• Title/Summary/Keyword: Primary air

Search Result 880, Processing Time 0.034 seconds

Assessment of environmental fatigue in nuclear power plants: A comparative analysis of the effects of plasticity correction

  • Tae-Song Han;Hee-Jin Kim;Nam-Su Huh;Hyeong-Yeon Lee;Changheui Jang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3764-3774
    • /
    • 2024
  • In accordance with Regulatory Guide 1.207, Rev.1, fatigue assessments must be conducted considering the influence of primary coolant environment in nuclear reactors. Environmental fatigue, resulting from corrosion in the primary coolant, is evaluated in air fatigue life assessments through the application of an environmental fatigue correction factor. This environmental fatigue correction factor depends on sulfur content, operating temperature, dissolved oxygen, and strain rate. It remains constant for sulfur content, operating temperature, and dissolved oxygen, while strain rate introduces potential errors based on the analysis method. The current fatigue evaluation procedure for air, following ASME B&PV Code Sec.III, NB-3200, employs elastic analysis with a simplified elastic-plastic correction factor(Ke). However, Ke factor is considered excessively conservative, prompting less conservative alternatives proposed by JSME, RCC-M, ASME Code Case N-779. This study applied both ASME Ke and JSME Ke for fatigue evaluations considering environmental effects. Additionally, fatigue assessments accounting for elastic-plastic effects were conducted using Neuber and Glinka methods, compared with actual experiments. The analysis systematically examined changes in fatigue life and the environmental fatigue correction factor due to plastic effects in environmental fatigue evaluations.

Infant target facilities and facilities for children in elementary school Comparison and Improvement of Indoor Air Quality for Research (영유아 대상 시설의 실내공기질 특성 비교 및 개선방안에 대한 연구)

  • Seo, Byong-Won;Lee, Ju-Hwa;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.591-601
    • /
    • 2013
  • In modern society, we are living indoor at 80 - 90 % or more of the day, therefore most people are exposed to unconscious indoor air pollutants by various causes. When mother and infant, whose level of immunity are weak, are exposed to polluted indoor air, respiratory diseases and atopy can occur by the growth of bacteria. Therefore, appropriate indoor air quality management is important especially at nursery, elementary school and postpartum clinic etc. In this study, we compared the characteristics of the indoor air qualities of primary school facilities and infant facilities. In this study, seasonal effects were investigated. Also the effects of individual activity area were studied for indoor air quality. During summer season(May-August), the air qualities of each 16 elementary school and nursery school were investigated. During winter season(October-december), the air qualities of each 10 elementary school and nursery school were investigated. As a result, during winter season in 10 of 16 nursery school, $CO_2$ concentration exceeded regulation level of 1000 ppm. This resulted from the operation of heating system and poor ventilation. Also the air quality of all parameters during winter season were worse than during summer, maybe due to poor ventilation. Except HCHO, the concentrations of other parameters were higher in nursery school. This seems to result from relatively low individual activity area of nursery school than elementary school. From this research, more strong regulation for ventilation and installation of air purifier should be implemented.

A Study on the Change in Forest Community by Air Pollution at Yocheon District (大氣汚染에 依한 麗川地域의 森林群集變化에 關한 硏究)

