• Title/Summary/Keyword: Preventing Deterioration

Search Result 97, Processing Time 0.028 seconds

New Diagnostic Technique and Device for Lightning Arresters by Analyzing the Wave Height Distribution of Leakage Currents (누설전류의 파고분포 분석에 의한 새로운 피뢰기 진단기술 및 장치)

  • 길경석;한주섭;송재영;조한구;한문섭
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.562-567
    • /
    • 2003
  • Lightning arresters are deteriorated by repetition of protective operation against overvoltages or impulse currents in environments of its use. If a deteriorated arrester is left in power lines, it can lead to an accident such as a line to ground fault even in a normal system. Therefore, it is necessary to eliminate the deteriorated arrester in advance by checking the soundness of arresters on a regular basis, and to ensure the reliability of power systems by preventing accidents. Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the wave height distributions of the total leakage currents are remarkably changed or a new wave height are produced with the progress of arrester deterioration. To propose a new technique for the diagnosis, we designed a leakage current detection unit and an analysis program which can measure leakage current magnitudes and analyze wave height distributions. From the experimental results, we confirmed that the proposed technique by analyzing the wave height distribution can simply diagnose the mode of defects such as a partial damage and an existence of punctures in arresters as well as deterioration of arresters.

A study on the fire resistance method using FR-ECC in long tunnel (고인성내화모르터(FR-ECC)를 사용한 장대터널 내화안전대책에 관한 연구)

  • Kim, Se-Jong;Kim, Dong-Jun;Kwon, Young-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.1
    • /
    • pp.9-18
    • /
    • 2011
  • The spalling phenomenon occurs in high-strength concrete when several factors such as sharp temperature increase, high water content, low water/cement ratio and local stress concentration in material combine in the concrete material. On the basis of the factors, the preventing methods from the spalling are known as reduction of temperature increase, preventing of concrete fragmentation and fast drying of internal moisture. In this study, the reduction of temperature increase was proposed as the most effective spalling-preventing method among the spalling-preventing methods. Engineered cementitious composite for fireproof and repair materials was developed in order to protect the new and existing RC structures form exterior deterioration factors such as fire, cloride ion, etc. This study was carried out to estimate the fire-resisting performance of high strength concrete slab or tunnel lining by repaired engineered cementitious composite (ECC) or fiber reinforcement cemetitious composite (FRCC) under fire temperature curve. and them we will descrike the result of HIDA tunnel in Japan.

Factors Influencing Cognitive Impairment in Elders with Dementia Living at Home (재가치매노인의 인지장애 영향 요인)

  • Ha, Eun-Ho;Park, Kyung-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.3
    • /
    • pp.317-327
    • /
    • 2011
  • Purpose: The purpose of this study was to contribute data toward prevention from advancing dementia and also prevention of deterioration in cognitive impairment by constructing an optimal prediction model and verifying factors influencing cognitive impairment in elders with dementia who reside at home. Methods: The participants in this study were 351 elders who were registered at dementia day care centers in 11 regions of Metropolitan Incheon. Collected data were analyzed using SPSS Statistics 17.0 and SAS 9.1. Bootstrap method using the Clementine program 12.0 was applied to build an optimum prediction model. Results: Gender and education (general characteristics), alcohol, urinary/fecal incontinence, exercise, weight, and ADL (state of health), and depression (psychological state) were found to have an affect on cognitive impairment in these elders. Conclusion: Study results indicate nine key factors that affect cognitive impairment of elders with dementia who reside at home and that could be useful in prevention and management nursing plans. These factors could also be used to expand the role of nurses who are working in community day care centers, and can be applied in the development and provision of various programs to aid retention and improve cognitive function as well as preventing deterioration of cognition.

Deterioration of Hiking Trails at Great Walksin New Zealand - Case Study on Tongariro Alpine Crossing, Routeburn, and Kepler Tracks - (뉴질랜드 그레이트 워크스의 탐방로 훼손 - 통가리로 알파인 크로싱, 루트번 및 케플러 트랙을 사례로 -)

  • Kim, Taeho
    • Journal of The Geomorphological Association of Korea
    • /
    • v.24 no.4
    • /
    • pp.103-115
    • /
    • 2017
  • This paper shows the types of deteriorated hiking trails and degrading factors at three Great Walks such as Tongariro Alpine Crossing, Routeburn Track and Kepler Track in New Zealand. The deteriorated trails could be classified into gullying, widening, narrowing, branching and sidewall erosion. Department of Conservation carefully manages overland flows on trails for preventing surface erosion, thus the Great Walks show only a minor problem of gully on trails which is usually active in a mountainous area. Widening and branching of trails caused by tread erosion are not also developed due to the restriction of visitors as well as the management of rainwash. However, despite the detailed maintenance and prevention of an overuse of trails, some trails traversing steep slopes in a alpine zone under a periglacial environment are severely degraded along their sidewalls. It suggests that a unvegetated sidewall of trails has to be strictly managed in an early stage of occurrence and a slope-traversing section should be selected with more consideration when establishing a route of hiking trails.

