• Title/Summary/Keyword: Pressure transducer

Search Result 329, Processing Time 0.03 seconds

Design of a Push-Pull Type High Power Ultrasonic Transducer by using the PEM (유한요소해석을 이용한 푸쉬-풀형 고출력 초음파 트랜스듀서 설계)

  • 윤양기;강국진;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.107-114
    • /
    • 2000
  • This work is aimed to develop a new type of the Push-Pull ultrasonic transducer that can provide higher sound pressure level and simpler internal structure than conventional types. The driving part of the newly designed transducer is positioned in the middle of the cylinder, and its optimum geometry is determined by using the FEM package, ANSYS. Through FEM model analysis, the effects of all of its geometrical variables such as transducer length, transducer radius, and the edge shape of the end cap have been examined, and the results have led to the optimum geometry. The newly designed transducer has been found to give better performance than that of traditional ones.

  • PDF

Evaluation of Feed Values of Korean Straws Using Pressure Transducer (Auto-Pressure Transducer를 이용한 국내산 고간류의 사료가치평가)

  • Lee, Sang S.;Ha, J. K.;Chang, M. B.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.241-250
    • /
    • 2003
  • Accurate and rapid evaluation of the nutritional quality of Korean straws is important because of the recent increase in the use of these feedstuffs in Korean. The aim of the study was to establish with relationships between ruminal fermentation of Korean straws and in vitro gas production using a pressure transducer. The pressure transducer system includes pressure censors, AD board, LED monitor, and the computer with real-time graphics. Both gas production and DM digestibility data were fitted into the exponential equation P = a + b (1-e-$1-e^{-ct}$). The initial rate of gas production was highest for rice straw, followed by barley straw and wheat straw. The gas production rate of constant (c) in gas production for rice straw, wheat straw, and barley straw were 3.8, 2.5, and 2.5 $%h^{-1}$, respectively. Total VFA concentration (mM) produced after 72h incubation was similar among three Korean straws, even though was variable during the early (12h) fermentation. Volume of gas production was related (P> 0.05: r = 0.76 to 0.83) to DM disappearance and also strongly related (p< 0.05: r = 0.91 to 0.98) to VFA concentration at all incubation times. Linear correlation showed between gas production and DM disappearance and VFA by in vitro will be matched in in vivo digestibility.

Multi-Point Radial Artery Pulse Wave Transducer using Pneumatic System (공압 방식에 의한 다지점 요골 맥파 검출 장치)

  • 이종진;정민석;황성하;이종현;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.243-248
    • /
    • 2001
  • A radial artery pulse wave is well known as a good mans to diagnose human body condition in th field of Chinese medical science. Information about constitution as well as organs can be obtained by detecting the artery pulse wave. Recently, the information about the human body constitution may be utilized in accelerating the recovery process of the patient on the basis of comprehensive diagnosis. A radial artery pulse wave is considered as one of promising means in examining the human body constitution. Since the examination has been conducted by the feeling of finger, the diagnosis may occasionally have uncertainty or fatal error. In this paper, a new measuring system is suggested and developed to examine the pattern of a pulse wave correctly. The system is composed of four pressure vessels, pressure sensors and air supplying pumps. One of them is utilized for appropriately pressing the radial artery, three of them for detecting pressure change in several mmHg level. The detected data is shown and discussed.

  • PDF

Application of Ultrasonic Wave to the Squeezing Process From the Seeds (식물 씨앗의 착유과정에 있어서 초음파의 적용)

  • Kim, Jung-Soon;Lee, Hui-Uk;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.2
    • /
    • pp.91-96
    • /
    • 2010
  • To improve the limit of efficiency of squeezing oil in a conventional method, which seeds are compressed simply, the adoptability of the additional energy by the ultrasonic wave was investigated experimentally. As the results, using the ultrasonic vibration from the Langevin-type transducer, the efficiency was increased up to 25 %, whereas the conventional method has 15% efficiency. To investigate the additional pressure by the ultrasonic wave, the acoustic impedance of the sample and the vibration velocity of the transducer were measured. Although the amplitude of the ultrasonic is about 2.8 % of the compression pressure, the efficiency is increased a lot as mentioned above because the pressure is changed according to ultrasonic period.

Finite element analysis for acoustic and temperature characteristics of a piezoelectric HIFU transducer at 10 MHz (10 MHz용 압전 HIFU 트랜스듀서의 음향 및 온도 특성에 대한 유한요소해석)

  • Jong-Ho Kim;Il-Gok Hong;Ho-Yong Shin;Hyo-Jun Ahn;Jong-In Im
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.116-123
    • /
    • 2023
  • A high intensity focuses ultrasound (HIFU) is one of the emerging technologies in the biomedical field. The piezoelectric HIFU transducer is a device that utilizes the thermal energy generated by high ultrasound energy. Recently an operating frequency of the HIFU transducer is to expand above a 7 MHz. In this study, the acoustic pressures and temperature distributions in the tissue that generated by the HIFU transducer at 10 MHz were calculated with the finite element method. In addition, the pressure focusing characteristics of the device were analyzed. The geometrical variables are the piezomaterial thickness, lens shape, water height, and film thickness. The results shown that the acoustic pressure increased and saturated gradually when the height/radius (HL/RL) ratio of the lens increased. Moreover, the focal area was gradually decreases with HL/RL ratio of the lens. In case of the optimized HIFU transducer, the maximum pressure and temperature were analyzed about 19 MPa and 65℃ respectively. And the -3 dB focused distances in the axial and lateral direction are around 2.3 mm and 0.23 mm respectively.

