• 제목/요약/키워드: Preventive diagnostic system

검색결과 76건 처리시간 0.023초

변압기 예방진단을 위한 유중가스 전문가 시스템 구축 연구 (Development of the Preventive Diagnostic Expert System of Gas in Oil for Power Transformer)

  • 최인혁;권동진;정길조;선종호;김진곤;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1019-1021
    • /
    • 1999
  • In this paper, we describe the design and appliance of the preventive diagnostic expert system of gas in oil for power transformer. This expert system is developed to use expert system development tool; Element Expert (NEURON DATA Inc.) Analysis is developed by four diagnose methods. In first, the standard of KEPCO is applied. It classifies the state of transformer by four level: Normal, warning, abnormal and danger. And the others are gas pattern methods, IEC code method, and Dornen & Roger Ratio method and applied later. These latter methods analyse the cause of result. Inference engine was designed with Element Expert. In last, we operate the system with sample data and we can obtain the correctly inferred result for the state of transformer.

  • PDF

변전소 예방진단시스템 모니터링 프로그램 개발 (Development of a Monitoring Program for the Substation Preventive Diagnostic System)

  • 권동진;최인혁;신한철;이호진;정용준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1623-1625
    • /
    • 2001
  • This paper describes a monitoring program for a substation preventive diagnostic system. The monitoring program announces the condition of the transformer and GIS like normal, warning, abnormal and danger from the absolute value of data or change trend to user. The developed system is operating in 345kV U-Ryung substation for performance and environment tests.

  • PDF

Prevalence of Depressive Disorder of Outpatients Visiting Two Primary Care Settings

  • Jo, Sun-Jin;Yim, Hyeon Woo;Jeong, Hyunsuk;Song, Hoo Rim;Ju, Sang Yhun;Kim, Jong Lyul;Jun, Tae-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • 제48권5호
    • /
    • pp.257-263
    • /
    • 2015
  • Objectives: Although the prevalence of depressive disorders in South Korea's general population is known, no reports on the prevalence of depression among patients who visit primary care facilities have been published. This preliminary study was conducted to identify the prevalence of depressive disorder in patients that visit two primary care facilities. Methods: Among 231 consecutive eligible patients who visited two primary care settings, 184 patients consented to a diagnostic interview for depression by psychiatrists following the Diagnostic and Statistical Manual of Mental Disorders-IV criteria. There were no significant differences in sociodemographic characteristics such as gender, age, or level of education between the groups that consented and declined the diagnostic examination. The prevalence of depressive disorder and the proportion of newly diagnosed patients among depressive disorder patients were calculated. Results: The prevalence of depressive disorder of patients in the two primary care facilities was 14.1% (95% confidence interval [CI], 9.1 to 19.2), with major depressive disorder 5.4% (95% CI, 2.1 to 8.7), dysthymia 1.1% (95% CI, 0.0 to 2.6), and depressive disorder, not otherwise specified 7.6% (95% CI, 3.7 to 11.5). Among the 26 patients with depressive disorder, 19 patients were newly diagnosed. Conclusions: As compared to the general population, a higher prevalence of depressive disorders was observed among patients at two primary care facilities. Further study is needed with larger samples to inform the development of a primary care setting-based depression screening, management, and referral system to increase the efficiency of limited health care resources.

모터펌프의 지능형 진단시스템 구현에 관한 연구 (A Study on the Implementation of Intelligent Diagnosis System for Motor Pump)

  • 안재현;양오
    • 반도체디스플레이기술학회지
    • /
    • 제18권4호
    • /
    • pp.87-91
    • /
    • 2019
  • The diagnosis of the failure for the existing electrical facilities was based on regular preventive maintenance, but this preventive maintenance was limited in preventing a lot of cost loss and sudden system failure. To overcome these shortcomings, fault prediction and diagnostic techniques are critical to increasing system reliability by monitoring electrical installations in real time and detecting abnormal conditions in the facility early. As the performance and quality deterioration problem occurs frequently due to the increase in the number of users of the motor pump, the purpose is to build an intelligent control system that can control the motor pump to maximize the performance and to improve the quality and reliability. To this end, a vibration sensor, temperature sensor, pressure sensor, and low water level sensor are used to detect vibrations, temperatures, pressures, and low water levels that can occur in the motor pump, and to build a system that can identify and diagnose information to users in real time.

