 2 out of 3 children experienced primary molar space loss in extraction side of a mandibular primary first molar. 2. Arch width and arch perimeter showed no difference between initial and final model. 3. All primary canines did not show any changes in inclination. Maxillary primary second molars had similar changes in both extraction and control side. However, 2 out of 3 mandibular primary second molars in extraction side showed more lingual tipping compared to control side. Mandibular permanent first molars tipped more lingually in extraction side. 4. In angulation, primary canines showed nothing of significance. Mandibular primary second molars tipped more mesially in extraction side than in control side. Maxillary permanent first molars have increased distal angulation after extraction of primary first molars in both side.

  • PDF

Secondary Indirect Constant Voltage Control Technique for Hybrid Solid State Transformer using Primary Side Information (하이브리드 반도체 변압기의 1차측 정보를 이용한 2차측 간접 정전압 제어 기법)

  • Lee, Taeyeong;Yun, Chun-Gi;Cho, Younghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.420-423
    • /
    • 2020
  • This study proposes an indirect constant voltage control algorithm for hybrid solid-state transformers (HSSTs) by using primary side information. Considering the structure of HSSTs, measuring voltage and current information on the primary side of a transformer is necessary to control the converter and inverter of the power converter. The secondary side output voltage is measured to apply the conventional secondary side constant voltage control algorithm, and thus, the digital control board requires the same rated insulation voltage as that of the transformer. To solve this problem, the secondary voltage of the transformer obtained from the tap voltage is used. Moreover, output voltage decreases as load increases because the proposed indirect constant voltage control scheme does not consider the cable impedance between the secondary output terminal and the load. This study also proposes a technique for compensating the secondary output voltage by using the primary current of the transformer and the resistance value of the cable. An experiment is conducted using a scale-down HSST prototype consisting of a 660 V/220 V tap transformer. The problem of the proposed indirect constant voltage control strategy and the improvement effect due to the application of the compensation method are compared using the derived experimental results.

One Proposal of Vector Control Method of Wound-Rotor Induction Motor

  • Kim, Sang-Bong;Hidehiko, Sugimoto
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.166.2-166
    • /
    • 2001
  • This paper is concerning a vector control of wound-rotor induction motor from the secondary side. When the wound-rotor induction motor is vector controlled from the secondary side, it has the possibility that the vector control can be accurately done because the disturbance input, that is, primary voltage and all state variables, that is, primary currents and secondary currents can be detected. We consider it is deserve research that the vector control of wound-rotor induction motor from the secondary side, because there is the merit that we can reduce the inverter capacity to on the order of half of the motor capacity when we choose twice of the synchronous speed to the rated speed, though there is the problem of the brush maintenance. In this paper, the vector control method of wound-rotor induction ...

  • PDF

The Metal Detection using Primary Current in Contact-less Power Supply (무접점 전원공급 시 1차측 전류를 이용한 금속 물질 검출에 관한 연구)

  • Kim, Yu-Seok;Yu, Joo-Hee;Kim, Choon-Sam;Sung, Won-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.445-452
    • /
    • 2012
  • The impurity detection method applied to existing discriminated the normality(R, L, C) and impurity(Metal) load using mutual RFID/ID method in the contactless power supply in which the primary side and the secondary side are completely separation by using the contactless transformer. However, this kind of system is caused the high cost of the system and complexity of control. Therefore, in this paper was proposed the contact-less power transfer using the primary current that determine normality or impurity load by compare the primary current Amplitude to reference quantity value and design the 3[W] contact-less power transfer and conduct an experiment for demonstrate the validity.

Design of a High-Precision Constant Current AC-DC Converter with Inductance Compensation

  • Chang, Changyuan;Xu, Yang;Bian, Bin;Chen, Yao;Hu, Junjie
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.840-848
    • /
    • 2016
  • A primary-side regulation AC-DC converter operating in the PFM (Pulse Frequency Modulation) mode with a high precision output current is designed, which applies a novel inductance compensation technique to improve the precision of the output current, which reduces the bad impact of the large tolerance of the transformer primary side inductance in the same batch. In this paper, the output current is regulated by the OSC charging current, which is controlled by a CC (constant current) controller. Meanwhile, for different primary inductors, the inductance compensation module adjusts the OSC charging current finely to improve the accuracy of the output current. The operation principle and design of the CC controller and the inductance compensation module are analyzed and illustrated herein. The control chip is implemented based on a TSMC 0.35μm 5V/40V BCD process, and a 12V/1.1A prototype has been built to verify the proposed control method. The deviation of the output current is within ±3% and the variation of the output current is less than 1% when the inductances of the primary windings vary by 10%.

NASAL ASYMMETRY AFTER PRIMARY OPERATIONS IN PATIENTS WITH UNILATERAL CLEFT LIP (일차 토순 수술후의 코입부위의 심미적 평가 제1보 코의 비대칭성)

  • Min, Byong-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.4
    • /
    • pp.390-395
    • /
    • 1994
  • The author evaluated the nasal asymmetry after primary operations in the patients with unilateral cleft lip using full face photographs. The results are as follows : 1. Nasal deviation angle is average 2.98+3.01 degree(ranged from 0 to 10 degree), significantly different from control group(p<0.05). 2. Nasal deviation angle is average 5.1% when inter-medial canthal distance is 100%, significantly different from control group(p<0.05). 3. Difference in nostril size between cleft and noncleft side is 2.1% when inter-medial canthal distance is 100%, significantly different from control group(p<0.05). 4. Nasal attractiveness analysis shows higher points in difference in nostril size, nasal deviation, nasal form in that order. 5. Nasal asymmetry after primary operations in the patients with unilateral cleft lip using full face photographs is related with Nasal deviation angle, Nasal deviation distance and Difference in nostril size between cleft and noncleft side.

  • PDF