• 제목/요약/키워드: Primary Air

검색결과 875건 처리시간 0.026초

서울시 대기중 오존의 오염도와 그 영향인자 분석 (An Analysis of Influencing Factors on Ozone Concentration in the Ambient Air in Seoul)

  • 정용;장재연;권숙표
    • 한국대기환경학회지
    • /
    • 제2권1호
    • /
    • pp.73-79
    • /
    • 1986
  • This study is carried out to determine the concentration of the ozone and the factors affecting the variation of ozone concentration in the ambient air in Seoul. The one-hour average concentration of ozone $(O_3)$, sulfur dioxide $(SO_2)$, nitrogen oxides (NO and $NO_2$), suspended particulate (TSP), carbon monoxide (CO) and non-methane hydrocarbon (NMHC) at 5 sites in Seoul measured from September to October in 1983 and 1984 were analysed statistically along with meteorological data for the same period. The results were as follows; 1. The average concentrations of ozone at 5 sites during the period ranged from 3.3 to 9.1 ppb, they were below 20 ppb of the ambient air quality standard of Korea. 2. The maximum hourly concentration of ozone occurred between 2 and 3 p.m. in a day and concentration at night were very low but higher concentrations were observed at around 4 a.m. 3. The concentration ratio between NO and $NO_2$ in Seoul was relatively lower than that for the cities of foreign countries reported so far. 4. The ozone concentration has negative correlationships with the concentration of other primary pollutants$(SO_2, NO, NO_2, CO and NMHC)$ in simple regression analyses. 5. The ozone concentration was positively correlated to wind speed, temperature and insolation intensity but negatively correlated to relative humidity. 6. Stepwise multiple regression analysis of the ozone concentration to the pollutants and meteorological factors indicate that insolation intensity and $[NO_2]/[NO]$ were the primary influencing factors. 7. The three factors of insolation intensity, $[NO_2]/[NO] and NO_2$ concentration had a significant combined effect on the ozone concentration $(r^2 = 0.47-0.57)$.

  • PDF

파라메트릭 어레이를 이용한 공기 중 디지털 통신 연구 (A Study on Digital Communication in Air Using Parametric Array)

  • 제엽;이재일;이종현;문원규
    • 한국음향학회지
    • /
    • 제28권8호
    • /
    • pp.768-773
    • /
    • 2009
  • 본 논문에서는 파라메트릭 어레이를 이용한 공기 중 디지털 통신의 특성을 측정해 보았다. 2차 오더의 비선형 현상인 파라메트릭 어레이를 구현하기 위하여, 고출력, 고효율의 음파 발생이 가능한 요철 트랜스듀서가 사용되었다. 1차 음파 (primary wave)의 주파수는 트랜스듀서 공진 주파수에 맞추어 83 kHz, 122 kHz 로 결정하였고, 이를 통해 발생되는 39 kHz의 차음 (difference frequency wave)을 통신 신호로 이용하였다. 통신 변조방법으로 On-Off Keying 방식을 이용하였다. 실험은 파라메트릭 어레이를 이용한 디지털 통신의 특성을 측정하기 위하여 파형 분석을 하였고, 거리, 각도에 따른 SNR을 측정해 보았다. 실험 결과 파라메트릭 어레이를 이용한 디지털 통신은 3m이내의 근거리 영역에서 적합함을 알 수 있었고, 빔폭 (-3 dB)은 $14^{\circ}$로 측정되어 고지향성 통신이 가능함을 확인하였다. 위의 실험 결과를 통해 파라메트릭 어레이를 이용한 공기 중 음향 통신에 대한 가능성을 확인하였고, 고지향성 통신 특성은 다중경로 문제나 보안 문제에 강점이 있을 것으로 판단된다.

Temporal distribution, influencing factors and pollution sources of urban ambient air quality in Nanchong, China

