• Title/Summary/Keyword: Primary Air

Search Result 875, Processing Time 0.023 seconds

Pneumothorax

  • Choi, Won-Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.3
    • /
    • pp.99-104
    • /
    • 2014
  • Pneumothorax-either spontaneous or iatrogenic-is commonly encountered in pulmonary medicine. While secondary pneumothorax is caused by an underlying pulmonary disease, the spontaneous type occurs in healthy individuals without obvious cause. The British Thoracic Society (BTS, 2010) and the American College of Chest Physicians (ACCP, 2001) published the guidelines for pneumothorax management. This review compares the diagnostic and management recommendations between the two societies. Patients diagnosed with primary spontaneous pneumothorax (PSP) may be observed without intervention if the pneumothorax is small and there are no symptoms. Oxygen therapy is only discussed in the BTS guidelines. If intervention is needed, BTS recommends a simple aspiration in all spontaneous and some secondary pneumothorax cases, whereas ACCP suggests a chest tube insertion rather than a simple aspiration. BTS and ACCP both recommend surgery for patients with a recurrent pneumothorax and persistent air leak. For patients who decline surgery or are poor surgical candidates, pleurodesis is an alternative recommended by both BTS and ACCP guidelines. Treatment strategies of iatrogenic pneumothorax are very similar to PSP. However, recurrence is not a consideration in iatrogenic pneumothorax.

Series-parallel resonant converter using a contactless power supply for the efficiency improvement (효율 개선을 위한 직${\cdot}$병렬 공진컨버터 적용 비접촉 전원)

  • Kong Y.S.;Lee H.K.;Kim E.S.;Cho J.G.;Kim J.M.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.45-48
    • /
    • 2004
  • To improve the efficiency characteristics in the resonant converter using the contact-less power supply with the large air-gap and the long primary winding, this paper suggests the three-level series-parallel resonant converter(SPRC). The voltage gain characteristics of the proposed converter have the unit gain in a resonance frequency point of the series and parallel, and input voltage and current in the primary of SPRC are always In phase for the all equivalent load resistance because of the parallel resonant tank of the high impedance. The results are verified on the simulation based on the theoretical analysis and the 4kW experimental prototype.

  • PDF

A Case of Large Mass on Both Lung (양측폐에 발생한 종괴)

  • Han, Min-Soo;Kang, Hong-Mo;Yoo, Jee-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.234-237
    • /
    • 1998
  • A 64-year-old male was admitted due to weight loss of 5kg during a month. Chest X-ray showed two large, lobulated masses on both lower lobe. Chest CT showed ill-defined, multilobulated mass on left lower lobe and irregular, relatively homogenous mass with air-bronchogram on right lower lobe. Left lower lobectomy and right lower lobectomy was performed sequentially with three months interval. Microscopic findings showed squamous cell carcinoma of both mass. It was thought that this patient had synchronous double primary lung cancer.

  • PDF

An Experimental Study on the Combustion Characteristics with Hydrogen Enrichment in a Dump Combustor (수소 혼합에 따른 덤프 연소기내의 연소 특성에 관한 실험적 연구)

  • Kim, Dae-Hee;Hong, Jung-Goo;Shin, Hyun-Dong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2977-2983
    • /
    • 2008
  • The combustion characteristics of a partially premixed flame in a dump combustor were studied to determine the effects of hydrogen enrichment in propane. Bluff-body was used for flame stabilization. Fuel mixtures containing a hydrogen mole fraction ranging from 0.1 to 0.5 were burnt at ambient pressure within a quartz chamber. Tests were carried out keeping the total reactant flow rate by adjusting the fuel and air flow rates. The fluctuations of pressure were measured by piezoelectric pressure sensor. The instantaneous flame structure and OH chemiluminescence images were described by High-speed Intensified Charged Coupled Device (HICCD) camera and Intensified Charged Coupled Device (ICCD) camera. The present results show that hydrogen enrichment in fuel changed the location of primary reaction zone from inner recirculation zone to turbulent shear layer and pressure signal. The reason is that chemical aspects take precedence over flow aspects in the hydrogen-enriched flame.