예방진단기술을 이용한 지능형 GIS 감시시스템에 관한 연구 (A Study on a Intelligent GIS Monitoring System using the Preventive Diagnostic Technology)

  • 박기영;이종하;조숙진;최형기;정의붕
    • 전자공학회논문지
    • /
    • 제51권6호
    • /
    • pp.244-251
    • /
    • 2014
  • 본 논문에서, 가스절연개폐장치(GIS)의 정상상태와 비정상상태에 대해 예방진단기술을 이용하여 자세하게 서술하였다. 이 기술은 지능형 GIS 감시시스템에 의해 저장된 GIS의 데이터의 분석과 진단에 근거한다. GIS음의 파형은 방전과 자체내의 코로나 방전음에 의해 발생되는 것으로 잡음과 비슷하다. 그러므로, 본 논문에서, GIS음의 정상 상태와 비정상 상태로 분류하는데, 정상과 비정상 상태를 레벨교차율(LCR)과 스펙트로그램 에너지비율로 이용하여 구분하였다.

Environmental Mercury and Its Toxic Effects

  • Rice, Kevin M.;Walker, Ernest M. Jr.;Wu, Miaozong;Gillette, Chris;Blough, Eric R.
    • Journal of Preventive Medicine and Public Health
    • /
    • 제47권2호
    • /
    • pp.74-83
    • /
    • 2014
  • Mercury exists naturally and as a man-made contaminant. The release of processed mercury can lead to a progressive increase in the amount of atmospheric mercury, which enters the atmospheric-soil-water distribution cycles where it can remain in circulation for years. Mercury poisoning is the result of exposure to mercury or mercury compounds resulting in various toxic effects depend on its chemical form and route of exposure. The major route of human exposure to methylmercury (MeHg) is largely through eating contaminated fish, seafood, and wildlife which have been exposed to mercury through ingestion of contaminated lower organisms. MeHg toxicity is associated with nervous system damage in adults and impaired neurological development in infants and children. Ingested mercury may undergo bioaccumulation leading to progressive increases in body burdens. This review addresses the systemic pathophysiology of individual organ systems associated with mercury poisoning. Mercury has profound cellular, cardiovascular, hematological, pulmonary, renal, immunological, neurological, endocrine, reproductive, and embryonic toxicological effects.

Effectiveness of the Microlux/DLTM Chemiluminescence Device in Screening of Potentially Malignant and Malignant Oral Lesions

  • Ibrahim, Suzan Seif;Al-Attas, Safia Ali;Darwish, Zeinab Elsayed;Amer, Hala Abbas;Hassan, Mona Hassan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권15호
    • /
    • pp.6081-6086
    • /
    • 2014
  • Background: To evaluate the effectiveness of Microlux/DL with and without toluidine blue in screening of potentially malignant and malignant oral lesions. Materials and Methods: In this diagnostic clinical trial clinical examination was carried out by two teams: 1) two oral medicine consultants, and 2) two general dentists. Participants were randomly and blindly allocated for each examining team. A total of 599 tobacco users were assessed through conventional oral examination (COE); the examination was then repeated using Microlux/DL device and toluidine blue. Biopsy of suspicious lesions was performed. Also clinicians opinions regarding the two tools were obtained. Results: The sensitivity and, specificity and positive predictive value (PVP) of Microlux/DL for visualization of suspicious premalignant lesions considering COE as a gold standard (i.e screening device) were 94.3%, 99.6% and 96.2% respectively, while they were 100%, 32.4% and 17.9% when considering biopsy as a gold standard. Moreover, Microlux/DL enhanced detection of the lesion and uncovered new lesions compared to COE, whereas it did not alter the provisional clinical diagnosis, or alter the biopsy site. On the other hand, adding toluidine blue dye did not improve the effectiveness of the Microlux/DL system. Conclusions: The Microlux/DL seems to be a promising adjunctive screening device.

고혈압 건강진단의 비용분석 (Cost analysis of hypertension screening program)

