• Title/Summary/Keyword: Primary Air

Search Result 880, Processing Time 0.031 seconds

Effects of Artificial Saliva Contamination on the Bond Strength of Three Dentin Adhesives to Dentin of Primary Teeth (인공타액오염이 유치 상아질에서 3종 상아질 접착제의 결합 강도에 미치는 영향)

  • Bae, Youngeun;Kim, Shin;Jeong, Teasung;Kim, Jiyeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.72-81
    • /
    • 2017
  • The aim of this study was to evaluate the effectiveness of artificial saliva contamination and decontamination procedures at different stages of a bonding procedure on the microtensile bond strength (MTBS) of two one-step self-etch adhesives and a two-step total-etch adhesive to dentin of primary teeth. Forty-two extracted sound primary molars were randomly divided into three groups depending on three adhesives, Scotchbond Universal Adhesive (SBU), All-Bond Universal (ABU) and Prime & Bond NT (PNT). For each adhesive, the teeth were allocated into seven groups. Except for control group, group 1, the groups were contaminated with artificial saliva at three different stages: the groups 2 and 3 - before adhesive application; the groups 4 and 5 - before adhesive polymerization; the groups 6 and 7 - after adhesive polymerization. Decontaminating procedures were rinsing, air-drying (group 2, 4, 6) and air-drying (group 3, 5, 7). The specimens were restored with composite resin (Filtek, Z350) and microtensile bond strength was measured. The data was analyzed with one-way ANOVA and Tukey HSD test (p < 0.05). In the control group, using PNT resulted in significantly higher bond strength than when ABU and SBU were used (p < 0.001). For three adhesives, the groups 2, 4 and 6 had greater bond strength than the groups 3, 5 and 7. Also, when the artificial saliva was contaminated before adhesive polymerization (group 4, 5), it showed a significantly lower bond strength. Generally the two-step total-etch adhesive generated a higher bond strength than the one-step self-etch adhesive. Artificial saliva contamination before adhesive polymerization led to a drastic decrease in bond strength, and rinsing with water followed by air-drying could not recover the bond strength.

Epidemiological Study of Air Pollution and Its Effects on Health of Urban Population (서울시(市) 대기오염(大氣汚染)이 시민보건(市民保健)에 미치는 영향(影響)에 관(關)한 조사연구(調査硏究))

  • Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.2 no.1
    • /
    • pp.5-22
    • /
    • 1969
  • The urban population of our country is rapidly increasing due to many factors of social structure, and sociologists are predicting that the increase rate of the urban population will be over 50% in 1980's. Above all, the population of the capital city of Seoul, is at present more than four millions. Such centring of people in cities, together with the improvement of the standards of living, caused rapid increase in the amount of fuel consumption, and this consumption of fuels became one of the primary sources of the air pollution in cities. Moreover, the heavy traffic, construction of many tall buildings, and the increasing number of new factories due to the industrial development-all these are contributing to make the matter of air pollution worse and worse in the Metropolitan, whose geographical location is quite unfavorable considered from the view point of air pollution. Most homes in Seoul use briquet as fuel, while oils are used in tall buildings. The CO, $SO_2$, and smoke that come from burning of these fuels are a great threat to the health of the urban population. With the purpose of examining the influence of air pollution upon the public health, written inquiries were made upon respiratory diseases, and the carboxyhemoglobin saturation in the blood was measured to determine whether the air pollution may affect the health of the urban population. Method of Health Examination (1) Investigation of Respiratory Diseases Patients' records were examined to figure out the monthly ambulance rate of respiratory patients to the total number of patients treated. On the other hand, by using the questionnaire form approved by the Medical Research Council's Committee on Research into Chronic Bronchitis, investigators interviewed the examinees and inquired into the respiratory symptoms. (2) Measuring of Carboxyhemoglobin Saturation From the ear lobe of the examinees, with the use of the melangeur for the white blood cell counting, blood was taken, and after diluting it ten times with 0.1% $Na{2}CO_{3}$, again diulting it 20 times with 0.5% $Na_{2}\;CO_{3}$, its absorbancy was measured. The following results are obtained from the investigation. (1) It was found out that 7.7% of the total patients under treatment were suffering from upper respiratory infection, acute or chronic bronchitis, bronchial asthma, pulmonary emphysema and bronchiectasis. Of them all, patients with upper respiratory infection numbered the greatest with 4.8% and patients with acute or chronic bronchitis the next with 2.1%, and their monthly ambulance rate was high from December to February during the winter, and from April to May and from September to October during the changeable seasons. (2) The daily ambulance rate of respiratory patients, it was revealed, had a close connection with the concentration of $SO_2$ and CO in the air. (3) It was found out that men were more subject to respiratory disease than women, and both men and women were more liable to the diseases with the advancing of age. (4) People living at Choong-ku with the heavy traffic and in the industrial zones of Yeungdungpo had high frequency of respiratory symptoms. (5) Considered from the view point of occupations, high frequency was found among those without job, with jobs unknown, merchants and intdustrial workers, whose social status was rather low and traffic policemen who were always exposed to the exhaust gas of cars. As for women, the frequency was detected in the order of those from high to low, housewives who were exposed to briquet gas, women with jobs unknown, women without jobs, whose social status was low. (6) Ex-smokers rather than smokers, of both sexes, had higher frequency. As for men, heavy smokers had high frequency, while in women light smokers had rather high frequency which was presumed to be due to their average old age. (7) Men's average of carboxyhemoglobin saturation was 9.48%, while women's was 11.3%, higher than men's. (p<0.05). Age meant no difference in the case of men, but as for women, the saturation was remarkably high between the ages from 20 to 60. (8) No regional difference was detected in the carboxyhemoglobin saturation. (9) The carboxyhemoglobin saturation was found, in the case of men, in the order of office workers, traffic policemen, students, the unemployed, merchants and industrial workers, drivers; and as for women, the order was housewives, office workers, merchants and industrial workers. (10) No significant correlation was found between the carboxyhemoglobin saturation and the concentration of CO detected in kitchens, or between the carhoxyhemoglobin saturation and the passing of time after exposure to briquet gas. No difference of carboxyhemoglobin saturation was detected between smokers and non-smokers, and the degrees of smoking; only, significant negative correlation was found between the passing of time after smoking and the carboxyhemoglobin saturation. It is ture that air pollution causes or aggravates the respiratory diseases, increases the carboxyhemoglobin saturation in the blood, but what seems to be more hazardous to the health is the air polluted by the briquet gas in the kitchens and on-dol rooms rather than the atmospheric air pollution.

