• 제목/요약/키워드: Pressure-swirl spray

검색결과 155건 처리시간 0.025초

난류선회 등온 및 분무연소 유동에 대한 수치해석 (Numerical Study of Turbulent Swirling Isothermal and Spray-Combusting Flows)

  • 김성구;안국영;김용모;이창식
    • 한국자동차공학회논문집
    • /
    • 제4권5호
    • /
    • pp.130-141
    • /
    • 1996
  • Numerical study of a confined, swirling, isothermal and spray-combusting flows has been presented. The pressure-velocity coupling in the Eulerian gas-phase equation is handled by the improved PISO algorithm. The droplet dispersion by turbulence is introduced by a Stochastic Separated Flow(SSF) model. The k-$\varepsilon$ turbulence model and the eddy dissipation model are employed to account for turbulence-combustion interaction. The detailed comparison with experimental data has been made for the isothermal jet swirling flows and the nearly monodisperse spray-combusting flow in the swirl combustor.

  • PDF

SI 機關용 電子制御 燃料噴射노즐의 過渡的 現象 (The Transient Phenomena of Fuel Injection Nozzle for Electronic Control SI Engines)

  • 김신구;김덕줄;이충원
    • 대한기계학회논문집
    • /
    • 제12권2호
    • /
    • pp.308-318
    • /
    • 1988
  • 본 연구에서는 가압된 액체를 가류실에 접선방향으로 도입하게 함으로써 선회운동에 의하여 미립화를 시키도록 스크류형의 선회분사 노즐을 설계제작하였다.

Evaluation of the Induction and Ionized Field Charging Methods for Electrostatic Nozzles of Orchard Sprayer

  • Laryea, G.N.;No, S.Y.;Lee, D.H.
    • Agricultural and Biosystems Engineering
    • /
    • 제3권1호
    • /
    • pp.29-34
    • /
    • 2002
  • Two charging methods of electrostatic nozzle, i.e. induction and ionized field corona charging, were designed and evaluated for orchard sprayer application. An artificial (metallic) target was constructed and used in this experiment. The charge-to-mass ratio for the induction electrode was measured by using the Faraday cage. Two conventional pressure-swirl nozzles have been employed with different orifice diameters under the same experimental operating conditions. A commercial pressure-swirl nozzle with orifice diameter of 1.0 was used for the conventional spray. The diameter of the electrostatic was 0.59 mm. The experiment was carried out for individual nozzle sprays at $0^{\circ}$, $20^{\circ}$ and $50^{\circ}$ oriented angles and three nozzles, sprayed simultaneously at a distance of 1.0 and 2.0 m from the nozzle tip to the target. The nozzles were mounted on a carriage with constant speed of 1.26 km/h with a blower attached. The weighing method was employed to evaluate for the spray deposition, ground loss and estimated drift. The results show more promising for the induction charging method, especially at $20^{\circ}$oriented angle at a distance of 1.0 m from the target for a single nozzle and when all three nozzles were operated simultaneously for spray deposition. The results of the induction charging method show promising with the developed electrostatic technique.

  • PDF

횡방향 유속 변화에 따른 고압 가솔린 팬형 인젝터의 분무특성 (Spray Characteristics of High Pressure Fan Spray Injector with Various Crossflow Speed)

  • 최재문;문석수;배충식
    • 한국분무공학회지
    • /
    • 제10권3호
    • /
    • pp.38-44
    • /
    • 2005
  • The direct injection into the cylinders has been regarded as a way of the reduction in fuel consumption and pollutant emissions. The spray produced from the injector of DIS(Direct Injection Spark Ignition) engine is of paramount importance in DISI engines. Fan-spray injector as well as swirl-spray injector was developed and utilized to the DISI engines. The interaction between air flow and fuel spray was investigated in a steady flow system embodied in a wind tunnel to simulate the variety of flow inside the cylinder of the DISI engineer. The direct Mie scattered images presented the macroscopic view of the liquid spray fields interacted with crossflow. Particle sizes of fuel droplets were measured with phase Doppler anemometer(PDA) system. A faster cross-flow field made SMD larger and $D_{10}$ smaller. The experiments show the interaction of air flow field and the fuel spray field of fan-spray. The results can be utilized to construct the data-base for the spray and fuel-air mixing mechanism as a function of the flow characteristics.

  • PDF

Investigation of Turbulent Spray Disintegration Characteristics Depending on the Nozzle Configuration

  • Lee, Sam-Goo;Song, Kyu-Keun;Park, Byung-Joon
    • Journal of Mechanical Science and Technology
    • /
    • 제16권4호
    • /
    • pp.572-579
    • /
    • 2002
  • The experimental measurements were carried out to examine turbulent disintegration characteristics ejecting from a counter-flowing internal mixing pneumatic nozzle under variable conditions of swirl angles and air pressures. The air injection pressure was varied from 60 kPa to 180 kPa and four counter-flowing internal mixing nozzles with axi-symmetric tangential-drilled holes at swirl angle of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$to the central axis have been specially designed. The experimental results were quantitatively analyzed, focusing mainly on the comparison of turbulent atomization characteristics issuing from an internal mixing swirl nozzle. To illustrate the swirl phenomena, the distributions of mean velocities, turbulence intensities, volume flux, and SMD (Sauter Mean Diameter, or D$\sub$32/) were comparatively analyzed.

