• Title/Summary/Keyword: Primary Air

Search Result 875, Processing Time 0.025 seconds

Surgical Treatment of Spontaneous Pneumothorax (자연기흉의 외과적 치료)

  • Hur, Yong;Kim, Kyung-Hoon;Kim, Chul-Whan;Park, Sung-Dong;Park, Jae-Hong;Moon, Joon-Ho;Kim, Byung-Yul;Lee, Jung-Ho
    • Journal of Chest Surgery
    • /
    • v.27 no.12
    • /
    • pp.1002-1007
    • /
    • 1994
  • The spontaneous pneumothorax occurs subsequent to a disruption in the continuity of the visceral pleura with escape of free air into the pleural space included primary & secondary pneumothorax that is unrelated to identifiable etiologies such as trauma. In. the 33 year period 1960 to 1993, the 230 cases of open thoracotomy were carried out for definitive treatment of spontaneous pneumothorax, at the Dept. of Thoracic & Cardiovascular Surgery, National Medical Center, Seoul, Korea. There were 193 men & 37 women. They ranged in age from 15 years old to 72 years old. The lesion site was on the right side in 117 and on the left in 97, the 16 cases were in bilateral lesions.Surgical indications included recurrence in 98 cases, persistent air leak in 68 cases, nonexpansion of the lung 37 cases, roentgenologically apparent bullae & blebs in 23 cases, bilateral lesions in 16 cases,combined hemothorax & prevent for recurrence in each 2 cases. The types of operation were bullectomy in 207 cases, wedge resection in 13 cases, decortication & B.P.F. closure in 6 cases,lobectomy in 2 cases, pneumonectomy, plication in each I case. The post operative complication developed in 18 cases[7.8 %], there was I case of death due to sepsis. We believed that open thoracotomy with resection or obliteration of blebs & pleurodes is provided the best protection against recurrence.

  • PDF

Selective Oxidation of Amines to Imines or Nitriles by Manganese Dioxide in Air (공기 중에서 망간 다이옥사이드에 의한 아민에서 이민 또는 나이트릴로의 선택적 산화 반응)

  • Kim, Yo Han;Hwang, Seung Kyu;Lee, Yoon Sik;Kim, Jung Won
    • Applied Chemistry for Engineering
    • /
    • v.25 no.2
    • /
    • pp.215-221
    • /
    • 2014
  • A simple heterogeneous system has been developed by using base treated manganese dioxide (B-$MnO_2$) for the aerobic oxidation of amines under mild reaction conditions of 1 atm of air and $50^{\circ}C$ in hexane. This system was highly efficient to oxidize various kinds of primary or secondary amines including aliphatic, aromatic, and hetero-atomic ones under the applied reaction conditions. Amines were oxidized to nitriles or diimines by the self-condensation or oxidative dehydrogenation through imine intermediate. The B-$MnO_2$ was reused for at least 5 times without any loss of its catalytic performance and showed its cost effectiveness, easy workup, and easy separation of the products for achieving the protocol of green chemistry.

Efficiency Evaluation of Nozawa-Style Black Light Trap for Control of Anopheline Mosquitoes

  • Lee, Hee-Il;Seo, Bo-Youl;Shin, E-Hyun;Burkett, Douglas A.;Lee, Jong-Koo;Shin, Young-Hack
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.2
    • /
    • pp.159-165
    • /
    • 2009
  • House-residual spraying and insecticide-treated bed nets have achieved some success in controlling anthropophilic and endophagic vectors. However, these methods have relatively low efficacy in Korea because Anopheles sinensis, the primary malaria vector, is highly zoophilic and exophilic. So, we focused our vector control efforts within livestock enclosures using ultraviolet black light traps as a mechanical control measure. We found that black light traps captured significantly more mosquitoes at 2 and 2.5 m above the ground (P<0.05). We also evaluated the effectiveness of trap spacing within the livestock enclosure. In general, traps spaced between 4 and 7m apart captured mosquitoes more efficiently than those spaced closer together (P>0.05). Based on these findings, we concluded that each black light trap in the livestock enclosures killed 7,586 female mosquitoes per trap per night during the peak mosquito season (July-August). In May-August 2003, additional concurrent field trials were conducted in Ganghwa county. We got 74.9% reduction (P<0.05) of An. sinensis in human dwellings and 61.5% reduction (P>0.05) in the livestock enclosures. The black light trap operation in the livestock enclosures proved to be an effective control method and should be incorporated into existing control strategies in developed countries.