  • PDF

Risk Factors for Recurrent Pneumothorax after Primary Spontaneous Pneumothorax (원발 기흉 수술 후 재발의 위험인자)

  • Yu, Jai-Kun;Lee, Seong-Ki;Seo, Hong-Joo;Seo, Min-Bum
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.724-728
    • /
    • 2008
  • Background: The purpose of this study was to identify factors associated with recurrent pneumothorax after wedge resection in primary spontaneous pneumothorax in our hospital. Material and Method: Two hundred thirty-five consecutive patient (98% males; mean age, $23.9{\pm}4.5$ years) who had undergone video-assisted thoracoscopic surgery (VATS) were reviewed retrospectively. The two groups were divided as follows: group A, non-recurrent patients (225 patients [96%]); and group B, recurrent group (10 patients [4%]); the risk factors were compared between the two groups. The single and multiple factors that influenced the recurrence rate were analyzed using Cox's proportional hazard model. Result: There were no significant differences between the recurrent and non-recurrent groups in terms of gender, smoking, site of recurrence, degree of collapse, operative time, and number or weight of resected bullae. The recurrence rate was significantly more common in the following: younger ages, increased height/weight ratio, longer initial air leakage period, and shorter duration of chest drainage. Early aggressive exercise (<30 days) of patients after wedge resection increased the tendency for recurrence. Conclusion: Thoracoscopic wedge resection does not have a higher recurrence rate than open thoracotomy. However, young age, height/weight ratio, continuous air, and duration of chest tube placement were risk factors for a recurrent pneumothorax.

Numerical Study to Develop Low-NOx Multi-nozzle Burner in Rotary Kiln (로터리 킬른용 Low-NOx 다공노즐버너 개발을 위한 수치해석적 연구)

  • Ahn, Seok-Gi;Kim, Jin-Ho;Hwang, Min-Young;Kim, Gyu-Bo;Jeon, Chung-Hwan
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.130-140
    • /
    • 2014
  • Rotary kiln burner has been developed continuously to improve process efficiency and exhaust emission. In this study, the characteristics of the flame and exhaust emission were numerically analyzed according to the diameter of primary air nozzle, equivalent ratio of burner, and equivalent ratio at center and side nozzle for development of multi-nozzle burner in the COG(Coke Oven Gas) rotary kiln for sintering iron ore. The results indicated that the flame length and $NO_x$ emission increase, as the diameter of primary air nozzle and equivalent ratio of burner increase. And according to the change of equivalent ratio at the center and the side of the nozzle, the flame length and average temperature in the kiln show very little change but the $NO_x$ emission shows obvious difference. In conclusion, the best design conditions which have satisfying flame length, average temperature and $NO_x$ emission are as follows: $D_2/D_1$ is 1.33, equivalent ratio of burner is 1.25 and center nozzle conditions are Rich.

