• Title/Summary/Keyword: Preventing equipment system

Search Result 103, Processing Time 0.022 seconds

A Study on the Characteristic of Electrical Construction Work for Prevention of Electric Shock Accident (감전재해 예방을 위한 전기공사업의 특성에 관한 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.29-34
    • /
    • 2014
  • The live line working is inherently dangerous as the workers have to work under the risk of electrical shock and most of works are carried out at height. The live line working need the some specific techniques and higher level safety measures such as a risk assessment to carry out works safely, but the electrical construction companies performed live-line working are usually small-sized companies. They have less capacity to have own safety management system. This study intended to conduct an in-depth analysis on the cause of electric shock accidents to provide basic data for policy proposing taking into considering the past eleven years for a long-term plan. And the aim of this study is to propose the policy about the equipment performance standards and/or worker's safety standards to revise the standards for preventing electric shock accidents, moreover, co-relation of the electrical work order form and on safety workings, especially electrical construction company/work.

Prosthetic restorations with cementless screw-retained implant systems: a case report (시멘트리스 나사 유지형 임플란트 시스템을 이용한 보철물 수복 증례)

  • Young-hae Jung;Im-Sun Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.4
    • /
    • pp.124-130
    • /
    • 2023
  • This study aims to describe the clinical experience of single and bridge crowns fabricated using a cementless screw-retained implant prosthesis system. In the case of single crown (#37), regular link (HDL) was used, and bridge crowns (#15~#24), (#26~#27), (#17~#14) (#24~#26) were fabricated by selecting regular link and short link considering the vertical height. One abutment was hex shaped to ensure that it could be mounted while preventing insertion and prosthesis rotation. The advantages of cementless implant prosthesis include shorter chair time and periodic care, strong retention with LINK abutment, safety from inflammation, bacterial infection, and complications due to peri-implant cement, and high patient satisfaction. Dentists should double-check the position of the implant fixture and dental technicians should continuously manage the fit of the link and prosthesis with digital equipment to reduce screw loosening and fractures.

Mobility and Thermal Comfort Assessment of Personal Protective Equipment for Female Healthcare Workers: Impact of Protective Levels and Body Mass Index (감염병 대응 개인보호복의 동작성 및 열적 쾌적성: 보호 수준 및 여성 착용자 체격의 영향)

  • Do-Hee Kim;Youngmin Jun;Ho-Joon Lee;Gyeongri Kang;Cho-Eun Lee;Joo-Young Lee
    • Fashion & Textile Research Journal
    • /
    • v.26 no.1
    • /
    • pp.123-136
    • /
    • 2024
  • This study aimed to assess the mobility and thermal comfort of personal protective equipment (PPE) among female healthcare workers, taking into account wearers' physique and PPE protection levels. A total of 16 participants (age: 26.3 ± 8.3 y, height: 161.5 ± 7.3 cm, body weight: 57.1 ± 11.0 kg, BMI: 21.9 ± 3.6), representing diverse body types, underwent four PPE conditions: L (Low_Plastic gown ensemble), M (Medium_Tyvek 400), H (High_Tyvek 800J with Powered Air Purifying Respirator [PAPR]), and E (Extremely high_Tychem 2000 with PAPR, Bib apron, and Chemical-resistant gloves). The mobility protocol consisted of 10 different tasks in addition to donning and doffing. The 10 tasks were repeated twice at an air temperature of 24.3 ± 0.1℃, 59±4%RH. Findings revealed a disproportionate relationship between PPE protection and wearer discomfort. Significant differences in clothing microclimate and total sweat rate were observed between the lowest (L) and highest (E) protection levels (p < 0.01), while distinctions among medium levels were inconclusive. Subjective evaluations favored conditions H and L over M and E (p < 0.05), indicating reduced heat, and humidity, increased comfort, and lower exertion. Instances of mobility discomfort, specially in the small body type group, underscored the need for a suitable PPE size system for Korean adult female medical workers. Furthermore, enhancements in gloves, shoe cover, and PAPR hood designs are essential for improving ease of movement and preventing hindrance.