A Study on Economic Analysis of Development of On-line Diagnosis Technique for Preventing Electrical Accidents (전기설비사고예방을 위한 온라인진단기술 개발의 경제성 분석)

  • Kim, Han-Sang;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.313-318
    • /
    • 2014
  • In the last couple of decades industrialization and technological development has not only increase in the scale of electrical facilities and it has become more and more complicated and diversified. Furthermore, fires in the electrical transformers, like those that have knocked out power in the country in the past years, are likely to become more common as utility systems begin to show their age. The importance of preventing electrical accidents can never be overemphasized and for this reason, supply of on-line diagnosis system combining information and communication technology(ICT) for the customer's electrical facilities has been increasing recently. The major advantage of on-line diagnosis system is that the device's potential problems could be detected early before a serious deterioration or breakdown occurs. In this paper, We estimated the benefit from the investment in the right of present value of sales, success rate of commercialization regarding R&D investment for development and commercialization of on-line diagnosis technology targeting customer electrical facilities. As a result, the net value added of 29.7 billion won and the increased profit by roughly 7.52 precent are expected.

An Analysis of the Changes in Bone Mineral Density in Long-Stay Patients of a Geriatric Hospital in Relation to Physical Therapy

  • Lee, Sang-Min;Kim, Soon-Hee;Kim, Ji-Sung;Wang, Joong-San;Kim, Sung-Won;Kim, Nyeon-Jun;Lee, Sook-Hee;Min, Kyoung-Ok
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.2 no.2
    • /
    • pp.267-273
    • /
    • 2011
  • The purpose of this study is to examine the changes in bone mineral density in long-stay patients of a geriatric hospital in relation to physical therapy, thereby providing basic data for preventing the onset or deterioration of osteoporosis in inpatients of geriatric hospitals or relevant facilities. The subjects of this study were 133 elderly patients who had been in H geriatric hospital in Yongin-si for more than four years. Their bone mineral density T-scores at admission and those after four years were measured to compare and analyze the changes in bone mineral density in relation to physical therapy. According to the results, the decrease in T-score for the group without physical therapy was greater by .40 than that for the group with physical therapy, indicating a statistically significant difference between the two groups(p<.01). Accordingly, physical therapy proved to be effective in preventing bone mineral density loss and maintaining the current density.

Predicting the Number of People for Meals of an Institutional Foodservice by Applying Machine Learning Methods: S City Hall Case (기계학습방법을 활용한 대형 집단급식소의 식수 예측: S시청 구내직원식당의 실데이터를 기반으로)

  • Jeon, Jongshik;Park, Eunju;Kwon, Ohbyung
    • Journal of the Korean Dietetic Association
    • /
    • v.25 no.1
    • /
    • pp.44-58
    • /
    • 2019
  • Predicting the number of meals in a foodservice organization is an important decision-making process that is essential for successful food production, such as reducing the amount of residue, preventing menu quality deterioration, and preventing rising costs. Compared to other demand forecasts, the menu of dietary personnel includes diverse menus, and various dietary supplements include a range of side dishes. In addition to the menus, diverse subjects for prediction are very difficult problems. Therefore, the purpose of this study was to establish a method for predicting the number of meals including predictive modeling and considering various factors in addition to menus which are actually used in the field. For this purpose, 63 variables in eight categories such as the daily available number of people for the meals, the number of people in the time series, daily menu details, weekdays or seasons, days before or after holidays, weather and temperature, holidays or year-end, and events were identified as decision variables. An ensemble model using six prediction models was then constructed to predict the number of meals. As a result, the prediction error rate was reduced from 10%~11% to approximately 6~7%, which was expected to reduce the residual amount by approximately 40%.