  • PDF

One-Ampere Conductor Method for Tubular Linear Induction Motor for Size Reduction of Primary Iron Core

  • Lee, Byeong-Hwa;Kim, Kyu-Seob;Kwon, Soon-O;Sun, Tao;Hong, Jung-Pyo;Lee, Jung-Ho
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.46-50
    • /
    • 2011
  • This paper presents size reduction of primary iron core for tubular linear induction motor by improved winding configuration. Using one-ampere conductor method, magnetic field analysis of tubular linear induction motor for size reduction is conducted. Size reduction and improvement of air gap flux distribution is achieved by improved winding configuration, and analysis results are verified by finite element analysis (FEA) and experiments.

A Study on Chemical Characteristics of Aerosol Composition at West Inflow Regions in the Korean Peninsula I. Characteristics of PM Concentration and Chemical Components (한반도 서부유입권역에서 대기 중 에어로졸 성분의 화학적 특성 연구 I. PM 농도 및 화학 성분 특성)

  • Choi, Jin-Soo;Kim, Jeong-Ho;Lee, Tae-Hyoung;Choi, Yong-Joo;Park, Tae-Hyun;Oh, Jun;Park, in-Soo;Ahn, Joon-Young;Jeon, Ha-Eun;Koo, Youn-Seo;Kim, Shin-Do;Hong, You-Deog;Hong, Ji-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.469-484
    • /
    • 2016
  • HR-ToF-AMS was applied for a seasonal and size-distributional measurements for inorganic ($SO{_4}^{2-}$, $NO_3{^-}$, $NH_4{^+}$, $Cl^-$) and organic components in Baegryung Island Super Site. The average concentration of $PM_{1.0}$ remarks $12.9{\mu}g/m^3$ while $14.5{\mu}g/m^3$ in Spring time, $14.2{\mu}g/m^3$ in Winter, $13.1{\mu}g/m^3$ in Summer and $9.86{\mu}g/m^3$ in Autumn. The mass of measured $PM_{1.0}$ shows 54.6% of $PM_{2.5}$ which is similar to those of Beijing and Lanzhou, China. The highest portion of Chemical composition is $SO{_4}^{2-}$ marking 41.0%, 31.8% by organics, 13.5% by $NH_4{^+}$, 12.8% by $NO_3{^-}$ and 1% by $Cl^-$. In every seasons, except winter, $SO{_4}^{2-}$ remarks the highest level, organic components take place the highest in winter time. The size-distribution of $PM_{1.0}$ components scattered at accumulation mode of 200 nm~800 nm which means the influence of primary emission is low. In case of air stream from the industrialized area of Sandung, Shanghai, China, the concentrations of such components were distributed a bit higher.

Relationship Between Ozone Concentrations and Affecting factors in Seosan City of Korea (충남 서산지역 대기 중의 오존농도와 그 영향인자와의 관련성)

  • Kim, Jun-Kyeom;Jeong, Yong-Jun;Cho, Young-Chae
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.78-88
    • /
    • 2003
  • This study was conducted to investigate the relation between ozone concentration and the affecting factors in Seosan City of Korea from Jan. 2002 to Dec. 2002. We analyzed the air pollutants such as NO$_2$, PM$_{10} $,SO$_2$, CO and the meteorological factors including solar radiation, air temperature, wind speed and relative humidity. The analytical data were taken statistics by SPSS method. The results were as follows: The seasonal average concentration of ozone were detected 35.0 ppb in Spring, 25.4 ppb in Summer, 23.5 ppb in Autumn and 21.4 ppb in Winter. So the difference of concentrations showed significantly in statistics. The hourly ozone concentration in a day was increased at 7-9 AM, peaked at 3-4 PM. The correlation coefficients was negative to ozone concentration and NO$_2$, SO$_2$, CO, relative humidity, but positive to solar radiation, air temperature, wind speed. With stepwise multiple regression analysis on the 8 factors such as NO$ _2$, PMSO$_{10}$,SO$_2$, CO, solar radiation, air temperature, wind speed and relative humidity, the seasonal primary factors were air temperature in spring, relative humidity in summer and solar radiation in autumn and winter. The above results suggest that ozone is the secondary pollutant by photochemical reaction as the concentration of ozone was increased with the raise of solar radiation.

