• 제목/요약/키워드: Pressure-drop Coefficient

검색결과 382건 처리시간 0.027초

2열 휜 튜브 열교환기의 공기측 압력강하 및 열전달 특성을 고찰하기 위한 확대 모형실험 (A large scale model test to investigate the pressure drop and heat transer characteristics in the air side of two-row heat exchanger)

  • 강희찬;김무환
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.113-124
    • /
    • 1997
  • This work is performed to investigate the pressure drop and heat transfer characteristics in the air side of finned-tube heat exchanger for air conditioner. Experimental apparatus and method are described to simulate the heat exchanger performance by using the three times enlarged model. The pressure drop and heat transfer coefficient were measured and compared for the heat exchangers with a plane fin and a commercial strip fin. The measured data for the strip fin agree well with those of prototype within a few percentages. For the plane fin, the measured data had similar trend to Gray & Webb's correlation at high air velocity, however a new correlation is needed to give more accurate prediction at low air velocity. It is found that most heat was transferred around the front row of the two-row heat exchanger, and the ratio of thermal load at the front tube row was increased for decreasing air velocity.

유턴 흐름을 갖는 차량공조용 플레이트형 증발기의 전열특성에 관한 연구 (A study on the characteristics of heat transfer and pressure drop in plate type evaporator with U-turn for automotive air conditioner)

  • 강정길;김종수
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.472-483
    • /
    • 1999
  • The evaporation heat transfer and pressure drop characteristics for HFC-l34a in flat plate type heat exchangers with enhanced beads were experimentally investigated. Three plate type evaporators with different geometric condition of U-turn area were tested. Mass fluxes were tested over the range of 83kg/$m^2$s to 166kg/$m^2$s, and heat fluxes were varied from 4㎾/$m^2$ to 12㎾/$m^2$. Evaporation temperature was 5$^{\circ}C$ with inlet qualities of 0.1 to 1.0. There was no notable difference in the heat transfer coefficient by geometric variation of U-turn area, but the third plate with cross-ribbed channel at U-turn area was better than others in the evaluation using volume goodness factor comparison. Also, the mixtures of HFC-l34a and PAG oil was tested to determine oil effects on heat transfer and pressure drop. As oil concentration was increased, heat transfer coefficient was increased by 22~48% up to the 3wt.%, but decreased by 14~22% at the 4wt.%. The pressure drop was increased by the maximum of 100% as oil concentration was increased.

  • PDF

원관내의 이상선회유동 특성에 관한 연구 (The study on the Two-Phase Swirl Flow Characteristics in Cylindrical Pipe)

  • 차경옥;김재근
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.187-197
    • /
    • 1996
  • Many investigations have been made to determine the pressure drop and heat transfer characteristics for single phase flow in tape generated swirl flow. But few studies have been carried out to investigate the heat transfer in two component, two phase swirl flow with non-boiling. An experimental study has been conducted to determine the effects of tape twist ratios on two phase convective heat transfer coefficients, pressure drop, and void fraction distribution in a non-boiling, air-water, two phase flow. The flow conditions were both swirl and non swirl flows. The internal diameter of the test section is 42.5mm. The tape twist ratios of pitch to diameter ratio varied from 4.0 to 10.6. The heating conditions were isothermal and nonisothermal. The flow patterns identified with experiments were bubbly, bubbly-slug, slug, and slug-annular flow in up-flow. This study has concluded that no significant difference in void fraction distribution were observed both isothermal and nonisothermal conditions, the pressure drop for two phase flow with twisted tape swirler increase as the tape twist ratio decrease, and that values of two phase heat transfer coefficient increase when the tape twist ratio decreases.

  • PDF

흡수식 냉온수기 증발기용 전열관의 전열성능에 관한 연구 (A-Study on The Heat Transfer Performance of Evaporator Heat Transfer Tube for Absorption Chiller)

  • 권오경;차동안;윤재호;김효상
    • 설비공학논문집
    • /
    • 제21권4호
    • /
    • pp.215-221
    • /
    • 2009
  • The objectives of this paper are to measure the heat transfer and pressure drop of the heat transfer tube for an evaporator of absorption system applications. Five types of heat transfer tubes with different shape and heat transfer area are tested in the present experiment. Heat transfer and pressure drop performance of heat transfer tubes are measured in various operating conditions, and compared each other. The results show that the heat transfer coefficient of thermoexcel notch tube increases about 79.6% and 45.3% at the film Reynolds number 69.7 compared with that of bare tube and low fin tube, respectively. The thermoexcel notch tube is show the best performance considering pressure drop and heat transfer coefficient.

수평관내 이산화탄소의 증발 압력강하 (Evaporation pressure drop of $CO_2$ in a horizontal tube)

  • 이동건;손창효;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.552-559
    • /
    • 2005
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor qualify, heat flux and saturation temperature. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations. the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

임계점 부근에서 이산화탄소의 증발열전달 및 압력강하 특성 연구와 상관식 개발 (Characteristics of Evaporative Heat Transfer and Pressure Drop of Carbon Dioxide and Correlation Development near the Critical Point)

  • 윤석호;조은석;김민수
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.530-537
    • /
    • 2004
  • In recent years, carbon dioxide among natural refrigerants has gained consider-able attention as an alternative refrigerant due to its excellent thermophysical properties. However, few investigations have been performed to develop useful correlations of heat trans-fer coefficients and pressure drop during evaporation of carbon dioxide. This study is aiming at providing the characteristics of heat transfer and pressure drop during the evaporation process of carbon dioxide. Heat is provided by a direct heating method to the test section, which was made of a seamless stainless steel tube with an inner diameter of 7.53 mm, and a length of 5.0 m. Experiments were conducted at saturation temperatures of -4 to 2$0^{\circ}C$, heat fluxes of 12 to 20 ㎾/$m^2$ and mass fluxes of 200 to 530 kg/$m^2$s. A comparison of different heat transfer correlations applicable to evaporation of carbon dioxide has been made. Based on the experiments for evaporation heat transfer and pressure drop, new correlations were developed. The newly developed empirical correlations for the heat transfer and pressure drop show average absolute deviations of 15.3% and 16.2%, respectively.