Assessment of Photochemistry of OH and NO$_3$ at Jeju Island During Asian Dust-Storm Period of the Spring 2001

  • Shon, Zang-Ho;Keith N. Bower;Kim, Ki-Hyun;Lee, Gangwoong;Kim, Jiyoung
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.429-429
    • /
    • 2002
  • This study examines the influence of long-range transport of dust particles and air pollutants on photochemistry of OH and NO$_3$ at Jeju Island (33.17$^{\circ}$ N, 126.10$^{\circ}$ E) during the Asian dust-storm (ADS) period in April 2001. The atmospheric concentrations of criteria pollutants (O$_3$, NO$_2$, CO) and sulfur species were measured at a ground station on Jeju Island, Korea as part of the ACE-Asia intensive operation. Three ADS events were observed during the periods of 10-12, 13-14, and 25-26 April, respectively. The concentrations of the criteria pollutants (i.e., $O_3$, NO$_2$, and SO$_2$) were not significantly different from those during the non-Asian-dust-storm (NADS) period. Average OH and NO$_3$ levels at Jeju Island during the study period (ADS and NADS) were estimated to be 4-10 $\times$ 10$^{5}$ moleculescm$^{-3}$ and 2-4 pptv, respectively. Two main sources of OH radical were the primary production from the reaction of water vapor ($H_2O$) and O(1D) radicals and the reaction of HO$_2$ with NO. CO was a dominant sink of OH during the ADS period: whereas NO$_2$ was the most important during the NADS period. for NO$_3$ radical, a reaction of NO$_2$ with $O_3$ was the most important atmospheric source; while $N_2$O$_{5}$ uptake on dust particles was the most dominant sink during the ADS period.

  • PDF

Numerical Analysis of Single Phase Thermal Stratification in both Cold Legs and Downcomer by Emergency Core Cooling System Injection : A Study on the Necessity to Consider Buoyancy Force Term (비상노심냉각계통 주입에 따른 저온관 및 강수관에서 단상 열성층 수치해석 : 부력항 고려 필요성에 관한 연구)

  • Lee, Gong Hee;Cheong, Ae Ju
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.12
    • /
    • pp.654-662
    • /
    • 2017
  • When emergency core cooling system (ECCS) is operated during loss of coolant accident (LOCA) in a pressurized water reactor (PWR), pressurized thermal shock (PTS) phenomenon can occur as cooling water is injected into a cold leg, mixed with hot primary coolant, and then entrained into a reactor vessel. Insufficient flow mixing may cause temperature stratification and steam condensation. In addition, flow vibration may cause thermal stresses in surrounding structures. This will reduce the life of the reactor vessel. Due to the importance of PTS phenomenon, in this study, calculation was performed for Test 1 among six types of OECD/NEA ROSA tests with ANSYS CFX R.17. Predicted results were then compared to measured data. Additionally, because temperature difference between the hot coolant at the inlet of the cold leg and the cold cooling water at the inlet of the ECCS injection line is 200 K or more, buoyancy force due to density difference might have significant effect on thermal-hydraulic characteristics of flow. Therefore, in this study, the necessity to include buoyancy force term in governing equations for accurate prediction of single phase thermal stratification in both cold legs and downcomer by ECCS injection was numerically studied.

Detection of Misfire in Car Engines using Walsh Discrete Fourier Transform (WDFT를 이용한 자동차 엔진의 실화검출)

  • 김종부;이태표;오정수;임국현
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.67-74
    • /
    • 1998
  • The primary cause of air pollution by vehicles is imperfect combustion of fuel. One of the most usual causes of this imperfect combustion is the misfire in IC engins. The U.S. EPA(Environment Protection Agency) and the CARB(California air Resources Board) have imposed regulations for the detection of misfiring in automotive engines. The OBD-II regulations require that misfire should be monitored by the engine diagnostic system, and that the goal of OBD-II is to alert the driver to the presence of a malfunction of the emission control system. Several solutions to the misfire detection problem have been proposed for the detection of misfires. However, the performance of these methods in the presence of misfire is not altogether clear. This paper presents a precise method and system for internal combustion engine misfire. Present invention based upon measurements of engine roughness as derived from crankshaft angular velocity measurements with special signal processing method. Crankshaft angular velocity signals are processed by WDPT, so that the more reliable misfire detection than the time domain analysis. Experimental work confirms that it is possible to apply the WDFT for the detection of misfires in no-load idle and road testing.

  • PDF

A Review on the Photochemical Oxidant Modeling as Applied to Air Quality Studies in Complex Terrain

  • Lee Hwa-Woon;Kim Yoo-Keun;Won Gyeong-Mee;Park Jong-Kil
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.1 no.1
    • /
    • pp.19-33
    • /
    • 1997
  • The high oxidants, which occur the daily maximum concentrations in the afternoon, are transported into the other region via long range transport mechanisms or trapped within the shallow mixing boundary layer and then removed physically (deposition, transport by mountain wind, etc.) and chemically (reaction with local sources). Therefore, modeling formation of photochemical oxidants requires a complex description of both chemical and meteorological processes. In this study, as a part of air quality studies, we reviewed various aspects of photochemical modeling on the basis of currently available literature. The result of the review shows that the model is based on a set of coupled continuity equations describing advection, diffusion, transport, deposition, chemistry, emission. Also photochemical oxidant models require a large amount of input data concerned with all aspects of the ozone life cycle. First, emission inventories of hydrocarbon and nitrogen oxides, with appropriate spatial and temporal resolution. Second, chemical and photochemical data allowing the quantitative description of the formation of ozone and other photochemically-generated secondary pollutants. Third, dry deposition mechanisms particularly for ozone, PAN and hydrogen peroxide to account for their removal by absorption on the ground, crops, natural vegetation, man-made and water surfaces. Finally, meteorological data describing the transport of primary pollutants away from their sources and of secondary pollutants towards the sensitive receptors where environmental damage may occur. In order to improve our present study, shortcomings and limitation of existing models are pointed out and verification process through observation is emphasized.