Private and Public Securities' Mutual Cooperation Plans to Deal with Crimes Threatening the Livelihood of the People (민생침해범죄 예방을 위한 민간경비와 경찰의 상호협력방안)

  • Hong, Eun-sun;Kim, Tae-hwan
    • Journal of the Society of Disaster Information
    • /
    • v.4 no.1
    • /
    • pp.154-174
    • /
    • 2008
  • Korean public power isn't currently performing its duties of crime prevention or public security services as effectively as the people expect from it due to excessive work load, insufficient budget, and equipment or work force problems, although it should protect the people from increasing crimes. The mutual cooperation between the police and the private security firms can' t be enhanced unless both parties are involved. Above all, the private security companies should secure superior security personnel and provide them with systematic education and training to improve their qualities. The police should also make an effort. In order to foster the private security firms soundly, the police should improve the system if necessary, and establish, guide and monitor the department wholly responsible for the private security affair. Both parties also should deal with crimes systematically by exchanging information for crime prevention, having informal meetings and introducing a joint patrol system. In order to cope with crimes threatening the livelihood of the people in our society, the public and private securities' mutual cooperation plans should be formulated. For this purpose to be achieved, the private security firms and the police should understand each other and bilateral efforts should be made. If both parties understand each other and make an effort, the relationship between them will be improved greatly and developmental plans for preventing crimes can be made.

  • PDF

A Study on Measurement of Voltage Parameters using TEO&DESA in Auto-synchronizer (TEO&DESA를 활용한 Auto-synchronizer의 전압 파라미터 측정에 관한 연구)

  • Shin, Hoon-Chul;Han, Soo-Kyeong;Lyu, Joon-Soo;Cho, Soo-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.816-823
    • /
    • 2018
  • The Auto-synchronizer is essential equipment for synchronizing a generator to the power system. It is performing that measurement of the magnitude, frequency and phase of the voltage signal of the power system and generator. It is important to select the appropriate measurement algorithm for preventing various problem such as mechanical stress and Electrical problem. Teager Energy Operator(TEO) and Discrete separation algorithm(DESA) is measurable the instantaneous parameters of a sine wave using 5 samples and can be measured at a fast and with a simple operation. Therefore it has many advantages in measuring the parameters. In this paper, it confirmed measurement results using matlab simulations when there are synchronized in order of frequency, magnitude. Also it presented methods using digital filters and sample intervals to improve accuracy.

Development of Livestock Monitoring Device based on Biosensors for Preventing Livestock Diseases

  • Park, Myeong-Chul;Jung, Hyon-Chel;Ha, Ok-Kyoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.10
    • /
    • pp.91-98
    • /
    • 2016
  • Outbreaks of highly contagious livestock diseases can cause direct and indirect economic impacts such as lower productivity of cattle farms, fall in tourism in damaged areas and countries, and decline in exports. They also incur tremendous social costs associated with disease elimination and restoration work. Thus, it is essential to prevent livestock diseases through monitoring and prediction efforts. Currently, however, it is still difficult to provide accurate predictive information regarding occurrences of livestock diseases, because existing cattle health monitoring or forecasting systems are only limited to monitor environmental conditions of livestock barns and check activities of cattle by using a pedometer or thermal image. In this paper, we present a biosensor-based cattle health monitoring system capable of collecting bio-signals of farm animals in an effective way. For the presented monitoring system, we design an integrated monitoring device consisting of a sensing module to measure bio-signals of cattle such as the heartbeat, the breath rate and the momentum, as well as a Zigbee module designed to transmit the biometric data based on Wireless Sensor Network (WSN). We verify the validity of the monitoring system by the comparison of the correlations of designed device with a commercial ECG equipment through analyzing the R-peak of measured signals.