A Commentary on Air Pollution Monitoring Programs in Korea

  • Ghim, Young-Sung;Kim, Jin-Young;Shim, Shang-Gyoo;Moon, Kill-Choo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E1
    • /
    • pp.21-28
    • /
    • 2002
  • Air quality issues in Korea rapidly changed at the beginning of the 1990s from primary to secondary pollutants starting in Seoul, the capital of Korea. The present frame of national air pollution monitoring networks was established between the end of the 1980s and the beginning of the 1990s. Background monitoring was initiated in the middle of the 1990s in response to increasing public concern about the long-range transport of air pollutants. Apart from the national monitoring, both routine and intensive measurements of fine particles have been made for research purposes since the middle of the 1990s at several background sites. However, air pollution monitoring in urban areas for other purposes was relatively scarce as national monitoring has been concentrated in these areas. Although ozone pollution has become a significant issue in major metropolitan areas every summer, only a little information on ozone precursors is available. During the past few years, the number of national monitoring stations has greatly increased. The government has a plan to gradually expand monitoring items as well as stations. It is anticipated that highly detailed information on both photochemical reactants and products will be available within the next several years. More emphasis will be placed on toxic substances based on risk assessment in monitoring for both research and policy making.

Electrochemical properties of AZ31, AZ61 magnesium alloy electrodes for eco-friendly Magnesium-air battery (친환경 마그네슘-공기 전지용 AZ31, AZ61 마그네슘 합금 전극의 전기화학적 특성)

  • Choi, Weon-Kyung
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.5
    • /
    • pp.17-22
    • /
    • 2021
  • Eco-friendly magnesium-air battery is a kind of metal-air battery known as a primary battery with a very high theoretical discharge capacity. This battery is also called a metal-fuel cell from the viewpoint of using oxygen in the atmosphere as a cathode active material and magnesium alloy as a fuel. Since battery performance is determined by the properties of the magnesium alloy used as a anode, more research and development of the magnesium alloy electrode as a anode material are required in order to commercialize it as a high-performance battery. In this study, the commercialized magnesium alloys(AZ31, AZ61) were selected and then electrochemical measurements and discharge test were conducted. Electrochemical properties of magnesium alloys were investigated by OCP changes, Tafel parameters and CV measurement, and the feasibilities of AZ61 alloy with excellent discharge capacity(1410mAhg-1) as electrode materials were evaluated through CC discharge experiments.

Study of oxidation behavior and tensile properties of candidate superalloys in the air ingress simulation scenario

  • Bin Du;Haoxiang Li;Wei Zheng;Xuedong He;Tao Ma;Huaqiang Yin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.71-79
    • /
    • 2023
  • Air ingress incidents are major safety accidents in very-high-temperature reactors (VHTRs). Air containing a high volume fraction of oxygen may cause severe oxidation of core components at the VHTR, especially for the significantly thin alloy tube wall in the intermediate heat exchanger (IHE). The research objects of this study are Inconel 617 and Incoloy 800H, two candidate alloys for IHE in VHTR. The air ingress accident scenario is simulated with high-temperature air flow at 950 ℃. A continuous oxide scale was formed on the surfaces of both the alloys after the experiment. Because the oxide scale of Inconel 617 has a loose structure, whereas that of Incoloy 800H is denser, Inconel 617 exhibited significantly more severe internal oxidation than Incoloy 800H. Further, Inconel 617 showed a significant decrease in ultimate tensile strength and plasticity after aging for 200 h, whereas Incoloy 800H maintained its tensile properties satisfactorily. Through control experiment under vacuum, we preliminarily concluded that serious internal oxidation is the primary reason for the decline in the tensile properties of Inconel 617.