Primary Invasive Mucinous Adenocarcinoma of the Lung: Prognostic Value of CT Imaging Features Combined with Clinical Factors

  • Tingting Wang;Yang Yang;Xinyue Liu;Jiajun Deng;Junqi Wu;Likun Hou;Chunyan Wu;Yunlang She;Xiwen Sun;Dong Xie;Chang Chen
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.652-662
    • /
    • 2021
  • Objective: To investigate the association between CT imaging features and survival outcomes in patients with primary invasive mucinous adenocarcinoma (IMA). Materials and Methods: Preoperative CT image findings were consecutively evaluated in 317 patients with resected IMA from January 2011 to December 2015. The association between CT features and long-term survival were assessed by univariate analysis. The independent prognostic factors were identified by the multivariate Cox regression analyses. The survival comparison of IMA patients was investigated using the Kaplan-Meier method and propensity scores. Furthermore, the prognostic impact of CT features was assessed based on different imaging subtypes, and the results were adjusted using the Bonferroni method. Results: The median follow-up time was 52.8 months; the 5-year disease-free survival (DFS) and overall survival rates of resected IMAs were 68.5% and 77.6%, respectively. The univariate analyses of all IMA patients demonstrated that 15 CT imaging features, in addition to the clinicopathologic characteristics, significantly correlated with the recurrence or death of IMA patients. The multivariable analysis revealed that five of them, including imaging subtype (p = 0.002), spiculation (p < 0.001), tumor density (p = 0.008), air bronchogram (p < 0.001), emphysema (p < 0.001), and location (p = 0.029) were independent prognostic factors. The subgroup analysis demonstrated that pneumonic-type IMA had a significantly worse prognosis than solitary-type IMA. Moreover, for solitary-type IMAs, the most independent CT imaging biomarkers were air bronchogram and emphysema with an adjusted p value less than 0.05; for pneumonic-type IMA, the tumors with mixed consolidation and ground-glass opacity were associated with a longer DFS (adjusted p = 0.012). Conclusion: CT imaging features characteristic of IMA may provide prognostic information and individual risk assessment in addition to the recognized clinical predictors.

Operating Characteristics of LLC Series Resonant Converter Using A LLT Transformer (LLT 변압기 적용 LLC 직렬공진컨버터 동작특성)

  • Lee, Hyun-Kwan;Huh, Dong-Young;Lee, Gi-Sik;Chung, Bong-Geun;Kang, Sung-In;Kim, Eun-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.409-416
    • /
    • 2006
  • Operating Characteristics of LLC Series resonant converter with a LLT(Inductor-Inductor-Transformer) transformer is presented. LLT transformer used to combine the inductor and transformer into one unit has the increased leakage inductance in the primary and secondary due to the winging method and the use of the gaped core. The increased leakage inductance in the primary and secondary of LLT transformer can be impacted on the DC voltage gain characteristics of LLC series resonant converter. In the paper, DC gain characteristics and the experimental results of the LLC series resonant converter with a LLT transformer are verified on the simulation based on the theoretical analysis and the 400W experimental prototype.

Distribution Characteristics and Background Air Classification of PM2.5 OC and EC in Summer Monsoon Season at the Anmyeondo Global Atmosphere Watch (GAW) Regional Station (안면도 기후변화감시소의 여름철 PM2.5 OC와 EC 분포 특성 및 배경대기 구분)

  • Ham, Jeeyoung;Lee, Meehye;Ryoo, Sang-Boom;Lee, Young-Gon
    • Atmosphere
    • /
    • v.29 no.4
    • /
    • pp.429-438
    • /
    • 2019
  • Organic carbon (OC) and elemental carbon (EC) in PM2.5 were measured with Sunset Laboratory Model-5 Semi-Continuous OC/EC Field Analyzer by NIOSH/TOT method at Anmyeondo Global Atmosphere Watch (GAW) Regional Station (37°32'N, 127°19'E) in July and August, 2017. The mean values of OC and EC were 3.7 ㎍ m-3 and 0.7 ㎍ m-3, respectively. During the study period, the concentrations of reactive gases and aerosol compositions were evidently lower than those of other seasons. It is mostly due to meteorological setting of the northeast Asia, where the influence of continental outflow is at its minimum during this season under southwesterly wind. While the diurnal variation of OC and EC were not clear, the concentrations of O3, CO, NOx, EC, and OC were evidently enhanced under easterly wind at night from 20:00 to 8:00. However, the high concentration of EC was observed concurrently with CO and NOx under northerly wind during 20:00~24:00. It indicates the influence of thermal power plant and industrial facilities, which was recognized as a major emission source during KORUS-AQ campaign. The diurnal variations of pollutants clearly showed the influence of land-sea breeze, in which OC showed good correlation between EC and O3 in seabreeze. It is estimated to be the recirculation of pollutants in land-sea breeze cycle. This study suggests that in general, Anmyeondo station serves well as a background monitoring station. However, the variation in meteorological condition is so dynamic that it is primary factor to determine the concentrations of secondary species as well as primary pollutants at Anmyeondo station.