재료품 품질의 변동이 필터 공기희석율 변동에 미치는 영향 (The Effects of Cigarette Component Variability on Filter Ventilation Variability by Monte Carlo Analysis.)

  • 김정열;김종열;신창호;정한주
    • 한국연초학회지
    • /
    • 제22권2호
    • /
    • pp.151-156
    • /
    • 2000
  • The variability of a ventilated filter cigarette depends on the details of its construction and on the variabilities of its components. Variations in filter ventilation arise from many sources, including variations in tobacco rod pressure drop, filter tip pressure drop, tipping paper permeability, and plugwrap permeability. To reduce the filter ventilation variability, the variability of filter ventilation levels in ventilated cigarettes is studied by Monte Carlo Analysis. For each trials a value is selected for tobacco rod pressure drop, filter tip pressure drop, tipping paper permeability, and plugwrap permeability. These values are selected randomly from a normal distribution based on the target and coefficient of variation for each input variable. The results of this analysis for filter ventilation variation suggest that the variations of filter ventilation are dependent on the details of cigarette designs studied and reducing the variability of any cigarette component will reduce filter ventilation variability. For typical cigarettes, variation in the permeability of tipping paper is usually the most significant contributor to filter ventilation variability. Results of a Monte Carlo Analysis could provide both general insights and specific practical guidance about the design of ventilated filter cigarettes.

  • PDF

간접 냉동 시스템용 2차 냉매의 열전달과 압력강하 특성 (Heat Transfer and Pressure Drop Characteristics of Secondary Refrigerants Applying to Indirect Refrigeration System)

  • 오후규;손창효;조환;이문빈;전민주
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.45-50
    • /
    • 2013
  • This paper presents the comparison of heat transfer and pressure drop of various secondary refrigerants (single-phase and two-phase) in the indirect refrigeration system. The main results were summarized as follows: In case of heat transfer, it is useful to use secondary refrigerants in low evaporating temperature region and the heat transfer coefficient of single-phase is larger than two-phase secondary refrigerants. In case of pressure drop, it is useful to use secondary refrigerants in high evaporating temperature region and the pressure drop of two-phase is smaller than single-phase secondary refrigerant. Also, $CO_2$ is the best useful because pressure drop of $CO_2$ among the secondary refrigerants is the smallest.

벨 마우스 흡입구 보호망에 의한 전압력 손실영향 연구 (Study on the Effect of Total Pressure Loss by Bell Mouth Inlet Screen)

  • 이창욱;최성만
    • 한국추진공학회지
    • /
    • 제25권6호
    • /
    • pp.29-35
    • /
    • 2021
  • 벨 마우스 흡입구는 압력 손실이 거의 발생하지 않으며 정확한 유량 계측이 가능하다는 장점이 있어 다양한 산업에서 적용되고 있다. 본 연구에서는 벨 마우스 흡입구의 벨 형태를 Long radius 형상으로 설계하였고 야외 환경에서 엔진 운용조건에 대해 흡입되는 공기의 압력강하가 발생되는 동시에 외부 물질에 의한 엔진 손상이 발생되지 않는 적합한 보호망의 격자 사이즈를 선정하였다. 보호망 설치로 인한 전압력 손실에 대해 전산 해석 및 실험 결과 획득한 두 가지 데이터 로부터 수정된 압력 강하 계수 방정식을 제시할 수 있었다.

마이크로핀관내 냉동기유가 초임계 이산화탄소의 열전달과 압력강하에 미치는 영향 (Effect of the lubrication oil on heat transfer and pressure drop characteristics of supercritical carbon dioxide in a microfin tube)

  • 구학근
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1440-1446
    • /
    • 2012
  • 본 논문은 수평 마이크로핀관내 초임계 $CO_2$와 PAG 혼합물의 열전달과 압력강하 특성에 대해서 실험적으로 연구한 것이다. $CO_2$와 PAG 혼합물의 열전달계수는 압력이 10 MPa이고, 질량유속은 520 kg/$m^2s$이며, PAG 오일 농도는 0.06~2.26%에서 측정하였다. PAG 오일농도가 0.3%인 경우, $CO_2$와 PAG 혼합물의 열전달계수와 압력강하는 순수 $CO_2$ 냉매의 열전달계수와 동일한 경향을 나타내었다. 그리고 PAG 질량농도가 2.26%인 경우, 초임계 온도근처에서 측정한 열전달계수는 순수 $CO_2$의 열전달계수 보다 약 50%정도 낮게 나타났다. 마찰압력강하는 $60^{\circ}C$$CO_2$ 평균온도에서 순수 $CO_2$의 압력강하보다 약 1.6배 더 높게 나타났다.