Study on Mutual Relation between the Level of Deterioration Influenced by the Changes of Chemical and Physical Properties and the Change of Dielectric Constant for Engine Oil - Gasoline Engine Oil (엔진오일의 화학적 및 물리적 변화에 의한 퇴화정도와 유전상수 변화에 관한 상호관계 연구 - 가솔린엔진오일)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.22 no.5
    • /
    • pp.260-268
    • /
    • 2006
  • The dielectric constants of used gasoline engine oils were obtained at a few temperatures and a frequency. Through analyzing the characteristics of dielectric constant, the related correlation between the changes in dielectric constants of oil and the degree of oil deterioration is going to be found. The dielectric constant was calculated using cross capacitances measured by a sensor tube. As results of the measurement of the fresh engine oil's dielectric constant, it was found that the value of dielectric constant was set down below $60^{\circ}C$ regardless changing frequency. Further, above 6 kHz, the dielectric constant was set down even if temperature was above $100^{\circ}C$ Therefore, for the measurement of used oils, it was selected the frequency of 6 kHz,,and the temperature of $80^{\circ}C$ preventing a certain ionic-conduction effects on the measured dielectric constant and the evaporation of a certain fluid mixed with engine oil. Specially, the effects of the mixing fluid like coolant, water and fuel on the fresh engine oil's dielectric constant were studied. It was found that the oil mixed with coolant showed the highest value, next water, and the lowest fuel. As results of the measurement of the used engine oil's dielectric constant, it was found that the possible changed rate of the used engine oil's dielectric constant based on the warning limit for engine oil in service was below 4% for gasoline engine oil.

Study on Mutual Relation between the Level of Deterioration Influenced by the Changes of Chemical and Physical Properties and the Change of Dielectric Constant for Engine Oil - Diesel Engine Oil (엔진오일의 화학적 및 물리적 변화에 의한 퇴화정도와 유전상수 변화에 관한 상호관계 연구 - 디젤엔진오일)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.22 no.5
    • /
    • pp.290-300
    • /
    • 2006
  • The dielectric constants of used diesel engine oils were obtained at a few temperatures and a frequency. Through analyzing the characteristics of dielectric constant, the related correlation between the changes in dielectric constants of oil and the degree of oil deterioration is going to be found. The dielectric constant was calculated using cross capacitances measured by a sensor tube. As results of the measurement of the fresh engine oil's dielectric constant, it was found that the value of dielectric constant was set down below $60^{\circ}C$ regardless changing frequency. Further, above 6 kHz, the dielectric constant was set down even if temperature was above $100^{\circ}C$. Therefore, for the measurement of used oils, it was selected the frequency of 6 kHz, and the temperature of $80^{\circ}C$ preventing a certain ionic-conduction effects on the measured dielectric constant and the evaporation of a certain fluid mixed with engine oil. Specially, the effects of the mixing fluid like coolant, water and fuel on the fresh engine oil's dielectric constant were studied. It was found that the oil mixed with coolant showed the highest value, next water, and the lowest fuel. As results of the measurement of the used engine oil's dielectric constant, it was found that the possible changed rate of the used engine oil's dielectric constant based on the warning limit for engine oil in service was below 10% for diesel engine oil.

Assessment of interhospital transport care for pediatric patients

  • Chaichotjinda, Krittiya;Chantra, Marut;Pandee, Uthen
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.5
    • /
    • pp.184-188
    • /
    • 2020
  • Background: Many critically ill patients require transfer to a higher-level hospital for complex medical care. Despite the publication of the American Academy of Pediatrics guidelines for pediatric interhospital transportation services and the establishment of many pediatric transport programs, adverse events during pediatric transport still occur. Purpose: To determine the incidence of adverse events occurring during pediatric transport and explore their complications and risk factors. Methods: This prospective observational study explored the adverse events that occurred during the interhospital transport of all pediatric patients referred to the pediatric intensive care unit of Ramathibodi Hospital between March 2016 and June 2017. Results: There were 122 pediatric transports to the unit. Adverse events occurred in 25 cases (22%). Physiologic deterioration occurred in 15 patients (60%). Most issues (11 events) involved circulatory problems causing patient hypotension and poor tissue perfusion requiring fluid resuscitation or inotropic administration on arrival at the unit. Respiratory complications were the second most common cause (4 events). Equipment-related adverse events occurred in 5 patients (20%). The common causes were accidental extubation and endotracheal tube displacement. Five patients had both physiologic deterioration and equipment-related adverse events. Regarding transport personnel, the group without complications more often had a physician escort than the group with complications (92% vs. 76%; relative risk, 2.4; P=0.028). Conclusion: The incidence of adverse events occurring during the transport of critically ill pediatric patients was 22%. Most events involved physiological deterioration. Escort personnel maybe the key to preventing and appropriately monitoring complications occurring during transport.