  • Kim, Joon-Seon;Kim, Tae-Wook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.3
    • /
    • pp.1-10
    • /
    • 1986
  • Nowadays, air pollution by increasing consumption of fossil fuels resulting from rapidly growing population and industrialization has caused the adverse effects on terrestrial ecosystems and become one of the most serious problems causing environmental discriptions. Air pollution such as $SO_2, HF, NO_X,$ fly ash, ozone and PAN might influence plant growth, reproduction, nutrient cycling, photosynthesis and predisposition to entomological and pathological stresses on plants. Furthermore, accumulation of those toxic substances in forests might cause subtle or serious changes in the structure and function of forest ecosystems. Since 1970s, a number of large industrial complexes had been constructed as a part of industrialization plan in Korea. Accordingly, the forest exosystems around them has been under chronic influences of air pollution and effects of air pollution on plants became a matter of concern. In Yocheon Industrial Complex which consisted of lots of petrochemical plants and a phosphatic fertilizer manufacturing plant, forests has been exposed to chronic air pollution, mainly HF and $SO_2$ gas, Various reports were available to investigate the potential effects of air pollution on crops and forest trees in Yocheon. Kim and Kim surveyed vegetation by naked eye method and reported 71 families, 150 genera and 158 species were growing within a 2 km from air pollution sources in 1981. Needle injuries on Pinus spp. in the polluted area water reported by Kim, et al. and Kim, et al. Kim, et al. investigated the primary production of Pinus thunbergii forests in the polluted area and verified that growth inhibition of Pinus thunbergii was attributable to air pollution. Thus, previous reports suggested that forest ecosystems around Yocheon Industrial Complex were influenced adversely by air pollution. The objective of this study was to investigate the subtle ecological changes in forest community exposed to chronic air pollution in Yocheon.

  • PDF

Development of a Duct Cleaning Robot and Technology Trends for Subway Stations (지하역사 덕트 청소로봇 기술동향 및 개발)

  • Jeong, Woo-Tae;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1335-1341
    • /
    • 2011
  • Conserving clean air and removing contaminants and particular matters accumulated in the ventilation system of the subway stations are key issue for green railway environment. There is no national guideline or industrial regulations to sustain clean duct and ventilation system, which requires rapid reformation of cleaning procedure and system. In fact, accumulated various particular matters and dusts can occur secondary air contamination and become a primary health harm factor for subway passengers. This study investigates various duct cleaning technologies and trends. In additon, effective cleaning method with an automated robot device is proposed. In particular, current dust cleaning technologies and duct cleaning robots are analyzed based on their functions and feasibilities. The proposed design of automated device is expected to save the operating cost of subway HVAC system and sustain clean air environment.

  • PDF

An Experimental Study of the Flow Characteristics of Cylinder Head Port for Medium-Speed Diesel Engines (중속 디젤엔진의 실린더 헤드포트 유동 특성 실험 연구)

  • Kim, Jin-Won;Ghal, Sang-Hak
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.790-795
    • /
    • 2001
  • Since the characteristics of combustion and pollutant in Diesel engines were mainly affected by the characteristics of in-cylinder gas flow and fuel spray, an understanding of those was essential to the design of the D.I. Diesel engines. The improvement of volumetric efficiency of air charging into combustion chamber is a primary requirement to obtain better mean effective pressure of an engine. Since the air resistances in intake and exhaust flow passages, valve lift and valve shape influence greatly to the volumetric efficiency, it is very important to investigate the flow characteristics of intake and exhaust port which develops air motion in the combustion chamber. This paper presents the results of an experimental investigation of steady flow through the various kinds of commercial cylinder head ports, and the development procedures of HHI's H21/32 prototype cylinder head ports.

  • PDF

A Proposal on the New Air Emission Source Categories (새로운 대기오염물질 배출원 분류체계에 관한 제언)

  • 홍지형;허정숙;이덕길;석광설;이대균;엄윤성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.3
    • /
    • pp.231-245
    • /
    • 2002
  • A better knowledge of emission inventories can serve several important functions such as provision of public information, identification of primary sources, assessment of temporal and spatial trend, and analysis for national modelling studies. The purpose of this paper is to propose the new air emission source categories on the basis of the Korea Standard Industrial Classification. Hence, the paper focuses on reviewing and comparing the air emission sources categories of USEPA, and EU. The new emission source categories compose Tiers 1, 2, and 3. For Tier 1, there are 14 categories; fuel combustion-utilities, industries, and heating and others, chemical and allied product manufacturing, metals processing, and petroleum and related industries, etc. Tier 2 consists of small categories classified minutely in Tier 1. Tier 3 connects the categories of Tier 2 with the Korea Standard Industrial Classification.