분열모델 상수가 분무 및 연소특성에 미치는 영향 (Effects of Spray Breakup Model Variables on Spray and Combustion Characteristics)

  • 이승필;박준규;박성욱
    • 한국분무공학회지
    • /
    • 제22권1호
    • /
    • pp.29-35
    • /
    • 2017
  • This paper describes the effects of spray breakup model constants on spray and combustion characteristics in single cylinder compression engine. KIVA-3V code coupled with a CHEMKIN chemistry solver was used for numerical analysis. In this study, spray simulations and combustion simulations are studied simultaneously. Spray simulation was conducted in constant volume to reduce the effects of air-flow as swirl or tumble. The model validation was conducted and there are little difference between experiments and simulation, this differences were reasonable. In spray simulation, the effects of model constants on spray tip penetration, spray patter and SMD were studied. Furthermore, the analysis of effects of breakup variables on combustion and emissions characteristics was conducted. The results show the KH-RT breakup model constants affects spray and combustion characteristics strongly. Increasing KH model variable (B1) and RT model constants ($C_{\tau}$, $C_{RT}$) induced slower breakup time.

가솔린 직접분사식 고압 슬릿 노즐 분사기의 팬형 분무 특성 고찰 (Pan-shaped Spray Characteristics of GDI High Pressure Slit Nozzle Injector)

  • 송범근;김원태;강신재
    • 한국자동차공학회논문집
    • /
    • 제13권6호
    • /
    • pp.70-76
    • /
    • 2005
  • A new stratified charge combustion system has been introduced and developed for GDI engines. Before this new GDI system, the stratified mixture was formed by a high pressure swirl injector. But, the special feature of new system is employed of a thin fan-shaped fuel spray formed by a slit type nozzle. Also, this system has been adopted a shell-shaped piston cavity. We made high pressure gasoline injection system and investigated the fan-shaped spray characteristics such as spray tip penetration, spray angle, SMD and velocities of droplets using PDPA(Phase Doppler Particle Analyzer) system and spray visualization system to obtain the concept of the new design and the fundamental data for the next generation GDI system. The experiment was performed at the injection pressures of 5 and 9MPa under the atmospheric condition.

기체주입을 이용한 와류형 분사기들에서의 가변추력 연구 (A Study on the Thrust Throttling Using Gas Injection in Swirl Injectors)

  • 이원구;윤영빈;안규복
    • 한국분무공학회지
    • /
    • 제23권4호
    • /
    • pp.159-168
    • /
    • 2018
  • Thrust throttling in a liquid rocket engine can be implemented via several ways such as high pressure drop injector, dual manifold, multiple chamber, pintle injector, and gas injection. Thrust throttling using gas injection controls thrust by usually injecting inert gas into propellant through an aerator to reduce the propellant's bulk density. In this study, the outside-in aerator was used in the propellant line to create two phase flow. Closed-type, open-type, and screw-type bi-swirl coaxial injectors were utilized for investigating throttling characteristics such as pressure drop, mixture density, and discharge coefficient according to gas-liquid mass ratio.

이중분무의 중첩영역과 단일분무에서 액적의 거동 특성 (Characteristics of the Droplet Behavior in the Overlap Region of Twin Spray and in Single Spray)

  • 정지원;차건종;김덕줄
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1300-1308
    • /
    • 2000
  • The objectives of this study was to investigate the spray characteristics of single spray and twin spray in the overlap region such as mean axial velocity, mean radial velocity, mean droplet size and probability density function of droplet size. A phase doppler anemometer was used as the measurement system for droplet size and velocity. In case of single spray, injection pressure was varied from 0.2MPa to 0.7MPa. Mean axial velocity, mean radial velocity and droplet size were decreased as the distance below nozzle tip was increased. In case of twin spray, the spray characteristics were measured by varying the distance between two nozzles from 127mm to 155mm. In the overlap region, the boundary of the overlap region was determined by obtaining the distribution of mean axial and radial velocity. Droplet size was increased as the distance from nozzle tip was increased. It was found that the distribution of droplet size for twin spray in the overlap region was different to single spray.

충돌형 노즐의 분무형상 연구 (External Spray Characteristics of Deflector Nozzle)

  • 김경훈;최영하;윤석주
    • 한국분무공학회지
    • /
    • 제7권1호
    • /
    • pp.29-35
    • /
    • 2002
  • This study describes the external spray characteristics of deflector nozzle such as the breakup procedures of liquid sheet, spray angle, breakup length and bubble behaviors of spray at deflector nozzle. In order to visualize the spray behaviors shadow graphy technique were used. According to the increase injection pressure, deveopment of the spray passes through the dribbling, distoted jet, closed bubble due to the contraction by form a conical sheet like as the simplex swirl atomizer. As trying the analysis of the ratio of bubble length and width it was found that the ratios is comparable. Spray cone angle was nearly $90^{\circ}$.

  • PDF