  • PDF

Development of Multi Dielectric Barrier Discharge Plasma Reactor for Water Treatment (수처리용 다중 유전체 방벽 방전 플라즈마 반응기 개발)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.22 no.7
    • /
    • pp.863-871
    • /
    • 2013
  • Dielectric discharges are an emerging technique in environmental pollutant degradation, which that are characterized by the production of hydroxyl radicals as the primary degradation species. For practical application of the plasma reactor, reactor that can handle large amounts of water are needed. Plasma research to date has focused on small-scale water treatment. This study was carried out basic study for scale-up of a single DBD (dielectric barrier discharge) plasma reactor. The degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) was used as a performance indicator of multi-plasma reactor. The experiments is divided into two parts: design parameters [effect of distance of single plasma module (1~14 cm), arrangement of ground electrode (single and multi), rector number (1~5) and power number (1~5)]; operation parameter [effect of applied voltage (60~220 V), air flow rate (1~5 L/min), electric conductivity of solution ($1.4{\mu}S/cm$, deionized water)~18.8 mS/cm (addition of NaCl 10 g/L) and pH (5~9)]. Considering the electric stability of the plasma reactor, optimum spacing between the single plasma module was 2 cm. Multi discharge electrodes - single ground electrode array was selected. Combination of power 3-plasma module 5 was the optimal combination for maximum RNO degradation. The optimum 1st voltage and air flow rate for RNO degradation were 180 V and 4 L/min, respectively. The pH and conductivity of the solution was not influencing the RNO degradation.

An Experimental Study of Water Vapor Pressure that occurs at the Interface of a Fluid-Applied Membrane and Concrete (콘크리트와 도막 방수층 계면에 발생되는 수증기압에 관한 실험적 연구)

  • Ko, Jin-Soo;Kim, Mun-Hee;Lee, Sung-Bok;Shin, Yun-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.147-150
    • /
    • 2006
  • Of the total defects that have occurred recently in the Korean construction market, over 30% are caused by the construction of defective waterproofing, and the phenomenon of air pockets in the waterproofing layer, which is caused by the concrete vapor pressure, is known to be the primary cause of defective waterproofing. Accordingly, in this study the theory about the relationship between water pressure and temperature as well as the damp-proofing volume of concrete and, then, the change of vapor pressure volume was measured and analyzed by making a test sample after spraying a dampness remover and a waterproofing material to a prepared test body. As a result of measuring the water vapor pressure for the surface temperature of the waterproofing layer with the fluid-applied membrane temperature based on about $10^{\circ}C$, which is the average temperature of Seoul, it was found that first, the fluid-applied membrane elevated up to about $40^{\circ}C$, and the water vapor pressure generated from the fluid-applied membrane was about $0.3kgf/cm^2$ when the surface temperature of the waterproofing layer was raised up to about $80^{\circ}C$. Second, when the fluid-applied membrane temperature of the waterproofing layer was raised from $30^{\circ}C\;to\;35^{\circ}C,\;about\;0.1kgf/cm^2$ of water vapor pressure was generated, and when supplying a thermal source to raise the fluid-applied membrane temperature of the waterproofing layer from $35^{\circ}C\;to\;40^{\circ}C$, approximately $0.05kgf/cm^2$ of water vapor pressure was generated.

  • PDF

A Study on the Energy Reduction of a Heating Network Through the Application of an Absorption Heat Pump (열원조건 분석 통한 흡수식 히트펌프 적용 열에너지 네트워크의 에너지 절감 예측)

  • Na, Sun-Ik;Lee, Young-Soo;Baik, Young-Jin;Lee, Gilbong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.5
    • /
    • pp.239-248
    • /
    • 2017
  • At the $21^{st}$ Conference of the Parties (COP) of the United Nations Climate change Conference, representatives of the 195 member countries reached an agreement requiring all participating countries, including Korea, to establish proactive measures to fight climate change. Under this vision, energy network technologies are deemed as a key site of research towards meeting this goal. Herein, the headquarters of the Korea Institute of Energy Research (KIER) is a worthy site for carrying out energy network technology research insofar as it contains various heat sources. To prepare for this research, a study was conducted analyzing the heat sources at KIER based on measured data. The study also consisted of developeding simulation models to predict the amount of energy savings that could be derived by replacing an absorption chiller/heater with an absorption heat pump during winter seasons. In our simulation results, we observed a primary energy saving ratio of 65~72% based on the water temperature from the heat source of a coal power plant.