The Effect of Particle Size on Ignition Characteristics of Pulverized High-Volatile Bituminous Coal

  • Kim, Hyung-Taek
    • Journal of Energy Engineering
    • /
    • v.2 no.3
    • /
    • pp.285-292
    • /
    • 1993
  • A cylindrical-shape, horizontal furnace was used to investigate the effect of particle size on the pulverized coal combustion behavior. Three differently-sized fractions (5, 30, and 44 microns in average diameter) of high-volatile bituminous coal, were burned in the test furnace. Ignition characteristics of pulverized coal flame were determined through the amount of methane in the carrier gas for the self-sustaining flame. Easiest ignition occurred with the immediately-sized coal particles. Ignition of coal jet flame appeared to occur through a gas-phase homogeneous process for particles larger than 30 microns. Below this limiting size, heterogeneous process probably dominated ignition of coal flame. Oxygen concentration of combustion air was varied up to 50%, to determine the oxygen-enrichment effect on the coal ignition behavior. Oxygen enrichment of primary air assisted ignition behavior of pulverized coal flame. However, enrichment of secondary air didn't produce any effect on the ignition behavior.

  • PDF

Effect of Operating Conditions on Characteristics of Combustion in the Pulverized Coal Combustor (미분탄 연소로의 운전조건이 연소특성에 미치는 영향)

  • Kang, Ihl-Man;Kim, Ho-Young
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.139-148
    • /
    • 1999
  • In oder to analyze the effect of operating conditions on pulverized coal combustion, a numerical study is conducted at the pulverized coal combustor. Eulerian approach is used for the gas phase, whereas Lagrangian approach is used for the particle phase. Turbulence is modeled using standard ${\kappa}-{\varepsilon}$ model. The description of species transport and combustion chemistry is based on the mixture fraction/probability density function(PDF) approach. Radiation is modeled using P-l model. The turbulent dispersion of particles is modeled using discrete random walk model. Swirl number of secondary air affects the flame front, particle residence time and carbon conversion. Primary/Secondary air mass ratio also affects the flame front but little affects the carbon conversion and particle residence time. Air-fuel ratio only affects the flame front due to lack of oxygen. Radiation strongly affects the flame front and gas temperature distribution because pulverized coal flame of high temperature is considered.

  • PDF

A Study on Air and Gas System of Coal Fired Power Plant (석탄화력발전소의 공기 및 가스시스템 모델에 관한 연구)

  • Jung, Hwan-Joo;Kim, Tae-Hyun;Ryoo, Young-Jae;Chang, Young-Hak;Moon, Chae-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.283-285
    • /
    • 2002
  • Boiler combustion systems are large, non-linear systems with numerous interactions between its component parts. In the analysis of such complex systems. dynamic simulation is recognized as a powerful method of keeping track of the myriad of interactions. This paper shows and discusses the developed analysis model, such as the forced draft fan the primary air fan, the furnace and burner system, pulverizer, air preheater and induced draft fan, etc. in accordance with BMCR condition of boiler using the Modular Modeling System(MMS) software.

  • PDF

Mass measuremeant of soilid density standard using weight exchanger (분동교환기를 이용한 고체밀도기준물의 질량측정)

  • 이용재;장경호;오재윤;정상덕
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1659-1662
    • /
    • 2003
  • The mass measurement of solid density standards using weight exchanger is described. KRISS(Korea Research Institute od Standards and Science) has several solid density standards. Their mass have been measured manually only using a mass comparator(Mettler, 1kg - 0.01mg). However, the uncertaity of the manual mass measurement is up to 300 microgarm much more than 32 microgram of advanced NMIS(National Metrology Institutes) for 1 kg silicon sphere which is primary density standards due to an eccentric error and buoyancy correction error. The new system with a weight exchanger is designed and built to improve the measurement accuracy. It comprises a weight exchager, a mass comparator, air density instruments, and application program for automatic measurement. It is evaluated by measuring several elements in an air tight chamber to verify the performance of it.

  • PDF