  • Zhou, Hong;Li, Youping;Liu, Huifang;Fan, Zhongyu;Xia, Jie;Chen, Shanli;Zheng, Yuxiang;Chen, Xiaocui
    • Environmental Engineering Research
    • /
    • 제20권3호
    • /
    • pp.260-267
    • /
    • 2015
  • The $PM_{10}$, $SO_2$ and $NO_2$ mass concentrations were obtained over five years from monitoring stations across Nanchong, a southwest city in China. Changes in urban air quality over time, as well as the factors influencing that change, were evaluated based on air pollutant concentrations, the Air Pollution Index (API), and the Comprehensive Pollution Index (P). The results showed that the total annual mean $PM_{10}$, $SO_2$ and $NO_2$ concentrations over the five years studied were $61.1{\pm}1.1$, $45.0{\pm}3.9$ and $34.9{\pm}4.9{\mu}g{\cdot}m^{-3}$, respectively. The annual mean concentrations displayed a generally decreasing trend; lower than the annual mean second-level air quality limit. Meanwhile, the annual mean API values were in a small range of 52-53, the air quality levels were grade II, and P values were 1.06-1.21 less than the slight level ($P{\leq}1.31$). Total monthly mean $PM_{10}$, $SO_2$, $NO_2$ concentrations, and API and P values were consistently higher in winter and spring than during autumn and summer. The results of a correlation analysis showed that temperature and pressure were the major meteorological factors influencing pollution levels. Pollution sources included industrial coal and straw burning, automobiles exhaust and road dust, fireworks, and dust storms.

국지 기상 특성에 따른 군산, 대구 및 포항의 대기질의 일변화 (Variations of Air Quality in Kunsan, Taegu, and Pohang due to the Characteristics of Local Weather)

  • 서기수;윤일희
    • 한국환경과학회지
    • /
    • 제6권6호
    • /
    • pp.613-628
    • /
    • 1997
  • Diurnal variations of air quality due to the characteristic features of local weather phenomena over Kunsan, Taegu, and Pohang are analyzed using various synoptic wand fields and the characteristics of local weather during the period of 1990 to 1992. The air pollutants analyzed are sulfur dioxide($SO2_$), nitrogen dioxide($NO_2$), and oxidants ($0_3$). The synoptic wind fields estimated at over the 850 hPa geopotential height are divided in terms of four wand directions and two wand speed categories for each season. The synoptic weather conditions are also classified Into two categories depending on the 850 hPa cloud amounts. The present study shows that the $SO_2$ concentration over Kunsan, and Taegu was maximum at the two or three hours after sunrise and second primary was three or flour hours after sunset. On the other hand, Its concentration over Kunsan was malnmum at 1900 LST or 2000 LST The $O_3$ concentration over the three cities shows Its mapdmum In the afternoon when the solar radiation is strong. The $NO_2$ concentration over Kansan shows in reverse proportion to the $O_3$ concentration over the Kunsan.

  • PDF

외부공기 유입관을 이용한 컴퓨터 냉각시스템의 효율향상에 관한 연구 (A Primary Study on the Enhancement of Efficiency in the Computer Cooling System using Entrance Tube of Outer Air)

  • 김순호;김문환
    • 동력기계공학회지
    • /
    • 제13권4호
    • /
    • pp.56-61
    • /
    • 2009
  • In recent years, since the continuing increase in the capacity in personal computer such as the optimal performance, high quality and high resolution image, the computer system's components produce large amounts of heat during operation. This study analyzes and investigates the ability and efficiency of a cooling system inside a computer by means of central processing unit (CPU) and power supply cooling fan. This research was conducted to enhancement of efficiency of the cooling system inside the computer by making a structure which produces different air pressures in an air inflow tube. Consequently, when temperatures of the CPU and room inside computer were compared with a general personal computer, temperatures of the tested CPU, the room and the heat sink were as low as $5^{\circ}C$, $2.5^{\circ}C$ and $7^{\circ}C$ respectively. In addition to, revolution per minute (RPM) was shown as low as 250 after 1 hour operation. This research explored the possibility of enhancing the effective cooling of high-performance computer systems.

  • PDF

흡수식 냉온수기용 저 NOx 가스버너 개발 (Development of Low NOx Gas Burner Absorption Chiller/Heater Unit)

  • 최정환;오신규
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.277-283
    • /
    • 1995
  • For the development of low NO$_{x}$ gas burners aimed for absorption chiller/heater unit, three proto type burners of different capacity (265000, 498000, and 664000 kcal/h) have been manufactured through a combustion method of step-by-step air injection. In order to characterize the overall features of the flame and the properties of the emission gas, the temperature of the flame and the concentration of NO$_{x}$ and CO were determined. The main factors in the design of burners (the area of primary air injection, the diameter of secondary air injection hole, fuel nozzle diameter) were observed to increase linearly with the scale-up of burner capacity. The flame temperature profiles of the burners were observed to be almost similar, irrespective of their capacity. However, as their capacity increased, the flame temperature slightly increased and the hot region of the flames moved to ward the flame tip along with the expansion to the direction of radius. From the proto type units, the amount of their NO$_{x}$ emission was determined to be around 25 - 30 vppm(3% )$_{2}$) and the CO emission was less than 19 vppm (3% $O_{2}$).TEX>).