Thermal Dispersion Method for a Medical Ultrasonic Phased Array Transducer (의료용 초음파 위상배열 트랜스듀서의 열 분산 방안)

  • Lee, Wonseok;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.3
    • /
    • pp.210-218
    • /
    • 2015
  • When the driving voltage of an ultrasound transducer is increased to improve the quality of ultrasound images, heat is generated inside the transducer that can cause patient's skin burn and degradation of transducer performance. Hence, in this paper, a method to disperse the heat of the transducer has been studied. The phased array transducer having 3 MHz center frequency and 32 channels was selected for analyses of the thermal dispersion. First, mechanism of the heat generation was investigated in relation to the transducer operation through theoretical analysis, and material damping and sound pressure amplitude were confirmed to be influential on the heat generation. Further, we investigated the effects of the properties of the materials constituting the transducer on the thermal dispersion through finite element analysis. Based on the analysis results, we determined the thermal properties of the constituent materials that could facilitate the thermal dispersion inside the transducer. The determined thermal properties were applied to the finite element model, and the results showed that the maximum temperature at an acoustic lens contacting with a patient was decreased to 51 % of its initial value.

Flexible Visuo-haptic Display (필름형 유연 시-촉각 융합 디스플레이)

  • Yun, Sungryul;Park, Suntak;Park, Bongje;Park, Seung Koo;Nam, Saekwang;Kyung, Ki-Uk;Prahlad, Harsha;von Guggenberg, Philip
    • The Journal of Korea Robotics Society
    • /
    • v.8 no.3
    • /
    • pp.156-163
    • /
    • 2013
  • This paper describes a flexible visuo-haptic display module. We have developed a flexible electro-active polymer (EAP) actuator and a thin flexible visual display with $3{\times}3$ array configuration via polymer technology. The flexible actuator consists of nine EAP cells vertically moving in response to change in their thickness. The flexible display uses polymer based optical waveguide allowing light to scatter only at specific area. The display film is transparent and identically designed to the array pattern to fit for the arrangement of actuator cells. A pressure sensor is installed under the integrated module. The performance of the actuator is proved to be sufficient for satisfying perceivable range of human touch sense. The integrated system can provide interactive haptic feedback such as key pressing, contact vibration sensations, and etc. in accordance with user input.

Design of a FFR-typed High Power Deep-water Sonar Transducer using a Coupled FE-BEM (결합형 유한요소-경계요소 기법에 의한 FFR 형태의 고출력 심해저용 쏘나 변환기 설계)

  • Jarng Soon Suck;Lee Je Hyeong;Ahn Heung Gu;Choi Heun Ho
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.224-227
    • /
    • 1999
  • A high power deep-water sonar transducer of FFR (Free Flooded Ring) type has been designed using a coupled FE-BEM. The present sonar transducer is composed of rectangular piezoelectric ceramics and pie-shaped steels (or the advantage of simple fabrication. The dynamics of the sonar transducer is modelled in three dimensions and is analyzed with external electrical excitation conditions. Different results are available such as steady-state frequency response for TX and RX displacement modes, directivity patterns, back-scattering patterns, bandwidths, transmitting voltage responses and receiving sensitivity responses. The TV response shows a very high acoustic pressure of 150 dB/lV (ref $1{\mu}Pa$ at 1m) at 1900 Hz. This ultra high power response of the sonar transducer indicates a new possibility of the sonar transducer development.

  • PDF

Structural design of a piezoelectric flextentional deep-water sonar transducer using a coupled FE-BEM (결합형 유한요소-경계요소 기법을 사용한 심해저용 압전형 유연성 쏘나 트랜스듀서의 구조 설계)

  • Jarng, Soon-Suck;Chung, Woon-Kwan
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.377-387
    • /
    • 1999
  • A piezoelectric flextentional deep-water sonar transducer has been designed using a coupled FE-HEM. The dynamics of the sonar transducer is modelled in three dimensions and is analyzed with external electrical excitation conditions. Different results are available such as steady-state frequency response for TX displacement modes, directivity patterns, resonance frequencies, TVRs. While the conventional barrel-stave typed sonar transducer of the piezoelectric material is designed, the external surface of the transducer is modified in order to allow the same hydrostatic pressure to be applied onto the inner and the outer surfaces of the transducer. With this modification for deep-water application, a new resonance mode is generated at lower frequency. This lower resonance mode can be adjusted according to the degree of the outer surface modification.

  • PDF