A study on the reliability enhancement of Ultrasonic water treatment system to boiler (보일러 초음파 수처리장치의 신뢰성향상에 관한 연구)

  • Kim, Dae-Ryong;Lee, Keun-Oh
    • Journal of Energy Engineering
    • /
    • v.22 no.3
    • /
    • pp.287-293
    • /
    • 2013
  • This study was carried out to diminish the formation of scale in boilers which is one of the defect elements when they are operating. The defect relating to scale can cause a fatal impact on the explosion of boilers due to the overheating of their tubes, or it can affect the flow of water inside boilers with its bad circulation and result in a disparity of water inside the equipment. Heat transfer in the scale is low comparing to the boiler material, so it can lead to energy losses and has also impact on the global warming. In 2005, the Korean government introduced a system which requires boiler users to install the equipment which can prevent or eliminate the formation of scale to improve the management of water quality in boilers. The study on the techniques for preventing or eliminating the formation of scale started in 1821 and since then subsequently there have been lots of similar studies. The first one was about the scale reduction using potato starch. Since an ultrasonic scale preventer developed by a scientist from a Russian acoustic institute was introduced in1993, a variety of equipment of this kind have been disseminated in Korea. There has been a need to demonstrate the condition for the best performances of such equipment. Boilers are mostly composed of the main body and 288 the tube with a circular curved surface. I carried out a demonstration study on a circular tube which affects the scale defect the most among the boiler components. As a result of it, I found out the fact that the ultrasonic wave needs to reach a certain level of sound pressure and frequency to affect the formation of scale.

A Study on the Establishment of Preventive Measures for Electric Fires Using the 4M Technique (4M 기법을 활용한 전기화재 예방대책 수립 연구)

  • Oh, Teakhum;Park, Chanseok
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.23-29
    • /
    • 2021
  • The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.

The Results of the Application of a Real-time Chemical Exposure Monitoring System in a Workplace (스마트 센서 세트를 활용한 화학물질 상시모니터링 시스템의 작업현장 적용 결과)

  • Wook Kim;Jangjin Ryoo;Jongdeok Jung;Gwihyun Park;Giyeong Kim;Jinju Kang;Kihyo Jung;Seunghon Ham
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.215-229
    • /
    • 2023
  • Objectives: To validate the effectiveness of a real-time chemical exposure monitoring system developed by KOSHA (Korea Occupational Safety and Health Agency), we applied the system to a workplace in the electronics industry for 153 days. Methods: The monitoring system consisted of a PID chemical sensor, a LTE communication equipment, and a web-based platform. To monitor chemical exposure, four sets of sensors were placed in two manufacturing tasks - inspection and jig cleaning - which used TCE as a degreasing agent. We reviewed previous reports of work environment measurements and conducted a new work environment measurement on one day during the period. The PID sensor systems detected the chemical exposure levels in the workplace every second and transmitted it to the platform. Daily average and maximum chemical exposure levels were also recorded. Results: We compared the results from the real-time monitoring system and the work environment measurement by traditional methods. Generally, the data from the real-time monitoring system showed a higher level because the sensors were closer to the chemical source. We found that 28% of jig cleaning task data exceeded the STEL. Peak exposure levels of sensor data were useful for understanding the characteristics of the task's chemical use. Limitations and implications were reviewed for the adoption of the system for preventing poisoning caused by chemical substances. Conclusions: We found that the real-time chemical exposure monitoring system was an efficient tool for preventing occupational diseases caused by chemical exposure, such as acute poisoning. Further research is needed to improve the reliability and applicability of the system. We also believe that forming a social consensus around the system is essential.

Development of a voyage performance monitoring system based on ENC for small and medium-sized vessels (전자해도 기반 중소형선박 항해 성능 모니터링 시스템 개발)

  • Lee, Kwangkook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1615-1622
    • /
    • 2016
  • This research aims to develop a voyage performance monitoring system based on international standards. The developed system is equipped with an electronic navigational chart(ENC) that provides onshore and offshore information, as well as supports standardized interfaces with navigational equipment, such as a gyro compass, a differential global positioning system(DGPS), and an automatic identification system(AIS), to monitor the navigation route in real time. In addition, the proposed system adopts a car navigation system to provide a graphical user interface, an intuitive menu-driven configuration, and an easy guide for safer sea navigation. The system, interfaced with the gyro compass and DGPS, was verified without any data loss, and passed a test conducted under extreme conditions by the Korea Laboratory Accreditation Scheme(KOLAS). Finally, the system contributes to preventing collision of vessels and minimizing casualties by maximizing the convenience of mariners which a conventional system does not provide.