실험실 규모 순환유동층 연소로에서 2차공기 주입이 냉간유동에 미치는 영향 (Secondary Air Injection Effect on Cold Flow in a Laboratory-scale Circulating Fluidized Bed Combustor)

  • 장석돈;라승혁;황정호;강경태
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.217-228
    • /
    • 2000
  • Circulating Fluidized Bed Combustor(CFBC) has been used for the incineration of waste sewage sludge and for the power generation. In this study hydrodynamic characteristics of two phase flow have been studied in a riser section of CFBC. A lab-scale riser is designed and SiC (Geldart type B) is used for solid particles. Experiments are performed by controlling the fluidization parameters including superficial velocity and secondary air to primary air ratio for determination of solid holdup profiles in the riser. Superficial velocities of each fluidization regime are well agreed with results predicted by a theoretical model. The results show that the axial solid holdup distributions calculated by measuring differential static pressures in the riser are found to show a basic profile described by a simple exponential function. Our flow regime during experiments mainly belongs to fast fluidization regime for particle size of 300${\mu}m$. As the SA/PA ratio increases, solid holdup in the lower dense region of the riser increases.

  • PDF

소듐냉각고속로 잔열제거계통 강제대류 소듐-공기 열교환기의 구조개념 설계 (Structural design concept of the forced-draft sodium-to-air heat exchanger in the decay heat removal system of PGSFR)

  • 김낙현;이사용;김성균
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.78-84
    • /
    • 2016
  • The FHX (Forced-draft sodium-to-air Heat Exchanger) employed in the ADHRS (active decay heat removal system) is a shell-and-tube type counter-current flow heat exchanger with M-shape finned-tube arrangement. Liquid sodium flows inside the heat transfer tubes and atmospheric air flows over the finned tubes. The unit is placed in the upper region of the reactor building and has function of dumping the system heat load into the final heat sink, i.e., the atmosphere. Heat is transmitted from the primary cold sodium pool into the ADHRS sodium loop via DHX (decay heat exchanger), and a direct heat exchange occurs between the tube-side sodium and the shell-side air through the FHX tube wall. This paper describes the DHRS and the structural design of the FHX.

인천지역 공공 노인복지시설의 건축조건과 실내공기질에 대한 실태조사 및 분석 (An Investigation and Analysis into the Architectural Conditions and Indoor Air Quality of Senior Citizens Public Welfare Institution in Incheon)

  • 강승아;신성식;김용식
    • KIEAE Journal
    • /
    • 제9권2호
    • /
    • pp.59-64
    • /
    • 2009
  • The senior citizens population and welfare institution for them is increased. The senior citizens in welfare institution spend a long time in indoor and their health is greatly affected by the indoor environment. Therefore, the indoor environment of senior citizens welfare institution is very important. This study presents some primary data based on the survey of architectural conditions and the measurements of indoor air quality for senior citizens welfare institution. According to characteristic of region, six of Incheon Area's senior citizens public welfare institution are selected. An investigation and analysis into architectural conditions and indoor air quality including temperature, humidity, CO, $CO_2$, PM10, HCHO, TVOC are conducted. The temperature, humidity and $CO_2$ concentration is some high. The HCHO concentration is very high. The indoor flooring and furniture materials highly impacts on the concentration of HCHO and TVOC.

컬러TV 제품의 오염물질 방출특성 평가방법과 관리 기준안 설정에 대한 연구 (Evaluation Methods for Chemical Emissions from TV Products and Establishing Criteria for the Perceived Indoor Air Quality)

  • 강효석;윤동원;이윤규
    • 설비공학논문집
    • /
    • 제22권5호
    • /
    • pp.304-313
    • /
    • 2010
  • During recent years, various studies have demonstrated that indoor chemical pollution causes health problem and also negatively affect the performance of work by occupants. Building materials have been concerned as indoor chemical sources. Some of guidelines and certification system has been developed and resulted as dramatic decrease of harmful indoor chemicals such as formaldehyde and volatile organic compounds. Also, Home furniture and electrical devices has been concerned as one the primary influence the indoor chemical concentration in residential spaces. It is found that various kinds of electric home appliances have a significant source of chemical emission in indoor environments. In this study, the methodologies of detecting harmful chemicals from various kinds of products has been developed with large chamber measurement system and suggest some of the evaluation method for the chemicals from the home appliances as TV sets.