Estimation of Spatial-Temporal Net Primary Productivity and Soil Carbon Storage Change in the Capital area of South Korea under Climate Change (기후변화에 따른 수도권 산림의 순일차생산량과 토양탄소저장량의 시공간적 변화 추정)

  • Kwon, Sun-Soon;Choi, Sun-Hee;Lee, Sang-Don
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.757-765
    • /
    • 2012
  • The purpose of this study was to estimate the spatial-temporal NPP(Net Primary Productivity) and SCS(Soil Carbon Storage) of forest ecosystem under climate change in the capital area of South Korea using Mapss-Century1 (MC1), one of Dynamic Global Vegetation Models (DGVMs). The characteristics of the NPP and SCS changes were simulated based on a biogeochemical module in this model. As results of the simulation, the NPP varies from 2.02 to 7.43 tC $ha^{-1}\;yr^{-1}$ and the SCS varies from 34.55 to 84.81 tC $ha^{-1}$ during 1971~2000 respectively. Spatial mean NPP showed a little decreasing tendency in near future (2021~2050) and then increased in far future (2071~2100) under the condition of increasing air temperature and precipitation which were simulated by the A1B climate change scenario of Intergovernmental Panel on Climate Change (IPCC). But it was estimated that the temporal change of spatial mean NPP indicates 4.62% increasing tendency in which elevation is over 150m in this area. However, spatial mean SCS was decreased in the two future periods under same climate condition.

Characteristic Analysis of Inductive Power Transfer System for PRT (소형궤도 열차용 유도 전력 전송 시스템 특성해석)

  • Min, Byung-Hun;Lee, Byung-Song
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.35-43
    • /
    • 2007
  • In this paper, the inductive power collector using electromagnetic induction for vehicle such as the PRT(Personal Rapid Transit) system is suggested and son ideas for power collector design to improve tile power transfer performance are presented. And also, the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency is shown. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system electrical power is transferred from a primary winding in the form of a coil or tract to one or more isolated pick-up coils that my relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, we will show you various characteristic of inductive power transfer system as double layer construction of secondary winding, which was divided in half to increase both output current and output voltage, a model of power collector and parallel winding structure, a model of concentration/ decentralization winding and the effects of parameter and operational frequency variation.

Staple Line Coverage with a Polyglycolic Acid Patch and Fibrin Glue without Pleural Abrasion after Thoracoscopic Bullectomy for Primary Spontaneous Pneumothorax

  • Hong, Ki Pyo;Kim, Do Kyun;Kang, Kyung Hoon
    • Journal of Chest Surgery
    • /
    • v.49 no.2
    • /
    • pp.85-91
    • /
    • 2016
  • Background: This study was conducted to determine the efficacy of staple line coverage using a polyglycolic acid patch and fibrin glue without pleural abrasion to prevent recurrent postoperative pneumothorax. Methods: A retrospective analysis was carried out of 116 operations performed between January 2011 and April 2013. During this period, staple lines were covered with a polyglycolic acid patch and fibrin glue in 58 cases (group A), while 58 cases underwent thoracoscopic bullectomy only (group B). Results: The median follow-up period was 33 months (range, 22 to 55 months). The duration of chest tube drainage was shorter in group A (group A $2.7{\pm}1.2day$ vs. group B $3.9{\pm}2.3day$, p=0.001). Prolonged postoperative air leakage occurred more frequently in group B than in group A (43% vs. 19%, p=0.005). The postoperative recurrence rate of pneumothorax was significantly lower in group A (8.6%) than in group B (24.1%) (p=0.043). The total cost of treatment during the follow-up period, including the cost for the treatment of postoperative recurrent pneumothorax, was not significantly different between the two groups (p=0.43). Conclusion: Without pleural abrasion, staple line coverage with a medium-sized polyglycolic acid patch and fibrin glue after thoracoscopic bullectomy for primary spontaneous pneumothorax is a useful technique that can reduce the duration of postoperative pleural drainage and the postoperative recurrence rate of pneumothorax.