  • 박은철;유승흠
    • Journal of Preventive Medicine and Public Health
    • /
    • 제22권3호
    • /
    • pp.380-388
    • /
    • 1989
  • To evaluate the costs of the hypertension screening program of the Korea Medical Insurance Corporation, the records of the screening examinations were used. The sample size was 49,983 of the 906,554 people insured by the Corporation and was obtained by two-stage stratification random sampling. The alternatives for efficiency of the screening program, which were divided into three categories : modification of the screening test package, application of other hypertension diagnostic criteria, and selective approach of tested groups by age, were evaluated according to the cost per patient detected. The results of this study were as follows In the hypertension screening system, the cost per patient detected was Won 30,883. The most nonsensitive test for hypertension detection was ophthalmoscopy, which was examined during the second stage of screening. If the ophthalmoscope examination was excluded, olny one person was not detected, which was 0.2% of detected persons, and the cost per patient detected decreased to Won 28,098. The most efficient modification of the screening test package was measurement of blood pressure through the first and second stages of screening. The cost per patient detected by this modification was Won 24,408. The application of other diagnostic critera, which were more restricted criteria, increased the cost per patient detected by 3.7%-6.7%. The cost per patient detected were Won 170,582 for persons less than 39 years old, Won 20,032 for persons 40 to 59 years old, and Won 8,675 for persons 60 years old and over. In conclusion, the best alternative suggested with respect to efficiency and practical application excluded the ophthalmoscope examination of second stage screening and restricted the target population to persons greater than 40 years old. The application of this alternative decreased 54.9% of the screening costs and the cost per patient detected was Won 15,222. This study was limited in that measurement of effectivenes was not of the ultimate goal of screening, which is decreasing morbidity and mortality, but was of disease detection as the short-term objective.

  • PDF

의료보험자료 상병기호의 정확도 추정 및 관련 특성 분석 -법정전염병을 중심으로- (Estimation of Disease Code Accuracy of National Medical Insurance Data and the Related Factors)

  • 신의철;박용문;박용규;김병성;박기동;맹광호
    • Journal of Preventive Medicine and Public Health
    • /
    • 제31권3호
    • /
    • pp.471-480
    • /
    • 1998
  • This study was undertaken in order to estimate the accuracy of disease code of the Korean National Medical Insurance Data and disease the characteristics related to the accuracy. To accomplish these objectives, 2,431 cases coded as notifiable acute communicable diseases (NACD) were randomly selected from 1994 National Medical Insurance data file and family medicine specialists reviewed the medical records to confirm the diagnostic accuracy and investigate the related factors. Major findings obtained from this study are as follows : 1. The accuracy rate of disease code of NACD in National Medical Insurance data was very low, 10.1% (95% C.I. : 8.8-11.4). 2. The reasons of inaccuracy in disease code were 1) claiming process related administrative error by physician and non-physician personnel in medical institutions (41.0%), 2) input error of claims data by key punchers of National Medical Insurer (31.3%) and 3) diagnostic error by physicians (21.7%). 3. Characteristics significantly related with lowering the accuracy of disease code were location and level of the medical institutions in multiple logistic regression analysis. Medical institutions in Seoul showed lower accuracy than those in Kyonngi, and so did general hospitals, hospitals and clinics than tertiary hospitals. Physician related characteristics significantly lowering disease code accuracy of insurance data were sex, age group and specialty. Male physicians showed significantly lower accuracy than female physicians; thirties and fortieg age group also showed significantly lower accuracy than twenties, and so did general physicians and other specialists than internal medicine/pediatric specialists. This study strongly suggests that a series of policies like 1) establishment of peer review organization of National Medical Insurance data, 2) prompt nation-wide expansion of computerized claiming network of National Medical Insurance and 3) establishment and distribution of objective diagnostic criteria to physicians are necessary to set up a national disease surveillance system utilizing National Medical Insurance claims data.

  • PDF

Quantitative Light-Induced Fluorescence의 이해와 치위생 과정에서의 활용방안 (Quantitative Light-Induced Fluorescence: A Potential Tool for Dental Hygiene Process)

  • 김희은
    • 치위생과학회지
    • /
    • 제13권2호
    • /
    • pp.115-124
    • /
    • 2013
  • Recently, there have been improvements in diagnostic methods for the assessment of early caries lesions. The reason is that dental professionals are seeking methods to reliably detect incipient dental caries and to remineralize them. This review examines the literature on principles, theoretical background, and history of the Quantitative Light-Induced Fluorescence (QLF) system (Inspektor Research Systems BV, The Netherlands). Furthermore, this paper discusses the potential application of QLF system to clinical practice for educational purpose, enabling dental hygiene students to perform oral health assessment using the QLF system. In addition, the clinical application of QLF system can motivate patients by providing additional visual information about caries and bacterial activity. The evidences on validity and reliability of the QLF system for detection of longitudinal changes in de/remineralization and caries were examined. The QLF system is capable of monitoring and quantifying mineral changes in early caries lesions. Therefore, it can be used to assess the impacts of caries preventive measures on the remineralization and reversal of the caries process. And the QLF system is a very promising equipment to assess educational effectiveness for dental hygiene students in their learning process. In conclusion, the QLF system is the most effective technology for more sensitive staging of caries and treatment without surgical intervention.